首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To study the indoor climate, the psychosocial work environment and occupants' symptoms in offices a cross-sectional questionnaire survey was made in 11 naturally and 11 mechanically ventilated office buildings. Nine of the buildings had mainly cellular offices; five of the buildings had mainly open-plan offices, whereas eight buildings had a mixture of cellular, multi-person and open-plan offices. A total of 2301 occupants, corresponding to a response rate of 72%, completed a retrospective questionnaire. The questionnaire comprised questions concerning environmental perceptions, mucous membrane irritation, skin irritation, central nervous system (CNS) symptoms and psychosocial factors. Occupants in open-plan offices are more likely to perceive thermal discomfort, poor air quality and noise and they more frequently complain about CNS and mucous membrane symptoms than occupants in multi-person and cellular offices. The association between psychosocial factors and office size was weak. Open-plan offices may not be suited for all job types. PRACTICAL IMPLICATION: Open-plan offices may be a risk factor for adverse environmental perceptions and symptoms.  相似文献   

2.
A series of ventilation, thermal and indoor air quality measurements were performed in 14 different dairy buildings in Estonia and Finland. The number of animals in the buildings varied from 30 to 600. Measurements were made all year round with ambient temperatures ranging between −40 °C and +30 °C. The results showed that microclimatic conditions in the dairy buildings were affected by the design of the building, outside temperature, wind, ventilation and manure handling method. The average inside air concentration of carbon dioxide was 950 ppm, ammonia 5 ppm, methane 48 ppm, relative humidity 70% and inside air velocity was 0.2 m/s. Although occasionally exceeded, the ventilation and average indoor air quality in the dairy buildings were mainly within the recommended limits.  相似文献   

3.
The objective of this study was to determine benzene and 1,3-butadiene exposure through ambient air and personal air monitoring, as well as through biomarkers of exposure, and to evaluate the potential health risk of exposure through the use of biomarkers of early biological effects in central Bangkok traffic policemen. Ambient air concentrations of benzene and 1,3-butadiene at the roadsides were significantly higher than in police offices used as control sites (p < 0.001). Traffic policemen had a significantly higher exposure to benzene (median 38.62 μg/m3) and 1,3-butadiene (median 3.08 μg/m3) than office policemen (median 6.17 μg/m3 for benzene and 0.37 μg/m3 for 1,3-butadiene) (p < 0.001). Biomarkers of benzene exposure, blood benzene, and urinary metabolite, trans, trans-muconic acid were significantly higher in traffic policemen than office policemen (p < 0.001). No significant difference between traffic and office policemen was found in urinary benzene metabolite, S-phenyl mercapturic acid, or in urinary 1,3-butadiene metabolite, monohydroxy-butenyl mercapturic acid. Biomarkers of early biological effects, 8-hydroxy-2′-deoxyguanosine in leukocytes (8-OHdG), DNA-strand breaks, and DNA-repair capacity, measured as an increase in gamma ray-induced chromosome aberrations were significantly higher in traffic policemen than controls (p < 0.001 for 8-OHdG, p < 0.01 for tail length, p < 0.001 for olive tail moment, p < 0.05 for dicentrics and p < 0.01 for deletions). Multiple regression model including individual exposure, biomarkers of exposure, ages and years of work as independent variables showed that only the levels of individual 1,3-butadiene exposure were significantly associated with 8-OHdG and olive tail moment at p < 0.0001 indicating more influence of 1,3-butadiene on DNA damage. These results indicated that traffic policemen, who are exposed to benzene and 1,3-butadiene at the roadside in central Bangkok, are potentially at a higher risk for development of diseases such as cancer than office policemen.  相似文献   

4.
Treatment of fresh air in ventilation systems for air-conditioned offices consumes a significant amount of energy and affects the indoor air quality (IAQ). In this study, energy impact on the ventilation systems was examined against certain IAQ objectives for indoor airborne bacteria exposure risk in air-conditioned offices of Hong Kong. The relationship between thermal energy consumptions and indoor airborne bacteria exposure levels based on regional surveys was investigated. The thermal energy consumptions of ventilation systems operating for carbon dioxide (CO2) exposure concentrations between 800 and 1200 ppmv for typical office buildings and the corresponding failure probability against some target bacteria exposure levels were evaluated. The results showed that, for a reference indoor environment at a CO2 exposure concentration of 1000 ppmv, the predicted average thermal energy saving of ventilation system for a unit increment of the expected risk of unsatisfactory IAQ of 1% was 55 MJ m−2 yr−1 and for a unit decrement of 1%, the predicted additional thermal energy consumption was 58 MJ m−2 yr−1 respectively. This study would be a useful source of reference in evaluation of the energy performance of ventilation strategies in air-conditioned offices at a quantified exposure risk of airborne bacteria.  相似文献   

