首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Secondary ion mass spectrometry (SIMS) has seen increased application for high spatial resolution chemical imaging of complex biological surfaces. The advent and commercial availability of cluster and polyatomic primary ion sources (e.g., Au and Bi cluster and buckminsterfullerene (C(60))) provide improved secondary ion yield and decreased fragmentation of surface species, thus improving accessibility of intact molecular ions for SIMS analysis. However, full exploitation of the advantages of these new primary ion sources has been limited, due to the use of low mass resolution mass spectrometers without tandem MS to enable enhanced structural identification capabilities. Similarly, high mass resolution and high mass measurement accuracy would greatly improve the chemical specificity of SIMS. Here we combine, for the first time, the advantages of a C(60) primary ion source with the ultrahigh mass resolving power and high mass measurement accuracy of Fourier transform ion cyclotron resonance mass spectrometry. Mass resolving power in excess of 100?000 (m/Δm(50%)) is demonstrated, with a root-mean-square mass measurement accuracy below 1 part-per-million. Imaging of mouse brain tissue at 40 μm pixel size is shown. Tandem mass spectrometry of ions from biological tissue is demonstrated and molecular formulas were assigned for fragment ion identification.  相似文献   

2.
Cha S  Yeung ES 《Analytical chemistry》2007,79(6):2373-2385
Graphite-assisted laser desorption/ionization (GALDI) mass spectrometry (MS) was investigated for analysis of cerebrosides in a complex total brain lipid extract. Conventional MALDI MS and GALDI MS were compared regarding lipid analysis by using high-vacuum (HV, <10-6 Torr) LDI time-of-flight mass spectrometry and intermediate-pressure (IP, 0.17 Torr) linear ion trap mass spectrometry. Cerebrosides were not detected or detected with low sensitivity in MALDI MS because of other dominant phospholipids. By using GALDI, cerebrosides were detected as intense mass peaks without prior separation from other lipid species while mass peaks corresponding to phosphatidylcholines (PCs) were weak. The signal increase for cerebrosides and the signal decrease for PCs in GALDI MS were more significant in HV than in IP. MSn experiments of precursor ions corresponding to cerebrosides and PCs in brain lipid extract were performed to identify the detected species and distinguish isobaric ions. Twenty-two cerebroside species were detected by GALDI whereas eight cerebroside species were detected by MALDI. Sulfatides in brain lipid extract were also easily detected by GALDI MS in the negative ion mode. By forming a colloidal graphite thin film on rat brain tissue, direct lipid profiling by imaging mass spectrometry (IMS) was performed. Chemically selective images for cerebrosides and sulfatides were successfully obtained. Imaging tandem mass spectrometry (IMS/MS) was performed to generate images of specific product ions from isobaric species.  相似文献   

3.
Application of mass spectrometry imaging (MS imaging) analysis to single cells was so far restricted either by spatial resolution in the case of matrix-assisted laser desorption/ionization (MALDI) or by mass resolution/mass range in the case of secondary ion mass spectrometry (SIMS). In this study we demonstrate for the first time the combination of high spatial resolution (7 μm pixel), high mass accuracy (<3 ppm rms), and high mass resolution (R = 100?000 at m/z = 200) in the same MS imaging measurement of single cells. HeLa cells were grown directly on indium tin oxide (ITO) coated glass slides. A dedicated sample preparation protocol was developed including fixation with glutaraldehyde and matrix coating with a pneumatic spraying device. Mass spectrometry imaging measurements with 7 μm pixel size were performed with a high resolution atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) imaging source attached to an Exactive Orbitrap mass spectrometer. Selected ion images were generated with a bin width of Δm/z = ±0.005. Selected ion images and optical fluorescence images of HeLa cells showed excellent correlation. Examples demonstrate that a lower mass resolution and a lower spatial resolution would result in a significant loss of information. High mass accuracy measurements of better than 3 ppm (root-mean-square) under imaging conditions provide confident identification of imaged compounds. Numerous compounds including small metabolites such as adenine, guanine, and cholesterol as well as different lipid classes such as phosphatidylcholine, sphingomyelin, diglycerides, and triglycerides were detected and identified based on a mass spectrum acquired from an individual spot of 7 μm in diameter. These measurements provide molecularly specific images of larger metabolites (phospholipids) in native single cells. The developed method can be used for a wide range of detailed investigations of metabolic changes in single cells.  相似文献   

