共查询到20条相似文献,搜索用时 10 毫秒
1.
This work experimentally investigates the effects of the pyrolytic graphite sheets (PGS) on the performance and thermal management of a proton exchange membrane fuel cell (PEMFC) stack. These PGS with the features of light weight and high thermal conductivity serve as heat spreaders in the fuel cell stack for the first time to reduce the volume and weight of cooling systems, and homogenizes the temperature in the reaction areas. A PEMFC stack with an active area of 100 cm2 and 10 cells in series is constructed and used in this research. Five PGS of thickness 0.1 mm are cut into the shape of flow channels and bound to the central five cathode gas channel plates. Four thermocouples are embedded on the cathode gas channel plates to estimate the temperature variation in the stack. It is shown that the maximum power of the stack increase more than 15% with PGS attached. PGS improve the stack performance and alleviate the flooding problem at low cathode flow rates significantly. Results of this study demonstrate the feasibility of application of PGS to the thermal management of a small-to-medium-sized fuel cell stack. 相似文献
2.
This work experimentally investigates the thermal performance of a pyrolytic graphite sheet (PGS) in a single proton exchange membrane fuel cell (PEMFC). This PGS with high thermal conductivity serves as a heat spreader, reduces the volume and weight of cooling systems, and reduces and homogenizes the temperature in the reaction area of the fuel cells. A transparent PEMFC is constructed with PGS of thickness 0.1 mm cut into the shape of a flow channel and bound with the cathode gas channel plate. Eleven thermocouples are embedded at different positions on the cathode gas channel plate to measure the temperature distribution. The water and water flooding inside the cathode gas channels, with and without PGS, were successfully visualized. The locations of liquid water are correlated with the temperature measurement. PGS reduces the maximum cell temperature and improves cell performance at high cathode flow rates. The temperature distribution is also more uniform in the cell with PGS than in the one without PGS. Results of this study demonstrate the promising application of PGS to the thermal management of a fuel cell system. 相似文献
3.
《International Journal of Hydrogen Energy》2021,46(64):32665-32675
The thermal management of a proton exchange membrane fuel cell (PEMFC) is crucial for fuel cell vehicles. This paper presents a new simulation model for the water-cooled PEMFC stacks for automotive vehicles and cooling systems. The cooling system model considers both the cooling of the stack and cooling of the compressed air through the intercooler. Theoretical analysis was carried out to calculate the heat dissipation requirements for the cooling system. The case study results show that more than 99.0% of heat dissipation requirement is for thermal management of the PEMFC stack; more than 98.5% of cooling water will be distributed to the stack cooling loop. It is also demonstrated that controlling cooling water flow rate and stack inlet cooling water temperature could effectively satisfy thermal management constraints. These thermal management constraints are differences in stack inlet and outlet cooling water temperature, stack temperature, fan power consumption, and pump power consumption. 相似文献
4.
《International Journal of Hydrogen Energy》2023,48(28):10671-10683
Water flooding causes severe degradation of the performance and lifetime of proton exchange membrane fuel cell (PEMFC). In this study, a novel PEMFC stack with in-built moisture coil cooling was designed and the effects of moisture coil cooling on water management in the new PEMFC stack under various operating conditions were investigated. The result showed that the performance of the PEMFC stack was significantly improved due to the moisture condensation under high current density, high operating temperature, high relative humidity and high operating pressure. The output power was increases by 21.62% (525.71 W) at 1600·mA cm−2 while the increased parasitic power was no more than 35W. Moreover, degradation of the cathode catalyst layer after 100 h operation was also reduced by using moisture coil cooling. Compared with the situation without moisture condensation, the maximum decay rate of the cathode catalyst layer thickness after 100 h operation was reduced by 13.01%. Accordingly, the novel design is valuable and can be widely used in the future design of PEMFC. 相似文献
5.
