首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
The purpose of this prospective study was to investigate the clinical outcome and marginal bone resorption of three different endosseous implants placed in the anterior mandibles of 15 elderly patients. Eleven women and 4 men (ranging from 65 to 80 years, mean 71 years) had three different endosseous implants placed in the anterior mandible; one titanium plasma-sprayed cylinder implant (4-mm diameter), one titanium cylinder implant with hydroxyapatite coating (4-mm diameter), and one standard threaded titanium implant (3.75-mm diameter). Three months later, at the second-stage surgical procedure, ball abutments were connected and an overdenture was placed. At 12, 24, and 36 months, marginal bone resorption and Periotest values were recorded. None of the implants was lost in this period. An analysis of variance with repeated measurement was performed annually to test the existence of significant differences between the implants. When differences appeared, paired t tests were used to identify which differences were significant. Bonferroni multipliers were used to adjust for multiple testing. When marginal bone resorption was concerned, threaded titanium and hydroxyapatite-coated implants had significantly better scores than titanium plasma-sprayed cylinder implants. Periotest values for hydroxyapatite-coated implants were significantly better than test values for the other implants after 2 years. After 3 years significance was obtained between hydroxyapatite and screw-shaped implants only (P < .05). It was concluded that titanium plasma-sprayed cylinder implants have a less favorable prognosis than the other implants used in this study.  相似文献   

2.
In 1991, the Dental Implant Clinical Research Group initiated a long-term clinical study in cooperation with the Department of Veterans Affairs to investigate the influence of implant design, application, and site of placement on clinical performance and crestal bone height. As part of this investigation, Periotest values for 2,212 root from implants were determined at second-stage surgery and during a 24-month follow-up period. Mean Periotest values decreased for implants placed in quality 1 and 2 bone, did not change for implants in quality 3 bone, and increased for implants in quality 4 bone. Implants in the posterior maxilla and single implants in the anterior maxilla had increasing mean Periotest values as compared with decreasing values for implants in other regions. Mean Periotest values for uncoated implants decreased gradually to approach those of hydroxyapatite-coated implants.  相似文献   

3.
The feasibility of implant treatment in patients after oral ablative tumor surgery has not yet been investigated with consideration of the requisite high periodontal standards. A report on this topic has to deal not only with implant survival but also with implant health, bone response, soft tissue health, failure pattern, time of failure, and ease of restoration. For the assessment of an implant system, an overview must be accomplished that takes into account the different restorations used and their interaction with the implant system that was used. This study presents the Bone-Lock implant system (Howmedica Leibinger GmbH, Freiburg, Germany) in a retrospective investigation after 5 years of follow-up with special emphasis on the prosthetic restorations used following resection of oral malignancies. From early in 1990 through June 1996, we inserted 210 dental endosteal Bone-Lock implants (58 patients) after oral tumor resectioning. Included in the study were 45 patients with 162 implants and prosthetic restorations that had been loaded for 1 year (dentures retained by telescopic or bar-clip or ball attachments, implant-supported prostheses, tooth-to-implant connected bridges). Regular follow-up consisted of evaluation of the Plaque Index (Silness and L?e) and of the Sulcus Bleeding Index (L?e), measurements of pocket probing depth, implant mobility (by means of the Periotest method), bone resorption (according to X-ray findings), and a questionnaire that registered patient satisfaction. The results were evaluated for each restoration and were compared with baseline standards. The overall 5-year survival rate was 83.2%. For implants that had been in place for over 365 days, the survival rate was 93%. The investigation showed that after resection of oral malignancies, patients could be treated with dental implants and superstructures with long-term efficacy similar to that found in healthy subjects considering internationally accepted standards. Implant treatment in tumor patients appeared to offer the most positive periodontic results when use of bar-clip or telescope-retained overdentures was involved. The patient satisfaction level with the described prosthodontic treatment was satisfactory.  相似文献   

