 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper the Rayleigh-Ritz method was used to study the scanning near-field optical microscope (SNOM) with a tapered optical fiber probe's flexural and axial sensitivity to vibration. Not only the contact stiffness but also the geometric parameters of the probe can influence the flexural and axial sensitivity to vibration. According to the analysis, the lateral and axial contact stiffness had a significant effect on the sensitivity of vibration of the SNOM's probe, each mode had a different level of sensitivity and in the first mode the tapered optical fiber probe was the most acceptive to higher levels of flexural and axial vibration. Generally, when the contact stiffness was lower, the tapered probe was more sensitive to higher levels of both axial and flexural vibration than the uniform probe. However, the situation was reversed when the contact stiffness was larger. Furthermore, the effect that the probe's length and its tapered angle had on the SNOM's probe axial and flexural vibration were significant and these two conditions should be incorporated into the design of new SNOM probes.  相似文献   

2.
A near-field scanning optical module has been constructed as an accessory for a Nanoscope IIIa commercial scanning probe microscope. Distance feedback and topographic registration are accomplished with an uncoated optical fibre scanning tip by implementation of the shear force technique. The tip is driven by a piezoelectric actuator at a resonance frequency of 8–80 kHz. A laser diode beam is scattered by the tip and detected by a split photodiode, with lock-in detection of the difference signal. The amplitude ( r ) and phase (τ) responses were characterized as a function of the calibrated tip–sample separation. Using an r cos τ feedback signal, imaging of pUC18 relaxed circular plasmid DNA spread on mica precoated with cetylpyridinium chloride was achieved. The apparent width (28 ± 5 nm) was approximately four times that achieved by scanning force measurements with the same instrument; the apparent height of the DNA (0.6 ± 0.3 nm) was similar with the two techniques. These results demonstrate the applicability of the shear force signal for imaging biological macromolecules according to topography and in conjunction with the optical signals of a near-field scanning optical microscope (NSOM).  相似文献   

3.
We introduce a method of dye fluorescence excitation and measurement that utilizes a near-field scanning optical microscope (NSOM). This NSOM uses an apertureless metallic probe, and an optical system that contains a high numerical aperture (NA) objective lens (NA = 1.4). When the area which satisfies NA < 1 is masked, the objective lens allows for the rejection of possible transmitted light (NA < 1) through the sample. In such conditions, the focused spot consists of only the evanescent field. We found that this NSOM system strongly reduces the background of the dye fluorescence and allows for the measurement of the fluorescence intensity below the diffraction limit of the excitation source.  相似文献   

4.
We introduce a method of dye fluorescence excitation and measurement that utilizes a near-field scanning optical microscope (NSOM). This NSOM uses an apertureless metallic probe, and an optical system that contains a high numerical aperture (NA) objective lens (NA= 1.4). When the area which satisfies NA < 1 is masked, the objective lens allows for the rejection of possible transmitted light (NA < 1) through the sample. In such conditions, the focused spot consists of only the evanescent field. We found that this NSOM system strongly reduces the background of the dye fluorescence and allows for the measurement of the fluorescence intensity below the diffraction limit of the excitation source.  相似文献   

5.
A nonoptical detection of the optical fibre tip has been developed. By detecting the output signal from a tiny piezoelectric detector attached to the vibrating fibre tip, the distance between the fibre tip and the sample has been successfully controlled. The frequency responses of the system composed of tip, the dither and the detector have been studied. The difference between the shear-force detection and the tapping-mode detection is discussed. It is found that the shear force exerted on the tip reduces the vibration amplitude with an unvaried resonance frequency. However, in the tapping mode, the resonance frequency varies with the tip–sample distance as the force is exerted on the fibre tip only within a half period. This requires better adjustments for the tapping-mode detection.  相似文献   

6.
Wang K  Wang X  Jin N  Huang W  Xu J 《Journal of microscopy》1999,194(PT 2-3):317-320
A nonoptical detection of the optical fibre tip has been developed. By detecting the output signal from a tiny piezoelectric detector attached to the vibrating fibre tip, the distance between the fibre tip and the sample has been successfully controlled. The frequency responses of the system composed of tip, the dither and the detector have been studied. The difference between the shear-force detection and the tapping-mode detection is discussed. It is found that the shear force exerted on the tip reduces the vibration amplitude with an unvaried resonance frequency. However, in the tapping mode, the resonance frequency varies with the tip-sample distance as the force is exerted on the fibre tip only within a half period. This requires better adjustments for the tapping-mode detection.  相似文献   