5.
The temperature and humidity independent control (THIC) system, which controls indoor temperature and moisture separately, may be an attractive alternative to existing conventional HVAC systems for its prominent improvement on the overall system performance and utilization of low grade energy resources. In order to verify the effectiveness of THIC system, a pilot project has been implemented in an office building in Shenzhen, China. In the system, liquid desiccant fresh air handling units driven by heat pumps are utilized to remove the entire latent load of outdoor air supplied for the whole building, and chilled water at the temperature of 17.5 °C from chiller is pumped and distributed into dry fan coil units and radiant panels to control indoor temperature. This paper presents the results of field test of the system, which shows that the system can provide a comfortable indoor environment even in very hot and humid weather. The COP of the entire THIC system can reach 4.0. According to the energy usage data recorded from the year 2009, the energy consumption of the THIC system in the tested office building was 32.2 kWh/(m2 yr), which demonstrates magnificent energy-saving potential compared with the conventional air-conditioning system (around 49 kWh/(m2 yr)).  相似文献   

6.
The thermal environment for air-conditioned offices in subtropical climates is examined from the prospect of maintaining an optimum operative temperature for the occupants. In this study, the optimum neutral temperature is evaluated from 422 occupants’ responses towards the perceiving thermal environment in 61 air-conditioned offices and 186 complaints of thermal discomfort in an air-conditioned office building on an electronic questionnaire, using a semantic differential evaluation scale and a dichotomous assessment scale. In particular, physical parameters for the thermal comfort study were measured by an indoor environmental quality (IEQ) logger, and the operative temperature was correlated with the occupants’ thermal responses. The probability of accepting an operative temperature for the thermal comfort of the occupants was correlated with logistic regression curves; the optimum operative temperature was derived in order to maximize the probability of thermal comfort expressed by the occupants. The results showed that the thermal neutral temperatures for air-conditioned offices in subtropical climates were 23.6 and 21.4 °C in summer and winter, respectively. The preferred thermal environment in Hong Kong should be slightly cool, corresponding to about 1 °C below the neutral temperature, in order to satisfy most of the occupants in the office space.  相似文献   

7.
In this study, the results of odour concentration measurements on different wastewater treatment plants are presented and used in order to estimate the odour emission factors relevant to single odour sources. An odour emission factor is a representative value that relates the quantity of odour released to the atmosphere to a specific activity index, which in this case was the plant treatment capacity, resulting in an odour emission factor expressed in odour units per cubic metre of treated sewage. The results show that the major odour source of a wastewater treatment plant is represented by the primary sedimentation (with an OEF equal to 1.9 × 105 ouE m−3). In general, the highest OEFs are observed in correspondence of the first steps of the wastewater depuration cycle (OEF between 1.1 × 104 ouE m−3 and 1.9 × 105 ouE m−3) and tend to decrease along the depuration process (OEF between 7.4 × 103 ouE m−3 and 4.3 × 104 ouE m−3). In general, the OEFs calculated according to this approach represent a model for a rough prediction of odour emissions independently from the specific characteristics of the different plants.  相似文献   

8.
M.D. Butler  Y.Y. Wang 《Water research》2009,43(5):1265-1697
Experiments were carried out to establish whether nitrous oxide (N2O) could be used as a non-invasive early warning indicator for nitrification failure. Eight experiments were undertaken; duplicate shocks DO depletion, influent ammonia increases, allylthiourea (ATU) shocks and sodium azide (NaN3) shocks were conducted on a pilot-scale activated sludge plant which consisted of a 315 L completely mixed aeration tank and 100 L clarifier. The process performed well during pre-shock stable operation; ammonia removals were up to 97.8% and N2O emissions were of low variability (<0.5 ppm). However, toxic shock loads produced an N2O response of a rise in off-gas concentrations ranging from 16.5 to 186.3 ppm, followed by a lag-time ranging from 3 to 5 h ((0.43-0.71) × HRT) of increased NH3-N and/or NO2 in the effluent ranging from 3.4 to 41.2 mg L−1. It is this lag-time that provides the early warning for process failure, thus mitigating action can be taken to avoid nitrogen contamination of receiving waters.  相似文献   