4.
A commercially pure titanium threaded implant was compared to a hydroxyapatite-coated threaded implant of similar geometric design and dimensions in the canine model. Bilateral posterior implants supported fixed prostheses, and some implants in the same mandibles served as unloaded control implants. Implants were evaluated clinically, radiographically, and histomorphometrically at the light microscope level to detect any differences in bone response to loaded conditions. No statistically significant differences were found between the two implant designs under loaded or nonloaded conditions with regard to mobility, probing depth, percentage of osseointegration, and crestal bone position.  相似文献   

5.
The objective of this study was to analyze the efficacy and correlation between clinical and histologic parameters used to evaluate oral implants. After extraction of the premolars and a healing time of 4 months in 16 Dutch goats, four Br?nemark implants were placed in the maxillary left and right premolar regions. After a healing time of 6 months, followed by another 4 months with the permucosal abutments, the goats were sacrificed and the jaws were block-resected. Before histologic preparation, long-cone radiographs were made and Periotest scores of the implants were recorded. Bone level measured histomorphometrically were found to be 0.85 mm more apically, compared to that measured radiologically (P = .001). Furthermore, statistically significant correlations (P > 0.2) were not found between the Periotest values of the calcium-phosphate-coated and uncoated implants for (1) the first thread in contact with bone, or (2) with the total number of threads in contact with bone. It was concluded that the radiologic data overscored the real marginal bone level around screw-shaped oral implants, and that the Periotest device is neither able to discriminate between the first thread nor between the total number of threads in contact with bone.  相似文献   

6.
The aim of this study was to evaluate clinically, histologically and histometrically the use of anorganic bovine bone matrix (i.e. Bio-oss) as a grafting material for maxillary sinus augmentation procedures. In 4 adult male rhesus monkeys (i.e. Macaca mulatta) the 1st, 2nd and 3rd maxillary molars on one side of the jaws were extracted. The remaining bone between the alveolar crest and the bottom of the sinus was then reduced to 3-4 mm. After 3 months, maxillary sinus augmentation procedures were performed on one side of the jaws in each monkey and the sinuses were grafted with the bovine bone matrix. At that time, 2 IMZ pure titanium plasma coated implants were immediately placed into the augmented sinuses (i.e. simultaneous implants-loaded group). After 4 months, 2 additional similar implants were placed into these previously augmented sinuses (i.e. delayed implants-loaded group). Four months later, the abutment connection was performed and all 4 implants were loaded with a gold-alloy bridge for 6 months (i.e. until sacrifice of the animals). The contralateral side of each monkey received the same treatment with the exception that the extractions were performed 7 months after those in the opposite side and that the implants in this side were not loaded. Thus, 2 additional study groups (i.e. simultaneous implants-unloaded group and delayed implants-unloaded group) were obtained. Clinically, all loaded implants were stable at the day of sacrifice. Histologically, the grafted sinuses exhibited significant bone formation with integration of the bovine bone matrix particles to the new bone. Direct mineralized bone-to-implant contact was greater for the delayed implant placement groups than for the implants installed simultaneously with the sinus augmentation. Furthermore, the percentage of direct mineralized bone-to-implant contact was greater in the residual bone than in the augmented area. It was concluded that the anorganic bovine bone matrix facilitated bone formation and implant osseointegration in the augmented sinuses and that the delayed implant placement in combination with the sinus augmentation procedure seemed to be preferable.  相似文献   

