首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The concentration measurement of pulverized coal in a pneumatic pipeline is a challenging issue in power plant. A thermal probe manufactured with abrasion-proof steel was developed for coal concentration measurement in such a situation. The probe generates 15 W of heat. This method is based on the heat transfer between the thermal probe and the gas–solid two-phase flow. Experiments were conducted in a horizontal pneumatic pipeline to assess the accuracy of the thermal probe, where the gas was air and the solid was pulverized coal with mean diameter of 65 µm. The wall temperature of the thermal probe was found to be dependent on both coal powder concentration and air velocity. A new heat transfer correlation was proposed in terms of the modified Reynolds and Nusselt numbers for the gas–solid two-phase flow across the thermal probe. In the range of coal powder concentration from 0.1 to 0.65 kg/kg, the standard deviation is 0.01 kg/kg for the thermal probe. The thermal probe has potential application for concentration measurement of pulverized coal in the pneumatic pipelines of power plants.  相似文献   

2.
It is necessary to monitor and balance the pulverized coal velocity and flowrate among the conveying pipelines leading to injection burners and to optimize the air-coal ratio for safety, economical operation, and reduction of pollution of coal-fired boilers in power plants. A novel electrostatic sensing system is reported for monitoring the velocity and relative mass flowrate of pulverized coal. The design, implementation, and on-plant trials of the system are reported. The velocity of pulverized coal was determined by autocorrelating the output derived from a linear electrostatic sensor array. The relative concentration and mass flowrate were obtained by the root mean square values of the output of two ring-shaped electrodes with the consideration of the pulverized coal velocity. The instrumentation was evaluated on a full-scale 600 MW power generation unit. The results demonstrate that the technique provides reliable measurement of pulverized coal velocity, relative flowrate, and split distribution among the injection pipes from the same pulverizing mill. The prototype achieved split balance and optimized air/coal ratio in combination with the pulverized coal balancing control valve and proportional-integral-derivative controller in fuel injection pipes in a power plant.  相似文献   

3.
Prism signal processing is a new recursive FIR technique that facilitates the rapid tracking of sinusoidal signals, such as those used in a Coriolis Mass Flow Meter (CMFM). A Prism-based CMFM prototype has been developed using a commercial flowtube and a dual ARM processor-based transmitter, which is capable of generating flow measurement updates at 48 kHz. This has been applied in a feasibility study to the tracking of fast (e.g. 1.5 ms) injections of diesel fuel on a laboratory rig at engine speeds of up to 4000 rpm equivalent and at fuel pressures of up to 100 MPa. Due to the high level of vibration in the system, Prism-based notch filtering is used to suppress undesired modes of flowtube vibration in the sensor signal. Individual flow pulses can be detected by the system, but the relatively long period of oscillation of the flowtube compared to the fuel injection duration results in a spreading out over time of each flow pulse measurement. More precise measurement results may be obtained using a higher frequency resonant flowtube.  相似文献   

4.
Wire-mesh sensors (WMS), developed at HZDR [4], [13], are widely used to visualize two-phase flows and measure flow parameters, such as phase fraction distributions or gas phase velocities quantitatively and with a very high temporal resolution. They have been extensively applied to a wide range of two-phase gas–liquid flow problems with conducting and non-conducting liquids. However, for very low liquid loadings, the state of the art data analysis algorithms for WMS data suffer from the comparably low spatial resolution of measurements and from boundary effects, caused by e.g. flange rings – especially in the case of capacitance type WMS. In the recent past, diverse studies have been performed on two-phase liquid–gas stratified flow with low liquid loading conditions in horizontal pipes at the University of Tulsa. These tests cover oil–air flow in a 6-inch ID pipe and water–air flow in a 3-inch ID pipe employing dual WMS with 32×32 and 16×16 wires, respectively. For oil–air flow experiments, the superficial liquid and gas velocities vary between 9.2 m/s≤νSG≤15 m/s and 0.01 m/s≤νSL≤0.02 m/s, respectively [2]. In water–air experiments, the superficial liquid and gas velocities vary between 9.1 m/s≤νSG≤33.5 m/s and 0.03 m/s≤νSL≤0.2 m/s, respectively [17], [18]. In order to understand the stratified wavy structure of the flow, the reconstruction of the liquid–gas interface is essential. Due to the relatively low spatial resolution in the WMS measurements of approximately 5 mm, the liquid–gas interface recognition has always an unknown uncertainty level. In this work, a novel algorithm for refined liquid–gas interface reconstruction is introduced for flow conditions where entrainment is negligible.  相似文献   

