DO对短程同步硝化反硝化除磷工艺的影响   总被引:1,自引:0,他引:1  
针对碳源偏低的城市污水,采用序批式活性污泥法研究D0对短程同步硝化反硝化除磷工艺的影响,同时对短程同步硝化反硝化和反硝化除磷的机理进行探讨。试验表明:控制DO浓度可在同一个反应器内既实现短程同步硝化反硝化反应又达到反硝化除磷的效果。综合考虑COD、NHg—N、TN、TP的出水浓度达到一级A排放标准,得出最佳的D0控制范围。当D0浓度在0.5~1.0mg/LU时.COD的去除率达到93%~94%,Nil,+一N的去除率为97%~98%,TN的去除率达到85%一96%,TP的去除率为91%~93%。  相似文献   

2.
The objective of this study was to develop an integrated nitrogen treatment system using autotrophic organisms. A treatment system consists of an aerobic hollow-fiber membrane biofilm reactor (HfMBR) and anaerobic HfMBR. In the aerobic HfMBR, a mixture gas of air and O2 was supplied through the fibers for nitrification. Denitrification occurred in the anaerobic HfMBR using H2 as the electron donor. The treatment system was continuously operated for 190 days. NH4-N removal efficiencies ranging from 95% to 97% were achieved at NH4-N concentrations of influent ranging from 50 to 100 mg N/L. When glucose was added to the influent, the simultaneous nitrification and denitrification occurred in the aerobic HfMBR, and nitrogen removal rates were changed according to the COD/NH4-N ratio of influent. In the anaerobic HfMBR, autotrophic denitrification using H2 occurred and the removal rates achieved in this study were 23-58 mg N/m2 d. In this study, the achieved removal efficiency was lower than other study findings; however, the result suggested that this hybrid HfMBR system can be used effectively for nitrogen removal in oligotrophic water.  相似文献   

3.
The use of a membrane bioreactor (MBR) for removal of organic substances and nutrients from slaughterhouse plant wastewater was investigated. The chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) concentrations of slaughterhouse wastewater were found to be approximately 571 mg O2/L, 102.5 mg/L, and 16.25 mg PO4-P/L, respectively. A submerged type membrane was used in the bioreactor. The removal efficiencies for COD, total organic carbon (TOC), TP and TN were found to be 97, 96, 65, 44% respectively. The COD value of wastewater was decreased to 16 mg/L (COD discharge standard for slaughterhouse plant wastewaters is 160 mg/L). TOC was decreased to 9 mg/L (TOC discharge standard for slaughterhouse plant wastewaters is 20 mg/L). Ammonium, and nitrate nitrogen concentrations of treated effluent were 0.100 mg NH4-N/L, and 80.521 mg NO3-N/L, respectively. Slaughterhouse wastewater was successfully treated with the MBR process.  相似文献   

4.
CASS工艺生物脱氮除磷效果分析   总被引:2,自引:0,他引:2  
对CASS工艺脱氮除磷效果进行了试验研究,重点研究了温度和回流比对脱氮效果的影响,曝气量对除磷效果的影响。研究结果表明,水温在30℃时系统脱氮效果最好,此时NH3-N去除率在80%左右,TN去除率在70%左右;污泥回流比为25%、50%、100%和200%时,TN去除率分别为50%、58%、62%和70%,增加回流比可以提高脱氮效率;好氧区DO维持在2mg/L和4 mg/L时,TP去除率分别为82%和37%。  相似文献   

5.
土壤过滤系统处理农村生活污水的 试验研究   总被引:1,自引:0,他引:1  
采用一种土壤过滤系统处理农村生活污水,考察了该工艺对CODCr、BOD5、NH3-N、全氮(TN)和全磷(TP)的去除效果。实验结果表明,当水力负荷约为0.05 m3/(m2·d), 水力停留时间为3 d时。该土壤过滤系统对CODCr、BOD5、NH3-N、全氮(TN)和全磷(TP)的去除效果较好,平均去除率分别达到84.6%、83.3%、64.3%、59.8%和70%。出水CODCr约为18.3~42.1 mg/L,BOD5约为8.9~17.3 mg/L,NH3-N约为11.2~17.7 mg/L,TN约为21.2~31.3 mg/L,TP小于2.0 mg/L,出水水质优于农田灌溉水质标准(GB 5084—2005)。气温变化和进水污染物浓度对处理效果影响明显。总体上来讲,温度大于22 ℃时,进水污染物浓度越低处理效果越好。  相似文献   