《International Journal of Hydrogen Energy》2022,47(83):35398-35411
In this study, a kW-grade air-cooled proton exchange membrane fuel cell (PEMFC) stack with a dead-end anode (DEA) operation is designed and manufactured. The gravity-assisted drainage principle is applied for the stack to design the wettability of gas diffusion layers (GDLs) and the anode channel geometry, which can help the liquid water that diffuses to the anode to drain out of the anode porous electrode and move down the anode channel outlets. As a result, the stack can stably operate in a long purge interval of 268 s and in a short purge time of 2 s. In addition, using this design, only four small-power fans are employed to pump air to the cathode to provide oxygen for the electrochemical reaction and cool the stack. With a constant load current of 30, 45, or 60 A, the stack output voltage is experimentally tested at various cathode air flow rates (CAFRs). The local temperatures (60 measurement points) inside the stack and the pressure differences across anode channels are also monitored to understand heat dissipation and the back diffusion of liquid water. In a wide range of operating conditions, the designed stack possesses superior and stable voltage output characteristics with relatively uniform temperature distributions. The measured maximum output power is 3.83 kW, and the parasitic powers of fans are only 80~112 W. 相似文献
6.
《International Journal of Hydrogen Energy》2020,45(1):1030-1044
In the previous researches, researchers mainly focus on the single cell which is far away from the practical application. In this paper, shut-down process is studied in a 5-cell stack with segment technology. In the unprotected group, the hydrogen/air boundary is observed, and the output voltage performance degrades greatly after 300 start-stop cycles. A 2-phase auxiliary load strategy is proposed to avoid the hydrogen/air boundary. The lifetime is extended. But a serious local starvation is observed during the shut-down process. And corrosion happened in the inlet region. To avoid the starvation, the second strategy is designed, which combines 2-phase auxiliary and air purge (2-phase load& air purge strategy). With the new strategy, the degradation of the stack after 1500 cycles is acceptable, and the carbon corrosion in the inlet is effectively reduced. It could conclude that the hydrogen/air boundary is the main cause of the degradation of fuel cell during an unprotected shut-down process. And a strategy only with auxiliary load may suffer from the local starvation. The purge process can avoid the vacuum effect in the fuel cell caused by the auxiliary load. Therefore, adding an air purge during the shut-down process is promising in vehicle fuel cell. 相似文献
7.
《International Journal of Hydrogen Energy》2020,45(42):22324-22339
Air-breathing is known as a way to reduce the weight, volume, and the cost of PEMFCs. In this study, the thermal management of the high-powered air-breathing PEMFC stacks by applying different cathode flow channel configurations is carried out to improve the stack performance. In order to verify the thermal management results, numerical simulation is also performed. The research results show that a combination of the 50% and 58.3% opening ratios in the air-breathing stack reduces the stack temperature and enhances the temperature distribution uniformity, leading to a better and more stable stack performance. In addition, it is found that the stack performance is significantly improved under the assisted-air-breathing condition. Moreover, the simulation results and the experimental data are basically consistent. It is suggested to adopt the average temperature over the cross-sectional flow region from simulation as fitting the simulation results and the measured data. 相似文献
8.
A proton exchange membrane fuel cell (PEMFC) cogeneration system that provides high-quality electricity and hot water has been developed. A specially designed thermal management system together with a microcontroller embedded with appropriate control algorithm is integrated into a PEM fuel cell system. The thermal management system does not only control the fuel cell operation temperature but also recover the heat dissipated by FC stack. The dynamic behaviors of thermal and electrical characteristics are presented to verify the stability of the fuel cell cogeneration system. In addition, the reliability of the fuel cell cogeneration system is proved by one-day demonstration that deals with the daily power demand in a typical family. Finally, the effects of external loads on the efficiencies of the fuel cell cogeneration system are examined. Results reveal that the maximum system efficiency was as high as 81% when combining heat and power. 相似文献
9.
