首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study investigates the properties of electrolyzed oxidizing (EO) water for the inactivation of pathogen and to evaluate the chemically modified solutions possessing properties similar to EO water in killing Escherichia coli O157:H7. A five-strain cocktail (10(10) CFU/ml) of E. coli O157:H7 was subjected to deionized water (control), EO water with 10 mg/liter residual chlorine (J.A.W-EO water), EO water with 56 mg/liter residual chlorine (ROX-EO water), and chemically modified solutions. Inactivation (8.88 log10 CFU/ml reduction) of E. coli O157:H7 occurred within 30 s after application of EO water and chemically modified solutions containing chlorine and 1% bromine. Iron was added to EO or chemically modified solutions to reduce oxidation-reduction potential (ORP) readings and neutralizing buffer was added to neutralize chlorine. J.A.W-EO water with 100 mg/liter iron, acetic acid solution, and chemically modified solutions containing neutralizing buffer or 100 mg/liter iron were ineffective in reducing the bacteria population. ROX-EO water with 100 mg/liter iron was the only solution still effective in inactivation of E. coli O157:H7 and having high ORP readings regardless of residual chlorine. These results suggest that it is possible to simulate EO water by chemically modifying deionized water and ORP of the solution may be the primary factor affecting microbial inactivation.  相似文献   

2.
The effects of chlorine and pH on the bactericidal activity of electrolyzed (EO) water were examined against Escherichia coli O157:H7 and Listeria monocytogenes. The residual chlorine concentration of EO water ranged from 0.1 to 5.0 mg/l, and the pH effect was examined at pH 3.0, 5.0, and 7.0. The bactericidal activity of EO water increased with residual chlorine concentration for both pathogens, and complete inactivation was achieved at residual chlorine levels equal to or higher than 1.0 mg/l. The results showed that both pathogens are very sensitive to chlorine, and residual chlorine level of EO water should be maintained at 1.0 mg/l or higher for practical applications. For each residual chlorine level, bactericidal activity of EO water increased with decreasing pH for both pathogens. However, with sufficient residual chlorine (greater than 2 mg/l), EO water can be applied in a pH range between 2.6 (original pH of EO water) and 7.0 while still achieving complete inactivation of E. coli O157:H7 and L. monocytogenes.  相似文献   

3.
This study was conducted to evaluate the efficacy of calcinated calcium, 200 ppm chlorine water (1% active chlorine), and sterile distilled water in killing Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes on the surfaces of spot-inoculated tomatoes. Inoculated tomatoes were sprayed with calcinated calcium, chlorinated water, or sterile distilled water (control) and hand rubbed for 30 s. Populations of E coli O157:H7, Salmonella, and L. monocytogenes in the rinse water and in the residual (0.1% peptone) wash solution were determined. Treatment with 200 ppm chlorine and calcinated calcium resulted in 3.40- and 7.85-log10 reductions of E. coli O157:H7, respectively, and 2.07- and 7.36-log10 reductions of Salmonella, respectively. Treatment with 200 ppm chlorine and calcinated calcium reduced L monocytogenes numbers by 2.27 and 7.59 log10 CFU per tomato, respectively. The findings of this study suggest that calcinated calcium could be useful in controlling pathogenic microorganisms in fresh produce.  相似文献   

4.
ABSTRACT: The efficacy of electrolyzed oxidizing (EO) and acidified chlorinated water (45 ppm residual chlorine) was evaluated in killing Escherichia coli O157:H7 and Listeria monocytogenes on lettuce. After surface inoculation, each leaf was immersed in 1.5 L of EO or acidified chlorinated water for 1 or 3 min at 22 °C. Compared to a water wash only, the EO water washes significantly decreased mean populations of E. coli O157:H7 and L. monocytogenes by 2.41 and 2.65 log10 CFU per lettuce leaf for 3 min treatments, respectively (p < 0.05). However, the difference between the bactericidal activity of EO and acidified chlorinated waters was not significant (p > 0.05). Change in the quality of lettuce subjected to the different wash treatments was not significant at the end of 2 wk of storage.  相似文献   

