首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
采用光线追迹法,分析了空间环境下离轴三反结构系统的猫眼效应。给出了离轴三反系统的像面倾斜、视场和离焦对猫眼回波效率和发散角的影响,证明了离轴三反系统像面倾斜量是决定能否发生猫眼效应的主要因素。提出利用阈值法实现激光主动探测猫眼信号的基本原理,并结合高阶余弦漫反射模型,分析了目标漫反射信号对猫眼信号检测的影响。估算了20km到120km探测距离下,理论上所需不同光束质量激光的最小脉冲能量。仿真表明,当发射光束的全角发散角为0.3mrad时,50km和120km探测距离下所需的最小激光脉冲能量分别为0.7mJ和3.1mJ。最后,通过原理实验,验证了空间激光主动探测法探测目标"猫眼"效应的可行性。  相似文献   

2.
This article describes the completely renovated Thomson scattering (TS) diagnostic employed in the modified Reversed Field eXperiment (RFX-mod) since it restarted operation in 2005. The system measures plasma electron temperature and density profiles along an equatorial diameter, measuring in 84 positions with 7 mm spatial resolution. The custom built Nd:YLF laser produces a burst of 10 pulses at 50 Hz with energy of 3 J, providing ten profile measurements in a plasma discharge of about 300 ms duration. An optical delay system accommodates three scattering volumes in each of the 28 interference filter spectrometers. Avalanche photodiodes detect the Thomson scattering signals and allow them to be recorded by means of waveform digitizers. Electron temperature is obtained using an alternative relative calibration method, based on the use of a supercontinuum light source. Rotational Raman scattering in nitrogen has supplied the absolute calibration for the electron density measurements. During RFX-mod experimental campaigns in 2005, the TS diagnostic has demonstrated its performance, routinely providing reliable high resolution profiles.  相似文献   

3.
We describe an apparatus for attosecond photoelectron spectroscopy of solids and surfaces, which combines the generation of isolated attosecond extreme-ultraviolet (XUV) laser pulses by high harmonic generation in gases with time-resolved photoelectron detection and surface science techniques in an ultrahigh vacuum environment. This versatile setup provides isolated attosecond pulses with photon energies of up to 140 eV and few-cycle near infrared pulses for studying ultrafast electron dynamics in a large variety of surfaces and interfaces. The samples can be prepared and characterized on an atomic scale in a dedicated flexible surface science end station. The extensive possibilities offered by this apparatus are demonstrated by applying attosecond XUV pulses with a central photon energy of ~125 eV in an attosecond streaking experiment of a xenon multilayer grown on a Re(0001) substrate.  相似文献   

4.
A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a "Generation III" image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n(e)) and 6% in the electron temperature (T(e)) at n(e) = 4 x 10(19) m(-3). This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9 x 10(17) m(-3) in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n(e) and T(e) measurement is 7 x 10(20)n(e) J, which means that single shot measurements are possible for n(e)>2 x 10(21) m(-3).  相似文献   

5.
We demonstrate detection and resolution of high power, 34 ns free electron laser pulses using a rectifying field effect transistor. The detector remains linear up to an input power of 11 ± 0.5 W at a pulse energy of 20 ± 1 μJ at 240 GHz. We compare its performance to a protected Schottky diode, finding a shorter intrinsic time constant. The damage threshold is estimated to be a few 100 W. The detector is, therefore, well-suited for characterizing high power THz pulses. We further demonstrate that the same detector can be used to detect low power continuous-wave THz signals with a post detection limited noise floor of 3.1 μW/√Hz. Such ultrafast, high power detectors are important tools for high power and high energy THz facilities such as free electron lasers.  相似文献   

6.
A cryogenically cooled linear electrostatic ion beam trap for use in photoelectron-photofragment coincidence (PPC) spectroscopy is described. Using this instrument, anions created in cold, low-duty-cycle sources can be stored for many seconds in a ~20 K environment to cool radiatively, removing energetic uncertainties due to vibrationally excited precursor anions. This apparatus maintains a well-collimated beam necessary for high-resolution fragment imaging and the high experimental duty cycle needed for coincidence experiments. Ion oscillation is bunched and phase-locked to a modelocked laser, ensuring temporal overlap between ion bunches and laser pulses and that ions are intersected by the laser only when travelling in one direction. An electron detector is housed in the field-free center of the trap, allowing PPC experiments to be carried out on ions while they are stored and permitting efficient detection of 3-dimensional electron and neutral recoil trajectories. The effects of trapping parameters on the center-of-mass trajectories in the laser-ion interaction region are explored to optimize neutral particle resolution, and the impact of bunching on ion oscillation is established. Finally, an initial demonstration of radiative cooling is presented.  相似文献   

