1.
The characteristics of thermoluminescence dosemeters (TLDs) regarding the determination of photon and neutron absorbed doses were investigated in a thermal neutron beam. Harshaw TLD-100 (LiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti) were compared with similar materials from Solid Dosimetric Detector and Method Laboratory (People's Republic of China). Harshaw TLD-700H (7LiF:Mg,Cu,P) and aluminium oxide (Al2O3:Mg,Y) from Hungary were also considered for photon dose measurement. The neutron sensitivity of the investigated materials was measured and found to be consistent with values reported by other authors. A comparison was made between the TL dose measurements and results obtained via conventional methods. An agreement within 20% was obtained, which demonstrates the ability of TLD for measuring neutron and photon doses in a mixed field, using careful calibration procedures and determining the neutron sensitivity for the usage conditions.  相似文献   

2.
This work presents an extensive study on Monte Carlo radiation transport simulation and thermoluminescent (TL) dosimetry for characterising mixed radiation fields (neutrons and photons) occurring in nuclear reactors. The feasibility of these methods is investigated for radiation fields at various locations of the Portuguese Research Reactor (RPI). The performance of the approaches developed in this work is compared with dosimetric techniques already existing at RPI. The Monte Carlo MCNP-4C code was used for a detailed modelling of the reactor core, the fast neutron beam and the thermal column of RPI. Simulations using these models allow to reproduce the energy and spatial distributions of the neutron field very well (agreement better than 80%). In the case of the photon field, the agreement improves with decreasing intensity of the component related to fission and activation products. (7)LiF:Mg,Ti, (7)LiF:Mg,Cu,P and Al(2)O(3):Mg,Y TL detectors (TLDs) with low neutron sensitivity are able to determine photon dose and dose profiles with high spatial resolution. On the other hand, (nat)LiF:Mg,Ti TLDs with increased neutron sensitivity show a remarkable loss of sensitivity and a high supralinearity in high-intensity fields hampering their application at nuclear reactors.  相似文献   

3.
Al2O3:Mg,Y ceramic thermoluminescence dosemeters were developed at the Institute of Isotopes for high dose applications at room temperatures. The glow curve of Al2O3:Mg,Y exhibits two peaks--one at 250 degrees C (I) and another peak at approximately 400 degrees C (II). In order to extend the application of these dosemeters to high temperatures, the effect of irradiation temperature was investigated using temperature controlled heating system during high dose irradiation at various temperatures (20-100 degrees C). The new calibration and measuring method has been successfully applied for dose mapping within the hermetic zone of the Paks Nuclear Power Plant even at high temperature parts of blocks.  相似文献   

4.
The photon energy response of different RADOS (Mirion Technologies) personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) thermoluminescence (TL) detectors was investigated. Three types of badges were applied. The irradiation with reference photon radiation qualities N (the narrow spectrum series), and S-Cs and S-Co nuclide radiation qualities, specified in ISO 4037 [International Organization for Standardization (ISO). X and gamma reference radiations for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy. ISO 4037. Part 1-4 (1999)], in the energy range of 16-1250 keV, were performed at the Dosimetry Laboratory Seibersdorf. The results demonstrated that a readout of a single MTS-N or MCP-N detector under the Al filter can be used to determine Hp(10) according to requirements of IEC 61066 [International Electrotechnical Commission (IEC). Thermoluminescence dosimetry systems for personal and environmental monitoring. International Standard IEC 61066 (2006)] for TL systems for personal dosimetry. The new RADOS badge with the experimental type of a holder (i.e. Cu/Al filters) is a very good tool for identifying the radiation quality (photon energy).  相似文献   