5.
A study was conducted to evaluate the efficacy of electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water in killing Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes on the surfaces of spot-inoculated tomatoes. Inoculated tomatoes were sprayed with electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water (control) and rubbed by hand for 40 s. Populations of E. coli O157:H7, Salmonella, and L. monocytogenes in the rinse water and in the peptone wash solution were determined. Treatment with 200-ppm chlorine water and electrolyzed acidic water resulted in 4.87- and 7.85-log10 reductions, respectively, in Escherichia coli O157:H7 counts and 4.69- and 7.46-log10 reductions, respectively, in Salmonella counts. Treatment with 200-ppm chlorine water and electrolyzed acidic water reduced the number of L. monocytogenes by 4.76 and 7.54 log10 CFU per tomato, respectively. This study's findings suggest that electrolyzed acidic water could be useful in controlling pathogenic microorganisms on fresh produce.  相似文献   

6.
ABSTRACT:  Antibacterial activity of electrolyzed oxidizing (EO) water prepared from 0.05% or 0.10% (w/v) sodium chloride (NaCl) solutions against indigenous bacteria associated with fresh strawberries ( Fragaria × ananassa ) was evaluated. The efficacy of EO water and sodium hypochlorite (NaOCl) solution in eliminating and controlling the growth of Listeria monocytogenes and Escherichia coli O157:H7 inoculated onto strawberries stored at 4 ± 1 °C up to 15 d was investigated at exposure time of 1, 5, or 10 min. Posttreatment neutralization of fruit surfaces was also determined. More than 2 log10 CFU/g reductions of aerobic mesophiles were obtained in fruits washed for 10 or 15 min in EO water prepared from 0.10% (w/v) NaCl solution. Bactericidal activity of the disinfectants against L. monocytogenes and E. coli O157:H7 was not affected by posttreatment neutralization, and increasing exposure time did not significantly increase the antibacterial efficacy against both pathogens. While washing fruit surfaces with distilled water resulted in 1.90 and 1.27 log10 CFU/mL of rinse fluid reduction of L. monocytogenes and E. coli O157:H7, respectively, ≥ 2.60 log10 CFU/mL of rinse fluid reduction of L. monocytogenes and up to 2.35 and 3.12 log10 CFU/mL of rinse fluid reduction of E. coli O157:H7 were observed on fruit surfaces washed with EO water and NaOCl solution, respectively. Listeria monocytogenes and E. coli O157:H7 populations decreased over storage regardless of prior treatment. However, EO water and aqueous NaOCl did not show higher antimicrobial potential than water treatment during refrigeration storage.  相似文献   

7.
This study was intended to evaluate the bactericidal effect of electrolyzed oxidizing water (EOW) and chlorinated water on populations of Salmonella enterica, Escherichia coli O157:H7, and Listeria monocytogenes inoculated on avocados (Persea americana var. Hass). In the first experiment, inoculated avocados were treated with a water wash applied by spraying tap water containing 1 mg/liter free chlorine for 15 s (WW); WW treatment and then spraying sodium hypochlorite in water containing 75 mg/liter free chlorine for 15 s (Cl75); WW treatment and then spraying alkaline EOW for 30 s (AkEW) and then spraying acid EOW (AcEW) for 15 s; and spraying AkEW and then AcEW. In another experiment, the inoculated avocados were treated by spraying AkEW and then AcEW for 15, 30, 60, or 90 s. All three pathogen populations were lowered between 3.6 and 3.8 log cycles after WW treatment. The application of Cl75 did not produce any further reduction in counts, whereas AkEW and then AcEW treatment resulted in significantly lower bacterial counts for L. monocytogenes and E. coli O157:H7 but not for Salmonella. Treatments with AkEW and then AcEW produced a significant decrease in L. monocytogenes, Salmonella, and E. coli O157:H7 populations, with estimated log reductions of 3.9 to 5.2, 5.1 to 5.9, and 4.2 to 4.9 log CFU/cm2, respectively. Spraying AcEW for more than 15 s did not produce any further decrease in counts of Salmonella or E. coli O157:H7, whereas L. monocytogenes counts were significantly lower after spraying AcEW for 60 s. Applying AkEW and then AcEW for 15 or 30 s seems to be an effective alternative to reduce bacterial pathogens on avocado surfaces.  相似文献   