4.
Hadamard transform measurement of tandem Fourier-transform mass spectra   总被引:1,自引:0,他引:1  
The simultaneous collection of multiple spectra using tandem (MS/MS) and multidimensional (MS/MS/MS) mass spectrometry from multiple precursors is demonstrated to yield correspondingly enhanced sensitivity. This approach utilizes Hadamard transform deconvolution and takes advantage of the multichannel dissociation capability of Fourier-transform mass spectrometry. By application of this to an 11-component mixture, the 11 spectra of the products of dissociating 11 different combinations of six of the component molecular ions are measured; Hadamard transformation yields individual spectra of the precursor ions exhibiting a signal-to-noise improvement of 1.8x over spectra measured separately, as predicted by theory. Precursor ion selection with high specificity and product formation with high abundance reproducibility are critical; spurious peaks resulting from imperfect reproducibility can be minimized by using simultaneous equation coefficients reflecting the degree of precursor dissociation. Extension of this technique to MSn spectra is demonstrated with simultaneous MS/MS/MS monitoring of three precursors and three daughters yielding nine spectra representing the nine possible dissociation pathways. For MSn spectra, coding the product relationships for each additional step (e.g., precursor----daughter, daughter----granddaughter) requires elimination of half of the remaining ions. No ions are lost for coding in an improved Hadamard approach in which the combined daughter spectrum of the selected half of the precursors is subtracted from that of the other half.  相似文献   

5.
Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (ultra-FAIMS) combined with mass spectrometry (MS) has been applied to the analysis of standard and tryptic peptides, derived from α-1-acid glycoprotein, using electrospray and nanoelectrospray ion sources. Singly and multiply charged peptide ions were separated in the gas phase using ultra-FAIMS and detected by ion trap and time-of-flight MS. The small compensation voltage (CV) window for the transmission of singly charged ions demonstrates the ability of ultra-FAIMS-MS to generate pseudo-peptide mass fingerprints that may be used to simplify spectra and identify proteins by database searching. Multiply charged ions required a higher CV for transmission, and ions with different amino acid sequences may be separated on the basis of their differential ion mobility. A partial separation of conformers was also observed for the doubly charged ion of bradykinin. Selection on the basis of charge state and differential mobility prior to tandem mass spectrometry facilitates peptide and protein identification by allowing precursor ions to be identified with greater selectivity, thus reducing spectral complexity and enhancing MS detection.  相似文献   

6.
Tandem mass spectrometry (MS/MS) is a powerful tool for characterization of post-translationally modified proteins, including epsilon-N-acetyllysine-containing species. Previous reports indicate that epsilon-N-acetyllysine immonium ions are useful marker ions for peptides containing epsilon-N-acetyllysine, but the specificity and sensitivity of these ions for assignment of lysine acetylation by MS/MS have not been studied in detail. We investigated MS/MS data sets of 172 epsilon-N-acetyllysine tryptic peptides and 268 nonacetylated tryptic peptides to establish the utility and reliability of epsilon-N-acetyllysine immonium ions for identification and validation of acetylated peptides. Our analysis shows that the immonium ion at m/z 143 lacks specificity for lysine-acetylated peptides, whereas the derivative at m/z 126 is highly specific (98.1%). We also studied the positional effect of the epsilon-N-acetyllysine on the intensity of observed acetyllysine immonium ions. We observed an increase in acetyllysine immonium ion intensities when the acetylated lysine was N-terminally positioned in the peptide as compared to internal positions. Based on these observations we propose a validation scheme for unambiguous assignment of acetyllysine-containing peptides by MS/MS. Our analysis of epsilon-N-acetyllysine immonium ions provide a framework for investigation of MS/MS marker ion specificity and sensitivity that can be applied in studies of other types of post-translational modifications.  相似文献   

7.
High-resolution and high-accuracy Fourier transform mass spectrometry (FTMS) is becoming increasingly attractive due to its specificity. However, the speed of tandem FTMS analysis severely limits the competitive advantage of this approach relative to faster low-resolution quadrupole ion trap MS/MS instruments. Here we demonstrate an entirely FTMS-based analysis method with a 2.5-3.0-fold greater throughput than a conventional FT MS/MS approach. The method consists of accumulating together the MS/MS fragments ions from multiple precursors, with subsequent high-resolution analysis of the mixture. Following acquisition, the multiplexed spectrum is deconvoluted into individual MS/MS spectra which are then combined into a single concatenated file and submitted for peptide identification to a search engine. The method is tested both in silico using a database of MS/MS spectra as well as in situ using a modified LTQ Orbitrap mass spectrometer. The performance of the method in the experiment was consistent with theoretical expectations.  相似文献   