9.
The degradation of geosmin and 2-methylisoborneol (2-MIB) by UV irradiation at different wavelengths was investigated under varying boundary conditions. The results showed that conventional UV radiation (254 nm) is ineffective in removing these compounds from water. In contrast to the usual UV radiation UV/VUV radiation (254 + 185 nm) was more effective in the removal of the taste and odour compounds. The degradation could be described by a simple pseudo first-order rate law with rate constants of about 1.2 × 10−3 m2 J−1 for geosmin and 2-MIB in ultrapure water. In natural water used for drinking water abstraction the rate constants decreased to 2.7 × 10−4 m2 J−1 for geosmin and 2.5 × 10−4 m2 J−1 for 2-MIB due to the presence of NOM. Additionally, the formation of the by-product nitrite was studied. In the UV/VUV irradiation process up to 0.6 mg L−1 nitrite was formed during the complete photoinitiated oxidation of the odour compounds. However, the addition of low ozone doses could prevent the formation of nitrite in the UV/VUV irradiation experiments.  相似文献   

10.
In this study, a novel self-regenerating electric vapor compression heat pump desiccant (HPD) unit operated in the heating and humidification mode during the winter season is introduced. The HPD unit was installed in an office suite for the field test. The performance of the HPD unit and the provided indoor conditions were measured over a wide range of operating conditions. The target indoor humidity ratio was set to 4.4 g/kg, which is the minimum required indoor humidity ratio for a comfortable indoor environment indicated in the ASHRAE winter thermal comfort zone. The seasonal comparison revealed that even though 77.7% of all outdoor humidity ratio data was lower than 4.4 g/kg, 78.2% and 85.8% of all the indoor humidity ratio data of each room were found to be higher than 4.4 g/kg. In addition, due to the significant sensible capacity of the HPD unit, the indoor temperatures could be maintained within 20-25 °C. These results prove that the HPD unit not only properly humidifies the indoors without using any additional water source, like the conventional humidifier, but also helps to keep the indoor temperature at the desired temperature levels.  相似文献   

11.
The use of hygroscopic materials for moisture buffering is a passive way to moderate the variation of indoor humidity. Through absorption and desorption, surface materials in the indoor environment, such as curtains, carpets and wall paper, are able to dampen the moisture variations. The moisture buffering capacity of these materials may be used to improve the relative humidity of the indoor environment at reduced energy costs.The objectives of this paper are threefold. The first objective is to derive a theoretical model for the transient moisture transfer between a curtain system and the indoor air for the case where the curtain is placed in front of a wall. The second objective is to conduct experiments inside environmental chambers to validate the theoretical model and to test the ability of curtains to moderate indoor humidity. It is shown that the experimental results for the curtain moisture uptake and the relative humidity inside the chamber compared well with the model simulation results. The third and final objective is to test and evaluate the model under “real environment conditions” for a case study of a hygroscopic cotton curtain, placed in a “typical” office space in the city of Beirut with an area of 25 m2 that uses direct expansion (DX) air conditioning system. It is found that hygroscopic curtains maintain humidity of less than 65% during part load operation compared to the upper limit of 70% relative humidity when no curtain is used. On the other hand, it is found that the energy use, as determined by the daily electrical power consumption of the DX system, is almost the same for the two cases, (with and without a curtain), where approximately 20 kWh of energy input is required 13 kWh of sensible energy and 7 kWh of latent energy.  相似文献   

12.
Based on the generic dynamic building energy simulation environment, EnergyPlus, the simulation model of energy recovery ventilator (ERV) is developed in this paper. With different indoor temperature set-points, the energy performance of ERV along with the availability of ERV is investigated both for Beijing and Shanghai weathers in China in terms of the ratio of heat recovery to energy supply by HVAC devices and ERV. Simulation results show that the seasonal average of the ratio is linear with indoor temperature set-points. The availability of ERV in Shanghai is better than that in Beijing during the winter. In summer, the utilization of ERV is uneconomical if the indoor temperature set-point is higher than 24 °C for the Beijing climate. The indoor temperature set-points have the reverse effects to the availability of ERV in the mid-season and to that in the hottest months. Meanwhile, the heating amount recovery in summer and the cooling amount recovery in winter, both of which impair the strong points of the energy recovery, are analyzed quantitatively.  相似文献   