8.
The effects of electrolyzed oxidizing (EO) water on reducing Listeria monocytogenes contamination on seafood processing surfaces were studied. Chips (5 x 5 cm(2)) of stainless steel sheet (SS), ceramic tile (CT), and floor tile (FT) with and without crabmeat residue on the surface were inoculated with L. monocytogenes and soaked in tap or EO water for 5 min. Viable cells of L. monocytogenes were detected on all chip surfaces with or without crabmeat residue after being held at room temperature for 1 h. Soaking contaminated chips in tap water resulted in small-degree reductions of the organism (0.40-0.66 log cfu/chip on clean surfaces and 0.78-1.33 log cfu/chip on dirty surfaces). Treatments of EO water significantly (p<0.05) reduced L. monocytogenes on clean surfaces (3.73 log on SS, 4.24 log on CT, and 5.12 log on FT). Presence of crabmeat residue on chip surfaces reduced the effectiveness of EO water on inactivating Listeria cells. However, treatments of EO water also resulted in significant reductions of L. monocytogenes on dirty surfaces (2.33 log on SS and CT and 1.52 log on FT) when compared with tap water treatments. The antimicrobial activity of EO water was positively correlated with its chlorine content. High oxidation-reduction potential (ORP) of EO water also contributed significantly to its antimicrobial activity against L. monocytogenes. EO water was more effective than chlorine water on inactivating L. monocytogenes on surfaces and could be used as a chlorine alternative for sanitation purpose. Application of EO water following a thorough cleaning process could greatly reduce L. monocytogenes contamination in seafood processing environments.  相似文献   

9.
The effectiveness of electrolyzed (EO) water for killing Campylobacter jejuni on poultry was evaluated. Complete inactivation of C. jejuni in pure culture occurred within 10 s after exposure to EO or chlorinated water, both of which contained 50 mg/l of residual chlorine. A strong bactericidal activity was also observed on the diluted EO water (containing 25 mg/l of residual chlorine) and the mean population of C. jejuni was reduced to less than 10 CFU/ml (detected only by enrichment for 48 h) after 10-s treatment. The diluted chlorine water (25 mg/l residual chlorine) was less effective than the diluted EO water for inactivation of C. jejuni. EO water was further evaluated for its effectiveness in reducing C. jejuni on chicken during washing. EO water treatment was equally effective as chlorinated water and both achieved reduction of C. jejuni by about 3 log10 CFU/g on chicken, whereas deionized water (control) treatment resulted in only 1 log10 CFU/g reduction. No viable cells of C. jejuni were recovered in EO and chlorinated water after washing treatment, whereas high populations of C. jejuni (4 log10 CFU/ml) were recovered in the wash solution after the control treatment. Our study demonstrated that EO water was very effective not only in reducing the populations of C. jejuni on chicken, but also could prevent cross-contamination of processing environments.  相似文献   