《International Journal of Hydrogen Energy》2023,48(50):19196-19206
As one of the most promising sustainable energy technologies available today, proton exchange membrane fuel cell (PEMFC) engines are becoming more and more popular in various applications, especially in transportation vehicles. However, the complexity and the severity of the vehicle operating conditions present challenges to control the temperature distribution in single cells and stack, which is an important factor influencing the performance and durability of PEMFC engines. It has been found that regulating the input and output coolant water temperature can improve the temperature distribution. Therefore, the control objective in this paper is regulating the input and output temperature of coolant water at the same time. Firstly, a coupled model of the thermal management system is established based on the physical structure of PEMFC engines. Then, in order to realize the simultaneous control of the inlet and outlet cooling water temperature of the PEMFC stack, a decoupling controller is proposed and its closed-loop stability is proved. Finally, based on the actual PEMFC engine platform, the effectiveness, accuracy and reliability of the proposed decoupling controller are tested. The experimental results show that with the proposed decoupling controller, the inlet and outlet temperatures of the PEMFC stack cooling water can be accurately controlled on-line. The temperature error range is less than 0.2 °C even under the dynamic current load conditions. 相似文献
10.
An experimental study on the transient power characteristics of a fuel cell generator has been conducted. The generator is hybridized by a proton exchange membrane (PEM) as the main power source and a lithium-ion battery as the secondary power source. power-conditioning module consisting of a main bidirectional converter and an auxiliary converter has been designed to manage the hybrid power of the generator that copes with fast dynamics of variable loads. Sensors embedded in the generator have measured the electrical properties dynamically. It was found that the present power-conditioning scheme has well controlled the power flow between the fuel cell stack and the battery by regulating the power flow from or to the battery. In addition, the thermal management system using pulse width modulation (PWM) schemes could limit the operation temperature of the fuel cell generator in a designed range. Furthermore, the dynamics of electrical efficiency of the generator are found to be parallel with those of the net system power. Finally, the stability and reliability of the fuel cell generator is proven by the rational dynamic behaviors of thermal and electrical properties for over 30-h demonstration. 相似文献
11.
Air-breathing proton exchange membrane (PEM) fuel cells provide for fully or partially passive operation and have gained much interest in the past decade, as part of the efforts to reduce the system complexity. This paper presents a detailed physics-based numerical analysis of the transport and electrochemical phenomena involved in the operation of a stack consisting of an array of vertically oriented air-breathing fuel cells. A comprehensive two-dimensional, nonisothermal, multi-component numerical model with pressurized hydrogen supply at the anode and natural convection air supply at the cathode is developed and validated with experimental data. Systematic parametric studies are performed to investigate the effects of cell dimensions, inter-cell spacing and the gap between the array and the substrate on the performance of the stack. Temperature and species distributions and flow patterns are presented to elucidate the coupled multiphysics phenomena. The analysis is used to determine optimum stack designs based on constraints on desired performance and overall stack size. 相似文献
12.
《International Journal of Hydrogen Energy》2021,46(62):31788-31797
Many places experience extreme temperatures below −30 °C, which is a great challenge for the fuel cell vehicle (FCV). The aim of this study is to optimize the strategy to achieve rapid cold start-up of the 30-cell stack at different temperature conditions. The test shows that the stack rapidly starts within 30 s at an ambient temperature of −20 °C. Turning on the coolant at −25 °C show stability of the cell voltage at both ends due to the end-plate heating, however, voltage of intermediate cells fluctuates sharply, and successful start-up is completed after 60 s. The cold start strategy changes to load-voltage cooperative control mode when the ambient temperature reduced to −30 °C, the voltage of multiple cells in the middle of the stack fluctuate more drastic, and start-up takes 113 s. The performance and consistency of the stack did not decay after 20 cold start-up experiments, which indicates that our control strategies effectively avoided irreversible damage to the stack caused by freeze-thaw process. 相似文献
13.
A preform moulding technique using expanded graphite is developed to manufacture composite bipolar plates for proton exchange membrane fuel cells (PEMFCs). The preform is composed of expanded graphite, graphite flake and phenol resin. Preforms utilizing the tangled structure of expanded graphite are easily fabricated at a low pressure of 0.07–0.28 MPa. A pre-curing temperature (100 °C) slightly above the melting point of phenol powders (90 °C) induces moderate curing, but also prevents excessive curing. After the preform is placed in a steel mould, compression moulding is carried out at high pressure (10 MPa) and temperature (150 °C). The fabrication conditions are optimized by checking the electrical conductivity, flexural strength and microstructure of the composite. The optimized electrical conductivity and flexural strength, 250 S cm−1 and 50 MPa, respectively, met the requirements for PEMFC bipolar plates. 相似文献
14.
