首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
This study compared the performance of a glass ionomer (GC Gold Label 1, GIC) as a fiber post cementation system for glass fiber posts with a self‐adhesive resin cement (Relyx U200, RUC) and a conventional resin cement system (Scotchbond Muli‐Purpose and Relyx ARC, RAC). Thirty endodontically treated canines were randomly divided in three groups (n = 10), according to the fiber post cementation system: (RAC)—Scotchbond Multi‐Purpose and Relyx X ARC; (RUC)—Relyx U200 and (GIC)—GC Gold Label 1 Luting & Lining. Rhodamine was incorporated into the cementation system prior to the fiber post cementation. After glass fiber post cementation, roots were incubated in artificial saliva for 6 months. After that, specimens from the cervical, middle, and apical thirds of the post space were prepared and analyzed using a push‐out bond strength test and confocal laser microscopy. ANOVA one way and Tukey tests showed that GIC and RUC demonstrated similar push‐out bond strength values, independently of the post space third (p > .05); however, values were greater than those shown by RAC (p < .05). For dentin penetrability, GIC and RUC also had similar results (p > 0.05) and lower than RAC (p < 0.05). Inside the root canal, the cementation system using glass ionomer cement (GC Gold Label 1 Luting & Lining) has similar push‐out bond strength to the self‐adhesive resin cement (Relyx U200) and these were higher than the conventional resin (Relyx ARC), despite its higher dentin penetrability.  相似文献   

2.
The aim of this study was to evaluate the combined effect of MTAD and photon‐induced photoacoustic streaming (PIPS) technique on the smear layer removal and the bond strength of glass fiber post. Fifty‐five human mandibular premolars were chosen. After root canal therapy and post space preparation, the teeth were equally divided to five groups according to the methods of root‐dentin pretreatment: G1: distilled water (control); G2: 2.5% NaOCl+17% EDTA; G3: MTAD; G4: PIPS; G5: MTAD+PIPS. One sample was randomly selected from each group, and scanning electron microscope (SEM) was used to observe the microscopic morphology of the coronal, middle and apical level of the root‐dentin. The remaining ten samples from each group were glued to glass fiber posts, and the bond strength was assessed by push‐out test. SEM evaluation showed that the most complete smear layer removal was found in MTAD + PIPS group, especially in coronal third. Push‐out test results exhibited that there was a statistically significant interaction between the experimental groups and root canal third (p < .0005). Significant differences could be found among five groups (p < .05): G5 > G4 > G3 > G2 > G1. G5 had the highest bond strength. In conclusion, post space pretreatments with MTAD or PIPS technique can significantly remove smear layer and improve the bond strength of glass fiber post, and combination of them works best.  相似文献   

3.
This study evaluated the effect of Er,Cr:YSGG laser on the root canal dentin after luting a fiber post. Twenty‐four bovine teeth roots were prepared using NiTi instruments and filled with Sealer 26 and gutta‐percha. Post spaces were prepared and roots were distributed according to dentin treatment (n = 8): 2.5%NaOCl (group control), Er,Cr:YSGG laser (1.5 W, 20 Hz, 20 s) (group test 1) or 2.5%NaOCl + Er,Cr:YSGG laser (group test 2). Fiber posts were luted using adhesive cement (Rely X U200, 3M) and roots were prepared to confocal laser scanning microscopy (CLSM) and scanning electron microscope (SEM). The morphology of interface, thickness of cement, and the gaps and tags were analyzed. Non‐parametrical data for thickness of cement were submitted to Friedman and Kruskall–Wallis tests (α = 0.05) and parametrical data for gaps to ANOVA (α = 0.05). CLSM of the cement thickness and gaps revealed no significant difference in surface treatment (NaOCl, Er,Cr:YSGG laser and NaOCl + Er,Cr:YSGG laser) (p > .05) and canal thirds (cervical, middle, and apical) (p > 0.05). SEM showed tags and a residual layer of cement adhered to dentin, mainly in laser‐irradiated specimens. The pretreatment of root canal with Er,Cr:YSGG laser previously to luting the fiber post with a self‐adhesive cement did not influence the cement thickness and gaps but affected the dentin interaction.  相似文献   

