首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The canals of 20 human dental roots were instrumented using a a step- back technique. The smear layer was removed, and the canals were obturated with composite resin. Two different techniques of compaction were used: either vertical or lateral motions were used to condense composite resin inside the root canal that was then photopolymerized layer by layer using the argon laser (488 nm). The beam was delivered into the root canal by means of an optical fiber 320 micrometers in diameter. Longitudinal and cross-sections of the samples and resin replicas of the root canals were examined using a light and scanning electron microscope. Scanning electron microscopic examination revealed that laterally compacted resin fillings showed fewer voids than those obtained by vertical compaction. In both experimental groups, adhesion of the resin to the dentin walls, pulled-out resin tags, microfailure, and resin fracture, leaving a layer of resin associated with the wall surface were observed.  相似文献   

2.
Three methods for temporarily filling root canals with calcium hydroxide pastes were compared. Each of 20 root canals of extracted, human, single-rooted teeth was shaped with hand instruments under standardized conditions up to ISO size 50 and filled using a syringe system, a lentulo spiral or an endodontic reamer. Quality of fillings was assessed radiographically and by inspecting ground preparations. Ridit (relative to an identified distribution) analysis was employed to confirm differences in frequencies of certain quality criteria obtained with various application methods. With regard to degree of obturation and occurrence of porosities, application of temporary fillings with a lentulo spiral or syringe system revealed significantly better results than application with hand instruments (reamer). No differences with regard to degree of obturation were detected when comparing results obtained with syringe or lentulo. Fewer porosities in the apical part of the root canal were seen, both on radiographs and ground sections, with the syringe system compared with the lentulo spiral. In the presence of some contradictory reports found in the literature, the present study suggests that, after straight or slightly curved root canals have been shaped up to at least ISO size 50, high quality temporary root canal fillings may be obtained by application of an aqueous suspension of calcium hydroxide with a syringe system.  相似文献   

3.
Twenty-two mesial roots of extracted human mandibular molars were divided into two groups based on root curvature and length. The mesiolingual canals were instrumented using either Flexofiles in a step-back anticurvature filing method, or they were instrumented with engine-driven 0.02 taper nickel-titanium files. Ground sections were prepared at 1-, 2.5-, and 5-mm levels from the working length. The mesiobuccal canal was used as an uninstrumented control for predentin character. Digitizing software was used to calculate the instrumented portion as a percentage of the total canal perimeter. The results indicated no significant difference in overall canal wall planning between the two groups and no significant difference at each of the three levels.  相似文献   

4.
Studies have shown significant coronal dye and bacterial leakage following exposure of sealed root canals to artificial and natural saliva. The purpose of this study was to determine the time needed for bacteria in natural saliva to contaminate the entire length of root canals obturated by lateral and vertical condensation techniques. Forty root canals were cleaned and shaped using a step-back technique. Thirty root canals were obturated with gutta-percha and root canal sealer using either lateral or vertical condensation techniques. Forty root canals were obturated without a root canal sealer and served as positive controls. After obturation, the coronal 3 mm of five root canals were sealed with sticky wax and served as negative controls. The coronal portions of the filling materials were placed in contact with human saliva and the number of days required for bacteria in saliva to penetrate the entire root canals were determined. No bacterial leakage occurred in the negative control group. Complete bacterial leakage occurred within 2 days in the positive control group. All root canals were recontaminated in less than 30 days. No statistical significant difference was found between the two methods of obturation.  相似文献   

5.
Twenty-four resin blocks with simulated curved canals of approximately 38 degrees were divided into two groups of 12 each. One group was instrumented with stainless steel K-files and the other group with nickel-titanium Lightspeed Rotary instruments. The efficiency of canal preparation was evaluated at 1, 3, 5, and 7 mm from the apex using magnified images (x4) of the radiographed blocks. The results showed that K-files caused more widening at the apical end, with a higher incidence of transportation, zipping, and elbow formation. The Lightspeed instrument stayed centered in the canals maintaining the central axis, with minimal incidence of transportation, elbow formation, and zipping. Thus, the Lightspeed instrument may be considered more suitable for efficient preparation of curved canals than the K-type file.  相似文献   