Dong Liang Meiling Dou Ming Hou Qiang Shen Zhigang Shao Baolian Yi 《Journal of power sources》2011,196(13):5595-5598
Durability is an important issue in proton exchange membrane fuel cells (PEMFCs) currently. Fuel starvation could be one of the reasons for PEMFC degradation. In this research, the fuel starvation conditions of a unit cell in a stack are simulated experimentally. Cell voltage, current distribution and localized interfacial potentials are detected in situ to explore their behaviors under different hydrogen stoichiometries. Results show that the localized fuel starvation occurs in different sections at anode under different hydrogen stoichiometries when the given hydrogen is inadequate. This could be attributed to the “vacuum effect” that withdraws fuel from the manifold into anode. Behaviors of current distribution show that the current will redistribute and the position of the lowest current shifts close to the anode inlet with decreasing hydrogen stoichiometry, which indicates that the position of the localized fuel starvation would move towards the inlet of the cell. It is useful to understand the real position of the degradation of MEA. 相似文献
15.
《International Journal of Hydrogen Energy》2023,48(40):15215-15228
The temperature gradient inside an open-cathode air-cooled fuel cell is large because it uses air as its reaction and cooling media; moreover, the temperature of single cells near the endplates is low because of the high heat capacity of the endplate compared to single cells. Therefore, the cold start of open-cathode air-cooled fuel cells is difficult. In this work, the cold-start performance of an open-cathode air-cooled fuel cell stack, including the stack voltage, single-cell voltage and temperature distribution, are tested in a climatic chamber. The results show that the endplate effect has a significant adverse influence on the cold-start performance. Due to the existence of the endplate effect, the voltages of the single cells near the endplate decrease significantly. The stack can be successfully started at −5 °C without any external heating; however, when the temperature decreases below −10 °C, it cannot be started. At this time, if a certain power of endplate heating is adopted, successful cold-start can be achieved. However, if the temperature continues to decrease, the stack cannot be successfully started only through endplate heating because both the endplates and cold air affect the cold-start performance. Combining endplate and air heating may be a feasible cold-start method. 相似文献
16.
Solvent-assisted graphite loading for highly conductive phenolic resin bipolar plates for proton exchange membrane fuel cells 总被引:1,自引:0,他引:1
Soo-Jung Kang Jun-Ho Lee Min-Hye Lee Jun Young Lee Jong-Ho Lee Jae-Do Nam 《Journal of power sources》2010,195(12):3794-4242
A highly conductive polymer-based bipolar plate is fabricated using phenolic resin and graphite for proton exchange membrane fuel cells (PEMFCs). In order to load graphite fillers up to 90 wt% and minimize the void volume, the wetting properties of the graphite and phenolic resin are key factors for ensuring high electrical conductivity of the bipolar plates through good contact and uniform dispersion of graphite fillers. Since the surface free-energies of the phenolic resin and graphite are significantly different at 107.77 and 43.3 mJ m−2, respectively, to give a high contact angle of 87.1°, methanol with 19.6 mJ m−2 of surface energy is incorporated to decrease the contact angle between the matrix and graphite to 11.2°. By adjusting the surface energy of the matrix system, the conductivity of a composite containing 90 wt% of graphite reaches 379 S cm−1. The air permeability of the composite containing 80 wt% of graphite is less than 5 × 10−6 cm3 cm−2 s without open pores. The flexural modulus ranges from 6700 to 11000 MPa for graphite loads between 60 and 80 wt%, respectively. 相似文献
17.
Pablo Martins Belchor Maria Madalena Camargo Forte Deyse Elisabeth Ortiz Suman Carpenter 《International Journal of Hydrogen Energy》2012
In a proton exchange membrane fuel cell (PEMFC) water management is one of the critical issues to be addressed. Although the membrane requires humidification for high proton conductivity, water in excess decreases the cell performance by flooding. In this paper an improved strategy for water management in a fuel cell operating with low water content is proposed using a parallel serpentine-baffle flow field plate (PSBFFP) design compared to the parallel serpentine flow field plate (PSFFP). The water management in a fuel cell is closely connected to the temperature control in the fuel cell and gases humidifier. The PSBFFP and the PSFFP were evaluated comparatively under three different humidity conditions and their influence on the PEMFC prototype performance was monitored by determining the current density–voltage and current density–power curves. Under low humidification conditions the PEMFC prototype presented better performance when fitted with the PSBFFP since it retains water in the flow field channels. 相似文献
18.