7.
The properties of the probe-surface contact for a near-field optical microscope driven in the shear force mode have been studied applying lateral amplitudes of the probing fiber tip larger than 15 nm. Electric current measurements between a conductive tip and a conductive sample reveal a pulsed current behavior at the very beginning of the approach curve. In the upper part of the approach curve it turns to the quasiconstant current. From this observation a conclusion is drawn about the presence of permanent mechanical contact between the probe and the surface in the shear force mode. A shift of the approach curve along the z-axis as a function of dither amplitude was discovered. These results are in contradiction to the established conception of possible physical mechanisms of shear force interaction. To settle this issue the friction model is proposed according to which the damping of the probe vibrations is caused by the friction between the tip and the surface.  相似文献   

8.
We studied a nanometre-sized optical probe in a scanning near-field optical microscope. The probe profile is determined by using a knife-edge method and a modulated transfer function evaluation method which uses nanometre-sized line-and-space tungsten patterns (with spaces 1 microm to 50 nm apart) on SiO2 substrates. The aluminium-covered, pipette-pulled fibre probe used here has two optical probes: one with a large diameter (350 nm) and the other with a small diameter (10 nm). The small-diameter probe has an optical intensity approximately 63 times larger than that of the large-diameter probe, but the power is about 1/25 of that of the large probe.  相似文献   

9.
We studied a nanometre-sized optical probe in a scanning near-field optical microscope. The probe profile is determined by using a knife-edge method and a modulated transfer function evaluation method which uses nanometre-sized line-and-space tungsten patterns (with spaces 1 μm to 50 nm apart) on SiO2 substrates. The aluminium-covered, pipette-pulled fibre probe used here has two optical probes: one with a large diameter (350 nm) and the other with a small diameter (10 nm). The small-diameter probe has an optical intensity ≈63 times larger than that of the large-diameter probe, but the power is about 1/25 of that of the large probe.  相似文献   

10.
We present a fibre-top probe fabricated by carving a tipped cantilever on an optical fibre, with the tip machined in correspondence of the fibre core. When approached to an optical prism illuminated under total internal reflection conditions, the tip of the cantilever detects the optical tunnelling signal, while the light coupled from the opposite end of the fibre measures the deflection of the cantilever. Our results suggest that fibre-top technology can be used for the development of a new generation of hybrid probes that can combine atomic force microscopy with scanning near field optical microscopy.  相似文献   

11.
A new microscope system that has the combined capabilities of a scanning near-field optical microscope (SNOM) and a scanning tunnelling microscope (STM) is described. This is achieved with the use of a single metallic probe tip. The distance between the probe tip and the sample surface is regulated by keeping the tunnelling current constant. In this mode of operation, information about the optical properties of the sample, such as its refractive index distribution and absorption characteristics, can be disassociated from the information describing its surface structure. Details of the surface structure can be studied at resolutions smaller than the illumination wavelength. The performance of the microscope is evaluated by analysing a grating sample that was made by coating a glass substrate with gold. The results are then compared with the corresponding SNOM and STM images of the grating.  相似文献   

12.
A. Naber 《Journal of microscopy》1999,194(2-3):307-310
The dynamic force distance control for scanning near-field optical microscopy on the basis of a tuning fork as piezoelectric force sensor is remarkably sensitive. In order to gain a better understanding of this sensitivity the vibrational properties of the tuning fork are modelled within the framework of two coupled harmonic oscillators. As a result, the effective force constant of the tuning fork at resonance frequency is determined. Furthermore, the influence of the additional mass by the attachment of the near-field probe is investigated.  相似文献   

13.
Naber A 《Journal of microscopy》1999,194(PT 2-3):307-310
The dynamic force distance control for scanning near-field optical microscopy on the basis of a tuning fork as piezoelectric force sensor is remarkably sensitive. In order to gain a better understanding of this sensitivity the vibrational properties of the tuning fork are modelled within the framework of two coupled harmonic oscillators. As a result, the effective force constant of the tuning fork at resonance frequency is determined. Furthermore, the influence of the additional mass by the attachment of the near-field probe is investigated.  相似文献   

14.
In this paper, the conjugate gradient method of minimization with an adjoint equation is successfully applied to solve the inverse problem in estimating the shear force between the tapered probe and sample during the scanning process of scanning near-field optical microscope (SNOM). While knowing the available deflection at the tapered probe tip, the determination of the interaction shear force is regarded as an inverse vibration problem. In the estimating processes, no prior information on the functional form of the unknown quantity is required. The accuracy of the inverse analysis is examined by using the simulated exact and inexact measurements of deflection at the tapered probe tip. Numerical results show that good estimations on the interaction shear force can be obtained for all the test cases considered in this study.  相似文献   

