首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The electrohydrodynamic effect to natural convection inside the vertical channels is numerically investigated by computational fluid dynamics technique. The range of parameters considered are 104 = Ra = 107, 7.5 = V0 = 17.5 kV, and 2 = aspect ratio = 10. Flow and temperature distributions are affected with supplied voltage at the wire electrodes, and the heat transfer enhancement is significantly influenced at low Rayleigh number. The augmented volume flow rate of fluid is indicated in relation with the number of electrodes. Moreover, heat transfer enhancement also depended on the electrode arrangement while the number of electrodes is initially fixed. The relation between channel aspect ratio and number of electrodes that performs the maximum heat transfer is expressed incorporating with the optimum concerning parameters.  相似文献   

2.
Electrohydrodynamic enhanced heat transfer of the natural convection inside an enclosure with a vertical fin array is numerically investigated via a computational fluid dynamics technique. The parameters considered in a numerical modeling are supplied voltage, Rayleigh number, inclined angle, number of electrodes, electrode arrangement, number of fins, and fin length. The results reveal that the flow and heat transfer enhancements are significantly dependent on the number and position of electrodes around the fins. Moreover, the heat transfer coefficient is substantially improved by the electric field especially at the large number of fins and the long fin length.  相似文献   

3.
The numerical study of laminar forced convection inside double-flow solar air heater with electrohydrodynamic technique is investigated by finite difference method. The electric field is generated by the wire electrodes charged with DC high voltage. The mathematical modeling of computational fluid dynamics includes the interactions among electric field, flow field, and temperature field. It can be perceived that augmented heat transfer with presence of an electric field increases with the supplied voltage but decreases with the total mass flux. The optimized mass flux ratio is expressed incorporating with concerning parameter comprising of the electrode arrangement, the number of electrodes, the total heat flux at an absorbing plate, and the channel geometry.  相似文献   

4.
Numerical modeling of the electric field effect on natural convection in the partially open square cavities is investigated. The interactions between electric, flow, and temperature fields are analyzed by using a computational fluid dynamics technique. The results indicate that the flow and heat transfer enhancements are the decreasing function of Rayleigh number. Moreover, the volume flow rate and heat transfer coefficient are substantially improved by the electric field effect, especially at the low aperture size and high aperture position. The effect of number of electrodes and inclined angle to the flow and heat transfer enhancements are also achieved.  相似文献   

5.
Optimized electrode arrangement in solar air heater   总被引:1,自引:0,他引:1  
Laminar forced convection inside the solar air heater with various wire electrode arrangements are numerically examined for heat transfer enhancement using electrohydrodynamic technique. The electric field is generated by the wire electrodes charged with DC high voltage ranging from 7.5 to 17.5 kV. Reynolds number corresponding to the flow considered is between 100 and 2000. The numerical modeling of computational fluid dynamics includes the interactions among electric field, flow field, and temperature field. It is found that the enhancement of heat transfer coefficient with the presence of electric field increases in relation with the supplied voltage but decreases when the Reynolds number and the distance between electrode and channel surface are augmented. The optimized electrode arrangement, which obtains the best heat transfer enhancement is investigated incorporating with the pressure drop consideration. The heat transfer enhancement is also depended on the number of electrodes per length and the channel dimension.  相似文献   

