首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the framework of the ongoing EMPIR JRP 16ENG01 “Metrology for Hydrogen Vehicles” a main task is to investigate the influence of pressure on the measurement accuracy of Coriolis Mass Flow Meters (CFM) used at Hydrogen Refueling Stations (HRS). At a HRS hydrogen is transferred at very high and changing pressures with simultaneously varying flow rates and temperatures. It is clearly very difficult for CFMs to achieve the current legal requirements with respect to mass flow measurement accuracy at these measurement conditions. As a result of the very dynamic filling process it was observed that the accuracy of mass flow measurement at different pressure ranges is not sufficient. At higher pressures it was found that particularly short refueling times cause significant measurement deviations. On this background it may be concluded that pressure has a great impact on the accuracy of mass flow measurement. To gain a deeper understanding of this matter RISE has built a unique high-pressure test facility. With the aid of this newly developed test rig it is possible to calibrate CFMs over a wide pressure and flow range with water or base oils as test medium. The test rig allows calibration measurements under the conditions prevailing at a 70 MPa HRS regarding mass flows (up to 3.6 kg min−1) and pressures (up to 87.5 MPa).  相似文献   

2.
Dye tracer technique is a successful tool for measuring liquid flow in closed conduits and open channels. The technique is based on the continuous injection of a tracer into the flow and on the measurement of the dilution ratio. As one of the requirements, the tracer injection rate must be known and well controlled. A device was designed to obtain this control. Such device implements a volumetric flow measurement technique and provides accurate digital display readout. Experimental results indicate that the apparatus can be used to measure the injection flow rate in a range from 235 to 2000 ml min−1 with a relative error smaller than 1.5% of the reading. Even with these low injection flow, the dilution method can be applied to determine the much higher flow rates typically found in domestic or industrial outfalls as well as in artificial or natural channels. This paper also presents an application of the dilution method to flow rate measurement of an industrial outfall and the uncertainty analysis associated with the obtained values. The results indicate that the main errors of discharge estimation can arise from non-steady state flow conditions, incomplete tracer mixing, uncertainty of tracer concentration and tracer injection rate measurements.  相似文献   

3.
This paper presents the design and calibration of an ISO non-compliant orifice plate flowmeter whose intended use is for respiratory function measurements in the bidirectional air flow range ±9 L/min.The novelty of the proposed sensor consists of a plate beveled in both upstream and downstream sides: a symmetrical geometry is adopted in order to perform bidirectional measurements of flow rate. A mathematical model is introduced to quantify the influence of temperature on the sensor output. Four different positions of the pressure static taps are evaluated in order to maximize bidirectionality. An index is also introduced in order to quantitatively estimate the anti-symmetry of the sensor's response curve.Trials are carried out to evaluate the influence on sensor output of air temperatures (22 °C, 30 °C and 37 °C) at different values of relative humidity (5%, 55% and 85%). Experimental data show a quite good agreement with the theoretical model (R2>0.98 in each condition).The influence of air temperature on the sensor output is minimized by introducing a correction factor based on the theoretical model leading to measurement repeatability better than 2% in overall range of calibration. The mean sensitivity in the calibration range is about 2 kPa L−1·min allowing to obtain a sensor discrimination threshold lower than 0.2 L/min in both directions. The time constant of the whole measurement system, equal to 2.40±0.03 ms, leads to a bandwidth up to 80 Hz making the sensor suitable for respiratory function measurements.  相似文献   

4.
A compact and inexpensive iodine-stabilized diode laser system with an output at 531 nm has been applied to long gauge block measurements. Although the optical frequency of the output beam was widely modulated (modulation width of ∼22 MHz), the coherence length and interference phase stability are sufficiently long and high, respectively, for the interferometric measurement of long gauge blocks of up to 1000 mm in length. The effective uncertainty of laser frequency in the interferometric measurement was theoretically and experimentally confirmed to be less than 10−9.  相似文献   