4.
This study evaluated the effect of 10% sodium hypochlorite (NaOCl) as deproteinizing agent and storage media on bond strength (BS) of two etch‐and‐rinse adhesive systems to dentin. Twenty‐eight sound extracted human third molars were divided in four groups (n = 7), according to dentin treatment (conventional etching or etching followed by 10% NaOCl application) and adhesive systems (GB—Gluma 2Bond and OS—One‐Step). After dentin treatments and adhesive application, a composite block was built‐up on dentin surface and teeth were serially sectioned to obtain bonded sticks specimens. The sticks were submitted to three aging conditions: (24H) 24 hr in water (immediate), (SH) 3 hr of NaOCl accelerated‐aging or (1Y) 1 year of water storage. Afterward, submitted to microtensile bond strength test (μTBS), failure modes and adhesive interfaces analyzes. Data were analyzed by two‐way analysis of variance (ANOVA) and Tukey's test (α = .05). Dentin deproteinization before bonding significantly reduced μTBS for GB‐treated group (p < .05), regardless the aging conditions. Water storage for 1 year (1Y) and NaOCl accelerated‐aging (SH) decreased μTBS for both adhesives. Yet, the groups stored in NaOCl (SH) exhibited the lowest BS results (p < .05). Bond strength of deproteinized dentin was dependent on the adhesive system composition and NaOCl accelerated‐aging promoted decreased bond strength and further degradation than water storage for 1 year.  相似文献   

5.
This experimental study aims to evaluate the radiopacity of various fiber post materials and to determine the effects of material composition as analyzed by energy‐dispersive X‐ray spectrophotometry (EDS; EDAX Team Software; EDAX, Inc., Mahwah, NJ) on radiopacity. Five specimens of seven fiber post materials with 2‐mm thickness were prepared and digital radiographs were taken with an aluminum stepwedge (SW) and 2‐mm‐thick tooth slice. The mean gray values (MGVs) of specimens were measured using the histogram function of a computer graphics program (Adobe Photoshop CS6; Adobe System, Inc., San Jose, CA). The MGVs of fiber post materials were compared with an aluminum SW and dentin of equal thickness. The fiber post specimens were examined by scanning electron microscopy and EDS analysis performed for the elementary analysis of material composition. The MGVs of fiber posts ranged between 83.67 ± 3.64 and 57.80 ± 7.08 pixels. Materials were sorted in descending order of MGV as follows: Reforpost, Carbopost, D.T. Light‐Post, Easypost, Glassix Radiopaque, Dentolic Glass Fiber Post, and RelyX Fiber Post. All fiber posts demonstrated significantly higher radiopacity values than 2‐mm‐thick aluminum (p < .05). EDS analysis results indicated that the evaluated fiber posts included various elements for radiopacity in different ratios. All tested fiber post materials showed radiopacity values above the minimum recommendations of the International Organization for Standardization. EDS analysis results indicated that each manufacturer used different compositions of elements like zirconium, barium, titanium, and iron for achieving radiopacity in materials.  相似文献   

6.
The aim of this in vitro study was to compare the efficacies of two different fiber post‐removal systems. Thirty extracted single‐rooted mandibular premolar teeth were used. After RelyX fiber posts were cemented, the teeth were divided into two groups with regard to the post removal techniques: ultrasonic vibration and D.T. Light‐Post removal kit. Residual material, tooth volume changes, working time and micro‐crack formation were assessed using micro‐computed tomography. All data were analyzed using Wilcoxon signed‐rank and Mann–Whitney U tests. There was significantly more tooth root volume change in the ultrasonic group than removal kit group (p < .05). Fiber post removal time for the ultrasonic group was significantly longer than the removal kit group (p < .01).  相似文献   

