首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Abstract The influence of temperature on the emission rate of volatile organic compounds (VOC) from four indoor materials was investigated in a small dynamic test chamber. The materials investigated were two carpets, a PVC flooring and a paint; the temperature range investigated was 23–50°C. The general trend was an increased initial emission rate and an increased decay rate with increasing temperature. The total emitted mass from paint is independent of temperature which means that bake-out is expected to be successful. The total emitted mass of the carpets and the PVC flooring increased with temperature, which suggests an influence of chemical reactions. In these cases, bake-out periods of a few days may be unsuccessful and the exposure of the population may be underestimated when using data from experiments performed at the (lower) standard temperature.  相似文献   

3.
The indoor air quality (IAQ) was measured in newly built Korean apartments before and after occupancy in a survey of 158 residences in 24-apartment complexes nationwide. Factors that might affect pollutant concentration, such as temperature, humidity, housing size, and duration of occupancy, were analyzed in relation to the measured concentrations. Average pollutant levels were consistent with the Ministry of the Environment's recommended standards; however, pollutant levels in some apartments exceeded the current standards. We found that the concentrations of formaldehyde and toluene often exceeded the more stringent guidelines that will soon be enacted. Our results suggest that stronger countermeasures are therefore required to control these two chemicals. The results show that the pollution concentration was generally proportional to temperature and humidity, but that, in some cases, the concentration measurements were inversely proportional to these two factors, and in a few others the relationship between these factors was not clear. Indoor air pollution readings were highest in the 30-pyeong apartments, followed by 10-, and 20-pyeong residences. The pollutant concentrations decreased to about half of their initial levels after one year of occupancy, but the concentration of formaldehyde in indoor air persisted for a longer period. The duration of the apartment's occupancy affected indoor air pollutant concentrations more so than other factors such as temperature, humidity, and apartment size.  相似文献   

4.
Field measurements of 21 volatile organic compounds (VOC) using diffusive samplers, formaldehyde, temperature, and humidity were performed from the time of building completion throughout the following one-year period in two new semi-detached twin apartments. One of these was occupied after six weeks. Headspace analyses from all building materials and products showed 120 different VOC. Formaldehyde concentrations were strongly seasonally dependent in the vacant apartment and increased to above 400 μg/m3 during the warm season. The formaldehyde concentration generally decreased in the occupied apartment but increased again during the fall season. VOC originating from building materials generally showed a decrease in emission, but strong seasonal variations were observed. It was shown that human activity introduces several VOC to the indoor environment. Storage of motorcycle parts in the crawl space of the occupied apartment resulted in migration and an infiltration of benzene and toluene into the apartment above and probably to a delayed peak concentration in the twin vacant apartment. Similarly, large VOC increases in one apartment were reflected by a later increase of the same VOC in the twin apartment. Hexanal increased during the warm season. TVOC, as the sum of 21 VOC, was generally approximately 50 % higher in the occupied apartment during the cold season. The results indicate the difficulties in interpreting long-term measurements. The “flushing period” recommended for this type of building has been estimated to be about 130 days.  相似文献   

5.
A chamber method for the characterization of the complex composition and time dependence of volatile organic compound (VOC) emissions from household products is described and the results obtained for five household products (two liquid floor detergents, one wax, a spray detergent for carpets, and a spray polish for furniture) are reported and compared to headspace measurements. An empirical mathematical model has been used to describe the time dependence of VOC concentrations in the chamber. The model allows characterization of complex emissions and their time dependence with relatively few parameters. Significant differences in the composition of emissions determined in the chamber and in headspace air have been observed and are discussed in terms of polarity and water solubility of the emitted compounds.  相似文献   