6.
曝气生物滤池去除有机物及氨氮的影响因素分析   总被引:4,自引:0,他引:4  
采用以陶粒为填料的曝气生物滤池(BAF)处理生活污水,研究气水比、水力负荷、进水COD和NH3-N负荷对BAF去除COD及NH3-N的影响,分析COD及NH3-N沿滤柱的变化规律。结果表明:当试验进水COD及NH3-N质量浓度分别为300~370mg/L和20~40mg/L时,最佳气水比为4∶1~5∶1,最佳水力负荷为1.0~2.0 m3/(m2.h)。当进水COD负荷为1.69~6.47 kg/(m3.d)时,COD去除率与进水COD负荷成正相关。BAF的硝化性能与进水NH3-N和COD负荷成负相关。  相似文献   

7.
The feasibility of combining a previously reported storage driven denitrification biofilm, where 80% of influent acetate can be converted to poly-beta-hydroxybutyrate (PHB), with a suitable nitrification reactor, either submerged or trickling filter design, to achieve complete biological nitrogen removal was tested. The reactor system showed the potential of complete biological nitrogen removal of waste streams with a C/N ratio as low as 3.93 kg COD/kg N-NH3 at an overall nitrogen removal rate of 1.1 mmole NH3/L/h. While the efficiency and the rates of nitrogen removal were higher than what is observed in traditional or simultaneous nitrification and denitrification (SND) systems, there were two problems that require further development: (a) the incomplete draining of the reactor caused ammonia retention and release in the effluent, limiting the overall N-removal and (b) pH drifts in the nitrification step slowed down the rate of nitrification if not corrected by appropriate pH adjustment or buffering.  相似文献   

8.
In this study, four similar bench-scale submerged Anoxic/Oxic Membrane Bioreactors (MBR) were used simultaneously to investigate the effects of solids retention time (SRT) on organic and nitrogen removal in MBR for treating domestic wastewater. COD removal efficiencies in all reactors were consistently above 94% under steady state conditions. Complete conversion of NH(4+)-N to NO(3-)-N was readily achieved over a feed NH(4+)-N concentration range of 30 to 50 mg/L. It was also observed that SRT did not significantly affect the nitrification in the MBR systems investigated. The average denitrification efficiencies for the 3, 5, 10 and 20 days SRT operations were 43.9, 32.6, 47.5 and 66.5%, respectively. In general, the average effluent nitrogen concentrations, which were mainly nitrate, were about 22.2, 27.6, 21.7 and 13.9 mg/L for the 3, 5, 10 and 20 days SRT systems, respectively. The rate of membrane fouling at 3 days SRT operation was more rapid than that observed at 5 days SRT. No fouling was noted in the 10 days and 20 days SRT systems during the entire period of study.  相似文献   

9.
The performance of aerobic submerged packed bed reactors was studied for the treatment of domestic wastewater using different kinds of packing materials with high specific areas (760-1,200 m(2)/m(3)). The tested materials were ceramic spheres, crushed tezontle, grains of high density polyethylene (HDPE), of low density polyethylene (LDPE) and of polypropylene (PP), cubes of polyurethane (PU) and polyethylene tape (SESSIL). The bioreactors were operated in continuous regime, applying organic loads in the range of 0.8-6.0 g COD.m(-2).d(-1). The obtained specific COD removal rates were very similar in all the reactors when they were operated at organic loads up to 2.0 g COD.m(-2).d(-1), after which differences in effectiveness appeared and the best results were determined in the reactors with SESSIL, LDPE and PU. Very low TSS, O&G and turbidity were obtained in all the effluents. The NH(3)-N and TN removals were dependent on the dissolved oxygen (DO) concentration and the removals at DO of 5 mg/l were 84-99% and 61-74% respectively. The best removals were determined in the reactors with PU, SESSIL and LDPE. The reactor with tezontle had also a good performance when operated with loads up to 1.0 g TN.m(-2).d(-1). The best phosphate removals (38-49%) were obtained in the reactors with PU, tezontle, ceramic sheres and SESSIL.  相似文献   

