共查询到20条相似文献,搜索用时 203 毫秒
1.
针对目前锰矿中高含量锰的测定分析技术流程复杂,本文对常用的混合酸溶样品前处理方式进行优化,运用电感耦合等离子体发射光谱法(ICP-OES)技术手段的分析方法和国标方法 GB/T 1506-2016锰矿石硫酸亚铁铵滴定法对标准物质和高含量样品的结果进行比较验证。发现ICP-OES测定时未有谱线干扰,精密度和准确度在合理范围内,用酸溶法溶矿ICP-OES测定方法可以准确测定锰矿石中高含量的锰元素。 相似文献
2.
3.
文章研究了用电感耦合等离子体-原子发射光谱法(ICP-OES)测定岩石矿物中的锡的方法。实验考察了称样量及其溶解的方法,选择了恰当的分析线波长,确定了仪器工作条件,对方法的准确度及精密度进行了考察。 相似文献
4.
采用重量法和电感耦合等离子体发射光谱法(ICP-OES法)对复合肥料的有效磷含量进行测定,并对测量不确定度进行评定和比较。重量法测定结果w(有效磷)(20.71±0.07)%,扩展不确定度为0.07%(k=2),其不确定度主要来源于样品测量重复性;ICP-OES法测定结果w(有效磷)为(20.74±0.67)%,扩展不确定为0.67%(k=2),其不确定度主要来源于系列标准溶液的稀释。相比于ICP-OES法,重量法测定准确度更高,更稳定,适用于对准确度要求较高的测定;ICP-OES法适用于大批量测定。 相似文献
5.
6.
7.
目前氟化铝YS/T581系列分析标准中没有氧化钙含量测定的方法,氟化铝中氧化钙含量比较低,低含量的钙元素必须用仪器进行测定,适用的方法有原子吸收分光光度法、MP-AES法、ICP-OES法。本文对比这几种方法的优缺点,建立了一种能够高效、准确、低成本地测定氟化铝中低含量氧化钙的方法。综合各种因素比较,最终选择合适的样品前处理方法,将氟化铝完全转化可溶性盐溶液,用微波等离子体光谱仪(MP-AES)法检测溶液中钙元素含量,计算氟化铝中氧化钙的含量。结果表明,该方法具有检出限低、稳定性好、准确度高、工作效率高、成本相对低等优势。 相似文献
8.
采用电感耦合等离子体发射光谱仪(ICP-OES)用内标法测定滑石中钙、镁、铁和铝含量。将试样经硫酸和氢氟酸溶解,盐酸提取,定容摇匀,分液加内标后,用ICP-OES直接测定。经实验测试结果的比对,结果准确、可靠,而且测量结果的精密度好,准确度高。该方法操作简单、准确、适合批量同时测定滑石中钙、镁、铁、铝的分析要求。 相似文献
9.
10.
采用盐酸—硝酸溶解,盐酸提取,利用电感耦合等离子体发射光谱(ICP-OES)法,通过对射频功率、分析谱线和观测方式的优选,无需基体匹配,即可实现煤系硫铁矿中铜、铅、锌的快速测定;该方法具有准确度高、重复性好、可多元素快速测定等优点。 相似文献
11.
微波消解-ICP-OES法测定人造革合成革中重金属元素的含量 总被引:1,自引:0,他引:1
应用具有温度、压力监控功能的高通量微波化学工作站,使人造革合成革样品在硝酸-氢氟酸-过氧化氢混合酸体系中充分消解,以硼酸消除过量氟离子的影响,采用电感耦合等离子体发射光谱法(ICP-OES)测定样品中Pb、Cd、Cr、Cu、Sb等重金属元素的含量。结果表明:优化微波消解条件和ICP-OES分析条件后,检出限为0.0019~0.0430g/ml,3种浓度水平的平均回收率在88.5%~102.8%之间,相对标准偏差小于6.3%;该方法操作简便,多种元素可同时测定,检出限低,线性范围宽,干扰小,并具有良好的准确度和精密度,适用于人造革合成革中重金属元素的日常检测。 相似文献
12.
13.
14.
电解铜溶液中游离酸的测定,采用亚铁氰化钾沉淀分离、EDTA-钙盐掩蔽、碘化钾-草酸盐掩蔽、草酸钠掩蔽法进行比较。着重对草酸钠掩蔽法进行了共存离子干扰、精密度考察,加标回收率〉98%。试验表明,草酸钠掩蔽法用于电解铜溶液中游离酸的测定,操作简便、快速、精密度、准确度可满足生产要求。 相似文献
15.
16.
Acid absorption is a routine analytical method used in the manufacturing of lead oxide, that is, then further used to manufacture Pb-acid battery electrodes. This study had a new look at the definition of acid absorption being an indication of the acid reactivity of the oxide forming certain lead sulphate-related phases. Quantitative powder X-ray diffraction analysis of the acid reaction products showed there were significant differences in the phases formed that could be related to the amount of acid used in the acid absorption test. The study also showed that there were significant changes in the surface area of the oxides once they had reacted with the acid, where a traditionally slow reacting oxide such as β-PbO would show the greatest increase in material surface area once reacted with the acid. The accuracy of the method used by various laboratories was also studied by comparing the results obtained from two different methods and from three different laboratories. The results showed that there were significant differences between the reported values, and that one should with caution compare acid absorption numbers obtained from different laboratories. 相似文献
17.
18.
采用四苯硼钠电位滴定法测定阳离子褐煤树脂的阳离子度.通过消除测定方法的离子干扰、优化四苯硼钠电位滴定法的测定条件来提高测定方法的准确度.采用5%盐酸溶液提取阳离子腐植酸,去除钾离子和其他水溶性杂质;四苯硼钠电位滴定过程中,提纯后阳离子腐植酸加入量为0.5g,用0.2%氢氧化钠溶液溶解阳离子腐植酸,在pH 10.0条件下,选用甘汞电极为参比电极,氟硼酸根离子选择性电极为指示电极,用十六烷基三甲基溴化铵标准溶液电位滴定四苯硼钠,电位突变约200 ~300 mV,加标回收率达95%,满足分析测试的要求.实验结果表明,该方法选择性好、准确性高、易于操作,具有较高的推广应用价值. 相似文献
19.
Customary method of determining iron oxide and titania from ignited R2O2 precipitate requires considerable time. Direct titration of fusions with sodium carbonate is impossible because of gelatinous silica. Direct titration of fusions with potassium bisulphate is accurate with clays low in silica and unfired clays. By treating with hydrofluoric and sulphuric acid, and dissolving with dilute hydrochloric and precipitating the R2O2 by ammonium hydroxide and then fusing with potassium bisulphate the iron and titanium oxide can with accuracy be titrated. A detail method of procedure is given. 相似文献