13.
Indoor environment quality has great influence on worker's productivity, and how to assess the effect of indoor environment on productivity remains to be the major challenge. A neurobehavioral approach was proposed for evaluation of office workers' productivity in this paper. The distinguishing characteristic of neurobehavioral approach is its emphasis on the identification and measurement of behavioral changes, for the influence of environment on brain functions manifests behaviorally. Therefore worker's productivity can be comprehensively evaluated by testing the neurobehavioral functions. Four neurobehavioral functions, including perception, learning and memory, thinking, and executive functions were measured with nine representative psychometric tests. The effect of room temperature on performance of neurobehavioral tests was investigated in the laboratory. Four temperatures (19 °C, 24 °C, 27 °C, and 32 °C) were investigated based on the thermal sensation from cold to hot. Signal detection theory was utilized to analyze response bias. It was found that motivated people could maintain high performance for a short time under adverse (hot or cold) environmental conditions. Room temperature affected task performance differentially, depending on the type of tasks. The proposed neurobehavioral approach could be worked to quantitatively and systematically evaluate office workers' productivity.  相似文献   

14.
室内办公环境品质直接影响办公室中人员的工作效率和健康,需要进行有效地控制和优化,以保证其舒适性、低能耗和健康的要求。以某办公室为对象,研究了室内环境品质各参数和控制量之间的关系,建立了室内环境品质双线性模型。利用实验数据进行了模型验证,结果表明:模型输出能较好拟合实际情况;并基于模型预测方法进行室内环境品质控制,通过夏季工况仿真实验证明了提出方法比传统控制方式具有更小的稳态误差和较小的超调性,且更加节能。  相似文献   

15.
This field study was performed during the winter of 2000–2001 in order to investigate the thermal environment and thermal comfort in residential buildings in Harbin, northeast of China. A total of 120 participants provided 120 sets of physical data and subjective questionnaires. An indoor climate analyzer and a thermal comfort meter made in Denmark were used to collect the measured parameters of the indoor environment, the predicted mean vote (PMV), and predicted percentage of dissatisfied (PPD). The conclusions are as follows: males are less sensitive to temperature variations than females; the neutral operative temperature of males is 1 °C lower than that of females; Harbin subjects are as sensitive to temperature variations as the Beijing and Tianjin subjects; the minimum value of PPD (7.5%) is similar to the Tianjin occupants; both the sensitivity and the minimum value of PPD are lower than those of the foreign field studies.  相似文献   

16.
Fanger's PMV-PPD is the most famous thermal sensation indices but it is too complex to be applied in practice. To obtain simple and applicable correlations, taking Qujing of Yunnan province, China, as example, a wet season (six-month) field measurement was conducted in a naturally ventilated residential room. Based on collected data, PMV indices were calculated by using Newton's iterative method. It is shown that the PMV values approximately vary from −1.0 to +1.0 and the indoor thermal environment is basically comfortable. Relationships of the parameters (indoor and outdoor air temperatures, mean radiant temperature, PMV and PPD) and indoor air temperature gradients (vertical and horizontal) were also studied by means of the linear regression and the quadratic polynomial fit techniques. Numerous correlations with high relativities have been developed. Moreover, the vertical and horizontal air temperature gradients range from 0.1 K/m to 0.85 K/m and from −0.208 K/m to 0.063 K/m in wet season. It is convenient to use these results to evaluate and assess the indoor thermal environment under similar climatic conditions. The results of this work enrich and develop the basic theory of the indoor thermal environment design and control.  相似文献   