6.
The objective of this in vitro study was to compare and assess two endodontic handpieces during the preparation of simulated root canals. One hundred and sixty simulated root canals in clear resin blocks, of two angles and positions of curvature, were prepared using either Shaper files activated by the MM1500 Sonic Air handpiece (Micro-Mega, Besan?on, France) or Excalibur files activated by the W & H Excalibur 969 handpiece (W & H, Bürmoos, Austria). Files of 21-mm or 25-mm length were used. When preparing the canals, the files were used either in line with or perpendicular to the canal curvature. Preparation of the canals was carried out using a technique described in the manufacturers' literature. A variety of parameters were used to compare the handpieces, including an assessment of the canal preparation time, the deformation or fracture of instruments, loss of canal length, weight loss from the resin blocks and the overall postpreparation canal shape. Both handpieces provided an efficient and easy method of preparing and shaping the root canal with little operator fatigue. The MM1500 Sonic Air handpiece took significantly more time (P < 0.001) to prepare the canals and was associated with both more loss of working length (P < 0.05) and more loss of weight (P < 0.001). Both handpieces created a high percentage of aberrations in the shapes of prepared canals. The MM1500 Sonic Air handpiece created significantly more aberrations than the Excalibur handpiece (P < 0.05 for zip and elbow, P < 0.05 for danger zone and coronal narrow). The effects of the variables, canal curvature, file length and the plane of use of the file, on the performance of the handpieces, were also assessed.  相似文献   

7.
The transportation produced in the apical and middle areas of 30 mesiobuccal root canals of human mandibular molars was evaluated after circumferential instrumentation using stainless steel K-files (group A), nickel-titanium K-files (group B), and clockwise/counterclockwise file rotation using Flexogates (group C). The canals were instrumented with files #15 to #35 in size. Apical transportation was assessed radiographically while that occurring in the middle area was studied microscopically in cross-sections. Although apical transportation was greatest in the canals of group A, this difference was not statistically significant (P > 0.05). With respect to the middle area of the root canal, considerable transportation was observed in 7 of the 30 instrumented roots. Of these, five belonged to group A and two to group B, a difference which was not statistically significant (P > 0.05). The best results for transportation in the middle area of the canal were obtained in group C, in which no transportation occurred. This difference was significant when compared with the transportation observed in group A (P = 0.02) but not with that in group B (P > 0.05).  相似文献   

8.
Root canal instruments can be subdivided into instruments made of different alloys (stainless steel, nickel-titanium and nickel-aluminium) and instruments with different geometric forms (e.g., instruments with short cutting segments). Several types of stainless steel and titanium-based instruments are presented and assessed by a review of the current literature. In summary, flexible stainless steel instruments with noncutting tips seem to be a decisive improvement in the development of an ideal root canal instrument. They are superior to titanium-based instruments in both cutting efficiency and instrumentation of curved root canals.  相似文献   

9.
Many clinicians use ultrasonics for root-end preparations. The purpose of this study was to evaluate resected root-end surfaces of bilaterally matched human teeth for cracks before and after ultrasonic root-end preparation. Twenty matched pairs of extracted single rooted teeth were divided into two experimental groups. In group 1, root-end resection was performed on uninstrumented teeth. In group 2, root-end resection was performed after the canals were instrumented and filled with gutta-percha. All teeth in both groups received root-end preparations using ultrasonic instrumentation at low power. Two examiners evaluated the root-ends after root-end resection and again after root-end preparation using zoom magnification of 20x to 63x. The number, types, and location of cracks were mapped. There were no significant differences when gutta-percha filled roots were compared to uninstrumented roots with regard to the number or type of cracks after root-end resection or root-end preparation. In addition, there were no significant differences in the number or type of cracks following root resection and ultrasonic root-end preparation when compared to teeth with root resection alone.  相似文献   

10.
This study compared step-back preparations in curved canals of resin blocks using nickel-titanium K-files and stainless steel K-files. Forty canals in resin blocks were cross-sectioned at 3 levels: 1 to 2 mm from the apical foramen, middle of the curve, and coronal. Direct digital computer images were recorded before and after instrumentation. Superimposition of the images combined with digital subtraction computer software allowed direct measurement of area instrumented, distance of transportation, and shape analysis. Time for instrumentation was recorded. Results showed Ni-Ti files to cause significantly less transportation and remain more centered at the apical level (p < 0.05). Area removed by instrumentation was significantly greater for stainless steel files at the middle level (p < 0.05). Cross-sectional shape of the instrumented canal was not significantly different (p < 0.05). It took significantly longer to prepare a canal with Ni-Ti K-files in resin blocks compared to stainless steel (p < 0.05). Resin simulated canals showed similar results compared to canals in extracted roots using an identical methodology.  相似文献   

11.
The objective of this study was to determine the frequency, degree of curvature, and the configuration of mesiobuccal and mesiolingual root canals of mandibular first molars. The degree of curvature and configuration of root canals creates some technical difficulties to the clinician during biomechanical preparation. Therefore this knowledge is essential for successful endodontic therapy. Six hundred and ninety-seven freshly extracted mandibular first molars were used in this study. After introducing 0.8 to 15 K reamers into the mesial root canals, the teeth were radiographed in buccolingual (clinical) and mesiodistal (proximal) directions. All samples showed curvatures at varying degrees in both views. There was a significant correlation between the degree of primary curvature of mesiobuccal and mesiolingual canals in clinical directions for total samples. When the primary curvature values of the mesial root canals were evaluated in Vertucci classification, the mesiobuccal and mesiolingual canals in Vertucci type VI were found as significantly correlated (r = 0.7173, p < 0.05). A significant correlation was seen between the secondary curvature values of clinical and proximal views of mesiolingual canal in Vertucci type VI (r = 0.9891, p < 0.05). The secondary curvature values in the clinical views of mesiobuccal and mesiolingual canals were found as significantly correlated in Vertucci type II.  相似文献   