7.
Morphology, etching patterns, surface modification, and characterization of 2 different fiber posts: Gfp, Glass fiber post; and Cfp, carbon fiber were investigated by SEM analysis, after different surface treatments. Thirty fiber posts, being 15 Gfp and 15 Cfp were divided into a 5 surface treatments (n = 3): C-alcohol 70% (control); HF 4%-immersion in 4% hydrofluoric acid for 1min; H(3) PO(4) 37%-immersion in 37% phosphoric acid for 30s; H(2) O(2) 10%-immersion in 10% hydrogen peroxide for 20 min; H(2) O(2) 24%-immersion in 24% hydrogen peroxide for 10 min. Morphology, etching patterns, surface modification and surface characterization were acessed by SEM analysis. SEM evaluation revealed that the post surface morphology was modified following all treatment when compared with a control group, for both type of reinforced posts. HF seems to penetrate around the fibers of Gfp and promoted surface alterations. The Cfp surface seems to be inert to treatment with HF 4%. Dissolution of epoxy resin and exposure of the superficial fiber was observed in both post groups, regardless the type of reinforcing fiber, H(2) O(2) in both concentrations. Relative smooth surface area was produced by H(3) PO(4) 37% treatment, but with similar features to untreated group. Surface treatment of fiber post is a determinant factor on micromechanical entanglement to resin composite core. Post treatment with hydrogen peroxide resulted strength of carbon and glass/epoxy resin fiber posts to resin composite core.  相似文献   

8.
The aim of the current study was to evaluate the presence of debris and smear layer after endodontic irrigation with different formulations of 2% chlorhexidine gluconate (CHX) and its effects on the push‐out bond strength of an epoxy‐based sealer on the radicular dentin. One hundred extracted human canines were prepared to F5 instrument and irrigated with 2.5% sodium hypochlorite and 17% ethylenediaminetetraacetic acid. Fifty teeth were divided into five groups (n = 10), according to the final irrigation protocol with different 2% CHX formulations: G1 (control, no final rinse irrigation), G2 (CHX solution), G3 (CHX gel), G4 (Concepsis), and G5 (CHX Plus). In sequence, the specimens were submitted to scanning electron microscopy (SEM) analysis, in the cervical‐medium and medium‐apical segments, to evaluate the presence of debris and smear layer. The other 50 teeth were treated equally to a SEM study, but with the root canals filled with an epoxy‐based endodontic sealer and submitted to a push‐out bond strength test, in the cervical, middle, and apical thirds. G2, G3, G4, and G5 provided higher precipitation of the debris and smear layer than G1 (P < 0.05), but these groups were similar to each other (P > 0.05), in both segments. The values obtained in the push out test did not differ between groups, independent of the radicular third (P > 0.05). The CHXs formulations caused precipitation of the debris and smear layer on the radicular dentin, but these residues did not interfere in the push‐out bond strength of the epoxy‐based sealer. Microsc. Res. Tech. 77:17–22, 2014. © 2013 Wiley Periodicals, Inc.  相似文献   

9.
This study evaluates the bond strength of four self‐etching adhesive systems with different acidity levels in normal and artificially hypermineralized dentin substrate. Healthy human molars were divided into groups: normal dentin—N (n = 36) and artificially hypermineralized dentin—H (n = 36). Self‐etching adhesive systems Clearfil S3 Bond (n = 9), Optibond All in One (n = 9), Clearfil SE Bond (n = 9), and Adhese (n = 9) were used for both the N and H groups. Transparent cylindrical matrices were positioned on the treated dentin surfaces, filled with composite resin, and light‐cured for 40 s. After the transparent cylindrical matrices were removed, the specimens were stored for 24 hr in a humid environment at 37°C and were subjected to a micro‐shear bond strength test. For each group, a specimen was prepared and evaluated in scanning electron microscope for adhesive interface observation. Normality was confirmed and the two‐way analysis of variance and Games–Howell post‐tests were conducted (α = .05). The data demonstrated an interaction between the adhesive system and type of dentin substrate (p < .01). For normal dentin, all adhesive systems assessed were adequate; however, in the hypermineralized dentin, the Clearfil SE Bond two‐step self‐etching adhesive system with mild pH presented the highest immediate bond strength. There was a predominance of adhesive failures for all adhesive systems in the different dentin substrates evaluated. It was concluded that the self‐etching adhesive systems evaluated were efficient for both substrates, and for the hypermineralized dentin, the Clearfil SE Bond presented a higher bond strength value.  相似文献   