17.
It is possible to evaluate the energy demand as well as the parameters related to indoor thermal comfort through building energy simulation tools. Since energy demand for heating and cooling is directly affected by the required level of thermal comfort, the investigation of the mutual relationship between thermal comfort and energy demand (and therefore operating costs) is of the foremost importance both to define the benchmarks for energy service contracts and to calibrate the energy labelling according to European Directive 2002/92/CE. The connection between indoor thermal comfort conditions and energy demand for both heating and cooling has been analyzed in this work with reference to a set of validation tests (office buildings) derived from a European draft standard. Once a range of required acceptable indoor operative temperatures had been fixed in accordance with Fanger's theory (e.g. −0.5 < PMV < −0.5), the effective hourly comfort conditions and the energy consumptions were estimated through dynamic simulations. The same approach was then used to quantify the energy demand when the range of acceptable indoor operative temperatures was fixed in accordance with de Dear's adaptive comfort theory.  相似文献   

18.
In this study, the relationship between cardiovascular mortality and traffic-related air pollutants (NO2, CO, PM10, and six volatile organic compounds (VOCs), propane, iso-butane, propylene, benzene, meta-, para-, and ortho-xylenes) was investigated. The concentrations of NO2, PM10 and CO from 1993 to 2006 were measured at a fixed-site air monitoring station, and VOC data from 2003 to 2006 were obtained from a photochemical assessment monitoring site in an urban area in central Taiwan. Outcome variables were data on mortality due to cardiovascular diseases (ICD-9-CM 410-411, 414, 430-437) from 1993 to 2006. Cardiovascular mortality averaged 1.5 cases, ranging between 0 and 9 cases per day. Daily air pollution levels ranged from 0.5 to 80.5 ppb for NO2 and from 0.1 to 3.8 ppm for CO. From the subset of data from 2003 to 2006, daily average values ranged from 0.6 to 17.5 ppb for propane, 0.3 to 6.7 ppb for iso-butane, 0.3 to 6.7 ppb for propylene, 0.2 to 3.8 ppb for benzene, 0.3 to 26.0 ppb for m,p-xylene, and 0.02 to 7.6 ppb for o-xylene. Poisson generalized additive model was used to estimate the effects of elevated air pollutant levels on daily mortality, adjusting for meteorological conditions and temporal trends. Single-pollutant model showed that cardiovascular mortality was significantly associated with NO2 lagged 2 days, and with propane, iso-butane, and benzene lagged 0 day. The relative risk for an interquartile range increase in air pollutant levels was 1.053 for NO2, 1.064 for propane, 1.055 for iso-butane, and 1.055 for benzene. In conclusion, daily cardiovascular mortality showed association with data on acute exposure to traffic air pollutants in Taichung, which is an important factor to consider in studying cardiovascular mortality in urban environments.  相似文献   

19.
The effects of indoor environment quality on productivity were reviewed. It could be concluded that there was a need to systematically and quantitatively measure the effect of indoor environment quality on office worker's productivity. An experiment was carried out in field laboratory to investigate the effect of indoor air temperature (17 °C, 21 °C, and 28 °C) on productivity with 21 participants (6 females and 15 males). Participants' performance was evaluated with 13 computerized neurobehavioral tests, which assessed different neurobehavioral functions including visual perception, working memory, reasoning, executive functions etc. Participants' emotion was assessed with the Profile of Mood States (POMS), which consisted of six identifiable mood states: tension, depression, anger, vigor, fatigue, and confusion. Effort exerted on each neurobehavioral test was tapped with subjective questionnaires. The results revealed that more information could be provided when the subjective questionnaires were utilized together with the neurobehavioral performance measures. The POMS showed high reliability to investigate the relationship between thermal environment and occupant productivity. The performance of neurobehavioral tests decreased when the thermal environment deviated from neutral condition. Participants experienced more negative emotions and had to exert more effort to maintain their performance under moderately adverse (slightly warm or slightly cool) environmental conditions.  相似文献   

20.
通过对北京市某地下车库内苯,甲苯,一氧化碳(CO),二氧化氮(NO2)和二氧化硫(SO2)五种污染物的现场测试和对附近人员的问卷调查发现,车库中苯和甲苯浓度超标,最高浓度分别为4.82mg/m3和15.50mg/m3;CO、NO2和SO2浓度相对较低,没有超过相关标准浓度,但仍高于周围环境中污染物浓度。车库内和排风口周围人群普遍受到影响,不满意率达100%,其中受影响最大的为车库内工作人员。受影响人群普遍感到存在有较强烈的异味,并伴随着咽喉肿痛、刺眼/流泪、咳嗽等症状。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号