12.
The main purpose of this study was to assess the retention of Paraposts cemented with dentin-bonded resin cements in single-rooted teeth with elliptical canals. Forty-two mandibular premolars and canines were used in this study. The crowns of these teeth were removed 1 mm above the cementoenamel junction and the root canals instrumented to a depth of 8 mm to receive size 5 Paraposts. Prepared teeth were divided into six equal groups. Each group was assigned to a different cementation system at random. The six cementation systems used were: Fleck's Cement, Universal Post Cementation Kit, Prisma Universal Bond 3/Biomer, Scotchbond 2/Resiment, All-Bond 2/All-Bond C & B Cement, and Scotchbond Multi-Purpose/Resiment. Following post cementation, the teeth were stored in water at 37 degrees C for 24 hours, after which the posts were subjected to uniaxial tensile force on a testing machine until post separation occurred. Paraposts cemented with Prisma Universal Bone 3/Biomer or with Scotchbond Multi-Purpose/Resiment had significantly greater separation forces than posts cemented with any of the other cementation systems. Adhesive failure of the posts occurred in all of the specimens of the resin cement groups, whereas cohesive failure of the cement occurred in the majority of the specimens of the zinc phosphate cement group. The effects of thermocycling and post length (5 mm versus 8 mm) on the retention of Paraposts cemented with dentin-bonded resin cements were also investigated. Neither thermocycling nor post length had a significant effect on post separation force.  相似文献   

13.
A study was conducted to evaluate coronal microleakage of Super EBA and Ketac-Endo when used as sealers with single-cone gutta-percha (GP) root canal obturation. The root canals of 24 extracted human teeth were instrumented with flared preparations to a minimum #40 master apical file size. Ten teeth were obturated with a single GP cone and Super EBA as the sealer and ten teeth were obturated with a single GP cone and Ketac-Endo as the sealer. Four teeth were used as controls. Salivary bacterial microleakage studies were conducted to determine whether these sealers could prevent coronal microleakage through the root canal in the absence of a coronal tooth restoration. There was no bacterial penetration through the apical foramen for either sealer tested during the 60-day test period.  相似文献   

14.
The purpose of this study was to compare curets with a small blade to slim ultrasonic inserts on their efficacy in removing artificial deposits from the root trunk and furcation entrance areas of mandibular molars using an in vitro model simulating a clinically closed root debridement approach. The study was conducted on 100 artificial mandibular first molars (50 right side and 50 left side) with anatomical roots. Root trunks, furcation entrances, and furcation areas of each molar were colored by a coat of black model paint. The teeth were fixed in a custom acrylic model and maintained in a firm position by modified acrylic occlusal splints. The root areas were covered with a heavy rubber dam imitating gingival tissue. The model was attached to a mannequin and mounted on a dental chair. Fifty molars (25 right, 25 left) were instrumented with the experimental curets and an equivalent number of molars with the ultrasonic inserts. The instrumentation was carried out by one experienced operator, spending 4 minutes on each molar. The instrumented areas were individually analyzed to determine the percentage of deposits remaining, using a computerized imaging routine system. One-way analysis of variance was conducted to test for differences between both types of instruments. Results revealed that the curets were significantly more efficient (P < 0.01) than the ultrasonic inserts in removing paint from both root trunks and furcation entrances. These findings should be corroborated in a clinical study to determine the potential value of the instruments tested during initial therapy or supportive care of involved mandibular furcations.  相似文献   

15.
Coronal leakage has been considered as one of the major causes of failure in root canal treatment. Bacteria have been shown to penetrate the root canal obturating materials and influence the periapical tissues. Endotoxin, a component of Gram-negative bacteria, is a potent inflammatory agent and may be able to penetrate obturating materials faster than bacteria. This in vitro study examined the possible penetration of post-prepared canals by endotoxin and bacterial cells derived from mixed bacterial communities. Results showed that both bacteria and endotoxin were able to penetrate the obturating materials in post-prepared canals; however, endotoxin penetration was faster than bacterial. If one speculates that a similar sequence of events occurs clinically, then such a rapid penetration of endotoxin could lead to an early periapical reaction, with subsequent treatment failure and need for retreatment or periapical surgery. The need for an immediate and proper coronal restoration after root canal treatment is therefore reinforced.  相似文献   