6.
An experimental and numerical model of a solar chimney was proposed in order to predict its performance under varying geometrical features in Iraqi environmental conditions. Steady, two dimensional, turbulent flow was developed by natural convection inside an inclined solar chimney. This flow was investigated numerically at inclination angles 15° to 60°, solar heat flux 150–750 W/m2 and chimney thickness (50, 100 and 150) mm. The experimental study was conducted using a single solar chimney installed on the roof of a single room with a volume of 12 m3. The chimney was 2 m long; 2 m wide has three gap thicknesses namely: 50, 100 and 150 mm. The performance of the solar chimney was evaluated by measuring the temperature of its glass cover, the absorbing wall and the temperature and velocity of induced air. The results of numerical model showed that; the optimum chimney inclination angle was 60° to obtain the maximum rate of ventilation. At this inclination angle, the rate of ventilation was about 20% higher than 45°. Highest rate of ventilation induced with the help of solar energy was found to be 30 air changes per hour in a room of 12 m3 volumes, at a solar radiation of 750 W/m2, inclined surface angle of 60°, aspect ratio of 13.3 and chimney length of 2 m. The maximum air velocity was 0.8 m/s for a radiation intensity of 750 W/m2 at an air gap of 50 mm thickness. No reverse air flow circulation was observed even at the largest gap of 150 mm. The induced air stream by solar chimney can be used for ventilation and cooling in a natural way (passive), without any mechanical assistance.  相似文献   

7.
A solar chimney power plant consists of a translucent collector which heats the air near the ground and guides it into the base of a chimney at its centre. The buoyant air rises in the chimney and electricity is generated through one or more turbines in or near the base of the chimney. Various studies about solar chimney power plant performance have been published. Different calculation approaches with a variety of considerations have been applied to calculate chimney power plant performance. In particular, two comprehensive studies are relevant, namely those of (Bernardes, M.A.d. S., Voß, A., Weinrebe, G., 2003. Thermal and technical analyses of solar chimneys. Solar Energy 75, 511-524; Pretorius, J.P., Kröger, D.G., 2006b. Solar chimney power plant performance. Transactions of the ASME 128, 302-311). The paper compares the methods used to calculate the heat fluxes in the collector, and their effects on solar chimney performance. Reasons for the discrepancies between the predictions of the two models are given. In general the Pretorius model produces higher heat transfer coefficients and higher heat rate fluxes for both the roof and for the ground surfaces. The two approaches lead to very similar air temperature rises in the collector and thus, similar produced power.  相似文献   

8.
The greenhouse effect in the solar collector has a fundamental role to produce the upward buoyancy force in solar chimney power plant systems. This study underlines the importance of the greenhouse effect on the buoyancy-driven flow and heat transfer characteristics through the system. For this purpose, a three-dimensional unsteady model with the RNG kε turbulence closure was developed, using computational fluid dynamics techniques. In this model, to solve the radiative transfer equation the discrete ordinates (DO) radiation model was implemented, using a two-band radiation model. To simulate radiation effects from the sun's rays, the solar ray tracing algorithm was coupled to the calculation via a source term in the energy equation. Simulations were carried out for a system with the geometry parameters of the Manzanares power plant. The effects of the solar insolation and pressure drop across the turbine on the flow and heat transfer of the system were considered. Based on the numerical results, temperature profile of the ground surface, thermal collector efficiency and power output were calculated and the results were validated by comparing with experimental data of this prototype power plant. Furthermore, enthalpy rise through the collector and energy loss from the chimney outlet between 1-band and two-band radiation model were compared. The analysis showed that simulating the greenhouse effect has an important role to accurately predict the characteristics of the flow and heat transfer in solar chimney power plant systems.  相似文献   

9.
In this study, experimental and three dimensional numerical work was carried out to determine the average heat transfer coefficients for forced convection air flow over a rectangular flat plate. Three dimensional numerical simulations were obtained using a commercial finite volume based fluid dynamics code called Fluent 6.3. The experiments were performed for mass transfer using the naphthalene sublimation technique. The results were presented in terms of heat transfer parameters using the analogy between heat and mass transfer. All the experimental results are correlated within an accuracy of ± 12%.  相似文献   

10.
Heat transfer enhancement in horizontal annuli using nanofluids is investigated. Water-based nanofluid containing various volume fractions of Cu, Ag, Al2O3 and TiO2 nanoparticles is used. The addition of the different types and different volume fractions of nanoparticles were found to have adverse effects on heat transfer characteristics. For high values of Rayleigh number and high L/D ratio, nanoparticles with high thermal conductivity cause significant enhancement of heat transfer characteristics. On the other hand, for intermediate values of Rayleigh number, nanoparticles with low thermal conductivity cause a reduction in heat transfer. For Ra = 103 and Ra = 105 the addition of Al2O3 nanoparticles improves heat transfer. However, for Ra = 104, the addition of nanoparticles has a very minor effect on heat transfer characteristics.  相似文献   

