首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
Resistance heating with PTC elements to cover the heat demand of electric vehicles reduces significantly the cruising range at low outside temperatures. Reversible heat pump systems are one of the most promising solutions for this problem. However, in heat pump mode the frost formation on the exterior heat exchanger reduces the performance and efficiency of the system. Therefore, an efficient defrost method is crucial to benefit from the heat pump also under frosting conditions. In the present paper, a transient Modelica simulation model of a reversible CO2-heat pump system with hot gas defrost was set up in order to assess the impact of different defrost start times. The model is able to handle frost growth on the exterior heat exchanger as well as defrosting. The simulation results showed an optimal point of time to conduct defrost at chosen operating conditions in order to maximize the average COP including the frosting and defrost period.  相似文献   

2.
Use of a two-phase flow ejector as an expansion device in vapor compression refrigeration systems is one of the efficient ways to enhance its performance. The present work aims to design a constant-area two phase flow ejector and to evaluate performance characteristics of the ejector expansion refrigeration system working with R134a. In order to achieve these objectives, a simulation program is developed and effects of operating conditions and ejector internal efficiencies on the system performance are investigated using EES software. Comparison between present results and published experimental data revealed that the developed model can predict the system COP with a maximum error of 2.3%. The system COP increased by 87.5% as evaporation temperature changed from −10 °C to 10 °C. Finally, correlations to size ejector main diameters as a function of operating conditions, system cooling capacity and ejector internal efficiencies are reported.  相似文献   

3.
The gas-engine driven air-to-water heat pump, type air conditioning system, is composed of two major thermodynamic cycles (including the vapor compression refrigeration cycle and the internal combustion gas engine cycle) as well as a refrigerant-water plate heat exchanger. The thermal modeling of gas engine driven air-to-water heat pump system with engine heat recovery heat exchangers was performed here for the heating mode of operation (in which it was required to model engine heat recovery heat exchanger). The modeling was performed using typical thermodynamic characteristics of system components, Artificial Neural Network and the multi-objective genetic algorithm optimization method. The comparison of modeling results with experimental ones showed average differences of 5.08%, 5.93%, 5.21%, 2.88% and 6.2% which shows acceptable agreement for operating pressure, gas engine fuel consumption, outlet water temperature, engine rotational speed, and system primary energy ratio.  相似文献   

4.
A novel parallel-type hybrid-power gas engine-driven heat pump system   总被引:1,自引:0,他引:1  
This paper presents a novel concept to integrate a heat pump system and a power system which form a hybrid-power gas engine-driven heat pump (HPGHP) system. The power system of the HPGHP system includes an engine, a motor, a set of battery packs, a continuous variable transmission device and a power-control module. The engine in the power system is capable of operating constantly with high thermal efficiency and low emissions during the four different operating modes: for operating mode A, the ICE powers directly to match the compressor's demand load by throttling the natural-gas flow or adjusting the speed of the ICE, correspondingly the battery packs are disengaged and the ICE operates alone; for operating mode B, the ICE operates in the unique condition with the lowest fuel consumption ratio, meanwhile, the battery packs discharge to provide the supplementary power by the power-control module; for operating mode C, the ICE operates in the unique condition with the lowest fuel consumption ratio, and the redundant power provided by the ICE is converted by the motor to charge the battery packs, here, the motor is used as a generator; for operating mode D, the ICE is disengaged and the battery pack is used alone. Simulation results of the power system showed that for a conventional gas engine-driven heat pump (GHP) system the maximum and minimum thermal efficiencies of the power system are 33% and 22%, respectively; compared with the conventional GHP system, the power system in the novel HPGHP system has superior performance with the maximum and minimum thermal efficiencies of 37% and 27%, respectively.  相似文献   

5.
CCHP (combined cooling heating and power) system based on ICE (internal combustion engine) has been widely used. A key issue is to efficiently recover the jacket water and exhaust gas waste heat for refrigeration. In this work, a mixed effect absorption chiller (AC), which couples single effect and double effect processes together, is investigated to recover these two kinds of waste heat simultaneously. The high pressure generator is powered by exhaust gas while one low pressure generator is powered by jacket water waste heat. Thermodynamic characteristics and off-design performance are simulated. Considering thermodynamic constraints, the start point temperature in low pressure generator should be 77°Cor lower. For a 16 kW ICE, the cooling output can reach 34.4 kW with COP of 0.96 and exergy efficiency of 0.186. Comparing with double effect or single effect AC, it can make a better use of different waste heat in CCHP system.  相似文献   