7.
设计了一种基于米散射激光雷达的大气气溶胶检测系统。依据米散射激光雷达的原理,研究了激光光束与大气气溶胶的相互作用,设计并搭建了米散射激光雷达大气气溶胶检测实验平台,利用Zemax设计了一套具有滤波聚焦功能的光学望远系统。通过对光束进行扩束并利用可调谐式固定装置来增强回波信号强度。实验结果表明,设计的系统具有高的回波信号...  相似文献   

8.
We discuss the electron-optical properties of the 90 degrees spherical analyzer. A nearly parallel electron beam which can be extracted from a magnetic photocathode in an external magnetic field under suitable conditions is focused to the exit plane of the analyzer. Electron spin polarization detection using Mott scattering can be advantageously combined with such a 90 degrees electron spectrometer so as to achieve energy analysis in spin-polarized photoemission. In this case the diaphragms of the Mott scattering detector play the role of virtual exit slits of the electron spectrometer. Thereby, the limits for variations of the apparatus asymmetry of the Mott scattering setup become reduced, eliminating the need of measuring this quantity in separate measurements.  相似文献   

9.
基于荧光成像的准分子激光系统多路光束自动准直   总被引:1,自引:0,他引:1  
研究了基于准直光束成像的准分子激光主振荡功率放大(MOPA)系统的多路光束自动准直,实现了激光在放大器中的多程放大及高的靶面指向精度。采用352nm He-Cd激光作为准直光源,提出了多光束感光屏同步接收与可见光CCD荧光成像相结合的复合图像采集技术,解决了自动准直系统多路激光的近场、远场图像获取问题。利用图像区域分割处理方法编制了准直信息处理软件,实现了对多光束的自动准直闭环反馈控制。最后,结合准分子激光MOPA系统中的预放大器光学设计进行了自动准直验证实验。结果表明:准直成像光强可调谐倍数为300,成像系统在放大器窗口处固有误差占放大器口径比例小于设计值1.08%,3路激光的自动准直时间为40s,完全满足放大器的几何填充和能量提取要求。  相似文献   

10.
The light detection and ranging Thomson scattering (TS) diagnostic is advantageous since it only requires a single view port into the tokamak. This technique requires a short pulse laser at high energy, usually showing a limited repetition rate. Having multiple lasers will increase the repetition rate. This paper presents a scanning mirror as a laser beam combiner. Measurements of the position accuracy and jitter show that the pointing stability of the laser beam is within ±25?μrad for over tens of seconds. A control feedback loop is implemented to demonstrate the long term stability. Such a system could be applied for ITER and JET.  相似文献   

11.
A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45°. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.  相似文献   

12.
Laser ablation mass spectrometry (LA-MS) has always been an interesting method for the elemental analysis of solid samples. Chemical analysis with a laser requires small amounts of material. Depending on the analytical detection system, subpicogram quantities may be sufficient. In addition, a focused laser beam permits the spatial characterization of heterogeneity in solid samples typically with micrometer resolution in terms of lateral and depth dimensions. With the advent of high-energy, ultra-short pulse lasers, new possibilities arise. The task of this review is to discuss the principle differences between the ablation process of short (>1 ps) and ultra-short (<1 ps) pulses. Based on the timescales and the energy balance of the process that underlies an ablation event, it will be shown that ultra-short pulses are less thermal and cause less collateral damages than longer pulses. The confinement of the pulse energy to the focal region guarantees a better spatial resolution in all dimensions and improves the analytical figures of merit (e.g., fractionation). Applications that demonstrate these features and that will be presented are in-depth profiling of multi-layer samples and the elemental analysis of biological materials.  相似文献   

13.
A proposal for dichroic experiments in the electron microscope   总被引:1,自引:0,他引:1  
Building upon the similarities between inelastic electron scattering and X-ray absorption we show that dichroism can be observed in electron energy loss spectrometry (EELS) in the transmission electron microscope (TEM). Natural or magnetic linear dichroism can be studied in electron scattering experiment with definite wave vector transfer in the interaction.The detection of circular dichroism in the TEM relies on interferometric EELS in a particular scattering geometry that allows extraction of the mixed dynamic form factor from energy loss spectra. Similarities between dichroic signals in energy loss near edge structures and X-ray absorption near edge structures are discussed, and a new experimental setup for dichroic measurements in the TEM is proposed.  相似文献   

