This paper presents results of experiments performed on different combinations of five types of filters of varying efficiencies (MERV4, 6, 8, 11, and 14) and four types of evaporator coils with depths and fin geometries under clean and fouled conditions. The fouled conditions were obtained after injection of 600 g (1612 g/m2 of coil face area) of dust upstream of the filter–coil combination, which was meant to simulate a year of operation in the field. The air-side pressure drops of the coils and filters and air-side effective heat transfer coefficients of the coils were determined from the measurements under the clean and fouled conditions. Depending upon the filter and coil, the coil pressure drops increased in the range of 6–30% for an air velocity of 2.54 m/s. The impact was significantly greater for tests performed without an upstream filter (the coil pressure drops increased from 43% to 200%). The largest relative effect of fouling on pressure drop occurs for coils with fewer rows, primarily due to higher fin densities. The impact of fouling on air-side effective heat transfer coefficients was found to be relatively small, which ranged from −14% to 4%. In some cases, heat transfer was actually enhanced due to additional turbulence caused by the presence of dust. However, with large dust deposits, heat transfer is degraded because the dust also acts as insulation and creates an uneven air velocity.  相似文献   

2.
Airside heat and mass transfer and fluid flow characteristics of a wavy-finned-tube direct expansion air coil under cooling and dehumidifying condition have been experimentally investigated. Experiments were carried out to study the effects of operating conditions such as: air temperature, air relative humidity, air face velocity, and evaporator pressure on the airside performance (cooling capacity, dehumidification capacity, pressure drop, and heat transfer coefficient) of the coil. Charts for coil wet conditions, partially wet or totally wet, were conducted to identify the coil wet conditions in terms of the operating conditions. Two techniques, enthalpy potential method and equivalent dry-bulb temperature method, were used to analyze the data and to deduce correlations for Colburn factors for the different coil wet conditions. Comparison between the correlations predictions of the two techniques was presented.  相似文献   

3.
The multi-zone model is widely used in evaporator and condenser modeling. The basic two-zone evaporator model and three-zone condenser model might reduce to one-zone or two-zone model depending on the operating conditions. In the traditional multi-zone models, logic constraints are invoked to separate the possible running modes and trigger mode changes from one to another, which will lead to the complicated logic in implementation. A logic unconstrained multi-zone model has been developed in this paper. In the new model, all the logic constraints are transformed into continuously differentiable equations. As a result, all the equations can be solved simultaneously without any logic constraints. Numerical examples show that the new logic unconstrained multi-zone models are in good agreement with the traditional ones.  相似文献   

4.
The heat-transfer characteristics of an insulated long rectangular or square duct are analyzed by using the one-dimensional plane wedge thermal resistance (PWTR) model and plate thermal resistance (PTR) model in this study. It is found that the errors generated by the PWTR model are all positive and the errors generated by the PTR model are all negative. Thus, the combined plate wedge thermal resistance (CPWTR) model generated by paralleling PWTR and PTR models with the proportion factors of α=0.6 vs. β=0.4 (64-CPWTR model) can neutralize the positive and negative errors and obtain very accurate results in comparison with the two-dimensional numerical solutions analyzed by the CFD software. The errors generated by the one-dimensional 64-CPWTR model are within 1% for practical sizes and practical insulated thickness in air conditioning and refrigeration systems. Thus, the engineer can obtain very reliable heat transfer results when applying the one-dimensional 64-CPWTR model to an insulated rectangular duct.  相似文献   

5.
This paper describes the development and evaluation of features and virtual sensors that form the basis of a methodology for detecting and diagnosing multiple-simultaneous faults in vapor compression air conditioning equipment. The features were developed based upon a physical understanding of the system, cost considerations, and heuristics derived from experimental data and modeling results. Virtual sensors were developed in order to reduce the cost of implementation. The validity of the features and virtual sensors was evaluated using measurements from a variety of different air conditioners tested in a laboratory environment. More detailed evaluation results are presented in separate papers.  相似文献   