10.
Aim of this study was to determine the fracture strength and modes of endocrown and overlay restorations with/without fiber reinforcement on endodontically treated teeth. Sixty-five molar teeth were used: Group IN (intact teeth), Group E (endocrown), Group ER (endocrown + ribbond), Group O (overlay), Group OR (overlay + ribbond; n = 13). Ribbond (Seattle, WA) was inserted at the base of pulp chamber in Group ER and OR. All restorations were designed and produced by using computer-aided design and computer-aided manufacturing (Sirona Dental Systems, Bensheim, Germany) and Cerasmart (GC Corp. Kasugai, Aichi, Japan). All teeth were subjected to thermomechanical aging and fractured in a universal test device. Fractured surfaces were analyzed with a stereomicroscope (SMZ1000, Nikon, Japan). Data were analyzed with Welch's analysis of variance and Games–Howell test (p < .001). Group E showed significantly lower fracture strength values than other groups(p < .05). No statistically significant differences were found among the other groups(p > .05). Most of the unfavorable fractures were seen in Groups E and O. Overlay restorations showed higher fracture strength values than endocrown restorations. Although fiber insertion did not improve the fracture strength of the indirect restorations, it reduced the frequency of irreparable fracture mode. Overlay restorations and fiber application are more advantageous in preserving the durability of the endodontically treated teeth.  相似文献   

11.
The aim was to assess the effects of 1% peracetic acid (PAA) as a single endodontic irrigant on microhardness, roughness, and erosion of root canal dentin, compared with 2.5% sodium hypochlorite (NaOCl) and with 2.5% NaOCl combined with 17% EDTA. Forty human, single‐rooted tooth hemisections were submitted to Knoop microhardness test, before and after the following irrigation protocols: PAA = 1% PAA; NaOCl = 2.5% NaOCl; NaOCl‐EDTA‐NaOCl = 2.5% NaOCl +17% EDTA +2.5% NaOCl; and SS = saline. Another 40 roots were instrumented, irrigated with the same protocols, and sectioned longitudinally. The roughness analysis was performed on the mesial section using a confocal laser scanning microscope, whereas erosion was analyzed on each third of the distal section, using a scanning electron microscope. The data were analyzed using ANOVA and Tukey post‐tests, and Kruskal‐Wallis and Dunn post‐tests (α = .05). The PAA and NaOCl‐EDTA‐NaOCl groups showed no significant differences (p > .05); both promoted reduction in microhardness and increase in roughness, compared with the NaOCl and SS groups (p < .05). NaOCl‐EDTA‐NaOCl promoted higher erosion in the cervical and middle thirds than the other groups (p < .05); there was no difference among PAA, NaOCl, and SS (p > .05). There was also no difference among the groups regarding the apical third (p > .05). PAA used as a single endodontic irrigant caused reduction in root canal dentin microhardness and increase in roughness in a similar way to NaOCl‐EDTA‐NaOCl; however, PAA caused less erosion than NaOCl‐EDTA‐NaOCl.  相似文献   