10.
To evaluate the potential of using electrolyzed oxidizing (EO) water for controlling Escherichia coli O157:H7 in water for livestock, the effects of water source, electrolyte concentration, dilution, storage conditions, and bacterial or fecal load on the oxidative reduction potential (ORP) and bactericidal activity of EO water were investigated. Anode and combined (7:3 anode:cathode, vol/vol) EO waters reduced the pH and increased the ORP of deionized water, whereas cathode EO water increased pH and lowered ORP. Minimum concentrations (vol/vol) of anode and combined EO waters required to kill 10(4) CFU/ml planktonic suspensions of E. coli O157:H7 strain H4420 were 0.5 and 2.0%, respectively. Cathode EO water did not inhibit H4420 at concentrations up to 16% (vol/vol). Higher concentrations of anode or combined EO water were required to elevate the ORP of irrigation or chlorinated tap water compared with that of deionized water. Addition of feces to EO water products (0.5% anode or 2.0% combined, vol/vol) significantly reduced (P < 0.001) their ORP values to < 700 mV in all water types. A relationship between ORP and bactericidal activity of EO water was observed. The dilute EO waters retained the capacity to eliminate a 10(4) CFU/ml inoculation of E. coli O157:H7 H4420 for at least 70 h regardless of exposure to UV light or storage temperature (4 versus 24 degrees C). At 95 h and beyond, UV exposure reduced ORP, significantly more so (P < 0.05) in open than in closed containers. Bactericidal activity of EO products (anode or combined) was lost in samples in which ORP value had fallen to < or = 848 mV. When stored in the dark, the diluted EO waters retained an ORP of > 848 mV and bactericidal efficacy for at least 125 h; with refrigeration (4 degrees C), these conditions were retained for at least 180 h. Results suggest that EO water may be an effective means by which to control E. coli O157:H7 in livestock water with low organic matter content.  相似文献   

11.
Ozone (3 ppm), chlorine dioxide (3 and 5 ppm), chlorinated trisodium phosphate (100- and 200-ppm chlorine), and peroxyacetic acid (80 ppm) were assessed for reduction of Escherichia coli O157:H7 and Listeria monocytogenes in an aqueous model system and on inoculated produce. Initially, sanitizer solutions were inoculated to contain approximately 10(6) CFU/ml of either pathogen, after which aliquots were removed at 15-s intervals over a period of 5 min and approximately plated to determine log reduction times. Produce was dip inoculated to contain approximately 10(6) E. coli O157:H7 or L. monocytogenes CFU/g, held overnight, submerged in each sanitizer solution for up to 5 min, and then examined for survivors. In the model system study, both pathogens decreased > 5 log following 2 to 5 min of exposure, with ozone being most effective (15 s), followed by chlorine dioxide (19 to 21 s), chlorinated trisodium phosphate (25 to 27 s), and peroxyacetic acid (70 to 75 s). On produce, ozone and chlorine dioxide (5 ppm) were most effective, reducing populations approximately 5.6 log, with chlorine dioxide (3 ppm) and chlorinated trisodium phosphate (200 ppm chlorine) resulting in maximum reductions of approximately 4.9 log. Peroxyacetic acid was the least effective sanitizer (approximately 4.4-log reductions). After treatment, produce samples were stored at 4 degrees C for 9 days and quantitatively examined for E. coli O157:H7, L. monocytogenes, mesophilic aerobic bacteria, yeasts, and molds. Populations of both pathogens remained relatively unchanged, whereas numbers of mesophilic bacteria increased 2 to 3 log during storage. Final mold and yeast populations were significantly higher than initial counts for chlorine dioxide- and ozone-treated produce. Using the nonextended triangle test, whole apples exposed to chlorinated trisodium phosphate (200 ppm chlorine) and shredded lettuce exposed to peroxyacetic acid were statistically different from the other treated samples.  相似文献   