5.
Industrial applications involving pulsed ultrasound instrumentation require complete non-invasive setups due to high temperatures, pressures and possible abrasive fluids. Recently, new pulser-receiver electronics and a new sensor unit were developed by Flow-Viz. The complete sensor unit setup enables non-invasive Doppler measurements through high grade stainless steel. In this work a non-invasive sensor unit developed for one inch pipes (22.5 mm ID) and two inch pipes (48.4 mm ID) were evaluated. Performance tests were conducted using a Doppler string phantom setup and the Doppler velocity results were compared to the moving string target velocities. Eight different positions along the pipe internal diameter (22.5 mm) were investigated and at each position six speeds (0.1–0.6 m/s) were tested. Error differences ranged from 0.18 to 7.8% for the tested velocity range. The average accuracy of Doppler measurements for the 22.5 mm sensor unit decreased slightly from 1.3 to 2.3% across the ultrasound beam axis. Eleven positions were tested along the diameter of the 48.4 mm pipe (eight positions covered the pipe radius) and five speeds were tested (0.2–0.6 m/s). The average accuracy of Doppler measurements for the 48.4 mm sensor unit was between 2.4 and 5.9%, with the lowest accuracy at the point furthest away from the sensor unit. Error differences varied between 0.07 and 11.85% for the tested velocity range, where mostly overestimated velocities were recorded. This systematic error explains the higher average error difference percentage when comparing the 48.4 mm (2.4–5.9%) and 22.5 mm (1.3–2.3%) sensor unit performance. The overall performance of the combined Flow-Viz system (electronics, software, sensor) was excellent as similar or higher errors were typically reported in the medical field. This study has for the first time validated non-invasive Doppler measurements through high grade stainless steel pipes by using an advanced string phantom setup.  相似文献   

6.
The fiber Bragg grating geophone sensor with higher sensitivity and wider frequency range was reported. The methods to increase the sensitivity of the FBG cantilever sensor were presented. The acceleration sensitivity of the optimized FBG geophone is 220 pm/g, and the resonant frequency can reach to 295 Hz. The experiments show that the FBG geophone system has the minimum detectable acceleration of 1 mm/s2. Some factual application examples of using this fiber Bragg grating geophone monitoring system for micro seismic monitoring in coal mine were presented.  相似文献   

7.
This paper presents a runout measurement method and a novel finite grouping method to predict and optimize the rotational angle and translational displacement of butting pipes to minimize pipe wall misalignment (PWM). This study develops a method to minimize the PWM of the pipes excluding the positions of welding seams. In this method, the measurement data are divided into finite groups and the criteria are created to identify the positions of welding seams and eliminate the effect of the welding seams. Finally, the rotational angle and translational displacement of the butting pipes are optimized to minimize the PWM. A butting machine is designed to implement this method. The machine is benchmarked by a standard smooth pipe to minimize system errors. Three butting experiments have been performed with welded pipes of diameter 406 mm. The comparison shows that the computation results agree with the experimental results very well. The maximum PWMs in three experiments are less than 1.87 mm, which satisfies the butting requirements, that is, a PWM of less than 2.0 mm. Then, the uncertainties of the measurement results are discussed.  相似文献   