5.
The angular dependence of the thermoluminescent (TL) signal of thin alpha-Al2O3:C dosemeters was investigated for a series of beta-emitting radionuclides commonly employed in nuclear medicine and characterised by different mean energies (99Tc, 177Lu, 90Sr/90Y and 90Y). Irradiations were performed in a controlled geometry, using a properly designed irradiator intended to realistically reproduce the situation of exposure of hospital personnel to beta-emitting pharmaceuticals. Under the conditions of extended source and short source to detector distance, the TL signal of thin alpha-Al2O3:C layers per unit irradiation time was observed to be independent on the angle of incidence within acceptable limits, particularly for those radionuclides with maximum energy >500 keV. This property may be easily explained by using simple physical considerations, such as the limited thickness of the dosemeters. The results confirm that these detectors are suitable for beta-ray extremity dose measurements, when the photon contribution is negligible, as in the case considered.  相似文献   

6.
The reproducibility of measurements performed with GR-100 (LiF:Mg,Ti) from the Solid Dosimetric Detector and Method Laboratory (DML) China, GR-107 (7LiF:Mg,Ti, DML), TLD-700H (7LiF:Mg.Cu,P, Harshaw) and Al2O3:Mg,Y (Hungary) in photon and mixed photon-neutron fields was investigated. Mixed-field irradiations were performed in a thermal neutron field generated at a nuclear reactor. GR-100 sensitivity decreased after mixed-field irradiations, while no significant change was found for the other materials. Using GR-100 for the dosimetry of mixed and high-intensity fields requires careful procedures.  相似文献   

7.
The ENEA Radiation Protection Institute has been operating the only neutron personal dosimetry service in Italy since the 1970s. Since the 1980s the service has been based on PADC (poly allyl diglycol carbonate) for fast neutron dosimetry, while thermal neutron dosimetry has been performed using thermoluminescence (TL) dosemeters. Since the service was started, a number of aspects have undergone evolution. The latest and most important changes are as follows: in 1998 a new PADC material was introduced in routine, since 2001 TL thermal dosimetry has been based on LiF(Mg,Cu,P) [GR-200] and (7)LiF(Mg,Cu,P) [GR-207] detectors and since 2003 a new image analysis reading system for the fast neutron dosemeters has been used. Herein an updated summary of how the service operates and performs today is presented. The approaches to calibration and traceability to estimate the quantity of H(p)(10) are mentioned. Results obtained at the performance test of dosimetric services in the EU member states and Switzerland sponsored by the European Commission and organised by Eurados in 1999 are reported. Last but not least, quality assurance (QA) procedures introduced in the routine operation to track the whole process of dose evaluation (i.e. plastic QA, acceptance test, test etching bath reproducibility and 'dummy customer' (blind test) for each issuing monitoring period) are presented and discussed.  相似文献   

8.
Measurements of the response of thermoluminescent (TL) detectors after gamma ray doses high enough to observe signal saturation provide input to microdosimetric models which relate this gamma-ray response with the energy response after low doses of photons (gamma rays and low-energy X rays) and after high-LET irradiation. To measure their gamma ray response up to saturation, LiF:Mg,Ti (MTS-7 and MTT), LiF:Mg,Cu,P (MCP-7), CaSO4:Dy (KCD) and Al2O3:C detectors were irradiated with 60Co gamma rays over the range 1-5000 Gy. The X-ray photon energy response and TL efficiency (relative to gamma rays) after doses of beta rays and alpha particles, were also measured, for CaSO4:Dy and for Al2O3:C. Microdosimetric and track structure modelling was then applied to the experimental data. In a manner similar to LiF:Mg,Cu,P, the experimentally observed under response of alpha-Al2O3:C to X rays <100 keV, compared with cross-section calculations, is explained as a microdosimetric effect caused by the saturation of response of this detector without prior supralinearity (saturation of traps along the tracks). The enhanced X-ray photon energy response of CaSO4:Dy is related to the supralinearity observed in this material after high gamma ray doses, similarly to that in LiF:Mg,Ti. The discussed model approaches support the general rule relating dose-, energy- and ionisation density-responses in TL detectors: if their gamma ray response is sublinear prior to saturation, the measured photon energy response is lower, and if it is supralinear, it may be higher than that expected from the calculation of the interaction cross sections alone. Since similar rules have been found to apply to other solid-state detector systems, microdosimetry may offer a valuable contribution to solid-state dosimetry even prior to mechanistic explanations of physical phenomena in different TL detectors.  相似文献   