12.
Electrolyzed oxidizing water is a relatively new concept that has been utilized in agriculture, livestock management, medical sterilization, and food sanitation. Electrolyzed oxidizing (EO) water generated by passing sodium chloride solution through an EO water generator was used to treat alfalfa seeds and sprouts inoculated with a five-strain cocktail of nalidixic acid resistant Escherichia coli O157:H7. EO water had a pH of 2.6, an oxidation-reduction potential of 1150 mV and about 50 ppm free chlorine. The percentage reduction in bacterial load was determined for reaction times of 2, 4, 8, 16, 32, and 64 min. Mechanical agitation was done while treating the seeds at different time intervals to increase the effectiveness of the treatment. Since E. coli O157:H7 was released due to soaking during treatment, the initial counts on seeds and sprouts were determined by soaking the contaminated seeds/sprouts in 0.1% peptone water for a period equivalent to treatment time. The samples were then pummeled in 0.1% peptone water and spread plated on tryptic soy agar with 5 microg/ml of nalidixic acid (TSAN). Results showed that there were reductions between 38.2% and 97.1% (0.22-1.56 log(10) CFU/g) in the bacterial load of treated seeds. The reductions for sprouts were between 91.1% and 99.8% (1.05-2.72 log(10) CFU/g). An increase in treatment time increased the percentage reduction of E. coli O157:H7. However, germination of the treated seeds reduced from 92% to 49% as amperage to make EO water and soaking time increased. EO water did not cause any visible damage to the sprouts.  相似文献   

13.
Efficacy of chlorine dioxide (ClO2) gas in reducing Escherichia coli O157:H7 and Listeria monocytogenes on strawberries was determined using batch and continuous flow ClO2 gas treatment systems. Effects of continuous ClO2 gas treatment on total aerobic plate count, color, and residual ClO2 and chlorite on strawberries were also evaluated. Strawberries were spot inoculated with 7 to 8 log CFU per strawberry of each pathogen (E. coli O157:H7 and L. monocytogenes), stored for 1 day at 4 degrees C, and treated at 22 degrees C and 90 to 95% relative humidity with 0.2 to 4.0 mg/liter ClO2 gas for 15 or 30 min using a batch treatment system or with 0.6, 1.8, and 3.0 mg/liter for 10 min using a continuous treatment system. Surviving microbial populations were determined using a membrane-transfer plating recovery method. Increased ClO2 gas concentrations resulted in increased log reductions of each pathogen for both the batch and continuous systems. A batch treatment of strawberries with 4 mg/liter ClO2 for 30 min and continuous treatment with 3 mg/liter ClO2 for 10 min achieved greater than a 5-log reduction for both E. coli O157:H7 and L. monocytogenes. After continuous exposure to 3.0 mg/liter ClO2 gas for 10 min followed by 1 week of storage at 4 degrees C, no aerobic microorganisms were detected and the color of the strawberry surface did not change significantly (P > 0.05). Residues of ClO2 and chlorite on strawberries after the treatment were 0.19 +/- 0.33 mg ClO2 per kg and 1.17 +/- 2.02 mg Cl2 per kg, respectively, whereas after 1 week of storage no ClO2 residues were detected and residual chlorite levels were down to 0.07 +/- 0.12 mg Cl2 per kg. These results suggest that ClO2 gas treatment is an effective decontamination technique for improving the safety of strawberries while extending shelf life.  相似文献   

14.
In response to increasingly stringent microbial specifications being imposed by purchasers of frozen blueberries, chlorine dioxide (ClO2) gas generated by a dry chemical sachet was assessed for inactivation of Listeria monocytogenes, Salmonella spp., and Escherichia coli O157:H7 as well as five yeasts and molds known for blueberry spoilage. Fresh blueberry samples (100 g) were separately inoculated with cocktails of L. monocytogenes, Salmonella, E. coli O157:H7 (three strains each), or yeasts and molds (five strains each) to contain approximately 10(6) CFU/g and exposed to ClO2 (4 mg/liter, 0.16 mg/g) for 12 h in a sealed 20-liter container (99.9% relative humidity) at approximately 22 degrees C. After gassing, 25 g of blueberries was added to 225 ml of neutralizing buffer, pulsified for 1 min, and plated using standard procedures to quantify survivors. This treatment yielded reductions of 3.94, 3.62, 4.25, 3.10, and 3.17 log CFU/g for L. monocytogenes, Salmonella, E. coli O157:H7, yeasts, and molds, respectively. Thereafter, 30 lugs of uninoculated blueberries (approximately 9.1 kg per lug) were stacked on 1.2 by 1.2-m pallets (5 lugs per level x six levels), tarped, and exposed to ClO2 (18 mg/liter, 0.13 mg/g) for 12 h. After gassing, significant (P < 0.05) reductions of 2.33, 1.47, 0.52, 1.63, and 0.48 log CFU/g were seen for mesophilic aerobic bacteria, coliforms, E. coli, yeasts, and molds, respectively, compared with non-gassed controls. No significant differences (P > 0.05) in microbial inactivation were seen between lug levels and, with one exception (mesophilic aerobic bacteria), between the bottom and top surface of individual lugs. Based on these findings, ClO2 sachets may provide a simple, economical, and effective means of enhancing the microbial shelf life and safety of blueberries.  相似文献   