6.
This paper proposes a thermoelectric-assisted vapor compression cycle (TVCC) for applications in air-source heat pump systems which could enhance the heating capacity of the system. Performances of TVCC are calculated and then compared with that of basic vapor compression cycle (BVCC). The simulation results show that when coefficients of performance (COPs) of the two cycles are almost equal, the TVCC under maximum COP condition of the thermoelectric modules still performs better than BVCC by 13.0% in heating capacity through selecting the appropriate intermediate temperature. In addition, the TVCC can also achieve an improvement of 16.4%–21.7% in both the heating COP and capacity when compared with the BVCC with an assistant electric heater that is provided with the equivalent power input of thermoelectric heat exchanger. Thus, the TVCC could be beneficial to the applications in small heat pumps if there is always need for auxiliary electric heat.  相似文献   

7.
In this paper, an ejector enhanced vapor injection CO2 transcritical heat pump cycle with sub-cooler (ESCVI) for heating application in cold regions is proposed. The thermodynamic analysis using energetic and exegetic methods is carried out to predict the performance characteristics of the ejector enhanced cycle, and then compared with those of the conventional vapor injection heat pump cycle with sub-cooler (SCVI). The simulation results demonstrate that the ejector enhanced cycle exhibits better performance than the conventional vapor injection cycle under the specified operating conditions. The improvements of the maximum system COP and volumetric heating capacity could reach up to 7.7% and 9.5%, respectively. Exergetic analysis indicates that the largest exergy destruction ratio is generated at the compressor followed by the evaporator and gas cooler. Additionally, the exergy efficiency of the ejector is introduced to quantify the effectiveness of the exergy recovery process, which may be a new criterion to evaluate the performance of the ejector enhanced vapor compression cycle.  相似文献   

8.
A microwave assisted zeolite–water adsorption heat pump system was designed, manufactured and investigated experimentally. The influence of operation time of microwave oven on performance of the adsorption heat pump was studied. The performance criteria: coefficient of performance, specific cooling power and volumetric cooing power, were calculated for the designed and tested adsorption heat pump system. The regeneration of adsorbent bed was achieved very rapidly (35 min) by using microwave heating system. The poor thermal conductivity of adsorbent did not affect the periods of isosteric heating and isobaric desorption processes.  相似文献   

9.
Air (reversed Brayton) cycle has been utilized in the area of refrigeration and cryogenics for several decades, but its potentials in heat pump applications were longtime underestimated. In this paper, a thermodynamic model for the regenerated air heat pump cycle with practical compressor, expander and regenerated heat exchanger was developed. Based on the model, the relations between the system performance and the operating parameters were analyzed. The optimal heating COP (coefficient of performance) and the corresponding pressure ratio were derived. Then, air heat pump cycles (regenerated cycle and basic cycle) and vapor-compression heat pump cycles (CO2 trans-critical cycle and R410A subcritical cycle) were numerically compared. The results indicated that the regenerated air heat pump cycle not only gets the heating capacity in line with the heating load under different operating conditions but also achieves higher COP over trans-critical CO2 heat pump cycle in applications of large temperature difference.  相似文献   

10.
The objective of this study is to investigate the effects of vapor injection techniques on the heating performance of a CO2 heat pump. The performances of the flash tank vapor injection (FTVI), sub-cooler vapor injection (SCVI) and FTVI with a suction line heat exchanger (FTSX) cycles were measured and analyzed with variations of the outdoor temperature, compressor frequency, and injection mass flow rate. At the outdoor temperature of −15 °C and compressor frequency of 55 Hz, the heating capacity and COP of the optimized SCVI cycle were 12.1% and 12.7% higher than those of the optimized FTVI cycle, respectively, because the total mass flow rate in the SCVI cycle was higher than that in the FTVI cycle by the large temperature and pressure differences in the sub-cooler of the SCVI cycle. In addition, the optimum injection flow rate ratios in the vapor injection CO2 cycles yielding the maximum COP were determined at various compressor frequencies.  相似文献   