10.
A study has been carried out to define the effect of drastic temperature changes on the performance of lab-scale hollow-fibre MBR in treating municipal wastewater at a flux of 10 L m(-2) h(-1) (LMH). The objectives of the study were to estimate the activated sludge properties, the removal efficiencies of COD and NH(3)-N and the membrane fouling tendency under critical conditions of drastic temperature changes (23, 33, 42 & 33 °C) and MLSS concentration ranged between 6,382 and 8,680 mg/L. The study exhibited that the biomass reduction, the low sludge settleability and the supernatant turbidity were results of temperature increase. The temperature increase led to increase in SMP carbohydrate and protein, and to decrease in EPS carbohydrate and protein. The BRE of COD dropped from 80% at 23 °C to 47% at 42 °C, while the FRE was relatively constant at about 90%. Both removal efficiencies of NH(3)-N trended from about 100% at 33 °C to less than 50% at 42 °C. TMP and BWP ascended critically with temperature increase up to 336 and 304 mbar respectively by the end of the experiment. The values of suspended solids (SS) and the turbidity in the final effluent were negligible. The DO in the mixed liquor was varying with temperature change, while the pH was within the range of 6.7-8.3.  相似文献   

11.
利用垂直潜流人工湿地单元模型探讨COD、TN和NH4+-N质量浓度在一昼夜之中随时间及深度的变化规律。结果表明:垂直潜流人工湿地中污染物去除率的变化呈一定的周期性,昼夜差距较大。COD、NH4+-N和TN的去除率在15:00达到最大,夜间最小。COD和NH4+-N质量浓度在表层(距湿地底部60~90cm段)迅速降低,底部变化幅度较小。TN浓度沿程的降低趋势很明显。湿地中COD、NH4+-N和TN质量浓度的变化趋势与DO显著相关,DO质量浓度越高,越有利于有机物和氮的去除。  相似文献   

12.
A laboratory-scale fluidized-bed reactor with an external aeration loop was used for nitrification of high-strength ammonium wastewater (up to 500 mg NH4-N/L). The results demonstrated that the system is capable of handling ammonium removal rates of up to 2.5 kg NH4-N/m3 x d, while removal efficiencies were as high as 98% and independent of the applied ammonium loading rates. Ammonium loading rates higher than 2.5 kg NH4-N/m3 x d resulted in decreased ammonium removal efficiency. The data show that near complete ammonium removal occurred at DO concentrations as low as 0.3-0.5 mg/L. However, the nitrite-nitrogen fraction in the effluent increased from 3.5% to 23.2% when the DO dropped from 1.0 mg/L to approximately 0.4 mg/L, respectively. The high specific removal rates in this system are one order of magnitude higher than that of suspended-growth systems. This can reduce the supplementary reactor volumes required for nitrification to less than 10% of that needed in conventional activated sludge systems. These results clearly indicate the potential economic gains that could be achieved through implementation of this technology.  相似文献   

13.
固定化光合细菌对水体富营养化的去除效果   总被引:6,自引:0,他引:6  
为了探索对富营养化水体的微生物修复方法,采用固定化光合细菌进行人工模拟的富营养化水体处理试验。试验结果表明,接种固定化光合细菌比对照可明显地降低水体中的养分。19d的处理时间,TN、NH4-N、NO3-N、TP和COD的去除率分别达到了65.94%,79.84%,78.80%,62.95%,78.06%,并且接种光合细菌对水体中的藻类也起到一定的抑制作用。接种光合细菌增加了水体的DO和pH值,同时也提高了硝化率以及光合细菌数,而水体中这些因素的变化都与水体中养分的去除效果密切相关。因此富营养化水体修复中接种固定化光合细菌可以起到去除养分的目的。  相似文献   