15.
This study was conducted to investigate the effect of free chlorine concentrations in wash water on Escherichia coli O157:H7 reduction, survival, and transference during washing of fresh-cut lettuce. The effectiveness of rewashing for inactivation of E. coli O157:H7 on newly cross-contaminated produce previously washed with solutions containing an insufficient amount of chlorine also was assessed. Results indicate that solutions containing a minimum of 0.5 mg/liter free chlorine were effective for inactivating E. coli O157:H7 in suspension to below the detection level. However, the presence of 1 mg/liter free chlorine in the wash solution before washing was insufficient to prevent E. coli O157:H7 survival and transfer during washing because the introduction of cut lettuce to the wash system quickly depleted the free chlorine. Although no E. coli O157:H7 was detected in the wash solution containing 5 mg/liter free chlorine before washing a mix of inoculated and uninoculated lettuce, low numbers of E. coli O157:H7 cells were detected on uninoculated lettuce in four of the seven experimental trials. When the prewash free chlorine concentration was increased to 10 mg/liter or greater, no E. coli O157:H7 transfer was detected. Furthermore, although rewashing newly cross-contaminated lettuce in 50 mg/liter free chlorine for 30 s significantly reduced (P = 0.002) the E. coli O157:H7 populations, it failed to eliminate E. coli O157:H7 on lettuce. This finding suggests that rewashing is not an effective way to correct for process failure, and maintaining a sufficient free chlorine concentration in the wash solution is critical for preventing pathogen cross-contamination.  相似文献   

16.
Efficacy of acidic electrolyzed water ice for pathogen control on lettuce   总被引:4,自引:0,他引:4  
Acidic electrolyzed water (AcEW) was used as frozen AcEW (AcEW-ice) for inactivation of Listeria monocytogenes and Escherichia coli O157:H7 on lettuce. AcEW-ice was prepared from AcEW with 20, 50, 100, and 200 ppm of available chlorine by freezing at -40 degrees C and generated 30, 70, 150, and 240 ppm of chlorine gas (Cl2), respectively. The AcEW-ice was placed into styrene-foam containers with lettuce samples at 20 degrees C for 24 h. Although AcEW-ice generating 30 ppm Cl2 had no effect on L. monocytogenes cell counts, AcEW-ice generating 70 to 240 ppm of Cl2 significantly (P < 0.05) reduced L. monocytogenes by ca. 1.5 log CFU/g. E. coli O157:H7 cell counts were reduced by 1.0 log CFU/g with AcEW-ice generating 30 ppm of Cl2. AcEW-ice generating 70 and 150 ppm of Cl2 reduced E. coli O157:H7 by 2.0 log CFU/g. Further significant reduction of E. coli O157:H7 (2.5 log CFU/g) was demonstrated by treatment with AcEW-ice generating 240 ppm of Cl2. However, treatment with AcEW-ice generating 240 ppm of Cl2 resulted in a physiological disorder resembling leaf burn. AcEW-ice that generated less than 150 ppm of Cl2 had no effect on the surface color of the lettuce. AcEW-ice, regardless of the concentration of the emission of Cl2, had no effect on the ascorbic acid content in the lettuce. The weight ratio of lettuce to AcEW-ice required was determined to be over 1:10. The bactericidal effect of AcEW-ice appeared within the first 2 h. The use of AcEW-ice provides simultaneously for low temperature storage and inactivation of bacteria.  相似文献   