12.
The morphological and chemical changes in deciduous dentin produced by different conditioning protocols were evaluated in this in vitro study. Eighty primary dentin samples were divided into eight groups (n = 10): G1, acid etching; G2, self‐etching adhesive; G3, G4, Er: YAG laser irradiation at 25.5 and 38.2 J cm?2, respectively; 10 Hz and spray irrigation. Groups 5, 6, 7, and 8 were irradiated at previous densities, and then phosphoric acid or self‐etching adhesive conditioning was applied. Scanning electron microscopy (SEM) and energy dispersive X‐ray spectroscopy (EDS) were used to evaluate chemical and morphological changes. Paired t‐test and One‐way ANOVA were used for statistical analysis (p ≤ 0.05). All samples showed different morphology with specific characteristics according to the conditioning protocol. Changing element concentration values are expressed in atomic percent (at %). After conditioning, there were statistically significant differences (p ≤ 0.05) for p at% and Ca/P in all groups; highlighting the following additional findings by group: G1, G7, and G8 showed changes in all elements studied, G2 presented a decrease in C at% and increased Ca at%, G3 and G4 exhibited at% changes in C, trace elements and Ca. Furthermore, G5 showed at% changes in O and trace elements; while G6 changes were observed on C at%, O at% and trace elements at%. Dentin morphology and chemical composition varied in accordance with the conditioning protocol, with characteristics specific for each one that could have clinical implications for the retention and bond strength performance of adhesive materials.  相似文献   

13.
Oxalate‐based products are effective against dentine sensitivity and have been studied as an option to improve long‐term adhesive bonding strength. Our aim was to evaluate the effect of potassium oxalate on the microtensile bond strength (µTBS) of the dentin/resin interface after 24 h, 1, and 6 years. Dentin on the occlusal surface of 16 human premolars was exposed and etched with 35% phosphoric acid. The teeth were divided into four groups. Two groups received 3% monohydrated potassium oxalate and the following adhesive systems and composites: Adper Scotchbond Multipurpose + FiltekZ350 (3M/ESPE) and Prime & Bond NT + Esthet‐X (Dentsply). Two control groups did not receive potassium oxalate. Teeth were cut into sticks and kept in distilled water at 37°C for 24 h, 1, and 6 years. The sticks underwent µTBS testing after storage. ANOVA, Tukey's post hoc test, and paired t test were used to compare storage times (α = 0.05). The fracture mode of the specimens was classified under a stereomicroscope (40×). Morphology of the hybrid layer and the fracture pattern were observed with scanning electronic microscopy (SEM). Mean µTBS was high at 24 h and decreased after 1 and 6 years. After 6 years, the mean µTBS values were similar with no statistically significant difference between the groups (p = .121). SEM images showed proper dentin hybridization. Dentin pretreatment with potassium oxalate did not affect hybrid layer formation, but bond strength decreased over time after 24 h. Therefore, the clinical use of potassium oxalate to increase dentin bond durability is not indicated.  相似文献   

14.
15.
This study aimed to evaluate the microleakage of a universal adhesive's different application modes incorporated with Er,Cr:YSGG laser on Class V resin composite restorations. Sound human molar teeth (n = 30) were used for microleakage evaluations. Specimens with 60 standardized Class V cavities were divided into five groups according to the adhesive modes of universal adhesive, Adhese Universal (n = 12). Group 1‐etch‐and‐rinse mode with phosphoric acid; Group 2‐etch‐and‐rinse mode with Er,Cr:YSGG laser; Group 3‐selective‐etch mode with phosphoric acid; Group 4‐selective‐etch mode with Er,Cr:YSGG laser; Group 5‐self‐etch. After restorations were performed with a resin composite, Tetric N‐Ceram, the specimens were polished and subjected to thermocycling (10,000X). Following immersion in 0.5% basic fuschin for a day, the teeth were sectioned and the degree of microleakage was determined along the tooth‐resin composite interface using a light microscopy(40X). Five specimens from each group were examined by scanning electron microscopy. The Kruskal–Wallis, Siegel Castello, and Wilcoxon tests were used for statistical analyses (α = .05). At the enamel margins, significant differences were obtained among the groups (p < .05). Significantly higher microleakage scores were detected in Group 5 in comparison with Groups 1, 2, and 3. There were no significant differences between different adhesive strategies at the dentin margins (p > .05). While analyzing enamel and dentin microleakage scores, no statistically significant differences were observed in Groups 4 and 5 (p > .05). The laser application time and the adhesive modes of universal adhesives could affect the microleakage at the enamel margins. Different adhesive modes of universal adhesives combined with laser etching had no influence on the microleakage scores of dentin margins.  相似文献   