8.
A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the CE separation and on-line electrospray detection of carnitine and selected acylcarnitines from mixtures of analytical standards as well as extracts of fortified human urine. Chip-based CE/MS experiments in two different laboratories were carried out using a triple-quadrupole mass spectrometer and a quadrupole time-of-flight (QTOF) mass spectrometer, respectively. The glass chips used with both systems were comparably equipped with a microfabricated capillary electrophoresis (CE) channel but with different electrosprayers. The quadrupole chip-based CE/MS experiments employed a miniature coupled microsprayer, which allowed coupling of the microelectrospray process via a micro liquid junction at the exit of the CE capillary channel. Selected ion monitoring (SIM) CE/MS experiments were employed for all of the quadrupole CE/MS work. The QTOF CE/MS full-scan single MS and MS/MS experiments were carried out in another laboratory using accurate mass measurement TOF mass spectrometry techniques. The electrospray process that was employed with the QTOF system differed in that an inserted nanoelectrospray capillary needle was carefully affixed into a flat-bottomed hole that was aligned with the CE channel exit orifice. SIM CE/MS using the described quadrupole system provided acceptable ion current electropherograms from fmole levels from analytical standard solutions of carnitine and acylcarnitines that were manually injected (loaded) onto the chip. In addition, the corresponding electropherograms for human urine fortified with the target carnitine and acylcarnitines at a 10-20 microg/mL (35-124 microM) level were obtained via SIM CE/MS techniques. The measured CE separation efficiency for the SIM CE/MS electropherograms was determined to be 2860 plates (peak width at half-height method or N = 5.54(T/WO.5(2)), and carnitine and three acylcarnitines were separated in less than 48 s. In contrast, using quadrupole-TOF technologies, the same samples could be diluted by a factor of 2-4 to obtain a comparable detector response for the target compounds. In the full-scan, single mass analyzer mode (m/z 150-500), the CE separation efficiency was measured to be 2600 plates, but mass measurement accuracy was less than 5.0 ppm for the quaternary cations. In the CE/MS/MS mode, full-scan collision-induced dissociation (CID) mass spectra were obtained with a mass accuracy of < or =10 ppm for the higher mass ions and < or =27 ppm for the lower mass product ions. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric detection for these important compounds in synthetic mixtures, as well as in human urine extracts.  相似文献   

9.
Recent advances in phosphopeptide enrichment prior to mass spectrometric analysis show genuine promise for characterization of phosphoproteomes. Tandem mass spectrometry of phosphopeptide ions, using collision-activated dissociation (CAD), often produces product ions dominated by the neutral loss of phosphoric acid. Here we describe a novel method, termed Pseudo MS(n), for phosphopeptide ion dissociation in quadrupole ion trap mass spectrometers. The method induces collisional activation of product ions, those resulting from neutral loss(es) of phosphoric acid, following activation of the precursor ion. Thus, the principal neutral loss product ions are converted into a variety of structurally informative species. Since product ions from both the original precursor activation and all subsequent neutral loss product activations are simultaneously stored, the method generates a "composite" spectrum containing fragments derived from multiple precursors. In comparison to analysis by conventional MS/MS (CAD), Pseudo MS(n) shows improved phosphopeptide ion dissociation for 7 out of 10 synthetic phosphopeptides, as judged by an automated search algorithm (TurboSEQUEST). A similar overall improvement was observed upon application of Pseudo MS(n) to peptides generated by enzymatic digestion of a single phosphoprotein. Finally, when applied to a complex phosphopeptide mixture, several phosphopeptides mis-assigned by TurboSEQUEST under the conventional CAD approach were successfully identified after analysis by Pseudo MS(n).  相似文献   