17.
Food safety issues and increases in food borne illnesses have promulgated the development of new sanitation methods to eliminate pathogenic organisms on foods and surfaces in food service areas. Electrolyzed oxidizing water (EO water) shows promise as an environmentally friendly broad spectrum microbial decontamination agent. EO water is generated by the passage of a dilute salt solution ( approximately 1% NaCl) through an electrochemical cell. This electrolytic process converts chloride ions and water molecules into chlorine oxidants (Cl(2), HOCl/ClO(-)). At a near-neutral pH (pH 6.3-6.5), the predominant chemical species is the highly biocidal hypochlorous acid species (HOCl) with the oxidation reduction potential (ORP) of the solution ranging from 800 to 900mV. The biocidal activity of near-neutral EO water was evaluated at 25 degrees C using pure cultures of Escherichia coli, Salmonella typhimurium, Staphylococcus aureus, Listeria monocytogenes, and Enterococcus faecalis. Treatment of these organisms, in pure culture, with EO water at concentrations of 20, 50, 100, and 120ppm total residual chlorine (TRC) and 10min of contact time resulted in 100% inactivation of all five organisms (reduction of 6.1-6.7log(10)CFU/mL). Spray treatment of surfaces in food service areas with EO water containing 278-310ppm TRC (pH 6.38) resulted in a 79-100% reduction of microbial growth. Dip (10min) treatment of spinach at 100 and 120ppm TRC resulted in a 4.0-5.0log(10)CFU/mL reduction of bacterial counts for all organisms tested. Dipping (10min) of lettuce at 100 and 120ppm TRC reduced bacterial counts of E. coli by 0.24-0.25log(10)CFU/mL and reduced all other organisms by 2.43-3.81log(10)CFU/mL.  相似文献   

18.
A series of studies was done for the purpose of developing a proposed standard method to evaluate point-of-use home sanitizers for fresh produce. Preliminary experiments were done to determine the survival of Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes after inoculation onto the surface of ripe tomatoes and drying for up to 24 h at 22 +/- 2 degrees C. Within 2 h, the initial population (6.88 log10 CFU/tomato) of E. coli O157:H7 was reduced by approximately 3 log10, while reductions in similar initial populations of Salmonella and L. monocytogenes were approximately 1 and 0.6 log10 CFU/tomato, respectively, after 40 min and 3 h. A pilot study evaluated treatment with 200 ppm free chlorine and a prototype Fit produce wash (Fit) for their efficacy in killing a five-serotype mixture of Salmonella or L. monocytogenes spot inoculated on tomatoes using the proposed inoculation and recovery procedures. Inoculated tomatoes were sprayed with chlorinated water, Fit, or sterile distilled water (control) and hand rubbed for 30 s. Each tomato was then placed in a plastic bag and rinsed with 200 ml of sterile water by vigorously agitating for 30 s to simulate a procedure consumers might use for sanitizing and rinsing produce in a home setting. Each tomato was transferred to a second bag, and 20 ml of sterile 0.1% peptone was added; tomatoes were rubbed by hand for 40 s. Populations of Salmonella or L. monocytogenes in the rinse water and the 0.1% peptone wash solution were determined. Treatment with 200 ppm chlorine and Fit resulted in > or = 3.07 and > 6.83 log10 reductions, respectively, in Salmonella. Treatment with 200 ppm chlorine and Fit reduced the number of L. monocytogenes by > or = 3.33 and > or = 4.96 log10 CFU/tomato, respectively. The proposed standard method for testing the efficacy of point-of-use produce sanitizers needs to be evaluated for reproducibility of results through a larger scale series of experiments.  相似文献   