7.
In order to achieve esthetically more satisfying results, it has been proposed to place ITI implants with their border between the rough and smooth surfaces below the level of the alveolar crest, thereby obtaining a submucosally located implant shoulder following healing. The aim of the present experimental study was to clinically and radiographically evaluate the tissue response to the placement of one-stage transmucosal implants with the border between the rough and the smooth surfaces sunk by 1 mm into a subcrestal location. 11 patients underwent comprehensive dental care including the placement of 2 implants of the ITI Dental Implant System in the same quadrant (test and control). Randomly assigned control implants were placed according to the manufacturer's instructions, i.e. the border between the rough titanium plasma-sprayed and the smooth polished surfaces precisely at the alveolar crest. At the test implant the apical border of the polished surface was placed approximately 1 mm below the alveolar crest. Probing bone levels were assessed at implant placement (baseline), 4 and 12 months later. Modified plaque and modified gingival indices were recorded at 1, 2, 3, 4 and 12 months. Clinical probing depth and "attachment" levels were measured at 4 and 12 months. All parameters were assessed at 6 sites around each implant. The mean for each implant was calculated and used for analysis. The Wilcoxon matched pairs signed rank test and the Student t-test were applied to detect differences over time and between the test and control implants. At baseline, a mean difference in probing bone level of -0.86 mm (SD 0.43 mm, p < 0.05) was found between test and control implants with the test implants being placed more deeply. Both test and control implants lost a significant amount of clinical bone height during the first 4 months (test 1.16 mm, p < 0.05; control 0.58 mm, p < 0.05). However, only the test implants significantly lost clinical bone height from 4-12 months (test 1.04 mm, p < 0.05; control 0.45 mm, p = 0.08). Overall, the test implants lost 2.26 mm and the control implants 1.02 mm of bone height during the first year of service. On the average, the test implants demonstrated a bone level of 0.38 mm lower than the controls at 12 months. Except for the modified gingival index at 4 months (mean difference 0.21, SD 0.19, p < 0.05), no clinical parameters yielded significant differences between test and control implants at any time. It is concluded that in addition to the crestal bone resorption occurring at implants placed under standard conditions, the bone adjacent to the polished surface of more deeply placed ITI implants is also lost over time. From a biological point of view, the placement of the border between the rough and the smooth surfaces into a subcrestal location should not be recommended.  相似文献   

8.
This report outlines the experimental, surgical, and prosthodontic protocols for a prospective clinical trial using the Endopore dental implant to replace single maxillary teeth. Twenty patients (10 male, 10 female) ranging in age from 30 to 60 years each received one implant (mean length 10.1 mm), which, after an initial healing period of 4 months, was restored with a single crown. Records collected included radiographs, Periotest mobility measurements, supragingival Plaque Index, and an assessment of peri-implant soft tissue health using pocket probing depths, sulcular bleeding following probing, and probing attachment levels. Radiographs were exposed at predetermined intervals following crown placement (1 and 6 months, and then yearly) in a standardized procedure using a specialized filmholder that attaches to each implant after removal of the crown. At the time of this preliminary report, all of the 20 implants placed had been uncovered and were in function; 16 of the implants had been in function for 6 months or more, 14 had passed 1 year of function, and 3 had passed the 2-year function point. There have been no failures to date.  相似文献   

9.
The osteogenesis of mandibular bone to endosteal dental implants was examined using an in vivo dog model. One half of the implants examined were unloaded implants, with the remaining one half prosthodontically loaded for 6 months. Undecalcified mandibular implant samples were examined with both high-voltage electron microscopy (HVEM) stereology and routine transmission electron microscopy. The osseous interface to integrated implants was shown to vary in its morphology. Mineralized bone was observed directly apposing the implant, often separated from the implant by an electron-dense deposit of approximately 50 nm. Within this densely mineralized matrix, osteocytes were routinely observed. Adjacent areas were shown to contain slightly wider zones of either a less dense mineralized matrix or, alternatively, unmineralized tissue. Other zones consisted of wider unmineralized matrices containing collagen fibers and osteoblasts. These latter zones were consistent with the appearance of an appositional type of bone growth. Because bone is a dynamic, actively remodeling tissue, a varied morphology of the support tissues to dental implant is not unexpected. Areas of mature bone interfacing with successfully integrated implants were demonstrated, as well as areas adjacent to the mature bone that were undergoing remodeling or mineralization. This study has also shown that HVEM stereology is a valuable research tool to investigate the oral tissue interface with dental implants.  相似文献   