10.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a central tool for proteomic analysis, yet the singly protonated tryptic peptide ions produced by MALDI are significantly more difficult to dissociate for tandem mass spectrometry (MS/MS) than the corresponding multiply protonated ions. In order to overcome this limitation, current proteomic approaches using MALDI-MS/MS involve high-energy collision-induced dissociation (CID). Unfortunately, the use of high-energy CID complicates product ion spectra with a significant proportion of irrelevant fragments while also reducing mass accuracy and mass resolution. In order to address the lack of a high-resolution, high mass accuracy MALDI-MS/MS platform for proteomics, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and a recently developed MS/MS technique termed CIRCA (for combination of infrared and collisional activation) have been applied to proteomic analysis. Here, CIRCA is shown to be suitable for dissociating singly protonated tryptic peptides, providing greater sequence coverage than either CID or infrared multiphoton dissociation (IRMPD) alone. Furthermore, the CIRCA fragmentation spectra are of sufficient quality to allow protein identification based on the MS/MS spectra alone or in concert with the peptide mass fingerprint (PMF). This is accomplished without compromising mass accuracy or mass resolution. As a result, CIRCA serves to enable MALDI-FTICR-MS/MS for high-performance proteomics experiments.  相似文献   

11.
We report the use of desorption electrospray ionization hybrid Fourier transform ion cyclotron resonance mass spectrometry (DESI-FT-ICR-MS) for the analysis of carbohydrates. Spectra of neat carbohydrates are presented along with their mass measurement accuracies and limits of detection. Furthermore, a comparison is made between the analyses of O-linked glycans from mucin by DESI-FT-ICR-MS and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry. Finally, glycans from mucin are identified by using the high mass measurement accuracy and tandem MS capabilities afforded by the hybrid FT-ICR-MS platform.  相似文献   

12.
Liquid chromatography with time-of-flight mass spectrometry (TOF-MS) and quadrupole-time-of-flight (Q-TOF) mass spectrometry/mass spectrometry (MS/MS) were used for the accurate mass analysis of sulfadimethoxine in pond water of a fish hatchery. Sulfadimethoxine is the most important sulfa antimicrobial used in aquaculture to treat bacterial disease in a wide variety of fish. Because correct identification is essential to environmental monitoring of antimicrobial pharmaceuticals, accurate mass analyses (TOF and Q-TOF-MS/MS) were compared to nominal mass measurement (quadrupole ion trap). It was known that all six members of the sulfa antimicrobial family gave a common 6-sulfanilamido ion at a nominal mass of m/z 156; thus, this ion was the focus of TOF confirmation (exact mass 156.0119 u) along with the protonated molecule (exact mass 311.0814 u). In the process of accurate mass confirmation of the 156 m/z fragment ion, a second isobaric ion (exact mass m/z 156.0773), was discovered at the same nominal mass, which was not differentiated by quadrupole ion trap. The structure was assigned as 2-4-dimethoxypyridine and is exactly the other protonated half of the sulfadimethoxine molecule. This discovery led to the subsequent use of Q-TOF-MS/MS and high-resolution identification of five other important ion fragments for the identification of sulfadimethoxine in pond water at environmental concentrations. The caveats of using low-resolution mass spectrometry without MS/MS for environmental monitoring are discussed in the light of high profile monitoring of sulfa antimicrobial pharmaceuticals in the aquatic environment.  相似文献   

13.
An isotope dilution mass spectrometric (ID/MS) method for cholesterol is described that uses capillary gas chromatography with cholesterol-13C3 as the labeled internal standard. Labeled and unlabeled cholesterol are converted to the trimethylsilyl ether. Combined capillary column gas chromatography and electron impact mass spectrometry are used to obtain the abundance ratio of the unlabeled and labeled [M+.] ions from the derivative. Quantitation is achieved by measurement of each sample between measurements of two standards whose unlabeled/labeled ratios bracket that of the sample. Seven pools were analyzed by this method: standard reference material (SRM) 1951, which consists of three frozen serum pools with low, medium, and high levels of cholesterol; SRM 1952, which consists of three freeze-dried serum pools with low, medium, and high levels of cholesterol; and SRM 909, a freeze-dried serum pool. The method is a modification of our original definitive method for cholesterol. The modified method uses much better chromatographic separations to assure specificity and a new method of implementing selected ion monitoring on a magnetic mass spectrometer to obtain high-precision measurements of ion intensity ratios on narrow gas chromatographic peaks. The modified method has a coefficient of variation (CV) of 0.22%, which is an improvement over the original method's CV of 0.36%. The measurements were found to be free of interference. The high precision and absence of bias qualify this method as a candidate definitive method.  相似文献   