11.
Evaporative condenser is an energy efficient and environmentally friendly air conditioning equipment. This paper proposed an air conditioning system using dual independent evaporative condenser and investigated the cooling performance. Many factors, such as evaporator water inlet temperature, compressor frequency, air dry-bulb temperature, air velocity and water spray rate, which influenced the cooling performances of air conditioning system with evaporative condenser have been investigated. The results indicated that cooling capacity and coefficient of performance (COP) increased significantly with the increasing of evaporator water inlet temperature (12–25 °C), the air velocity (2.05–3.97 m s−1) and the water spray rate (0.03–0.05 kg m−1 s). However, COP decreased with the increasing ambient air dry-bulb temperature (31.2–35.1 °C) and the compressor frequency (50–90 Hz). Furthermore, the heat transfer coefficient (K0) was 232–409 W m−2 K−1 in different air velocity and water spray rate.  相似文献   

12.
This paper presents an innovative reversible Heat Pump/Organic Rankine Cycle (HP/ORC) experimental unit designed to be coupled to a Net Zero Energy Building (connected to a 120 m2 thermal solar roof and a ground heat exchanger). The system can operate in three different modes: an ORC mode to produce electricity when a large amount of heat is collected by the solar roof, a direct heating mode using exclusively the solar roof, and a HP mode for space heating during cold weather conditions. This paper describes a comprehensive experimental campaign carried out on a prototype unit using a modified HVAC scroll compressor (4 kWe). From the results, the technical feasibility of the system is demonstrated. A cycle efficiency of 4.2% is achieved in ORC mode (with condensation and evaporation temperature respectively of 25 °C and 88 °C) and a COP of 3.1 is obtained in HP mode (with condensation and evaporation temperature respectively of 61 °C and 21 °C).  相似文献   

13.
Reducing energy consumption by utilizing heat recovery systems has become increasingly important in industry. This paper presents an exploratory assessment of heat pump type heat recovery systems using environmentally friendly refrigerants. The coefficient of performance (COP) of 4 cycle configurations used to raise the temperature of heat media to 160 °C with a waste heat at 80 °C is calculated and compared for refrigerants R717, R365mfc, R1234ze(E), and R1234ze(Z). A multiple-stage “extraction” cycle drastically reduces the throttling loss and exergy loss in the condensers, resulting in the highest COP for R1234ze(Z). A cascade cycle using R1234ze(Z) and R365mfc has a relatively high COP and provides practical benefits. Even under adverse conditions, the primary energy efficiency is greater than 1.3 when the transmission end efficiency of the electric power generation is 0.37. The assessment demonstrated that high-temperature heat pumps are a promising approach for reducing primary energy consumption for industrial applications.  相似文献   

14.
Frost retardation of an air-source heat pump by the hot gas bypass method   总被引:3,自引:1,他引:2  
This study is concerned with a hot gas (refrigerant) bypass method to retard the formation and propagation of frost in an air-source heat pump. The feasibility of the hot gas bypass method was investigated experimentally and the method's performance is compared with that of a normal, 1.12 kW capacity air-source heat pump system with no defrost equipment such as an electric resistance heater. Results indicate that the hot gas bypass method is useful for retarding the formation and growth of frost at the outdoor coil. The best performance is shown under a bypass refrigerant flow rate of 0.2 kg/min (20% of the whole system refrigerant flow rate). During 210 min of heat pump operation, the hot gas bypass method improved COP and heating capacity at an average of 8.5% and 5.7%, respectively, relative to the normal system.  相似文献   

15.
This paper studies the influence of working fluids over the performance of heat driven ejector refrigeration systems performance by using a lumped parameter model. The model used has been selected after a comparison of different models with a set of experimental data available in the literature. The effect of generator, evaporator and condenser temperature over the entrainment ratio and the COP has been investigated for different working fluids in the typical operating conditions of low grade energy sources. The results show a growth in performance (the entrainment ratio and the COP) with a rise in the generator and evaporator temperature and a decrease in the condenser temperature. The working fluids have a great impact on the ejector performance and each refrigerant has its own range of operating conditions. R134a is found to be suitable for low generator temperature (70–100 °C), whereas the hydrocarbons R600 is suitable for medium generator temperatures (100–130 °C) and R601 for high generator temperatures (130–180 °C).  相似文献   