5.
《Measurement》2007,40(7-8):797-802
A deadweight-type torque standard machine of 20 kN m rated capacity (20 kN m-DWTSM) has been designed and developed by the National Metrology Institute of Japan (NMIJ) at the National Institute of Advanced Industrial Science and Technology (AIST). Each uncertainty contribution comes mainly from the performance of each mechanical part of the 20 kN m-DWTSM. Authors evaluated the uncertainty of the mass of the linkage weights, local acceleration of gravity, influence of air buoyancy on deadweight loading, initial moment-arm length (including CMM measurement and temperature compensation), and sensitivity of the fulcrum. This report deals especially with evaluation of the remaining contributions, namely the influence of arm flexure and reference line variation at the end of the moment-arm on best measurement capability (BMC). Estimation of BMC in the 20 kN m-DWTSM gave a relative expanded uncertainty of less than 7.0 · 10−5 (k = 2) for the calibration range from 200 N m to 20 kN m.  相似文献   

6.
Longitudinal heat conduction is an important parameter in the cryogenic field, especially in cryogenic heat exchangers. In the present study, the parasitic effect of tube wall longitudinal heat conduction on temperature measurement within the tube has been studied for cryogenic gas with low mass flow rates by finite element method and experimental tests. The effects of various parameters such as tube outlet temperature, tube wall thermal conductivity, mass flow rate, and tube wall thickness have been investigated. Axial positioning errors of temperature sensor due to tube wall longitudinal heat conduction were higher for lower gas flow rates. The results showed that the tube wall thermal conductivity leads to axial heat conduction within the tube wall, but the higher tube wall thermal conductivity does not lead to bigger axial positioning error of temperature sensor at tube outlet. According to data obtained from simulations and experiments, sensor with distance of 5 mm from tube outlet had 14.92% and 8.51% temperature measurement error (with respect to gas flow temperature at tube outlet) for tube wall thermal conductivities of 16 and 400 W m−1 K−1, respectively.  相似文献   

7.
Combination of different extraction methods is an interesting work in the field of sample pretreatment. In the current study, for the first time, solid phase extraction combined with solvent-based de-emulsification dispersive liquid–liquid microextraction (SPE-SD-DLLME) was developed for preconcentration and trace detection of cadmium in water samples using flame atomic absorption spectrophotometry (FAAS). The adsorbed cadmium ions on prepared SPE (75 mL of aqueous solution) were eluted by optimized elution solvent and introduced to the second microextraction step. The effective variables of SPE including the pH of sample, flow rates, type, concentration and volume of the eluent and the effect of potentially interfering ions of the separation of cadmium were evaluated and optimized. Also, several factors that influence the SD-DLLME step such as pH, neocuproine concentration (the cadmium binding ligand), type of dispersed/de-emulsifier solvent, volume of disperser/de-emulsifier solvent and type and volume of extraction solvents were investigated. SPE-SD-DLLME provides a preconcentration factor of 165 for cadmium ions. Calibration plot was linear in the range of 0.1–50 μg L−1 with correlation of determination (r2) of 0.988. The precision and limit of detection of proposed method were 5.1% (RSD%, n = 8) and 0.03 μg L−1, respectively.  相似文献   

8.
In this paper, an improved portable biosensing system has been developed for biological compounds detection. The device is based on enzymatic chemiluminescence and magnetic immunoassay with a miniaturized flow injection module. The immunoassay procedure involved a sandwich format, in which the antigen in the sample was first captured by the immobilized primary antibody on the surface of the magnetic beads, and then recognized by the second antibody labeled with enzyme. 3-(2′-spiroadamantyl)-4-methoxy- 4-(3″-phosphoryloxy)-phenyl-1,2-dioxetane (AMPPD) as the substrate amplified the enzymatic signal for the biological compound measurement. The portable biosensing system was characterized in a series of experiments with cardiac troponin I (cTnI), a golden standard protein marker for diagnosis of myocardial infarction, as a biological substance measurement model. It provided a linear response range of cTnI from 0.1 to 50 ng mL−1 (R = 0.99). The coefficient of variation was 6.7% in the repeatability test (n = 6). The novel system has great potential applications in the rural and community hospitals and can be easily extended to a variety of protein compounds analysis.  相似文献   