14.
Nitrogen removal from a piggery wastewater was investigated in a post-denitrification modified Lüdzack Ettinger (PDMLE) process. Overall hydraulic retention time (HRT) of the PDMLE, consisting of contact/separator (C/S), nitrification, denitrification and re-aerobic bioreactor was 10 days. 60% of the influent SCOD was separated in the C/S by contacting the return sludge with the synthetic wastewater, however, only 10% of the influent SCOD was separated from the piggery wastewater. Biosorption capacities of the synthetic wastewater and piggery wastewater were 800 and 150 mg/g-MLSS, respectively. In spite of the high organic and nitrogen load, nitrification efficiency was above 95%, and nitrification rate was about 180 mg-NH4+-N/L x day. The removed delta COD/delta nitrate ratios in the denitrification tank were 4.0 and 11.5 g-SCOD/g-nitrate, while denitrification rates were 8.4 and 2.6 mg-nitrate/day for synthetic and piggery wastewater, respectively. In the proposed PDMLE process, both bio-sorbed and bypassed organic matter could be successfully used for nitrate reduction as carbon sources and the final TN removal efficiency was as high as 95%.  相似文献   

15.
An activated sludge/biofilm hybrid process treating municipal wastewater was studied in pilot plant trials. A new type of suspended carrier, with large effective surface area, was employed in the process with the aim of enhancing nitrification. The pilot plant was operated for 1.5 years in five different configurations including pre-denitrification in all five and enhanced biological phosphorus removal in the final two. The wastewater temperature ranged between 11 degrees C and 20 degrees C, and the nominal dissolved oxygen (DO) level was 5-6 mg/L. The nitrification rate obtained on the new carrier within the hybrid stage was in the range of 0.9-1.2 g NH4-N/m2/d corresponding to a volumetric rate of 19-23 g NH4-N/m3/h (total nitrification including nitrification in the suspended solids). More than 80% of the total nitrification took place on the carrier (and the remainder in the suspended solids). The nitrification rate was shown to correlate with DO, decreasing when the DO was decreased. The results supported the idea of using the new carrier as a tool to upgrade plants not having nitrification today or improve nitrification in activated sludge processes not reaching necessary discharge levels. The large surface area present for nitrification makes it possible to obtain high nitrification rates within limited volumes. The possibility to keep the total suspended solid content low (< 3 g/L) and avoiding problems with the filament Microthrix parvicella, are other beneficial properties of the hybrid process.  相似文献   

16.
The objective of this research was to include ozonation prior to an activated sludge treatment and investigate the effect on the nitrogen species, their fate and the consequences of this oxidation upon the biomass. Three parallel treatment systems were used: the base system, where feed went directly to the activated sludge reactor, and two others, where the influent was ozonated at two different dosages, 15 and 25 mg/L of influent, prior to the biological reactors. The results from the ozonation chamber show a high oxidation capacity of the entering ammonia and organic nitrogen, proportional to the ozone dose. The oxidation product was nitrate. No de-nitrification was expected because a high oxygen concentration (4 mg/L) was maintained in the reactors. The reactors receiving ozonated influent showed a lower assimilation of nitrogen by the biomass. The sludge nitrogen content resulted in 11, 9.3 and 7.4% dry-weight corresponding to no-ozone, low ozone and high ozone dosages, respectively. In spite of the lower ammonia available in the ozonated flows, the corresponding reactors showed a higher specific nitrification rate. The ozonated system also performed better in terms of chemical oxygen demand (COD) and biochemical oxygen demand (BOD5) removals, besides showing a higher true biomass yield coefficient.  相似文献   

17.
Three parallel biological anoxic filters (BaFs) were operated to investigate the denitrification kinetics of methanol, brewery wastewater and bakery wastewater. The experiment was conducted within the temperature range of 15-20 °C, with an influent nitrate and carbon dosage of 30 mg/L and 150 mg COD/L (COD: chemical oxygen demand). The denitrification efficiencies of brewery wastewater, bakery wastewater and methanol were 84, 66 and 74%, specific denitrification rates were 1.44, 1.11 and 1.24 kg NO(3)-N/m(3) d, and total nitrogen (TN) removal rates were 74, 62 and 66%, respectively. The volatile attached solid (VAS) tests reveal that methanol has the minimum net biomass yield, so it needs the least carbon to nitrogen (expressed in COD to nitrate, C/N) ratio for complete denitrification. While the brewery wastewater and bakery wastewater need higher C/N ratio to remove all nitrate nitrogen, and they both may need pretreatment to remove phosphate when used as external carbon sources.  相似文献   