9.
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track detectors (Luxel+, Landauer) were employed to provide neutron dose data to calibrate (6)LiF:Mg,Cu,P TLDs at various distances from the isocentre. With cadmium filters employed, slow neutrons (<0.5 eV) were distinguished from fast neutrons. The average in-air photon dose equivalents per monitor unit (MU) ranged from 1.5±0.4 to 215.5±94.6 μSv at 100 and 15 cm from the isocentre, respectively. Based on the cross-calibration factors obtained with CR-39 etch-track detectors, the average in-air fast neutron dose equivalents per MU range from 10.6±3.8 to 59.1±49.9 μSv at 100 and 15 cm from the isocentre, respectively. Contribution of thermal neutrons to total neutron dose equivalent was small: 3.1±7.2 μSv per MU at 15 cm from the isocentre.  相似文献   

10.
Energy response of LiF:Mg,Ti, LiF:Mg,Cu,P and Mg2SiO4:Tb thermoluminescence dosemeters (TLDs) was measured in the range 10-150 keV for monoenergetic photons at SPring-8 of an 8-GeV synchrotron radiation facility. The photon beam was monitored by a parallel-plate free-air ionisation chamber calibrated with an uncertainty of 3%. Owing to the small dimension of the beam, a rotating holder was designed in order to irradiate TLDs uniformly. The measured responses of LiF to energy were approximately in agreement with the calculated dose absorption dependence in the soft tissue. However, two types of LiF TLDs presented the different luminescent responses to the photon energy. The response of LiF:Mg,Ti had a smooth curve, and that of LiF:Mg,Cu,P presented a local maximum at 30 keV and a local minimum at 100 keV. The Mg2SiO4:Tb response was nearly bone equivalent. Linearity of dose responses was also confirmed up to 2 Gy on each TL material.  相似文献   

11.
This paper reports initial attempts to apply a thermoluminescent (TL) reader with CCD camera to identify cases of static and dynamic exposure of personal dosemeters to doses relevant for radiation protection. Standard MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL pellets with diameter of 4.5 mm and thickness of 0.9 mm were used in a standard DOSACUS/RADOS personal dosimetry badge (holder). Pb, Cu and Al filters were installed instead of the standard Al 264 mg cm(-2) filters used in the RADOS badge. The badges were exposed statically and dynamically to X rays ranging from 28 keV (molybdenum anode) to 125 keV (tungsten anode) and to 137Cs (662 keV) gamma rays. The absorbed doses (in tissue) ranged from 20 to 100 mSv. Detectors were readout in the CCD reader and 2-D images were collected. The results obtained indicated that it was possible to identify the static, front exposure of the personal dosemeters equipped with Cu filter for doses >20 mGy for X rays up to 125 keV.  相似文献   

12.
The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have performed thermoluminescence dosimetry (TLD) audits to verify the calibration of the beams by TL powder, but TL pellets were used in this study because the element correction factor (ECF), defined as the factor to correct the variations that all TL dosemeters cannot be manufactured to have exactly the same TL efficiency, for each TL pellet could be accurately derived and be handled conveniently when compared with the powder. Also several works for the energy response of the TLDs were done for the low-energy photon beams up to 60Co, but they will be extended in this experiment to the high photon energies (up to 20 MV), which are widely used in the therapy level of a radiation. The PTW 30006 ionisation chamber was calibrated by the Korea primary standards to establish the air-kerma rates and the TL pellets were irradiated in a specially designed waterproof pellet holder in a water phantom (30 x 30 x 30 cm3) just like the IAEA postal audits programme. This result was compared with that of another type of phantom [10 (W) x 10 (L) x 10 (H) cm3 PMMA Perspex phantom for the 60Co and 6 MV photon, and 10 x 10 x 20 (H) cm3 for the 10 and 21 MV photon] for its convenient use and easy handling and installation in a hospital. The results show that the differences of the responses for the water phantom and PMMA Perspex phantom were negligible, which is contrary to the general conception that a big difference would be expected. For an application of these results to verify the therapy beams, an appropriate energy correction factor should be applied to the energies and phantom types in use.  相似文献   