9.
The objective of the study was to determine the seed spacing uniformity performance of a precision metering unit when vacuum plates with different number of holes were used. In order to meet this objective, the performances of vacuum plates with different number of holes were evaluated in the laboratory conditions by employing sticky belt tests and seed spacing values were measured computerized measurement system (CMS) for the cotton and corn seeds. Quality of feed index, multiple index, miss index as well as coefficient of precision (CP3) were considered as the performance indicators for precision seeding. The forward speed values were as selected as 1.0, 1.5 and 2.0 m s−1 while vacuum plates with hole diameter of 3.5 mm for cotton and 4.5 mm for corn seeds were used. For both, cotton and corn seeds, five different vacuum plates (20, 26, 36, 52, and 72 holes) were considered in the experiments. In the experiments, vacuum pressure was applied at 6.3 kPa. Based on the findings in this work it appears that 1.0 and 1.5 m s−1 of forward speed values were found to provide the highest performance levels for all vacuum plates. However such performance substantially decreased when forward speed increased to 2.0 m s−1. In overall, the highest performance was determined when 26 and 36 holes were used for cotton and corn, respectively.  相似文献   

10.
Measurement uncertainty is an important parameter to express measurement results including means and reliability. The uncertainty analysis of the biomedical measurement system needs to be established. A perspiration measurement system composed of several sensors was developed. We aim to estimate the measurement uncertainty of this system with several uncertainty sources, including airflow rate, air density, and inlet and outlet absolute humidity. Measurement uncertainty was evaluated and compared by the Guide to the expression of the uncertainty in measurement (GUM) method and Monte Carlo simulation. The standard uncertainty for the perspiration measurement system was 6.81 × 10−6 kg/s and the uncertainty percentage <10%. The major source of the uncertainty was airflow rate, and inlet and outlet absolute humidity. The Monte Carlo simulation could be executed easily with available spreadsheet software programs of the Microsoft Excel. GUM and Monte Carlo simulation did not differ in measurement uncertainty with precision to two decimal places. However, the sensitivity coefficient derived by GUM provided useful information to improve measurement performance, which was not evaluated with the Monte Carlo simulation method.  相似文献   

11.
This paper presents a new optical method of coordinate measuring machine (CMM) verification. The proposed system based on a single-mode fiber optical-comb pulsed interferometer with a ball lens of refractive index 2 employed as the target. The target can be used for absolute-length measurements in all directions. The laser source is an optical frequency comb, whose repetition rate is stabilized by a rubidium frequency standard. The measurement range is confirmed to be up to 10 m. The diagonals of a CMM are easier to verify by the proposed method than by the conventional artifact test method. The measurement uncertainty of the proposed method is also smaller than that of the conventional method because the proposed measurement system is less affected by air temperature; it achieves an uncertainty of approximately 7 μm for measuring lengths of 10 m. The experimental results show that the measurement accuracy depends on noise in the interference fringe, which arises from airflow fluctuations and mechanical vibrations.  相似文献   

12.
Machine tool calibration is becoming recognised as an important part of the manufacturing process. The current international standards for machine tool linear axes calibration support the use of quasi-static calibration techniques. These techniques can be time consuming but more importantly a compromise in quality due to the practical restriction on the spatial resolution of target positions on the axis under test. Continuous motion calibration techniques have the potential to dramatically increase calibration quality. Through taking several measurement values per second while the axis under test is in motion, it is possible to measure in far greater detail. Furthermore, since machine tools normally operate in dynamic mode, the calibration data can be more representative if it is captured while the machine is in motion. The drawback to measuring the axis while in motion is the potential increase in measurement uncertainty. In the following paper, different methods of continuous motion calibration are discussed. A time-based continuous motion solution is proposed as well as a novel optimisation and correlation algorithm to accurately fuse the data taken from quasi-static and continuous motion measurements. The measurement method allows for minimal quasi-static measurements to be taken while using a continuous motion measurement to enhance the calibration process with virtually no additional time constraints. The proposed method does not require any additional machine interfacing, making it a more readily accessible solution for widespread machine tool use than other techniques which require hardware links to the CNC. The result of which means a shorter calibration routine and enhanced results. The quasi-static and continuous motion measurements showed correlation to within 1 μm at the quasi-static measurement targets. An error of 13 μm was detailed on the continuous motion, but was missed using the standard test. On a larger, less accurate machine, the quasi-static and continuous motion measurements were on average within 3 μm of each other however, showed a standard deviation of 4 μm which is less than 1% of the overall error. Finally, a high frequency cyclic error was detected in the continuous motion measurement but was missed in the quasi-static measurement.  相似文献   