10.
The histologic examination of dental implants retrieved from humans is important to establish the causal determinants of implant failure, and to compare and validate the results obtained from animal studies. This study presents a retrospective review of the histologic features of 230 implants retrieved in an 8-year period (1989-1996). All the implants were treated to obtain thin (20 to 30 microm) ground sections. The majority of implants were retrieved because of mobility (n=56), peri-implantitis (n=54), or fractures (n=90). Peri-implantitis occurred more frequently before (n=44) than after (n=10) abutment connection. A dense fibrous connective tissue with no inflammatory cells was present at the interface in the implants retrieved for mobility; bone was found only in the most apical part. In many of these implants epithelial cells were present. The main histologic features of peri-implantitis consisted of the presence of a bone sequestrum near the implant, many bacteria present on the implant surface, and an inflammatory infiltrate (macrophages, lymphocytes, and plasma-cells) nearby. Histology showed that in the implants removed for fracture, there was a very high percentage (80 to 100%) of peri-implant bone.  相似文献   

11.
We hypothesized that early bone adaptation to well fixed porous-coated implants is influenced more by wound healing than by mechanical loading. To test this hypothesis, two groups of dogs with identical, hydraulically controlled porous-coated implants interference fit within distal femoral trabecular bone were used. One group had no load: the other had 35 N of load applied to the implants. At 5 weeks after surgery, the resulting adaptation of bone around the implants was quantified on a cellular basis by cytochemical analysis of type-I procollagen synthesis and on a structural basis using three-dimensional micro-computed tomography imaging. The percentage of trabecular surfaces covered by osteoblasts expressing type-I procollagen was significantly increased in bone surrounding the implant in both groups compared with contralateral control bone tissue. There was no difference between the groups with no load or 35 N of load. In addition, measures of trabecular bone structure did not differ significantly between the load and no-load groups. Taken together, these results suggest that wound healing plays a much greater role in the early response of bone to well fixed porous-coated implants than does mechanical stimulus.  相似文献   

12.
A total of 60 cylindrical 6 x 6 mm samples of a macroporous biphasic calcium phosphate (MBCP) ceramic were implanted into a distal femoral site in 30 rabbits. These samples represented six kinds of implants with two different macropore diameters and three different macroporosity percentages. Analysis of backscattered electron images of implant surfaces analysed by a factorial design method showed that implants with 565 microm pore size provided more abundant newly formed bone both in peripheral and deep pores than those with 300 microm pore size. No significant differences were found between implants with 40 and 50% macroporosity, suggesting that the influence of macropore size on bone ingrowth was greater than that of macroporosity percentage. MBCP implants with 565 microm pore diameter and 40% macroporosity represented the optimal association for homogeneous and abundant bone ingrowth.  相似文献   

13.
This pilot study analyzed the bone reactions to early loaded titanium plasma-sprayed implants. A total of 24 titanium plasma-sprayed implants (12 in the maxilla and 12 in the mandible) (Primary Healing Implant, Legnano) were inserted into four Macaca fascicularis monkeys with instruments specially designed to obtain a precise fit of the implant in the bone socket. A metal superstructure was cemented into 10 mandibular and 10 maxillary implants 15 days after implant insertion. The four remaining implants were used as controls. Eight months after implant placement, a block section was carried out, the defect was filled with nonresorbable hydroxyapatite, and all 24 implants were retrieved. The implants were treated to obtain thin ground sections that were examined under normal and polarized light. Histologic analysis showed that bone was observed around the implant surface in all implants. Morphometric analysis demonstrated that bone lined 67.2% (SD = 3.1%) of the maxillary implant surface, and 80.71% (SD = 4.6%) of the mandibular implant surface. No differences were found in the percentage of bone-implant contact in the control implants. In the loaded implants, however, the bone around the implants had a more compact appearance. The study demonstrated that it is possible to obtain a high percentage of bone-implant contact in early loaded titanium plasma-sprayed implants.  相似文献   

