1.
In the present study, the effect of the opening size and building direction on night hours thermal comfort in a naturally ventilated rural house is investigated. Initially, the airflow in and around the building is simulated using a validated computational fluid dynamics (CFD) model. Local climate night-time data (wind velocity and direction, temperature and relative humidity) are recorded in a weather station and the prevailing conditions are imposed in the CFD model as inlet boundary conditions. The produced airflow patterns are then used to evaluate indoor thermal comfort. For this reason, special thermal comfort indices, i.e. the well-known predicted mean vote (PMV) index and its modifications especially for natural ventilation, are calculated with respect to various residential activities. Mean values of these indices (output variables) within the occupied zone are calculated for different combinations of opening sizes and building directions (input variables), to generate a database of input–output pairs. Finally, the database is used to train and validate Radial Basis Function Artificial Neural Network (RBF ANN) input–output “meta-models”. It is demonstrated that the proposed methodology leads to reliable thermal comfort predictions, while the optimum design variables are easily recognized.  相似文献   

2.
Parametric studies of facade designs for naturally ventilated residential buildings in Singapore were carried out to optimize facade designs for better indoor thermal comfort and energy saving. Two criteria regarding indoor thermal comfort for naturally ventilated residential buildings are used in this study. To avoid the perception of thermal asymmetry, temperature difference between mean radiant temperature and indoor ambient air temperature should be less than 2 °C [F.A. Chrenko, Heated ceilings and comfort. J. Inst. Heat. Ventilating Eng. 20 (1953) 375–396; F.A. Chrenko, Heated ceilings and comfort. J. Inst. Heat. Ventilating Eng. 21 (1953) 145–154]. Thermal comfort regression model for naturally ventilated residential buildings in Singapore was used to evaluate various facade designs either. Facade design parameters: U-values, orientations, WWR (window to wall ratio) and shading device lengths are considered in the investigation. The building simulation results for a typical residential building in Singapore indicated that the U-value of facade materials for north and south orientations should be less than 2.5 W/m2 K and the U-value of facade materials for north and south orientations should be less than 2 W/m2 K. From the coupled simulation results, it was found that the optimum window to wall ratio is equal to 0.24. Optimum facade designs and thermal comfort indexes are summarized for naturally ventilated residential buildings in Singapore.  相似文献   

3.
Ye XJ  Zhou ZP  Lian ZW  Liu HM  Li CZ  Liu YM 《Indoor air》2006,16(4):320-326
A long-term field investigation was carried out in naturally ventilated residential buildings in Shanghai from April 2003 to November 2004. A total of 1,768 returned questionnaires were collected in the study. This study deals with the thermal sensation of occupants in naturally ventilated buildings and the change in thermal neutral temperature with season. The range of accepted temperature in naturally ventilated buildings is between 14.7 degrees C T(op) and 29.8 degrees C T(op). The results also report the findings of the adaptive comfort model in Shanghai that determines the adaptive relationship of neutral temperature with outdoor air temperature. A long-term field study was carried out in residential buildings in Shanghai to find the relationship between thermal sensation, indoor neutral temperature and outdoor temperature. This paper presents findings of thermal comfort and discusses the more sustainable standard for the indoor climate of residential buildings in Shanghai.  相似文献   

4.
In the ASHRAE comfort database [1], underpinning the North American naturally ventilated adaptive comfort standard [2], the mean indoor air velocity associated with 90% thermal acceptability was relatively low, rarely exceeding 0.3 m/s. Post hoc studies of this database showed that the main complaint related to air movement was a preference for ‘more air movement’ 3 and 4. These observations suggest the potential to shift thermal acceptability to even higher operative temperature values, if higher air speeds are available. If that were the case, would it be reasonable to expect temperature and air movement acceptability levels at 90%? This paper focuses on this question and combines thermal and air movement acceptability percentages in order to assess occupants. Two field experiments took place in naturally ventilated buildings located on Brazil’s North-East. The fundamental feature of this research design is the proximity of the indoor climate observations with corresponding comfort questionnaire responses from the occupants. Almost 90% thermal acceptability was found within the predictions of the ASHRAE adaptive comfort standard and yet occupants required ‘more air velocity’. Minimum air velocity values were found in order to achieve 90% of thermal and air movement acceptability. From 24 to 27 °C the minimum air velocity for thermal and air movement acceptability is 0.4 m/s; from 27 to 29 °C is 0.41–0.8 m/s, and from 29 to 31 °C is >0.81 m/s. These results highlight the necessity of combining thermal and air movement acceptability in order to assess occupants’ perception of their indoor thermal environment in hot humid climates.  相似文献   