16.
Nickel-titanium instruments purportedly resist deformation and loss of sharpness better than do stainless steel instruments but may be more susceptible to breakage. The processes of wear and breakage of nickel-titanium and stainless steel instruments were examined. Sixty files of five types (12 each) and three manufacturers were used. All were used repeatedly in curved canals until failure or for a maximum of 22 minutes. Each instrument was examined with scanning electron microscopy both new (control) and at spaced intervals for evidence of wear and fatigue. All new instruments were of good quality. Stainless steel instrument tended to wear the most rapidly, and next were nickel-titanium rotary instruments; the most resistant to wear were nickel-titanium hand instruments. There were few instrument separations. In general, nickel-titanium (particularly hand) instruments resisted deterioration better than did stainless steel. Nickel-titanium rotary instruments (2 of 12) had the most breakage.  相似文献   

17.
The vertical force applied to an endodontic spreader generates stress along the canal walls. Recognizing the potential for this stress may reduce the incidence of vertical root fractures. A photoelastic acrylic model was fabricated to exhibit the stress produced during obturation of curved canals using the lateral condensation technique. Twenty standardized models simulating curved canals (32 degrees) were formed within PL-2 photoelastic acrylic resin blocks. The canals were fitted with a gutta-percha point, and either a stainless-steel or nickel-titanium finger spreader was inserted. An Instron 4502 universal testing machine applied a vertical force of 20 Newtons to the spreader. Quarter wave and polarizing filters were used with backlighting to generate the fringe patterns in the models. Photographs of the resulting stress lines showed that the stainless-steel spreaders created three areas of concentrated stress. The nickel-titanium spreaders induced stress patterns spread out along the surface of the canals, thus reducing the concentration of stress and the potential for vertical root fracture.  相似文献   

18.
轧制工艺对气瓶钢板示波冲击性能的影响   总被引:2,自引:0,他引:2  
应用示波冲击试验测量了不同终轧温度下HP295钢板在系列温度下的冲击韧性,测量了冲击断口试样的横向扩张量,利用扫描电镜分析了示波冲击断口形貌,结果表明,终轧温度提高,钢的韧脆转变温度提高,钢的冲击韧性下降,裂纹扩展功下降,示波冲击温度越低,终轧温度对韧性的影响越显著,冲击韧性与冲击断口的横向扩张量和断口的形貌具有较好的对应关系。  相似文献   

19.
This study assessed in vitro apical leakage in root canals filled with gutta-percha and Ketac-Endo using different dentin conditioning and filling techniques. The root canals of 63 single-rooted teeth were instrumented and randomly divided into the following four groups: group A--canals were irrigated with 25% tannic acid and filled with Ketac-Endo and a standardized gutta-percha cone; group B--canals were irrigated with 1% NaOCl and filled as in group A; group C--canals were irrigated with 25% tannic acid and filled with Ketac-Endo and a chloroform-softened gutta-percha cone adapted to the canal walls; group D--canals were irrigated with 1% NaOCl and filled with Grossman's sealer and laterally condensed gutta-percha. After storage for 72 hours at 37 degrees C and 100% humidity, the gutta-percha was removed to a level 4 mm short of the working length, using a Peeso reamer. Teeth were immersed in India ink for 48 hours and cleared, and the coronal extent of dye penetration examined under a binocular dissecting microscope at x 15 magnification. The mean value of leakage for group A was 0.86 mm, for group B 2.23 mm, for group C 2.34 mm, and for group D 0.56 mm. Tukey's multiple comparison test disclosed significant differences (P < 0.05) between group A and groups B and C, and between group D and groups B and C. Differences between groups A and D, as well as between groups B and C, were not significant.  相似文献   

20.
Rotating instruments are becoming increasingly significant in the scaling and planing of the root surface. The objective of this in vitro study was to test various root-planing instruments on extracted teeth and then to compare the treated surfaces using scanning electron microscopy. Two manual instruments (scaler and curette) and five mechanically rotating instruments (Desmo-Clean; Perio-Set; Viking-Set; and 40-microns and 15-microns diamond finishers) were investigated. From a total of 42 teeth, six root surfaces were treated with each instrument. The results confirm the clear superiority of the manual instruments (especially the curette). The manual instruments permit good root planing with minimum ablation from the root surface and only a thin smear layer (a compound of grinding dust, dentinal fluid, and water). The best planing results by rotating instruments were achieved with the Desmo-Clean and the 15-microns diamond finisher, whose performance was almost equal to that of the manual instruments. The rotating instruments, however, were associated with higher ablation and a marked smear layer. Manual instruments remain the media of choice on easily accessible root surfaces; however, rotating instruments are of advantage in inaccessible areas (eg, furcations) because of their handling properties.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号