14.
Two standard commercial flashlamp-pumped Nd:YAG (YAG denotes yttrium aluminum garnet) lasers have been upgraded to "pulse-burst" capability. Each laser produces a burst of up to 15 2 J Q-switched pulses (1064 nm) at repetition rates of 1-12.5 kHz. Variable pulse-width drive (0.15-0.39 ms) of the flashlamps is accomplished by insulated gate bipolar transistor (IGBT) switching of electrolytic capacitor banks. Direct control of the laser Pockels cell drive enables optimal pulse energy extraction, and up to four 2 J laser pulses during one flashlamp pulse. These lasers are used in the Thomson scattering plasma diagnostic system on the MST reversed-field pinch to record the dynamic evolution of the electron temperature profile and temperature fluctuations. To further these investigations, a custom pulse-burst laser system with a maximum pulse repetition rate of 250 kHz is now being commissioned.  相似文献   

15.
A molecular beam apparatus has been developed for deposition and scattering experiments of size-selected clusters. The new setup combines a bimetallic laser ablation cluster source with a collinear time-of-flight mass spectrometer. Mass selection is achieved with a pulsed electrostatic mirror. A significantly improved transmission in combination with a reduction of the kinetic energy distribution of the mass selected clusters has been obtained. Without further modification of the apparatus, surface-induced dissociation of mass selected tin clusters has been investigated, demonstrating the possibility to combine cluster beam deposition and scattering experiments.  相似文献   

16.
The recent upgrade to the MAST YAG Thomson scattering while enhancing the diagnostic capabilities increased the complexity of the system. There are eight YAG lasers now operational, doubling the number from the previous setup. This means alignment between each laser individually and reference points is essential to guarantee data quality and diagnostic reliability. To address this issue an alignment system was recently installed. It mimics the beams alignment in MAST by sampling 1% of the laser beam that is sent into a telescope which demagnifies by a factor of 8. The demagnified beam is viewed with a CCD camera. By scanning the camera the profile and position of the beams in the scattering zone and in a range of several meters inside MAST can be determined. Therefore alignment is checked along the beam path without having to sample it inside the vessel. The experimental apparatus and test procedures are described.  相似文献   

17.
A time-of-flight electron velocity spectrometer using two transverse electric field deflectors as fast electronic shutters has been constructed. Square-wave voltage pulses applied to the two shutters limit the transmitted current to electrons in selected narrow velocity ranges. Analysis of the magnitude of this transmitted electron current as a function of the time delay between the two shutter openings leads to the electron velocity or energy spectrum in the incident charged particle beam. Time resolutions of 5 ns (FWHM) can be obtained with the present apparatus for electrons in the 5-100 eV range.  相似文献   

18.
The results of the excitation of СdS semiconductor targets by a subnanosecond electron beam (EB) with an electron energy of 60–230 keV are presented. The maximum intensity of laser radiation from targets for a 1-mm EB diameter exceeded 107 W/cm2 at an efficiency of ~10%. Lasing was initiated at the leading edge of the EB current; laser radiation then reproduced the shape of the excitation pulse. At low excitation levels, a single-mode lasing regime with the wavelength λ = 522 nm was observed. The maximum power of laser radiation (10 MW) was achieved on a multielement CdS semiconductor target. The duration of laser pulses changed in the range of 100–500 ps.  相似文献   

19.
In order to obtain the angular dependent electron energy distributions, we developed a multichannel electron spectrometer (MCESM) with high energy and angular resolutions. The MCESM consists of seven small electron spectrometers set in every 5° on the basement, each of which detection range is up to 25 MeV. In the experiment, we successfully obtained electron spectra from imploded cone-shell target as well as gold plane target irradiated by ultraintense (300 J/5 ps) laser beam.  相似文献   

20.
The differential scattering cross section in electron energy loss near edge spectroscopy (ELNES) generally depends on the orientation of the Q wave vector transferred from the incident electron to an atomic core electron. In the case where the excited atom belongs to a threefold, fourfold or sixfold main rotation axis, the dipole cross section depends on the angle of Q with respect to this axis. In this paper, we restrict to this situation called dichroism. Furthermore, if we take into account the relativistic effects due to the high incident electron velocity, this dipole cross section also depends on the angle of Q with respect to the electron beam axis. It is due to these dependences that the shape of measured electron energy loss spectra varies with the electron beam incidence, the collector aperture, the incident beam convergence and the incident electron energy. The existence of a particular beam incidence angle for which the scattering cross section becomes independent of collection and beam convergence semi-angles is clearly underscored. Conversely, it is shown that EELS spectra do not depend on the beam incidence angle for a set of particular values of collection and convergence semi-angles. Particularly, in the case of a parallel incident beam, there is a collection semi-angle (often called magic angle) for which the cross section becomes independent of the beam orientation. This magic angle depends on the incident beam kinetic energy. If the incident electron velocity V is small compared with the light velocity c, this magic angle is about 3.975theta(E) (theta(E) is the scattering angle). It decreases to 0 when V approaches c. These results are illustrated in the case of the K boron edge in the boron nitride.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号