5.
The objective of this study was to develop an adaptive thermal comfort equation for naturally ventilated buildings in hot-humid climates. The study employed statistical meta-analysis of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) RP-884 database, which covered several climatic zones. The data were carefully sorted into three climate groups including hot-humid, hot-dry, and moderate and were analyzed separately. The results revealed that the adaptive equations for hot-humid and hot-dry climates were analogous with approximate regression coefficients of 0.6, which were nearly twice those of ASHRAE and European standards 55 and EN15251, respectively. The equation using the daily mean outdoor air temperature had the highest coefficient of determination for hot-humid climate, compared with other mean temperatures that considered acclimatization of previous days. Acceptable comfort ranges showed asymmetry and leaned toward operative temperatures below thermal neutrality for all climates. In the hot-humid climate, a lower comfort limit was not observed for naturally ventilated buildings, and the adaptive equation was influenced by indoor air speed rather than indoor relative humidity. The new equation developed in this study can be applied to tropical climates and hot-humid summer seasons of temperate climates.  相似文献   

6.
The impacts of various ventilation strategies and facade designs on indoor thermal environment for naturally ventilated residential buildings in Singapore are investigated in this study based on thermal comfort index. Four ventilation strategies, nighttime-only ventilation, daytime-only ventilation, full-day ventilation and no ventilation were evaluated for hot-humid climate according to the number of thermal discomfort hours in the whole typical year on the basis of a series of TAS simulations. Parametric studies of facade designs on orientations, window to wall ratios and shading devices were performed for two typical weeks by coupled simulations between building simulation ESP-r and CFD (FLUENT). The results indicate that full-day ventilation for indoor thermal comfort is better than the other three ventilation strategies. With various facade design studies, it was found that north- and south-facing facades can provide much comfortable indoor environment than east- and west-facing facades in Singapore. It is recommended that optimum window to wall ratio 0.24 can improve indoor thermal comfort for full-day ventilation and 600 mm horizontal shading devices are needed for each orientation in order to improve thermal comfort in further.  相似文献   

7.
2008年夏季对广州某高校学生在自然通风建筑中进行了501人次的热舒适现场调查,调查内容包括热感觉、热舒适度、热可接受度及潮湿感,并对相应的室内干球温度、相对湿度、黑球温度和风速等热环境参数进行了测试记录。通过对数据的整理分析发现,自然通风建筑的夏季室内温湿度均高于ASHRAE标准的舒适区域,但人们对该环境有较好的适应性。调查结果表明,我国湿热地区自然通风建筑的热中性温度为28.1℃(ET*=29.3℃),可接受的热环境温度的上限为29.7℃(ET*=30.9℃),相对湿度上限为78%。  相似文献   

8.
Human responses to thermal environments in naturally ventilated (NV) buildings in hot-humid area of China were systematically investigated in the present study. Thirty local inhabitants long-time living in NV buildings participated in the study and reported their thermal sensations and perceptions and adaptive behaviors while all physical and personal variables were collected. Based on a year-long survey, a close match of indoor physical variables and occupants’ clothing insulation with outdoor climate was found as an important feature of NV buildings. Integrated indices can capture more thermal contexts in the NV buildings in hot-humid area of China than simple indices. Thermal sensation was found to be a good linear function of SET* with the thermal neutrality of 25.4 °C and the 90% (80%) acceptable range of 23.5–27.4 °C (22.1–28.7 °C) in SET*. The adaptive evidences were obtained for clothing adjustment, window opening and using fan respectively and the modified PMV model was validated to be applicable in NV buildings in hot-humid area of China with an expectancy factor of 0.822. Comparisons with other field studies indicate that people can develop various human-environment relationships through thermal adaptation to local climate, resulting in different thermal neutral temperatures in various climates. The subjects in hot-humid area of China are more acclimated and tolerable with hot and humid environments and more uncomfortable and intolerable with cold environments while compared with those in temperate climates.  相似文献   

9.
With the actual environmental issues of energy savings in buildings, there are more efforts to prevent any increase in energy use associated with installing air-conditioning systems. The actual standard of thermal comfort in buildings ISO 7730 is based on static model that is acceptable in air-conditioned buildings, but unreliable for the case of naturally ventilated buildings. The different field studies have shown that occupants of naturally ventilated buildings accept and prefer a significantly wider range of temperatures compared to occupants of air-conditioned buildings. The results of these field studies have contributed to develop the adaptive approach. Adaptive comfort algorithms have been integrated in EN15251 and ASHRAE standards to take into account the adaptive approach in naturally ventilated buildings. These adaptive algorithms seem to be more efficient for naturally ventilated buildings, but need to be assessed in field studies. This paper evaluates different algorithms from both static and adaptive approach in naturally ventilated buildings across a field survey that has been conducted in France in five naturally ventilated office buildings. The paper presents the methodology guidelines, and the thermal comfort algorithms considered. The results of application of different algorithms are provided with a comparative analysis to assess the applied algorithms.  相似文献   