16.
The prototype of an air-cooled double-lift NH3–H2O absorption chiller driven by hot water at low temperature is presented. The main objective of the study is to illustrate the experimental performances of the prototype under different operating conditions. A mathematical model of the cycle is developed, along with a procedure for the identification of otherwise difficult to measure data, with the purpose of providing the complete picture of the internal thermodynamic cycle. The combined experimental and numerical data allowed assessing the effects on the thermodynamic cycle with varying operating conditions. The unit operated steadily with chilled water inlet 12 °C, outlet 7 °C, air temperature between 22 °C and 38 °C, and hot water driving temperatures between 80 °C and 90 °C. The reference cooling capacity at air temperature of 30 °C is 2.5 kW, with thermal COP about 0.3 and electrical COP about 10.  相似文献   

17.
A model of a novel rotary spool compressor has been developed to explore the effect of multiple injection ports on compressor and cycle performance. The thermodynamic model includes the effects of heat transfer and leakage and is numerically solved to predict the compressor power consumption and mass flow rate. Saturated vapor injection is modeled assuming that the injection pressures and the timing of the injection process can be controlled.The model predicts that adding a single injection port will provide a 12% increase in the cycle coefficient of performance (COP) when the compressor runs at 1907 rpm with R-22 evaporating at ?7 °C, condensing at 49 °C, and 15 °C of superheat. Adding a second, non-optimized injection port increases the COP by 16% compared to the cycle without injection. The model is used to investigate the effect of injection pressure, port location, and port diameter on cycle performance.  相似文献   

18.
To avoid global warming potential gases emission from vapor compression air-conditioners and water chillers, alternative cooling technologies have recently garnered more and more attentions. Thermoelastic cooling is among one of the alternative candidates, and have demonstrated promising performance improvement potential on the material level. However, a thermoelastic cooling system integrated with heat transfer fluid loops have not been studied yet. This paper intends to bridge such a gap by introducing the single-stage cycle design options at the beginning. An analytical coefficient of performance (COP) equation was then derived for one of the options using reverse Brayton cycle design. The equation provides physical insights on how the system performance behaves under different conditions. The performance of the same thermoelastic cooling cycle using NiTi alloy was then evaluated based on a dynamic model developed in this study. It was found that the system COP was 1.7 for a baseline case considering both driving motor and parasitic pump power consumptions, while COP ranged from 5.2 to 7.7 when estimated with future improvements.  相似文献   

19.
Thermoelastic cooling is a recently proposed, novel solid-state cooling technology. It has the benefit of not using high global warming potential (GWP) refrigerants which are used in vapor compression cycles (VCCs). Performance enhancements on a thermoelastic cooling prototype were investigated. A few novel design options aiming to reduce the cyclic loss were proposed. It was found that the maximum temperature lift increased from 6.6 K to 27.8 K when applying the proposed novel designs, corresponding to 0–152 W cooling capacity enhancement evaluated under 10 K water–water system temperature lift. In addition, a multi-objective optimization problem was formulated and solved using the genetic algorithm to maximize the system capacity and coefficient of performance (COP). With all the novel designs, the optimization could further enhance 31% COP, or 21% cooling capacity, corresponding to COP of 4.1 or 184 W maximum cooling capacity.  相似文献   

20.
Blends of CO2 with ten low-global warming potential (GWP) working fluids are evaluated for use in a heat pump water heater. The effects that the discharge pressure, component ratio, hot-water outlet temperature and chilled water inlet temperature have on the coefficient of performance (COP) of heat pump are analyzed when the pinch point of the heat exchange is considered. It is found that temperature glide of zeotropic mixture has a good thermal match with the temperature change of water as two pinch points appear in the gas cooler/condenser or evaporator. The good thermal match in the heat exchangers promotes the system COP. Addition of low-GWP working fluids to pure CO2 can reduce the high-side pressure. The results show that CO2/R41 and CO2/R32 are suitable candidates for heat pump water heaters because of their high COP and low high-side pressure in comparison with those of a pure CO2 cycle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