6.
A general distributed model with two-phase flow for refrigerant coupled with a frost model is developed for studying the dynamic behavior of an evaporator. The equations are derived in non-steady-state manner for the refrigerant and a quasi-steady state model with permeation for the frost. The complex flow and geometry of the finned tube evaporator lead to uneven wall and air temperature distributions, which in turn affect the rate of frost growth and densification along the coil depth. Results include frost accumulation and its effect on energy transfer, air off-coil temperature, refrigerant liquid dry-out position and propagation of frost formation along the coil.  相似文献   

7.
This article presents the general procedure for uncertainty calculation of net total cooling effect estimation for rating room air conditioners and packaged terminal air conditioners, by means of measurements carried out in a test bench specially designed for this purpose. The uncertainty analysis presented in this work looks for establishing a confidence degree or certainty of experimental results. It is particularly important considering that international standards related to this type of analysis are too ambiguous when treating this subject. The uncertainty analysis is on the other hand an indispensable requirement to international standard ISO 17025 [ISO, 2005. International Standard. 17025. General Requirement to Test and Calibration Laboratories Competences. International Organization for Standardization, Geneva.], which must be applied to obtain the required quality levels according to the Word Trade Organization WTO.  相似文献   

8.
The pressure drop across a heat exchanger is an important parameter, along with the heat transfer capacity. In fact, the operating cost throughout the life of the exchanger depends on the pressure losses. Therefore, it is important to be able to predict pressure drop accurately as it is to predict heat transfer.A new data set of shell-side pressure drop measurements taken during isothermal flow of brines in shell and tube evaporators was collected in the Alfa Laval laboratory. It covers several different configurations of industrial shell and tube evaporators and a wide range of operating conditions, with cross flow Reynolds number ranging from 170 to 33,000.The database is compared against two predictive procedures available in the literature for computing shell-side pressure drop, showing that no method is accurate enough for design purpose.As a further step, a new suggested procedure is presented, which extends the Wills and Johnston [Wills MJN, Johnston D. A new and accurate hand calculation method for shellside pressure drop and flow distribution. 22nd National Heat Transfer Conference, HTD N. 36. New York: ASME; 1984, p. 67–79] method to the low Reynolds number range and improve its capability to predict experimental data.  相似文献   

9.
Modeling, identification and control of air-conditioning systems   总被引:2,自引:2,他引:0  
In this paper, feedback controller design for the air-conditioning system is addressed through systematic modeling and identification. Particularly, the physical model of the system reveals the key parameter that dictates energy efficiency, and the identification procedure produces a low-order, linear model suitable for controller design. The feedback controller employed is multi-input–multi-output-based and possesses a cascade structure for dealing with the fast and slow dynamics in the system. To determine appropriate control parameters, conditions that establish performance and stability of the cascade design are given. Experiments show that the controller can simultaneously achieve satisfactory transient response in the indoor temperature, and improve energy efficiency at steady state.  相似文献   

10.
Hot gas defrost model development and validation   总被引:5,自引:0,他引:5  
This paper describes the development, validation, and application of a transient model for predicting the heat and mass transfer effects associated with an industrial air-cooling evaporator during a hot gas defrost cycle. The inputs to the model include the space dry bulb temperature, space humidity, coil geometry, frost thickness, frost density, and hot gas inlet temperature. The model predicts the time required for a complete frost melt as well as the sensible and latent loads transferred back to the conditioned space during the defrost period. The model is validated by comparing predicted results to actual defrost cycle field measurements and to results presented in previously published studies.A unique contribution of the present model is its ability to estimate parasitic space loads generated during a defrost cycle. The parasitic energy associated with the defrost process includes thermal convection, moisture re-evaporation, and extraction of the stored energy in the coil mass following a defrost cycle. Each of these factors contribute to the parasitic load on compressors connected to the defrost return. The results from the model provide quantitative information on evaporator operation during a defrost cycle which forms the basis to improve the energy efficiency of the defrost process.  相似文献   