8.
Within the framework of a research project regarding investigations on a high-pressure Coriolis mass flow meter (CMF) a portable flow test rig for traceable calibration measurements of the flow rate (mass - and volume flow) in a range of 5 g min−1 to 500 g min−1 and in a pressure range of 0.1 MPa to 85 MPa was developed. The measurement principle of the flow test rig is based on the gravimetrical measuring procedure with flying-start-and-stop operating mode. Particular attention has been paid to the challenges of temperature stability during the measurements since the temperature has a direct influence on the viscosity and flow rate of the test medium. For that reason the pipes on the high-pressure side are double-walled and insulated and the device under test (DUT) has an enclosure with a separate temperature control. From the analysis of the first measurement with tap water at a temperature of 20 °C and a pressure of 82.7 MPa an extensive uncertainty analysis has been carried out. It was found that the diverter (mainly due to its asymmetric behaviour) is the largest influence factor on the total uncertainty budget. After a number of improvements, especially concerning the diverter, the flow test rig has currently an expanded measurement uncertainty of around 1.0% in the lower flow rate range (25 g min−1) and 0.25% in the higher flow rate range (400 g min−1) for the measurement of mass flow. Additional calibration measurements with the new, redesigned flow test rig and highly viscous base oils also indicated a good agreement with the theoretical behaviour of the flow meter according to the manufacturers׳ specifications with water as test medium. Further improvements are envisaged in the future in order to focus also on other areas of interest.  相似文献   

9.
Impedance plethysmography, also known as the impedance test, the blood flow test, or impedance phlebography, is a non-invasive test that measures blood flow in the vessels of the peripheral vascular system by monitoring changes in electrical resistance (impedance) to detect deep thrombosis (blood clots or thrombophlebitis).The aim of our study was to use this technique for assessing changes in blood flow in the lower limbs in healthy subjects wearing protective footwear while walking.The test was performed on a group of 30 professional firefighters (age 30.7 ± 4.5, BMI 25.1 ± 3). Blood flow was monitored in the peripheral vascular system of the lower limbs during walking on a treadmill. The testing protocol consisted of the following three phases: warm-up, exercise, and rest.In order to identify differences between the three phases of the study, analysis of variance (ANOVA) with repeated measures was conducted. The statistically significant parameters of blood flow in the lower limbs were the impedance ratio (IR) (p < 0.001), slope ratio (SR) (p < 0.001), crest width (CW) (p < 0.001), and alternative blood flow (ABF) (p < 0.001). All of them showed an upward trend.The study confirmed the validity of impedance plethysmography as a non-invasive technique for measuring blood flow changes in the lower limbs in healthy subjects, especially under non-steady-state conditions, such as walking. This technique provides valuable quantitative data.Therefore, impedance plethysmography may be considered a reliable research method enabling evaluation of local blood flow in healthy subjects under different conditions.  相似文献   

10.
In the hardware-in-loop simulation of aero-engine control system where the real fuel regulator is engaged, it's crucial to measure the real-time flow rate. In view of this, a flow meter with high precision and fast response is important. In this paper, modeling and experiments are conducted to verify the dynamic characteristics of a turbine flow meter (TFM). For the modeling part, driving torque and resistance torques are analyzed to derive the kinetic equation of TFM. Simulation with the kinetic equation shows good dynamic performance of TFM. In experiments, a workbench is designed to generate step-type flow and sine-type flow for identification in time domain and frequency domain. Results show that the settling time for TFM is no more than 100 ms and its band-with is over 4.61 Hz. Compared with the settling time of a main fuel valve and the band-width of a main fuel control loop, that is, 1.2 s and 2 Hz respectively, TFM is considered to be adaptive to measure the fuel of aero-engine.  相似文献   

11.
We describe a flow standard for gas flows in the range from 0.01 sccm to 100 sccm with a relative standard uncertainty (68% confidence) of 0.03% at 1 sccm (1 sccm≡1 cm3/min of an ideal gas at 101325 Pa and 0 °C ≈ 0.74358 μmol/s). The flow standard calibrates a secondary meter by withdrawing a piston from a cylinder held at constant pressure P while gas flows from the secondary meter into the cylinder. The flow standard can operate anywhere in the range 10 kPa<P<300 kPa, and it can act as a flow source as well as a flow receiver. The flow standard incorporated features that improved its convenience and lowered its cost without sacrificing accuracy, specifically (1) dry sliding seals made with commercially available, easily replaced, o-rings, (2) a compact design based on a commercially available, hollow piston, and (3) a linear encoder with a small Abbe error.  相似文献   