14.
Dental implants are subject to large and highly complex loads of varying magnitude, duration and vector. Bridge performance is closely related to load transmission both at the bone to implant interface and between components within the implant-abutment-bridge cylinder complex. The design of the interface between components within this complex may have a profound influence on the long term function of the implant supported prosthesis. An in vitro evaluation of implants 3.5 mm in diameter, utilizing an internal conical interface has demonstrated increased resistance to bending moments at the fixture-abutment interface (P = 0.00010) and at the abutment-bridge cylinder interface (P < 0.01), when compared to a standard 3.75 mm implant with a hex mediated, butt joint interface. The relatively small values for coefficient of variance measured in both systems would confirm that whilst the size of data is small, it is nonetheless a reliable indication of the relative strength of these implant designs.  相似文献   

15.
Opportunities to increase prosthetic treatment efficiency by means of applying osseointegrated implants of traditional and prospective types are analysed. A technique of mathematical modelling of the interaction between implants and jaw bone is exposed. The numerical model and applied program, developed on the basis of finite element method, enabling to analyse a stress strain state of the bone and to determine extreme safe loads on implants are described. It is shown, that the most loaded zone is a layer of the compact bone directly contiguous to the neck of the implant. That is in good agreement with the results of clinical research, according to which just this zone has the highest percentage of complications. Methods for further optimisation of implants and prosthetic structures for the purpose to perfect the techniques of prosthetic treatment are discussed.  相似文献   

16.
The aim of the present study was to evaluate the capability of the Periotest device in detecting and monitoring functional changes in the periodontal as well as in the pari-implant damping characteristics. In the first part of this study, 107 teeth were splinted by means of 40 full acrylic fixed prostheses (AFP) and another 37 teeth were splinted by means of 14 ceramometallic fixed prostheses (C-MFP). The Periotest measurements of individual teeth were done the day the fixed prostheses were cemented temporary (PTV 1), and again after a mean observation period of 27.4 days (PTV 2). In the 2nd part, 78 osseointegrated two-stage implants were splinted by means of 23 full acrylic fixed prosthesis (AFP) and other 18 implants were left without it. Using the same abutment length, Periotest measurements were performed, at abutment connections and before installation of the final prosthesis. In a 3rd part, using both implants and teeth as abutments, 29 osseointegrated implants were connected with 25 abutment teeth by means of 7 AFP. The measurements were performed at the beginning of the prosthetic treatment and 2, 4 and 6 weeks later. After splinting teeth by means of AFP for the observation period, no statistically significant reduction in PTVs was found. When on the other hand, a C-MFP was used, PTV 2 showed a significant reduction. The PTVs at abutment connection went down after a period of time, during which some implants were interconnected by means of an AFP and others were not.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
The specific aim of this study was to determine the response of alveolar bone after it was augmented vertically using distraction osteogenesis and subsequently loaded with implant restorations. Four dogs each had four implants placed horizontally into an edentulous mandibular quadrant and, after integration, a distraction osteogenesis device was fabricated in the laboratory. An osteotomy was made to allow the crest of the alveolar ridge to be distracted vertically. After 10 mm of vertical distraction, the device was stabilized with light cured resin. Following bone fill confirmation of the distraction gap at 10 weeks, two implants were placed into the ridges, one in distracted bone and one in nondistracted bone. After 4 months for implant integration, freestanding prostheses were fabricated. Crestal bone levels were evaluated throughout the period of function. Animals were sacrificed after 1 year of loading, for histologic evaluation of the bone. The vertical ridge augmentation averaged 8.85 +/- 1.05 mm after 10 weeks of healing following distraction, without change over 1 year of implant loading. Histologic examination showed that bone had formed between the distracted segments, creating an augmented ridge. The average thickness of the labial cortex in the distraction gap was significantly thinner than the lingual cortex in distracted bone and the lingual and labial nondistracted cortical bone. The presence of the dental implant did not significantly affect cortical bone thickness. Serial sections showed that implants remained integrated and functional without soft tissue inflammation. Dental implants placed into alveolar ridges augmented with the technique of distraction osteogenesis maintained bone and were functional for the length of this study.  相似文献   