11.
A stream analysis model was developed to simulate the behavior of accumulators and their influence on the automotive air conditioning (A/C) systems. It allows a comprehensive steady state simulation with a set of input conditions such as refrigerant vapor mass flow rate and pressure at the inlet of an accumulator. In this study, the refrigerant/oil mixture is R134a/PAG oil which are totally miscible, but could be any air conditioning refrigerant/oil, including carbon dioxide (CO2)/oil. The model accounts for all major effects inside the accumulator, such as friction, bends, sudden expansion, sudden contraction and heat exchange. The outputs are vapor quality, pressure and temperature at various positions of accumulator. In order to verify the mathematical model, experiments are performed in an experimental setup made up of real size automotive air conditioning components. The simulated results agree well with the experimental data. The simulation and experimental results show an important function of accumulators that is to determine the vapor quality into compressor, and thus has influence on the performance of whole automotive A/C systems.  相似文献   

12.
Maintaining food temperatures below critical values is the key to maximising the high quality display life of chilled foods. Studies were carried out to see if computational fluid dynamic (CFD) modelling could be used to rapidly identify the changes that would be required to an existing multi-deck display cabinet so that it would meet a higher test specification. Implementing the changes on a Pastorfrigor MV 200TP display cabinet reduced the average power consumption from 1.37 to 1.29 kW as well as significantly reducing the number of test packs which spent any time above 4 °C, from 12 to 1.  相似文献   

13.
The psychrometric chart is a useful tool for calculating the energy change between any two states and visually identifying the contribution of ‘sensible’ and ‘latent’ effects. However, the amount of work needed to move from one state to another is not read directly from the chart. In this paper, temperature and vapor pressure changes are cast into terms of minimum work relative to a dead state, and work contours are plotted on the psychrometric chart. These contours show the minimum work needed to move the state of the air further from the ambient conditions or the maximum work produced by letting a state approach the ambient conditions. A dividing line between heat pump and refrigeration operation is set on the basis total energy of the conditioned space relative to the ambient. Finally, an example is used to illustrate the implementation of the analysis.  相似文献   

14.
The thermal-hydraulic performance under conditions of an initial frost growth on the air-side surface, and for subsequent ‘refrosting’ after a defrost period is experimentally studied for folded-louvered-fin, microchannel heat exchangers. In total, five heat exchangers are considered; the thermal performances during one frost-growth cycle for four different fin geometries are compared in terms of overall heat transfer coefficient, pressure drop, and j and f factors; the defrost and refrost characteristics of two heat exchangers are compared to explore geometry effects. Typically, the performance under refrosting conditions becomes periodic and repeatable after the third or fourth refrosting cycle. The allowable frost growth period (before a defrost is required), the defrost requirement, and the thermal-hydraulic performance depend on heat exchanger geometry for the specimens used in this study.  相似文献   

15.
A new program was developed to analyze the heat transfer characteristics of fin and tube evaporators that use a zeotropic mixture refrigerant, R-407C, as the working fluid. The calculation algorithm is based on EVSIM (NIST), but a tube is segmented into several sections to provide a base unit for the calculations in this study. Therefore, two-dimensional air mal-distribution in the tube-length (horizontal) and vertical directions of the evaporator can be considered. The temperature gradient in the flow direction is traced using a discrete pattern to simulate the continuous variation found in actual evaporators. To validate the simulation results, 45 test cases in a real evaporator were performed with two different refrigerant flow path configurations using R-22 and R-407C refrigerants. The deviation between the simulations and test data was a maximum of 5.4%, and the trends were similar. The local heat transfer predictions were verified by comparing the numerical and test wall temperatures along the refrigerant flow path. Local temperature difference and the heat transfer contributions from each row are also analyzed along refrigerant flow path. And more, the impact of air mal-distribution is studied with two-dimensional four different types of velocity profiles and the significant difference in heat transfer is analyzed. The program developed in this study will be a useful tool to know all of information related with heat and mass transfer at any local point and can be used for improving the efficiency of zeotropic mixture refrigerant evaporators.  相似文献   