12.
Sodium cooled Fast Reactors (SFR) require measurement of liquid sodium flow in its primary and secondary circuits. For the primary system of the pool type concept of SFR design, flowmeters have to be immersed in sodium pool and require flow sensors which can withstand high temperatures up to 550 °C, nuclear radiation and chemically reactive sodium environment. Secondary circuits and safety grade decay heat removal (SGDHR) circuits of SFR need flow measurement in stainless steel (SS) pipes of diameter varying from 15 mm to 800 mm. For small pipes, flowmeters with permanent magnet flowmeter with ALNICO-V magnet assembly is the unanimous choice. Conventional permanent magnet flowmeters (PMFM) for large pipelines become bulky, heavy and have installation problems. For sodium flow measurement in large pipelines a few other alternate methods are considered. In the case of Prototype Fast Breeder Reactor (PFBR), which is at an advanced stage of construction at Kalpakkam, flow in the 800 mm diameter secondary main circuit is measured by means of a bypass flowmeter. Other sensors that could be deployed include eddy current flowmeters (ECFM), which are introduced into the pipe to measure flow velocity in the pipe, ultrasonic flowmeters and permanent magnet based side wall flowmeters. In permanent magnet based side wall flowmeter (SWFM), a permanent magnet block is mounted on one side of the large pipe and the magnetic field produced by the magnet penetrates through the pipe and interacts with the flowing sodium and induces an electro motive force (emf) proportional to the flow. This is a compact, cost effective and fairly accurate method for flow measurement in large pipelines of SFR circuits. SWFM is suitable for pipelines of 100 mm and above. In the present work a side wall flowmeter for 100 mm pipe is designed, manufactured, calibrated and tested in an existing sodium facility. Voltage signal developed in SWFM for different flowrates was simulated with three dimensional Finite Element Model (FEM) and validated with experimental results. Effect of asymmetric magnetic field on flowmeter voltage signal and dependence of flowmeter voltage signal on position of electrodes was also analyzed with model. The feasibility of use of this type of flowmeter for large pipelines of SFRs is demonstrated.  相似文献   

13.
14.
This research investigates the effects of flow pattern and salinity of oil-water two-phase flow on water holdup measurement using a conductance method. Firstly, vertical upward oil-water two-phase flow experiment is conducted in a 20 mm inner diameter (ID) pipe, in which the salinities of aqueous solutions are set as 151 ppm, 1003 ppm, 2494 ppm and 4991 ppm respectively. Experimental water-cut and mixture velocity are set as 80–100% and 0.0184–0.2576 m/s. In the experiment, three different flow patterns, i.e., dispersed oil-in-water slug flow (D OS/W), dispersed oil-in-water flow (D O/W) and very fine dispersed oil-in-water flow (VFD O/W) are observed and recorded by a high speed camera. Meanwhile, we collect the response of Vertical Multiple Electrode Array (VMEA) conductance sensor excited by a sine voltage signal. The result shows that, for VFD O/W, the water holdup from VMEA sensor shows a satisfied agreement with that of quick closing valve (QCV) method under certain salinities, i.e., 1003 ppm as well as 2494 ppm. For D OS/W flow and D O/W flow characterized by dispersed oil droplets with various sizes, considerable deviations of water holdup between VMEA sensor and QCV method under four kinds of salinity aforementioned are presented. Afterward, according to experimental analysis along with theoretical deviation, it is concluded that the deviation of the measurement system reaches its minimum when reference resistance in the measurement circuit and salinity of the aqueous solution satisfy constraint conditions, and the accuracy of water holdup using the conductance method can be improved through adjusting reference resistance to match the salinity of water phase. Finally, the recurrence plot algorithm is utilized to identify typical flow patterns mentioned above and it shows satisfied results on comprehending the discrepancies among different flow patterns, demonstrating that the recurrence plot algorithm can be effectively applied in flow pattern identification regarding oil-water flows.  相似文献   

15.
An automated, miniature, S-type Pitot tube system was created to obtain fluid velocity profiles at low flows in equipment having limited optical access, which prevents the use of standard imaging techniques. Calibration of this non-standard Pitot tube at small differential pressures with a custom, low-pressure system is also described. Application of this system to a vertical, high-pressure, water tunnel facility (HWTF) is presented. The HWTF uses static flow conditioning elements to stabilize individual gaseous, liquid, or solid particles with water for optical viewing. Stabilization of these particles in the viewing section of the HWTF requires a specific flow field, created by a combination of a radially expanding test section and a special flow conditioner located upstream of the test section. Analysis of the conditioned flow field in the viewing section of the HWTF required measurements across its diameter at three locations at 1 mm spatial resolution. The custom S-type Pitot tube system resolved pressure differences of <100 Pa created by water flowing at 5–30 cm/s while providing a relatively low response time of ~300 s despite the small diameter (<1 mm) and long length (340 mm) of the Pitot tube needed to fit the HWTF geometry. Particle imaging velocimetry measurements in the central, viewable part of the HWTF confirmed the Pitot tube measurements in this region.  相似文献   