16.
This study aimed to investigate dentin wettability and surface morphology after selective removal of carious lesion by erbium‐doped yttrium aluminum garnet (Er:YAG) laser, followed by dentin biomodification with carbodiimide (EDC) and chitosan (CHI). Seventy‐eight bovine dentin specimens were submitted to caries induction. Specimens were distributed according to methods of carious removal (n = 39): bur at low‐speed (40,000 rpm) or Er:YAG laser (noncontact mode, 250 mJ/pulse and 4Hz). All specimens were etched with 35% phosphoric acid, and subdivided according to dentin biomodification (n = 13): Control (no biomodification), EDC or CHI. The contact angle (n = 10) between adhesive system (3M ESPE) and dentin surface was measured by a goniometer. Eighteen specimens (n = 3) were analyzed by scanning electron microscopy. Data were analyzed by two‐way ANOVA and Tukey's test (α = .05). The method used to remove carious lesion did not influence the wettability of dentinal surface (p = .748). The angles produced on the remaining dentin after biomodification were influenced (p = .007). CHI promoted higher contact angles (p = .007) and EDC did not differ from the control group (p = .586). In the bur‐treated group, most tubules were open, regardless of which biomodifier was used. Laser modified the organic matrix layer. CHI promoted partially closed tubules in some areas while EDC exposed dentinal tubules. Regardless of which method was used for selective removal of carious lesion, biomodification with EDC did not affect the dentin wettability, whereas CHI changed the wettability of remaining dentin. Both biomodifiers promoted a slight change on dentin morphology.  相似文献   

17.
Previous studies have shown the effects of Er,Cr:YSGG laser irradiation on the dentin bond strength; but there are few reports that show the significance of the irradiation with different laser parameters on dentin bond strength and interface morphology. This in‐vitro study attempted to evaluate the microtensile bond strength (μTBS) and interface morphology of resin‐dentin interfaces, either followed by treatment with Er,Cr:YSGG laser irradiation with different parameters or not. The flattened dentin samples of 35 bovine teeth were embedded into acrylic blocks and randomly divided into seven groups according to surface treatments using Er,Cr:YSGG lasers with different parameters: 3 W/20 Hz, 3 W/35 Hz, 3 W/50 Hz, 1.5 W/20 Hz, 1.5 W/35 Hz, 1.5 W/50 Hz, or no laser treatment (n = 5). Composite buildups were done over bonded surfaces and stored in water (24 hours at 37°C). Specimens were sectioned into sticks that were subjected to μTBS testing and observed under FE‐SEM. Control groups (27.70 ± 7.0) showed statistically higher values than laser‐irradiated groups. There were no significant differences among laser groups. Despite that, increasing the pulse frequency yielded slightly higher bond strength. Depending on laser settings, Er,Cr:YSGG laser irradiation caused interfacial gaps and resin tags with wings morphology. With the parameters used in this study, Er,Cr:YSGG laser irradiation promoted morphological changes within resin‐dentin interfaces and negatively influenced the bond strength of adhesive systems. Microsc. Res. Tech. 78:1104–1111, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