14.
Desorption electrospray ionization (DESI), an ambient mass spectrometry technique, is used for trace detection of the explosives trinitrohexahydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), 2,4,6-trinitrotoluene (TNT), Pentaerythritol tetranitrate (PETN), and their plastic compositions (Composition C-4, Semtex-H, Detasheet) directly from a wide variety of surfaces (metal, plastic, paper, polymer) without sample preparation or pretreatment. Analysis of the explosives is performed under ambient conditions from virtually any surface in very short times (<5 s) including confirmatory tandem mass spectrometry (MS/MS) experiments, while retaining the sensitivity and specificity that mass spectrometry offers. Increased selectivity is obtained both by MS/MS and by performing additional experiments in which additives are included in the spray solvent. These reactive DESI experiments (reactions accompanying desorption) produce such ions as the chloride and trifluoroacetate adducts of RDX and HMX or the Meisenheimer complex of TNT. Desorption atmospheric pressure chemical ionization, a variant of DESI that uses gas-phase ions generated by atmospheric pressure corona discharges of toluene or other organic compounds, provides evidence for a heterogeneous-phase (gaseous ion/absorbed analyte) charge-transfer mechanism of DESI ionization in the case of explosives. Plastic explosives on surfaces were analyzed directly as fingerprints, without sample preparation, to test DESI as a possible method for in situ detection of explosives-contaminated surfaces. DESI also allowed detection of explosives in complex matrixes, including lubricants, household cleaners, vinegar, and diesel fuel. Absolute limits of detection for the neat explosives were subnanogram in all cases and subpicogram in the case of TNT. The DESI response was linear over 3 orders of magnitude for TNT. Quantification of RDX on paper gave a precision (RSD) of 2.3%. Pure water could be used as the spray solution for DESI, and it showed ionization efficiencies for RDX in the negative ion mode similar to that given by methanol/water. DESI represents a simple and rapid way to detect explosives in situ with high sensitivity and specificity and is especially useful when they are present in complex mixtures or in trace amounts on ordinary environmental surfaces.  相似文献   

15.
Currently, proton-transfer reaction mass spectrometry (PTR-MS) allows for quantitative determination of volatile organic compounds in real time at concentrations in the low ppt range, but cannot differentiate isomers or isobaric molecules, using the conventional quadrupole mass filter. Here we pursue the application of linear quadrupole ion trap (LIT) mass spectrometry in combination with proton-transfer reaction chemical ionization to provide the advantages of specificity from MS/MS. A commercial PTR-MS platform composed of a quadrupole mass filter with the addition of end cap electrodes enabled the mass filter to operate as a linear ion trap. The rf drive electronics were adapted to enable the application of dipolar excitation to opposing rods, for collision-induced dissociation (CID) of trapped ions. This adaptation enabled ion isolation, ion activation, and mass analysis. The utility of the PTR-LIT was demonstrated by distinguishing between the isomeric isoprene oxidation pair, methyl vinyl ketone (MVK) and methacrolein (MACR). The CID voltage was adjusted to maximize the m/ z 41 to 43 fragment ratio of MACR while still maintaining adequate sensitivity. Linear calibration curves for MVK and MACR fragments at m/ z 41 and 43 were obtained with limits of detection of approximately 100 ppt, which should enable ambient measurements. Finally, the PTR-LIT method was compared to an established GC/MS method by quantifying MVK and MACR production during a smog chamber isoprene-NO x irradiation experiment.  相似文献   

16.
First examples of highly charged ions in mass spectrometry (MS) produced from the solid state without using solvent during either sample preparation or mass measurement are reported. Matrix material, matrix/analyte homogenization time and frequency, atmospheric pressure (AP) to vacuum inlet temperature, and mass analyzer ion trap conditions are factors that influence the abundance of the highly charged ions created by laserspray ionization (LSI). LSI, like matrix-assisted laser desorption/ionization (MALDI), uses laser ablation of a matrix/analyte mixture from a surface to produce ions. Preparing the matrix/analyte sample without the use of solvent provides the ability to perform total solvent-free analysis (TSA) consisting of solvent-free ionization and solvent-free gas-phase separation using ion mobility spectrometry (IMS) MS. Peptides and small proteins such as non-β-amyloid components of Alzheimer's disease and bovine insulin are examples in which LSI and TSA were combined to produce multiply charged ions, similar to electrospray ionization, but without the use of solvent. Advantages using solvent-free LSI and IMS-MS include simplicity, rapid data acquisition, reduction of sample complexity, and the potential for an enhanced effective dynamic range. This is achieved by more inclusive ionization and improved separation of mixture components as a result of multiple charging.  相似文献   