10.
Numerical simulation of the indoor environment   总被引:1,自引:0,他引:1  
The CFD program VORTEX which has been developed for predicting the indoor environment in occupied spaces is described. The flow equations are the continuity equation, the Navier-Stokes equation, the thermal energy equation, the concentration equation and the equations for the kinetic energy of turbulence (k) and its dissipation rate () of the k- turbulence model. The equations are solved for the 3-D Cartesian system using the SIMPLE algorithm. The program produces a direct simulation of the thermal comfort indices PMV and PPD and the air quality of room air. Some applications involving mechanically ventilated (heating and cooling) and naturally ventilated rooms are presented. Results in the form of velocity vectors and contours for temperature, thermal comfort indices (PMV and PPD) and CO2 concentration are produced for the cases investigated. Simulations using this program can provide design data as required by thermal comfort and indoor air quality standards and guides.  相似文献   

11.
Y. Zhang  H. Chen  J. Wang  Q. Meng 《Indoor air》2016,26(5):820-830
We conducted a climate chamber study on the thermal comfort of people in the hot and humid area of China. Sixty subjects from naturally ventilated buildings and buildings with split air conditioners participated in the study, and identical experiments were conducted in a climate chamber in both summer and winter. Psychological and physiological responses were observed over a wide range of conditions, and the impacts of season, climate, and thermal history on human thermal comfort were analyzed. Seasonal and climatic heat acclimatization was confirmed, but they were found to have no significant impacts on human thermal sensation and comfort. The outdoor thermal history was much less important than the indoor thermal history in regard to human thermal sensation, and the indoor thermal history in all seasons of a year played a key role in shaping the subjects' sensations in a wide range of thermal conditions. A warmer indoor thermal history in warm seasons produced a higher neutral temperature, a lower thermal sensitivity, and lower thermal sensations in warm conditions. The comfort and acceptable conditions were identified for people in the hot and humid area of China.  相似文献   

12.
The equation for thermal comfort for buildings in the free-running mode (Annexe A2) in European Standard EN15251 rests on the data collected in the EU project Smart Controls and Thermal Comfort (SCATs). Many of these data were from naturally ventilated office buildings which were in free-running mode outside the heating season. Using the data from these buildings a relationship between indoor comfort and outdoor climate was developed for free-running buildings. This paper describes the data and the methods of analysis used to estimate the comfort conditions in the variable environment of free-running buildings. The paper also describes how the indoor comfort conditions were related to the running mean of the outdoor temperature, and addresses the effects of air movement and humidity. The paper considers the proportions of people likely to be comfortable if the temperature differs from the neutral temperature. The differences between the adaptive comfort charts in EN15251 and ASHRAE 55-2004 are discussed.  相似文献   

13.
Singapore has the hot and humid climate throughout the year. Many passive climate control methods are adopted in the naturally ventilated residential buildings to help achieve thermal comfort and reduce the energy consumption of air-conditioning. A field measurement and computational energy simulations were conducted to examine the effectiveness of commonly used passive climate control methods for these buildings. The effect of building orientation, façade construction, special roof system and window shading device on indoor thermal environment and cooling load was studied. The surface temperature of external wall and indoor thermal environment was measured to analyze the façade thermal performance. The cooling load was simulated to evaluate the effectiveness of various passive climate methods. Using the special roof system as thermal buffer is the most efficient method to reduce the room cooling load.  相似文献   

14.
The PMV model predicts thermal sensation well in HVAC buildings while it predicts a warmer thermal sensation than the occupants actually feel in naturally ventilated buildings. For using PMV model to predict thermal sensation well in a naturally ventilated building, the extended PMV model (PMVe) including an expectancy factor (e) and PMV was proposed by Fanger. Besides, calculations of PMV are too complex to be applied in practice. To obtain simple and applicable correlations, taking Qujing of Yunnan province, China, as example, a dry season (6-month) field measurement was conducted in a naturally ventilated residential room. Based on the collected data, PMVe values were calculated by using Newton’s iterative method. It is shown that the PMVe values approximately vary from −1.3 to 0.20 and the indoor thermal environment is somewhat discomfortable on some cloudy or rainy days. Parameters relationships and indoor air temperature gradients (vertical and horizontal) were also studied by using linear regression technique and quadratic polynomial fit technique. Numerous correlations with high relativities have been developed. It is convenient to use these results to evaluate the indoor thermal environment in naturally ventilated buildings under similar climatic conditions.  相似文献   