19.
The objectives of this study were to examine inactivation kinetics of inoculated Escherichia coli O157:H7, Listeria monocytogenes and Salmonella Poona inoculated onto whole cantaloupe and treated with ClO(2) gas at different concentrations (0.5, 1.0, 1.5, 3.0 and 5.0 mg l(-1)) for different times (0, 2.0, 4.0, 6.0, 8.0 and 10.0 min). The effect of ClO(2) gas on the quality and shelf life of whole cantaloupe was also evaluated during storage at 22 degrees C for 12 days. A 100 microl inoculation of each targeted organism was spotted onto the surface (5 cm(2)) of cantaloupe rind (approximately 8-9 log CFU 5 cm(-2)) separately, air dried (60 min), and then treated with ClO(2) gas at 22 degrees C and 90-95% relative humidity for 10 min. Surviving bacterial populations on cantaloupe surfaces were determined using a membrane transferring method with a non-selective medium followed by a selective medium. The inactivation kinetics of E. coli O157:H7, L. monocytogenes and S. Poona were determined using nonlinear kinetics (Weibull model). A 3 log CFU reduction of E. coli O157:H7, L. monocytogenes and S. Poona were achieved with 5.0 mg l(-1) ClO(2) gas for 5.5, 4.2 and 1.5 min, respectively. A 5l og CFU reduction of S. Poona was achieved with 5.0 and 3.0 mg l(-1) ClO(2) gas for 6 and 8 min, respectively. A 4.6 and 4.3 log reduction was achieved after treatment with 5.0 mg l(-1) ClO(2) gas at 10 min for E. coli O157:H7 and L. monocytogenes, respectively. Treatment with 5.0 mg l(-1) ClO(2) gas significantly (p<0.05) reduced the initial microflora (mesophilic bacteria, psychrotrophic bacteria, and yeasts and molds) on cantaloupe by more than 2 log CFU cm(-2) and kept them significantly (p<0.05) lower than the untreated control during storage at 22 degrees C for 12 days. Treatment with ClO(2) gas did not significantly (p>0.05) affect the color of whole cantaloupe and extended the shelf life to 9 days compared to 3 days for the untreated control, when stored at ambient temperature (22 degrees C).  相似文献   

20.
Outbreaks of Salmonella and Escherichia coli O157:H7 infections associated with alfalfa and other seed sprouts have occurred with increased frequency in recent years. This study was undertaken to determine the efficacy of a liquid prototype produce wash product (Fit), compared with water and chlorinated water, in killing Salmonella and E. coli O157:H7 inoculated onto alfalfa seeds. We investigated the efficacy of treatments as influenced by seeds from two different lots obtained from two seeds suppliers and by two methods of inoculation. The efficacy of treatments was influenced by differences in seed lots and amount of organic material in the inoculum. Significant (alpha = 0.05) reductions in Salmonella populations on seeds treated with 20,000 ppm of chlorine or Fit for 30 min ranged from 2.3 to 2.5 log10 CFU/g and 1.7 to 2.3 log10 CFU/g, respectively. Reductions (alpha = 0.05) in E. coli O157:H7 ranged from 2.0 to 2.1 log10 CFU/g and 1.7 to more than 5.4 log10 CFU/g of seeds treated, respectively, with 20,000 ppm of chlorine or Fit. Compared with treatment with 200 ppm of chlorine, treatment with either 20,000 ppm of chlorine or Fit resulted in significantly higher reductions in populations of Salmonella and E. coli O157:H7. None of the treatments eliminated these pathogens as evidenced by their detection on enrichment of treated seeds. Considering the human health and environmental hazards associated with the use of 20,000 ppm of chlorine, Fit provides an effective alternative to chlorine as a treatment to significantly reduce bacterial pathogens that have been associated with alfalfa seeds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号