17.
We have recently developed a new mass spectrometry method, the STEP (statistical test of equivalent pathways) analysis that uses ion abundances in two tandem mass spectrometry experiments to obtain genealogy information about product ions present in mass spectra. The method requires minimal sample, and it can be performed using a conventional quadrupole ion trap mass spectrometer. To obtain genealogy information, STEP ratios are calculated by comparing the relative abundances of product ions in two MS/MS experiments. These ratios are directly related to the origin of the product ions. Product ions that result directly from the precursor ion always have STEP ratios that are 相似文献   

18.
While investigating the in-source CID fragmentation of nonsteroidal antiinflammatory drugs (NSAIDs), it was noticed that the same fragment ion (nominal mass) formed in either positive or negative ion electrospray for a suite of NSAIDs. For example, ibuprofen with a molecular mass of 206, fragments to the m/z 161 ion in negative ion from its deprotonated molecule (m/z 205, [M - H]-) and fragments to the m/z 161 ion in positive ion from its protonated molecule (m/z 207, [M + H]+). This fragment ion was euphemistically called a "twin ion"because of the same nominal mass despite opposite charge. The CID fragmentation of the twin ions was confirmed also by LC/MS/MS ion trap. Accurate mass measurements in negative ion show that the loss was due to CO2 (measured loss of 43.9897 atomic mass units (u) versus calculated loss of 43.9898 u for N = 10) and in positive ion the loss is due to HCOOH (measured loss of 46.0048 u versus calculated loss of 46.0055 u, N = 10). It was realized that, in fact, the ions were not "identical mass twins of opposite charge" but separated in accurate mass by two electrons. The accurate mass measurement by liquid chromatography/time-of-flight-mass spectrometry (LC/TOF-MS) can distinguish between the two fragment ions of ibuprofen (161.13362 +/- 0.00019 and 161.13243 +/- 0.00014 for N = 20). This experiment was repeated for two other NSAIDs, and the mass of an electron was measured as the difference between the twin ions, which was 0.00062 u +/- 14.8% relative standard deviation (N = 20 analyses). Thus, the use of continuous calibration makes it possible to measure the mass of an electron within one significant figure using the NSAID solution. This result shows the importance of including electron mass in accurate mass measurements and the value of a benchmark test for LC/TOF-MS mass accuracy.  相似文献   

19.
Molecular formulas have been assigned for 4626 individual Suwannee River fulvic acids based on accurate mass measurements from ions generated by electrospray ionization and observed by ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS). Formula assignments were possible because of the mass accuracy of FTICR MS at high field (9.4 T) and the regular mass spacing patterns found in fulvic acid mixtures. Sorting the 4626 individually observed ions according to Kendrick mass defect and nominal mass series (z* score) revealed that all could be assigned to 1 of 266 distinct homologous series that differ in oxygen content and double bond equivalence. Tandem mass spectrometry based on infrared multiphoton dissociation identified labile fragments of fulvic acid molecules, whose chemical formulas led to plausible structures consistent with degraded lignin as a source of Suwannee River fulvic acids.  相似文献   

20.
Molecular weight distributions of fulvic acid from the Suwannee River, Georgia, were investigated by electrospray ionization/quadrupole mass spectrometry (ESI/ QMS), and fragmentation pathways of specific fulvic acid masses were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry (ESI/MST/ MS). ESI/QMS studies of the free acid form of low molecular weight poly(carboxylic acid) standards in 75% methanol/25% water mobile phase found that negative ion detection gave the optimum generation of parent ions that can be used for molecular weight determinations. However, experiments with poly(acrylic acid) mixtures and specific high molecular weight standards found multiply charged negative ions that gave a low bias to molecular mass distributions. The number of negative charges on a molecule is dependent on the distance between charges. ESI/MST/MS of model compounds found characteristic water loss from alcohol dehydration and anhydride formation, as well as CO2 loss from decarboxylation, and CO loss from ester structures. Application of these fragmentation pathways to specific masses of fulvic acid isolated and fragmented by ESI/MST/MS is indicative of specific structures that can serve as a basis for future structural confirmation after these hypothesized structures are synthesized.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