11.
The dependence of the glass cover temperature, the individual heat transfer coefficients, the overall upward heat flow factor, the fraction of upward heat flow utilized for evaporation, and the rate of water evaporation on the basic parameters has been studied. A semi-empirical equation for estimation of the glass cover temperature has recently been proposed by the authors. An analysis has been made of the capability of the new method to compute accurately the glass cover temperature, the overall upward heat flow factor, the rate of water evaporation, the fraction of upward heat flow utilized for evaporation over an extensive number of combinations of the basic parameters.  相似文献   

12.
Two simple semiempirical correlations for an estimate of heat transfer in horizontal layers of superposed immiscible fluids with internal heat sources are suggested. Different boundary conditions are considered. The predicted results are compared with the known experimental correlations. The results are of interest to post-accident heat removal in fast and light water reactors.  相似文献   

13.
This work examines the natural convection heat and mass transfer near a sphere with constant wall temperature and concentration in a micropolar fluid. A coordinate transformation is used to transform the governing equations into nondimensional nonsimilar boundary layer equations and the obtained boundary layer equations are then solved by the cubic spline collocation method. Results for the local Nusselt number and the local Sherwood number are presented as functions of the vortex viscosity parameter, Schmidt number, buoyancy ratio, and Prandtl number. For micropolar fluids, higher viscosity tends to retard the flow and thus decreases the natural convection heat and mass transfer rates from the sphere with constant wall temperature and concentration. Moreover, the natural convection heat and mass transfer rates from a sphere in Newtonian fluids are higher than those in micropolar fluids.  相似文献   

14.
Effects of applying EHD and non-condensable (NC) gas contents have been experimentally studied on inter-tubular condensation of refrigerant R-134a flow. Applying of electrical field enhances condensing heat transfer coefficient (CHTC), but presence of NC gas in condensing vapour reduces this coefficient. In competition of these two effective parameters on condensation, it can be observed that at higher concentration of NC gas, the effect of electrical field on enhancement of CHTC is greatly reduced. But at lower concentration of NC gas, the effect of electrical field is more considerable, due to thickness of heat transfer boundary layer.  相似文献   

15.
This work examines the natural convection heat transfer from a horizontal isothermal cylinder of elliptic cross section in a Newtonian fluid with temperature dependent internal heat generation. The governing boundary layer equations are transformed into a non-dimensional form and the resulting nonlinear systems of partial differential equations are solved numerically applying cubic spline collocation method. Results for the local Nusselt number and the local skin-friction coefficient are presented as functions of eccentric angle for various values of heat generation parameters, Prandtl numbers and aspect ratios. Results show that both the heat transfer rate and skin friction of the elliptical cylinder with slender orientation are higher than the elliptical cylinder with blunt orientation. Moreover, an increase in the heat generation parameter for natural convection flow over an isothermal horizontal elliptic cylinder leads to a decrease in the heat transfer rate from the elliptical cylinder and an increase in the skin friction of the elliptical cylinder.  相似文献   

16.
Atit Koonsrisuk 《Solar Energy》2009,83(9):1611-1618
A solar chimney power plant derives its mechanical power from the kinetic power of the hot air which rises through a tall chimney, the air being heated by solar energy through a transparent roof surrounding the chimney. In our previous studies, the achievement of complete dynamic similarity between a prototype and its models imposed the use of different solar heat fluxes between them. It is difficult to conduct an experiment by using dissimilar heat fluxes with different physical models. Therefore, this study aimed to maintain dynamic similarity for a prototype and its models while using the same solar heat flux. The study showed that, to achieve the same-heat-flux condition, the roof radius between the prototype and its scaled models must be dissimilar, while all other remaining dimensions of the models are still similar to those of the prototype. In other words, the models are ‘partially’ geometrically similar to the prototype. The functional relationship that provides the condition for this partial similarity is proposed and its validity is proved by scaling the primitive numerical solutions of the flow. Engineering interpretations of the similarity variables are also presented.  相似文献   