13.
The objectives of the present research are to accurately measure bottom shear stress under high-velocity flow conditions. To achieve high-velocity flow conditions, a laboratory-scale flume has been specially built in which flow velocity can reach over 3 m s1. Also an instrument that can directly measure bottom shear stress has been developed and validated. Then, the flow resistance has been estimated by simultaneously measuring flow velocity and bottom shear stress. It appears that the shear stress is indeed proportional to velocity squared and also to Reynolds number. On the other hand, Manning's n value and the skin friction factor are more or less uniform across all experimental cases.  相似文献   

14.
A portable device for calibration of trace humidity sensors and an adopted calibration procedure have been developed. The calibration device is based on humidity generation by permeating water through polymeric membrane tubes. Water vapour transmission rates for various polymers were experimentally determined in order to select the most suitable polymeric material. The developed trace humidity generator consists of a gas-flow polymeric hose immersed in a water reservoir thermostated by a sensor-controlled heater. Mole fractions of water vapour between 1 μmol mol−1 and 350 μmol mol−1 (equivalent to frost-point temperatures from −76 °C to −31 °C) were generated by varying either the operating temperature or gas flow. The operating temperature can be varied from 20 °C to 60 °C and kept stable within 0.1 K. Uncertainty analysis indicated that the trace humidity generator produces gas flows of constant humidity amounts with a relative expanded uncertainty less than 3.4% (k = 2) of the generated value.  相似文献   

15.
Prism signal processing is a new recursive FIR technique that facilitates the rapid tracking of sinusoidal signals, such as those used in a Coriolis Mass Flow Meter (CMFM). A Prism-based CMFM prototype has been developed using a commercial flowtube and a dual ARM processor-based transmitter, which is capable of generating flow measurement updates at 48 kHz. This has been applied in a feasibility study to the tracking of fast (e.g. 1.5 ms) injections of diesel fuel on a laboratory rig at engine speeds of up to 4000 rpm equivalent and at fuel pressures of up to 100 MPa. Due to the high level of vibration in the system, Prism-based notch filtering is used to suppress undesired modes of flowtube vibration in the sensor signal. Individual flow pulses can be detected by the system, but the relatively long period of oscillation of the flowtube compared to the fuel injection duration results in a spreading out over time of each flow pulse measurement. More precise measurement results may be obtained using a higher frequency resonant flowtube.  相似文献   

16.
A 10N·m dead weight torque standard machine (10-N·m-DWTSM) has been developed and evaluated since 2006 at the National Metrology Institute of Japan (NMIJ), a part of the National Institute of Advanced Industrial Science and Technology (AIST). Previously, the lengths of a moment arm, made of a low-thermal-expansion alloy (Super Invar), and the sensitivity limit of the fulcrum were evaluated. However, it is known that mechanical parts made of Super Invar vary in size with time. Therefore, the sensitivity limit of the fulcrum should be investigated under real calibration conditions. In this study, the moment arm lengths and the sensitivity limit of the fulcrum were re-evaluated. The moment arm lengths were found to have increased by an average of 6.3 μm in five years. The relative combined standard uncertainty of the moment arm length, warm, was re-evaluated in consideration of the uncertainty of the secular length change and was found to be 1.8 × 10−5. The sensitivity limit of the fulcrum was investigated by using a highly accurate, small-rated-capacity torque measuring device. The relative combined standard uncertainty due to the sensitivity limit of the fulcrum was 2.5 × 10−5 in the 0.1–10N·m torque range. The uncertainty budget table of the 10-N·m-DWTSM was completed. The relative expanded uncertainty of torque realized by the 10-N·m-DWTSM, Wtsm, was evaluated in the 0.1–10N·m torque range and was found to be 6.6 × 10−5, with a coverage factor, k, being equal to 2. In addition, the 10-N·m-DWTSM was compared with the existing 1-kN·m-DWTSM at NMIJ by using small-rated-capacity torque measuring devices at 5N·m and 10N·m torque steps. Two loading conditions were adopted in this comparison. The comparison results showed good agreement within the uncertainties in all cases. Thus, the torque realized by the 10-N·m-DWTSM was shown to be equivalent to that achieved by the 1-kN·m-DWTSM.  相似文献   