15.
Fluorescently labelled myofibrils were imaged in physiological salt solution by near-field scanning optical microscopy and shear-force microscopy. These myofibrils were imaged in vitro , naturally adhering to glass while retaining their ability to contract. The Z-line protein structure of the myofibrils was antibody labelled and easily identified in the near-field fluorescence images. The distinctive protein banding structure of the myofibril was also seen clearly in the shear-force images without any labelling requirement. With the microscope in the transmission mode, resolution of the fluorescence images was degraded significantly by excessive specimen thickness (>1 μm), whereas the shear-force images were less affected by specimen thickness and more affected by poor adherence to the substrate. Although the exact mechanism generating contrast in the shear-force images is still unknown, shear-force imaging appears to be a promising new imaging modality.  相似文献   

16.
A novel etching method for an optical fibre probe of a scanning near-field optical microscope (SNOM) was developed to fabricate a variety of tip shapes through dynamic movement during etching. By moving the fibre in two-phase fluids of HF solution and organic solvent, the taper length and angle can be varied according to the movement of the position of the meniscus on the optical fibre. This method produces both long (sharp angle) and short (wide angle) tapered tips compared to tips made with stationary etching processes. A bent-type probe for a SNOM/AFM was fabricated by applying this technique and its throughput efficiency was examined. A wide-angle probe with a 50 degrees angle at the tip showed a throughput efficiency of 3.3 x 10(-4) at a resolution of 100 nm.  相似文献   

17.
A novel etching method for an optical fibre probe of a scanning near-field optical microscope (SNOM) was developed to fabricate a variety of tip shapes through dynamic movement during etching. By moving the fibre in two-phase fluids of HF solution and organic solvent, the taper length and angle can be varied according to the movement of the position of the meniscus on the optical fibre. This method produces both long (sharp angle) and short (wide angle) tapered tips compared to tips made with stationary etching processes. A bent-type probe for a SNOM/AFM was fabricated by applying this technique and its throughput efficiency was examined. A wide-angle probe with a 50° angle at the tip showed a throughput efficiency of 3.3 × 10−4 at a resolution of 100 nm.  相似文献   

18.
Shear force near‐field microscopy on biological samples in their physiological environment loses considerable sensitivity and resolution as a result of liquid viscous damping. Using a bimorph‐based cantilever sensor incorporating force feedback, as recently developed by us, gives an alternative force detection scheme for biological imaging in liquid. The dynamics and sensitivity of this sensor were theoretically and experimentally discussed. Driving the bimorph cantilever close to its resonance frequency with appropriate force feedback allows us to obtain a quality factor (Q‐factor) of up to 103 in water, without changing its intrinsic resonance frequency and spring constant. Thus, the force detection sensitivity is improved. Shear force imaging on mouse brain sections and human skin tissues in liquid with an enhanced Q‐factor of 410 have shown a high sensitivity and stability. A resolution of about 50 nm has been obtained. The experimental results suggest that the system is reliable and particularly suitable for biological cell imaging in a liquid environment.  相似文献   

19.
Sugiura T  Kawata S  Okada T 《Journal of microscopy》1999,194(PT 2-3):291-294
We investigated fluorescence imaging using a near-field scanning optical microscope which uses a laser-stabilized gold nanoparticle as a near-field probe. This microscope is suitable for observations of biological specimens in aqueous solutions because the probe particle is held by a noncontact force exerted by a laser beam. Theoretical calculations based on Mie scattering theory are presented to evaluate the near-field enhancement by a gold particle of 40 nm diameter. We also present fluorescence images of a single fluorescent bead and discuss the near-field contribution to the fluorescence image in this type of microscope.  相似文献   

20.
We investigated fluorescence imaging using a near-field scanning optical microscope which uses a laser-stabilized gold nanoparticle as a near-field probe. This microscope is suitable for observations of biological specimens in aqueous solutions because the probe particle is held by a noncontact force exerted by a laser beam. Theoretical calculations based on Mie scattering theory are presented to evaluate the near-field enhancement by a gold particle of 40 nm diameter. We also present fluorescence images of a single fluorescent bead and discuss the near-field contribution to the fluorescence image in this type of microscope.  相似文献   