16.
The paper presents a new desiccant cooling cycle to be integrated in residential mechanical ventilation systems. The process shifts the air treatment completely to the return air side, so that the supply air can be cooled by a heat exchanger. Purely sensible cooling is an essential requirement for residential buildings with no maintenance guarantee for supply air humidifiers. As the cooling power is generated on the exhaust air side, the dehumidification process needs to be highly efficient to provide low supply air temperatures. Solid rotating desiccant wheels have been experimentally compared with liquid sorption systems using contact matrix absorbers and cross flow heat exchangers. The best dehumidification performance at no temperature increase was obtained in an evaporatively cooled heat exchanger with sprayed lithium chloride solution. Up to 7 g kg−1 dehumidification could be reached in an isothermal process, although the surface wetting of the first prototype was low. The process then provides inlet air conditions below 20 °C for the summer design conditions of 32 °C, 40% relative humidity. With air volume flow rates of 200 m3 h−1 the system can provide 886 W of cooling power.A theoretical model for both the contact absorber and the cross flow system has been developed and validated against experimental data for a wide range of operating conditions. A simulation study identified the optimisation potential of the system, if for example the surface wetting of the liquid desiccant can be improved.  相似文献   

17.
This paper presents a study of condensate retention on a louver-fin-and-tube air cooling coil, which is commonly used in air conditioning (A/C) systems. Compared to previously related work focusing on the influence of condensate retention on the heat and mass transfer between air and a cooling coil, the present study emphasizes the impacts of operating parameters on condensate retention on a cooling coil. A new method to describe the steady-state condensation has been suggested and a new mathematical model to represent the force balance of retained condensate developed. The mass of condensate retained has been measured experimentally under various operating conditions of a direct expansion (DX) air cooling and dehumidification system. The influences of air dry-bulb temperature, moisture content and Reynolds Number on condensate retention are discussed. The model developed relates the mass of condensate retained to condensing rate, and is successful in predicting the trends of condensate retention under normal operating conditions for air cooling applications.  相似文献   

18.
In order to analyze the influence of the deflecting ring on the noise generated by the outdoor set of a split-unit air conditioner, the flow field in the outdoor set is simulated with the CFD software STAR-CD, the relative turbulent intensities are computed and the influence of the width and contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed. The results of computation and experiment show that there is an optimal width of the deflecting ring, corresponding to the minimum noise generated by the outdoor set. In addition, the influence of the contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed and a double contoured duct is designed. The results of computation and experiment verify that the deflecting ring with double contoured duct can improve the aerodynamic performance and reduce the noise generated by the outdoor set.  相似文献   

19.
This paper presents a comparable evaluation of R600a (isobutane), R290 (propane), R134a, R22, R410A, and R32 in an optimized finned-tube evaporator, and analyzes the impact of evaporator effects on the system coefficient of performance (COP). The study relied on a detailed evaporator model derived from NIST's EVAP-COND simulation package and used the ISHED1 scheme employing a non-Darwinian learnable evolution model for circuitry optimization. In the process, 4500 circuitry designs were generated and evaluated for each refrigerant. The obtained evaporator optimization results were incorporated in a conventional analysis of the vapor compression cycle. For a theoretical cycle analysis without accounting for evaporator effects, the COP spread for the studied refrigerants was as high as 11.7%. For cycle simulations including evaporator effects, the COP of R290 was better than that of R22 by up to 3.5%, while the remaining refrigerants performed approximately within a 2% COP band of the R22 baseline for the two condensing temperatures considered.  相似文献   

20.
Air-conditioners use spirally coiled capillary tubes as an expansion device to enhance compactness of the unit. However, most empirical correlations for predicting refrigerant flow rate through capillary tubes were developed for straight capillary tubes without consideration of coiled effects. The objectives of this study are to investigate the flow characteristics of the coiled capillary tubes and to develop a generalized correlation for the mass flow rate through the coiled capillary tubes. The mass flow rate of R22 through the coiled capillary tubes and straight capillary tubes was measured for various operating conditions and tube geometries. The mass flow rates of the coiled capillary tubes decreased by 5–16% more than those of the straight capillary tubes at the same operating conditions. A generalized correlation for predicting refrigerant mass flow rate through coiled capillary tubes was developed by introducing the parameter of capillary equivalent length. The present correlation showed good predictions with the present database for R22, R407C and R410A in the straight and coiled capillary tubes, yielding average and standard deviations of 0.24% and 4.4%, respectively.  相似文献   