18.
Pre-denitrification in biofilters is limited by the amount of easily degradable organic substrate, resulting in relatively high requirements for external carbon. The combination of pre-DN, N and post-DN filters is much more advisable for most municipal wastewaters, because the recycle rate can be reduced and external carbon can be saved. For minimum use of external carbon, 100-150% recycle rate should not be exceeded. Then, approximately 50-60% of the total NO3-N can be depleted in the pre-DN stage. On average, 10 g total (t) COD/g NO3-N were required in the pre-DN stage for denitrification in the pilot and full-scale plant and 0.4-0.5 kg NO3-N/(m(3)DN d) can be reached without external carbon. As only 40-70% of the COD load is eliminated in the pre-DN, the remaining COD load is removed in the nitrification stage. 1 kg COD/(m(3) d) suppresses nitrification rates by approximately 0.1 kg NH4-N/(m(3) d). For nitrification rates, > 0.5 kg NH4N/(m(3) d) at 12 degrees C not more than 2 kg COD/(m(3) d) may be eliminated in the nitrification.  相似文献   

19.
The performance of an ultra-compact biofilm reactor (UCBR) treating domestic wastewater (DWW) collected from a local water reclamation plant; and gradually shifting to a mono-type carbon source synthetic wastewater (SWW) combined with DDW (CWW) and finally SWW; was investigated in this study. The total COD concentrations of influent DWW and CWW/SWW were 413.6 ± 80.8 mg/L and 454.9 ± 51.3 mg/L, respectively. The UCBR was able to achieve average total COD removal efficiencies of 70 ± 10% and 80 ± 4% for DWW and SWW respectively. The total COD concentrations of the effluent of DWW and CWW/SWW were 122.5 ± 44.4 mg/L and 89.7 ± 10.3 mg/L, respectively. These observations suggested that heterotrophs in the UCBR system were able to better assimilate and remove carbon of mono-type SWW compared to diverse carbon sources such as DWW; although the influent soluble COD concentrations of the SWW were higher than those of the DWW. However, the effluent NH(4)(+)-N concentrations for both types of wastewater were rather similar, <3.0 mg/L; although the influent NH(4)(+)-N concentrations of the DWW were 1.5 times those of the SWW.  相似文献   

20.
Pumped flow biofilm reactors (PFBR) for treating municipal wastewater   总被引:1,自引:0,他引:1  
A novel laboratory bench-scale sequencing batch biofilm reactor (SBBR) system was developed for the treatment of synthetic domestic strength wastewater, comprising two side-by-side 18 l reactor tanks, each containing a plastic biofilm media module. Aerobic and anoxic conditions in the biofilms were effected by intermittent alternate pumping of wastewater between the two reactors. With a media surface area loading rate of 4.2 g chemical oxygen demand (COD)/m2.d, the average influent COD, total nitrogen (TN) and ammonium-nitrogen (NH4-N) concentrations of 1021 mg/l, 97 mg/l and 54 mg/l, respectively, reduced to average effluent concentrations of 72 mg COD/l, 17.8 mg TN/l, and 5.5 mg NH4-N /l. Using a similar alternating biofilm exposure arrangement, a 16 person equivalent pilot (PE) plant was constructed at a local village treatment works to remove organic carbon from highly variable settled municipal wastewater and comprised two reactors, one positioned above the other, each containing a module of cross-flow plastic media with a surface area of 100 m2. Two different pumping sequences (PS) in the aerobic phase were examined where the average influent COD concentrations were 220 and 237 mg/l for PS1 and PS2, respectively, and the final average effluent COD was consistently less than 125 mg/l--the European Urban Wastewater Treatment Directive limit--with the best performance occurring in PS1. Nitrification was evident during both PS1 and PS2 studies. A 300 PE package treatment plant was designed based on the bench-scale and pilot-scale studies, located at a local wastewater treatment works and treated municipal influent with average COD, suspended solids (SS) and TN concentrations of 295, 183 and 15 mg/l, respectively resulting in average effluent concentrations of 67 mg COD/l, 17 mg SS/l and 9 mg TN/l. The SBBR systems performed well, and were simple to construct and operate.  相似文献   