18.
The aim of this in‐vitro study was to evaluate microtensile bond strength (μTBS) of two different self‐adhesive composites (SACs) on the permanent dentin by applying five different universal adhesive systems. In this study, two different SACs [Vertise Flow (VF), Fusio Liquid Dentin (FLD)] and five different bonding systems [Clearfil Universal Bond Quick (CUB), Single Bond Universal (SBU), All Bond Universal (ABU), Prime Bond Universal (PBU), Futurabond U (FBU)] were used. A total of 22 groups were created in which SACs were applied without adhesive and with five different universal bonding agents in total‐etch (TE) and self‐etch (SE) modes. Two hundred and forty test sticks were obtained using 48 healthy human molar teeth in total with groups having 10 samples each. The μTBS test was applied to each sample in the Universal test device and the data obtained were analyzed statistically by variance analysis and Tukey HSD test. In addition, the resin–dentin interface and fractures modes in the groups were examined by SEM. Upon examining the μTBS results, the highest values were seen in the use of SBU adhesive in TE mode in VF group, while the lowest values were seen in the FLD control group. The difference between the control and experimental groups was found statistically significant (p < .05). Upon comparing the control groups with each other, it was seen that VF group had higher μTBS values than FLD group and the difference between the groups was found statistically significant (p < .05). The μTBS results and SEM images of the study showed that the use of SACs with universal adhesive systems provides a more effective bond strength.  相似文献   

19.
The aim of this study was to evaluate the shear bond strength of repairs in porcelain conditioned with laser. Sixty porcelain discs were made and six groups were formed (n = 10): G1: conditioning with laser with potency 760 mW; G2: conditioning with laser with potency 760 mW and application of 37% phosphoric acid for 15 s; G3: conditioning with laser with potency 900 mW; G4: conditioning with laser with potency 900 mW and application of 37% phosphoric acid for 15 s; G5: application of 37% phosphoric acid for 15 s (group control) and G6: application of 10% hydrofluoric acid for 2 min. The composite resin was insert of incremental layers at the porcelain surface aided with a metal matrix, and photoactivation for 20 s each increment. The specimens were submitted to a thermal cycling by 1000 cycles of 30 s in each bath with temperature between 5 and 55°C. After the thermal cycling, specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance and Tukey's tests with 5% significance. The averages and standard deviation founded were: G1, 11.25 (±3.10); G2, 12.32 (±2.65); G3, 14.02 (±2.38); G4, 13.44 (±2,07); G5, 9.91 (±2,18); G6, 12.74 (±2.67). The results showed that the femtosecond laser produced a shear bond strength of repairs in porcelain equal to the hydrofluoric acid and significantly superior to the use of phosphoric acid. Microsc. Res. Tech., 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

20.
In the present research, different adhesive techniques were used to set up fillings with composite resins. After the application of etch and rinse or self etch adhesive technique, marginal adaptation of composite fillings was estimated by the length of margins without gaps, and by the microretention of resin in enamel and dentin. The study material consisted of 40 extracted teeth. Twenty Class V cavities were treated with 35% phosphorous acid and restored after rinsing by Adper Single Bond 2 and Filtek UltimateASB/FU 3M ESPE composite system. The remaining 20 cavities were restored by Adper Easy OneAEO/FU 3M ESPE composite system. Marginal adaptation of composite fillings was examined using a scanning electron microscope (SEM). The etch and rinse adhesive technique showed a significantly higher percentage of margin length without gaps (in enamel: 92.5%, in dentin: 57.3%), compared with the self‐etch technique with lower percentage of margin length without gaps, in enamel 70.4% (p < .001), and in dentin‐22.6% (p < .05). In the first technique, microretention was composed of adhesive and hybrid layers as well as resin tugs in interprismatic spaces of enamel, while the dentin microretention was composed of adhesive and hybrid layers with resin tugs in dentin canals. In the second technique, resin tugs were rarely seen and a microgap was dominant along the border of restoration margins. The SEM analysis showed a better marginal adaptation of composite resin to enamel and dentin with better microretention when the etch and rinse adhesive procedure was applied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号