17.
Phase noise is an important parameter to characterise the frequency stability of oscillators and synthesised signal generators. Accurate measurement of phase noise is required for various applications in radar, communication and navigation systems. A single-channel phase-detector based phase noise measurement system is described. The system’s measurement errors and uncertainties have been analysed in details. The expanded uncertainty is about 2.7 dB for calibrating phase noise of a signal generator at 0.001–1.6 GHz for frequency offsets from 1 Hz to 100 kHz. The uncertainty budget for measuring a signal generator’s phase noise at 640 MHz is also presented.  相似文献   

18.
The paper presents an approach toward an enhancement of the measuring range of high-speed sensors for the measurement of liquid film thickness distributions based on electrical conductance. This type of sensors consists of electrodes mounted flush to the wall. The sampling of the current generated between a pair of neighboring electrode is used as a measure of the film thickness. Such sensors have a limited measuring range, which is proportional to the lateral distance between the electrodes. The range is therefore coupled to the spatial resolution. The proposed new design allows an extension of the film thickness range by combining electrode matrices of different resolution in one and the same sensor. In this way, a high spatial resolution is reached with a small thickness range, whereas a film thickness that exceeds the range of the high resolution measurement can still be acquired even though on the costs of a lower spatial resolution. A simultaneous signal acquisition with a sampling frequency of 3.2 kHz combines three measuring ranges for the characterization of a two-dimensional film thickness distribution: (1) thickness range 0–600 µm, lateral resolution 2×2 mm2, (2) thickness range 400–1300 µm, lateral resolution 4×4 mm2, and (3) thickness range 1000–3500 µm, lateral resolution 12×12 mm2. The functionality of this concept sensor is demonstrated by tests in a horizontal wavy stratified air–water flow at ambient conditions. Using flexible printed circuit board technology to manufacture the sensor makes it possible to place the sensor at the inner surface of a circular pipe.  相似文献   

19.
The detection of contaminated food in every stage of processing required new technology for fast identification and isolation of toxicity in food. Since effect of food contaminant are severe to human health, the need of pioneer technologies also increasing over last few decades. In the current study, MDA was prepared by hydrolysis of 1,1,3,3-tetramethoxypropane in HCl media and used in the electrochemical studies. The electrochemical sensor was fabricated with modified glassy carbon electrode with polyaniline. These sensors were used for detection of sodium salt of malonaldehyde and observed that a high sensitivity in the concentration range ∼1 × 10−1 M and 1 × 10−2 M. Tafel plots show the variation of over potential from  1.73 V to  3.74 V up to 10−5 mol/L indicating the lower limit of detection of the system.  相似文献   

20.
A carbon paste electrode modified with carbon nanotube and benzoylferrocene (BF) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electrocatalytic oxidation of captopril (CAP), was described. The electrode was employed to study the electrocatalytic oxidation of CAP, using cyclic voltammetry (CV), chronoamperometry (CHA) and square wave voltammetry (SWV) as diagnostic techniques. It has been found that the oxidation of CAP at the surface of modified electrode occurs at a potential of about 85 mV less positive than that of an unmodified CPE. SWV exhibits a linear dynamic range from 1.0 × 10−7 to 3.5 × 10−4 M and a detection limit of 3.0 × 10−8 M for CAP. Finally the modified electrode was used for determination of CAP in CAP tablet and urine sample.  相似文献   