16.
Pneumatic piston–cylinder actuators are commonly used in industry for a variety of automation and robotics applications. In order to suppress leakage, these actuators comprise seal rings which unfortunately introduce friction and affect the positioning accuracy and output force. This article investigates vibrations of the seal generated by integrated piezo actuators to reduce friction force. For this, two piezoelectric stacks are integrated in the cylinder and used to excite vibration modes. This concept was studied in a compact cylinder pneumatic actuator with a bore diameter of 5 mm and a stroke of 10 mm. Dry friction measurement shows a 52% reduction from the original friction force at a driving frequency of 18.29 kHz and vibration amplitude of 0.05 μm. In the wet friction experiments, the friction force can be reduced by 54% from the original wet friction with vibrations at amplitude of 0.04 μm.  相似文献   

17.
Oil-in-water two-phase flows are often encountered in the upstream petroleum industry. The measurement of phase flow rates is of particular importance for managing oil production and water disposal and/or water reinjection. The complexity of oil-in-water flow structures creates a challenge to flow measurement. This paper proposes a new method of two-phase flow metering, which is based on the use of dual-modality system and multidimensional data fusion. The Electrical Resistance Tomography system (ERT) is used in combination with a commercial off-the-shelf Electromagnetic Flow meter (EMF) to measure the volumetric flow rate of each constituent phase. The water flow rate is determined from the EMF with an input of the mean oil-fraction measured by the ERT. The dispersed oil-phase flow rate is determined from the mean oil-fraction and the mean oil velocity measured by the ERT cross-correlation velocity profiling. Experiments were carried out on a vertical upward oil-in-water pipe flow, 50 mm inner-diameter test section, at different total liquid flow rates covering the range of 8–16 m3/hr. The oil and water flow rate measurements obtained from the ERT and the EMF are compared to their respective references. The accuracy of these measurements is discussed and the capability of the measurement system is assessed.  相似文献   

18.
A highly integrated, Field Programmable Gate Array (FPGA) based induction measurement system for conductive flow level measurement is presented. Exploiting under-sampling and digital I/Q demodulation techniques, the system use direct digital sampling and can operate at multiple frequencies (from 100 kHz to over 10 MHz). Details are discussed in both hardware and software aspects. Simulations and experiments at 2.6 MHz and 8.3 MHz are carried out using saline solutions with conductivities of 1.8 S/m and 4.3 S/m to verify the performance of the system. Application of the system for saline level monitoring is implemented and studied, which further proves the applicability of the system in low conductivity object measurements.  相似文献   

19.
This paper presents an example where an off-line experimental technique based upon idealized flow test models is applied as an alternative method of evaluating a commercial solids flow instrument in a well-controlled environment. The systematic characteristics of a 150 mm bore commercial capacitance transducer were quantified as applied to the volumetric concentration measurement of particulate solids. Results obtained from the experimental studies are presented in terms of overall sensitivity, linearity, sensing field homogeneity, material dependence, moisture and temperature effects.  相似文献   

20.
The paper describes the design, measurement results and uncertainty analyses of the hydraulic driven piston-prover system which has been in operation at VSL since 2008. The 12-meter long, 0.6 m bore piston-prover is used for the realization of Reference Values for Gas-Volume at pressures between 1 and 65 bar(a) at several gases. The principle is based on the displacement of a piston acting as a Gas–Oil separator. The standard has a flow-rate range from 5 to 230 m3/h. The system is designed to calibrate reference meters. The Calibration and Measurement Capability (CMC) of the system is proven to be smaller than 0.1% (k=2). The paper also explains the coherence between the Gas–Oil piston-prover and other traceability generators and ‘flow rate bootstrapper systems’.  相似文献   