18.
The authors present a histologic analysis of 19 Branemark titanium implants retrieved for different causes: four implants were removed for abutment fracture, one for dental nerve dysesthesia, two for bone overheating, two for peri-implantitis, nine for mobility, one for unknown causes. In the implants removed for fracture a high bone-implant contact percentage was present (71.83 +/- 4.96%) with compact, mature bone at the interface. The picture of the failure due to bone overheating was characteristic with the presence of bone sequestra and of a gap between implant and bone filled by lymphocytes and plasma cells: many bacteria surrounded the necrotic bone and no newly regenerated bone was present. In peri-implantitis an inflammatory infiltrate was observed in the peri-implant tissues: a dense fibrous connective tissue was present around implants failed for mobility. The microscopical picture is certainly extremely important in identifying the causal determinants of an implant failure.  相似文献   

19.
The aim of this investigation was to evaluate clinically and histologically a new custom-made, root analogue titanium implant placed into extraction sockets in monkeys (Macaca fascicularis). Three adult monkeys were used in this investigation. After raising full thickness flaps on the buccal and lingual side, the upper central and lateral incisors were extracted. Each tooth root was machine copied to 1 titanium analogue using a new CAD/CAM-system. The implants were installed in the respective extraction sockets and the flaps sutured back. After 6 months of healing biopsies were taken and processed according to the cutting-grinding technique. The percentage of mineralized bone-to-implant contact was measured as a fraction of the rough implant surface using computer-assisted analysis. The main clinical problem that occurred during implant placement was the fracture of the buccal alveolar wall. The histometric evaluation showed a mean mineralized bone-to-implant contact of 41.2 +/- 20.6%. In this investigation it could be shown that implants fabricated by laser copying will osseointegrate. The presented data encourage the performance of clinical and experimental trials evaluating the new system utilizing improved second generation CAD/CAM equipment. Such studies are currently underway.  相似文献   

20.
The purpose of this study was to determine which treatment of a large osseous defect adjacent to an endosseous dental implant would produce the greatest regeneration of bone and degree of osseointegration: barrier membrane therapy plus demineralized freeze-dried bone allograft (DFDBA), membrane therapy alone, or no treatment. The current study histologically assessed changes in bone within the healed peri-implant osseous defect. In a split-mouth design, 6 implants were placed in edentulous mandibular ridges of 10 mongrel dogs after preparation of 6 cylindrical mid-crestal defects, 5 mm in depth, and 9.525 mm in diameter. An implant site was then prepared in the center of each defect to a depth of 5 mm beyond the apical extent of the defect. One mandibular quadrant received three commercially pure titanium (Ti) screw implants (3.75 x 10 mm), while the contralateral side received three hydroxyapatite (HA) coated root-form implants (3.3 x 10 mm). Consequently, the coronal 5 mm of each implant was surrounded by a circumferential defect approximately 3 mm wide and 5 mm deep. The three dental implants in each quadrant received either DFDBA (canine source) and an expanded polytetrafluoroethylene membrane (ePTFE), ePTFE membrane alone, or no treatment which served as the control. Clinically, the greatest increase in ridge height and width was seen with DFDBA/ePTFE. Histologically, statistically significant differences in defect osseointegration were seen between treatment groups (P < 0.0001: DFDBA/ePTFE > ePTFE alone > control). HA-coated implants had significantly greater osseointegration within the defect than Ti implants (P < 0.0001). Average trabeculation of newly formed bone in the defect after healing was significantly greater for HA-coated implants than for titanium (P < 0.0001), while the effect on trabeculation between treatments was not significantly different (P = 0.14). Finally, there were significantly less residual allograft particles in defect areas adjacent to HA-coated implants than Ti implants (P = 0.0355). The use of HA-coated implants in large size defects with DFDBA and ePTFE membranes produced significantly more osseointegration histologically than other treatment options and more than Ti implants with the same treatment combinations. The results of this study indicate that, although the implants appeared osseointegrated clinically after 4 months of healing, histologic data suggest that selection of both the implant type and the treatment modality is important in obtaining optimum osseointegration in large size defects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号