13.
A method was investigated to measure gamma and fast neutron doses in phantoms exposed to an epithermal neutron beam designed for neutron capture therapy (NCT). The gamma dose component was measured by TLD-300 [CaF2:Tm] and the fast neutron dose, mainly due to elastic scattering with hydrogen nuclei, was measured by alanine dosemeters [CH3CH(NH2)COOH]. The gamma and fast neutron doses deposited in alanine dosemeters are very near to those released in tissue, because of the alanine tissue equivalence. Couples of TLD-300 and alanine dosemeters were irradiated in phantoms positioned in the epithermal column of the Tapiro reactor (ENEA-Casaccia RC). The dosemeter response depends on the linear energy transfer (LET) of radiation, hence the precision and reliability of the fast neutron dose values obtained with the proposed method have been investigated. Results showed that the combination of alanine and TLD detectors is a promising method to separate gamma dose and fast neutron dose in NCT.  相似文献   

14.
Measurements of weakly penetrating radiation in personal dosimetry present problems in the design of suitable detectors and in the interpretation of their readings. For the measurement of the individual beta radiation dose, personal dosemeters for the fingers/tips are required. LiF:Mg,Cu,P is a promising thermoluminescent (TL) material which allows the production of thin detectors with sufficient sensitivity. Dosimetric properties of two different types of extremity dosemeters, designed to measure the personal dose equivalent Hp(0.07), have been compared: LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P (TLD700H). A type test for energy response for photon and beta radiation according to ISO 4037-3 and ISO-6980 was carried out and the results for both dosemeters were compared. Simultaneous measurements with both types of dosemeters were performed at workplaces, where radiopharmaceuticals containing different radioisotopes are prepared and applied. Practices in these fields are characterized by handling of high activities at very small distances between source and skin. The results from the comparison of the two-dosemeter types are presented and analysed with respect to different radiation fields. Experiments showed a satisfactory sensitivity for the thinner dosemeter (TLD 700H) for detecting beta radiation at protection levels and a good energy response.  相似文献   

15.
The neutron response was characterised for Al(2)O(3):C material coated with (6)Li(2)CO(3). Al(2)O(3):C material, an optically stimulated luminescent (OSL) dosemeter, which is sensitive to both photons and beta radiation but is mostly insensitive to neutron radiation. The Al(2)O(3):C material was coated with (6)Li(2)CO(3) to create a material sensitive to neutrons, beta and photon radiation. In this paper, the neutron response of this new OSL material (OSLN) will be compared with various other neutron measurement technologies in laboratory and field environments.  相似文献   

16.
This investigation has been performed to test the feasibility of using K2YF5:Tb3+ crystals as thermoluminescence dosemeters (TLD). K2YF5 single crystals doped with 0.2, 10.0 and 50.0 at.% of trivalent optically active Tb3+ ions as well as K2TbF5 and undoped K2YF5 crystals have been synthesized under hydrothermal conditions. Polished crystal platelets with thickness of about 1 mm have been irradiated with X and gamma rays in order to study thermoluminescent (TL) sensitivity as well as dose and energy response in terms of the Tb3+ concentration in K2YF5. Within this concentration series, K2YF5 crystals doped with 10.0 at.% Tb3+ have been found to have maximum TL response due to a broad asymmetric TL glow peak at 269 degrees C with good linearity of dose response and reproducibility of dose measurements. After deconvolution, the main dosimetric peak has been revealed to be composed of two individual peaks, both with linear TL response behaviour, centered at 210 and 269 degrees C. As it has been proved, the linear TL signal coefficient for K2Y0.9Tb0.1F5 is almost 10 times greater than that for commercial TLD-100 (LiF:Mg,Ti), irradiated with a 137Cs gamma radiation source at the same conditions. The reported results indicate that K2YF5 crystals doped with Tb3+ have potential as promising materials for radiation dosemeters.  相似文献   