15.
本文采用自动记录仪,对厦门某海滨住宅夏季自然通风与室内热环境进行实测。根据测得的自然通风时段,分析了自然通风对房间风速及室内热环境的影响。主要结论有:(1)在自然通风条件下,房间白天室内风速均值及波动值较夜间大。(2)房间在自然通风时段,室内气温均值略低于室外,室内气温波动明显低于室外且各房间气温波动差别不大;房间在非自然通风时段,室内气温均值与室外气温相当,室温变化相当平缓。(3)无论是自然通风还是非自然通风,房间的黑球温度与室内空气温度差别很小。(4)当房间处于非自然通风状态时,室内热环境总是处于"不可接受"水平,当房间处于自然通风状态时,其室内热环境几乎全时段达到"可接受"水平,且有的房间在某些时段可达到"热舒适"水平。  相似文献   

16.
为研究上海地区人体热感觉和适应性热舒适现状,通过环境参数测量和问卷调查结合的方式来分析和探讨室内外气候条件、服装热阻、热感觉等关系。本文主要涉及自然通风建筑内人体热感觉和热中性温度随季节变化的关系。结果表明:在适应性热舒适研究中,人体中性温度与室外环境温度具有较强的相关性,得到的上海地区适应性热舒适模型可为适合我国自身特点的热舒适研究提供依据。  相似文献   

17.
The role of thermal mass is very important in natural ventilated buildings. Thermal mass can be classified as external thermal mass and internal thermal mass. In this paper, a heat balance model for naturally ventilated building is developed. The effect of external thermal mass is introduced by harmonic response method, and the effect of internal thermal mass is calculated by virtual sphere method which can lump different shapes and types into one virtual sphere. The effective convection heat transfer coefficient is presented to represents the effect of uneven distribution of internal thermal mass temperature. Through comparison with Li's model [1] and numerical calculation, it was found that the model is more suitable than the others, especially in estimating decrement factor of indoor air temperature. The errors of time lag become smaller when the fluctuation of indoor air temperature is smaller. Based on the model, a simple tool is developed to evaluate the indoor air temperature and required internal thermal mass for certain naturally ventilated buildings.  相似文献   

18.
The present paper aims to investigate the characteristics of airflow inside the room with insect proof screens by employing computation fluid dynamics (CFD) technique. Insect proof screens attached to the window openings were simulated by porous media approach. The simulated pressure drop across the insect proof screen was compared with the experimental result and is having a good agreement with a maximum error of 8.77% for the air velocity of 0.15 m/s. The insect proof screen significantly reduces the airflow rate and increases the indoor air temperature by 3°C. The effect of different window sizes and porosity of the insect proof screen is included for the study of thermal comfort index, predicted mean vote (PMV). From the PMV contours, center portion of the room and portions nearer to the windows are identified as comfort zones.  相似文献   

19.
Twelve public office buildings were selected for a study of relationships between worker's health symptoms and a number of building, workspace, job, and personal factors. Three buildings were naturally ventilated, three were mechanically ventilated, and six were air conditioned. Information on the prevalences of work-related symptoms, demographics, and job and personal factors were determined via a questionnaire completed by 880 occupants. Several indoor environmental parameters were measured. Logistic regression models were used to evaluate associations between symptom prevalences and features of the buildings, indoor environments, jobs, and personal factors. A substantial fraction of the occupants in these typical office buildings reported frequent work-related symptoms. The occupants of the mechanically ventilated and air conditioned buildings had sipifcantly more symptoms than occupants of the naturally ventilated buildings after adjustment for confounding factors. Increased prevalences of some symptoms were associated with several job and workspace factors including: presence of carpet, increased use of carbonless copy paper and photocopiers, space sharing, and distance from a window  相似文献   

20.
A major problem in the design of naturally ventilated buildings is the complicated interaction between the flow rates and the indoor air temperatures. The natural ventilation flow rates are influenced by the indoor air temperatures while the indoor air temperatures are in turn influenced by the flow rates. A good design tool should therefore consist of a flow model to determine the flow rates and a thermal to determine the indoor air temperatures. These two should be solved simultaneously in an integrated manner. Existing design tools lack the ability to address this.

This paper describes the implementation and verification of the new flow model derived in Part 1 of this paper into such an integrated natural ventilation design tool. The thermal model is based on existing theory that has been verified extensively. An iterative solution algorithm is employed to ensure simultaneous solution of these two models.

Continuous tracer gas and temperature measurements show that the integrated tool can be used with confidence in the design of naturally ventilated buildings. A case study is also presented that illustrates how the new tool can be used successfully to optimize the design of a naturally ventilated factory building.  相似文献   