17.
A.A. Lambert  S. Cuevas  J.A. del Río   《Solar Energy》2006,80(10):1296-1302
In this work, we propose the use of oscillatory laminar flows to enhance the transfer of heat from solar collectors. The idea is to explore the possibility of transferring the heat collected from a solar device to a storage tank by means of a zero-mean oscillating fluid contained in a tube. This method takes advantage of the fact that the effective thermal diffusivity of a fluid in oscillatory motion is several orders of magnitude higher than the fluid molecular diffusivity. Therefore, the axial transport of heat along the tube is substantially higher when the fluid oscillates than when the fluid is static. Also, preliminary estimations show a dramatic heat transfer enhancement using oscillatory flows compared with the forced convection of heat by standard unidirectional flows. We explore the behavior of the effective thermal diffusivity using both Newtonian and viscoelastic fluids. For the Newtonian fluid a single maximum value of this quantity is exhibited for a given oscillation frequency. In contrast, several maxima for different resonant frequencies are observed for the viscoelastic fluid. Further, the absolute maximum of the enhanced thermal diffusivity for the viscoelastic fluid is several orders of magnitude larger than that of the Newtonian fluid.  相似文献   

18.
The present work is concerned with computation of natural convection flow in a square enclosure with a centered internal conducting square block both of which are given an inclination angle. Finite volume method through the concepts of staggered grid and SIMPLE algorithm have been applied. Deferred QUICK scheme has been used to discretize the convective fluxes and central difference for diffusive fluxes. The problem of conjugate natural convection has been taken up for validating the code. The abrupt variation in the properties at the solid/fluid interface are taken care of with the harmonic mean formulation. Solution has been performed in the computational domain as a whole with proper treatment at the solid/fluid interface. Computations have been performed for Ra = 103–106, angle of inclination varying from 15° to 90° in steps of 15° and ratio of solid to fluid thermal conductivities of 0.2 and 5.0. Results are presented in terms of streamlines, isotherms, local and average Nusselt number.  相似文献   

19.
The present experimental and numerical work investigates the effect of metallic porous materials, inserted in a pipe, on the rate of heat transfer. The pipe is subjected to a constant and uniform heat flux. The effects of porosity, porous material diameter and thermal conductivity as well as Reynolds number on the heat transfer rate and pressure drop are investigated. The results are compared with the clear flow case where no porous material was used. The results obtained lead to the conclusion that higher heat transfer rates can be achieved using porous inserts at the expense of a reasonable pressure drop. Also, it is shown that for an accurate simulation of heat transfer when a porous insert is employed its effective thermal conductivity should be carefully evaluated.  相似文献   

20.
The objective of this work is to theoretically and experimentally investigate the flow and temperature distribution in a solar collector panel with an absorber consisting of horizontally inclined strips. Fluid flow and heat transfer in the collector panel are studied by means of computational fluid dynamics (CFD) calculations. Further, experimental investigations of a 12.5 m2 solar collector panel with 16 parallel connected horizontal fins are carried out. The flow distribution through the absorber is evaluated by means of temperature measurements on the backside of the absorber tubes. The measured temperatures are compared to the temperatures determined by the CFD model and there is a good similarity between the measured and calculated results.

Calculations with the CFD model elucidate the flow and temperature distribution in the collector. The influences of different operating conditions such as flow rate, properties of solar collector fluid, solar collector fluid inlet temperature and collector tilt angle are shown. The flow distribution through the absorber fins is uniform if high flow rates are used. By decreased flow rate and decreased content of glycol in the glycol/water mixture used as solar collector fluid, and by increased collector tilt and inlet temperature, the flow distribution gets worse resulting in an increased risk of boiling in the upper part of the collector panel.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号