17.
Al2O3:C optical fibres were examined for potential use as real-time luminescence dosemeters for use in radiotherapy applications. The dosimetric properties of the fibres were studied in order to determine their usefulness as luminescence dosemeters. The measurements were performed by connecting the Al2O3:C fibres to a standard fused silica optical fibre and the optically stimulated luminescence (OSL) and radioluminescence (RL) were measured through the fibre. The OSL and RL responses of the Al2O3 fibre probes were measured during irradiation to determine the potential of the Al2O3:C fibres in a real-time fibre optic dosimetry system.  相似文献   

18.
Determination of gamma ray dose in mixed neutron+gamma ray fields is still a demanding task. Dosemeters used for gamma ray dosimetry are usually in some extent sensitive to neutrons and their response variations depend on neutron energy i.e., on neutron spectra. Besides, it is necessary to take into account the energy dependence of dosemeter responses to gamma rays. In this work, several types of thermoluminescent detectors (TLD) placed in different holders used for gamma ray dose determination in the mixed fields were examined. Dosemeters were from three different institutions: Ruder Boskovi? Institute (RBI), Croatia, JoZef Stefan Institute (JSI), Slovenia and Autoridad Regulatoria Nuclear (ARN), Argentina. All dosemeters were irradiated during the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002. Three accidental scenarios were reproduced and in each irradiation the dosemeters were exposed placed on the front of phantom and 'free in air'. Following types of TLDs were used: 7LiF (TLD-700), CaF2:Mn and Al2O3:Mg,Y-all from RBI; CaF2:Mn from JSI and 7LiF (TLD-700) from ARN. Reported doses were compared with the reference values as well as with the values obtained from the results of all participants. The results show satisfactory agreement with other dosimetry systems used in the Intercomparison. The influence of different types of holders and applied corrections of dosemeters' readings are discussed.  相似文献   

19.
The Hp(10) energy response of the personal dosemeter Seibersdorf and its two different filtered LiF:Mg,Ti (TLD-100) thermoluminescence (TL) detectors are investigated. A close-to-reality simulation model of the personal dosemeter badge including the wrapped detector card was implemented with the MCNP Monte Carlo N-particle transport code. The comparison of measured and computationally calculated response using a semi-empirical TL efficiency function is carried out to provide information about the quality of the results of both methods, experiment and simulation. Similar to the experimental calibration conditions, the irradiation of dosemeters centred on the front surface of the International Organization for Standardization (ISO) water slab phantom is simulated using ISO-4037 reference photon radiation qualities with mean energies between 24 keV and 1.25 MeV and corresponding ISO conversion coefficients. The comparison of the simulated and measured relative Hp(10) energy responses resulted in good agreement within some percent except for the filtered TL element at lower photon energies.  相似文献   

20.
As required by different international agreements, the regulatory body in Spain (Consejo de Seguridad Nuclear) implemented in 1992 a national automatic network (REVIRA) that continuously monitors radiation levels in order to give early warning of incidents having potential transboundary implications. The detector for environmental gamma-radiation dose rate is an active instrument based on a Geiger-Müller counter. However, the use of passive environmental dosemeters provides an additional low-cost dose estimate with an independent centralised calibration and even better basic features than active instruments. Since 1999, all 25 REVIRA stations have been monitored with passive TL environmental dosemeters based on LiF:Mg,Cu,P and operated according to the procedures established at Ciemat. This paper presents the obtained results and the further analysis considering differences in aspects such as photon energy response, inherent background or response to cosmic rays. The benefits of the use of passive environmental dosemeters in early warning networks are discussed.  相似文献   