Calvin D'Souza Michael Apicella Ahmad El-kharouf Emmanuel Stamatakis Martin Khzouz Athanasios Stubos Evangelos I. Gkanas 《国际能源研究杂志》2020,44(14):11597-11613
In light of stricter emissions regulations and depleting fossil fuel reserves, fuel cell vehicles (FCVs) are one of the leading alternatives for powering future vehicles. An open-cathode, air-cooled proton exchange membrane fuel cell (PEMFC) stack provides a relatively simple electric generation system for a vehicle in terms of system complexity and number of components. The temperature within a PEMFC stack is critical to its level of performance and the electrochemical efficiency. Previously created computational models to study and predict the stack temperature have been limited in their scale and the inaccurate assumption that temperature is uniform throughout. The present work details the creation of a numerical model to study the temperature distribution of an 80-cell Ballard 1020ACS stack by simulating the cooling airflow across the stack. Using computational fluid dynamics, a steady-state airflow simulation was performed using experimental data to form boundary conditions where possible. Additionally, a parametric study was performed to investigate the effect of the distance between the stack and cooling fan on stack performance. Model validation was performed against published results. The temperature distribution across the stack was identical for the central 70% of the cells, with eccentric temperatures observed at the stack extremities, while the difference between coolant and bipolar plate temperatures was approximately 10°C at the cooling channel outlets. The results of the parametric study showed that the fan-stack distance has a negligible effect on stack performance. The assumptions regarding stack temperature uniformity and measurement were challenged. Lastly, the hypothesis regarding the negligible effect of fan-stack distance on stack performance was confirmed. 相似文献
19.
《International Journal of Hydrogen Energy》2022,47(3):1888-1900
The proton exchange membrane fuel cell (PEMFC) stack is a key component in the fuel cell/battery hybrid vehicle. Thermal management and optimized control of the PEMFC under real driving cycle remains a challenging issue. This paper presents a new hybrid vehicle model, including simulations of diver behavior, vehicle dynamic, vehicle control unit, energy control unit, PEMFC stack, cooling system, battery, DC/DC converter, and motor. The stack model had been validated against experimental results. The aim is to model and analyze the characteristics of the 30 kW PEMFC stack regulated by its cooling system under actual driving conditions. Under actual driving cycles (0–65 kW/h), 33%–50% of the total energy becomes stack heat; the heat dissipation requirements of the PEMFC stack are high and increase at high speed and acceleration. A PID control is proposed; the cooling water flow rate is adjusted; the control succeeded in stabilizing the stack temperature at 350 K at actual driving conditions. Constant and relative lower inlet cooling water temperature (340 K) improves the regulation ability of the PID control. The hybrid vehicle model can provide a theoretical basis for the thermal management of the PEMFC stack in complex vehicle driving conditions. 相似文献
20.
This paper applies multivariable robust control strategies to a proton exchange membrane fuel cell (PEMFC) system. From the system point of view, a PEMFC can be modeled as a two-input-two-output system, where the inputs are air and hydrogen flow rates and the outputs are cell voltage and current. By fixing the output resistance, we aimed to control the cell voltage output by regulating the air and hydrogen flow rates. Due to the nonlinear characteristics of this system, multivariable robust controllers were designed to provide robust performance and to reduce the hydrogen consumption of this system. The study was carried out in three parts. Firstly, the PEMFC system was modeled as multivariable transfer function matrices using identification techniques, with the un-modeled dynamics treated as system uncertainties and disturbances. Secondly, robust control algorithms were utilized to design multivariable H∞ controllers to deal with system uncertainty and performance requirements. Finally, the designed robust controllers were implemented to control the air and hydrogen flow rates. From the experimental results, multivariable robust control is shown to provide steady output responses and significantly reduce hydrogen consumption. 相似文献