6.
A total of 115 Danish dwellings were investigated during the winter season in order to evaluate the indoor environment. The sample was considered representative of Danish dwellings. Measurements of air-exchange rates in the bedrm showed a very low natural venthtion with a median air-exchange rate of 0.28 air changes per hour (ach) (interqmmle range (IQR): 0.12 –0.56).18% of the dwellings had a natural air-exchange below a detectable limit of 0.10 ach and 72% had air-exchanges rates below the requirements in Danish Building Codes of 0.50 ach. The investigations showed a statistically signifiant inverse correlation between air-exchange rates and absolute indoor humidity. Concentrations of formaldehyde and volatile organic compounds were measured in 36 dwellings. The median formaldehyde concentration was 0.037 mg/m3 which is well below the recommended indoor TLV The concentration of VOC in some cases reached a level that may be of importance for persons with sensitive airways. It is concluded that natural ventilation in a great number of Danish dwellings is too low fiom a health point of view and that the requirements in Danish Building codes are insufficient to ensure acceptable air-exchange rates.  相似文献   

7.
Abstract Abstract This paper presents formaldehyde and volatile organic compounds (VOC) concentrations, potential sources and impact factors in 100 homes. The 24‐h average formaldehyde concentration in 37 homes exceeded the good class of the Hong Kong Indoor Air Quality Objectives (HKIAQO), whereas the total VOCs concentration in all homes was lower than the HKIAQO. Compared to other East Asian cities, indoor formaldehyde and styrene in Hong Kong was the highest, reflecting that the homes in Hong Kong were more affected by household products and materials. The formaldehyde concentration in newly built apartments was significantly higher than that in old buildings, whereas no relationship between the concentration and the building age was found for VOCs. There was no difference for formaldehyde and toluene between smoking and non‐smoking homes, suggesting that cigarette smoking was not the major source of these two species. Homes of a couple with a child had higher formaldehyde and acetic acid concentrations, while homes with more than three people had higher concentrations of 1‐butanol, heptane and d‐limonene. When shoes were inside the homes, heptane, acetic acid, nonane and styrene concentrations were statistically higher than that when shoes were out of the homes. Furthermore, higher levels of 1,2,4‐trimethylbenzene, styrene, nonane and heptane were found in gas‐use families rather than in electricity‐use homes.  相似文献   

8.
    
Retail buildings have a potential for both short‐term (customer) and long‐term (occupational) exposure to indoor pollutants. However, little is known about volatile organic compound (VOC) concentrations in the retail sector and influencing factors, such as ventilation, in‐store activities, and store type. We measured VOC concentrations and ventilation rates in 14 retail stores in Texas and Pennsylvania. With the exception of formaldehyde and acetaldehyde, VOCs were present in retail stores at concentrations well below health guidelines. Indoor formaldehyde concentrations ranged from 4.6 ppb to 67 ppb. The two mid‐sized grocery stores in the sample had the highest levels of ethanol and acetaldehyde, with concentrations up to 2.6 ppm and 92 ppb, respectively, possibly due to the preparation of dough and baking activities. Indoor‐to‐outdoor concentration ratios indicated that indoor sources were the main contributors to indoor VOC concentrations for the majority of compounds. There was no strong correlation between ventilation and VOC concentrations across all stores. However, increasing the air exchange rates at two stores led to lower indoor VOC concentrations, suggesting that ventilation can be used to reduce concentrations for some specific stores.  相似文献   

9.
Abstract Volatile organic compounds (VOCs) have been simultaneously measured indoors and outdoors at 50 sparsely occupied telecommunications (Telco) offices, 9 variably occupied data centers and 11 densely occupied administrative (Admin) offices. Comparisons among the three building types, as well as within each of the building types, showed the influence of ventilation and sources. On average, the Telco and Admin facilities were better ventilated than the Data Centers, and the geometric mean of the I/O's for ∑VOC (sum of the concentrations of identified VOCs) at Telco (3.2) and Admin (5.3) facilities were lower than at Data Centers (8.6). Admin Offices had more and stronger sources than Telco Offices; when comparably ventilated facilities were compared, many VOCs had I/O ratios that were significantly larger at the Admin Offices. Furthermore, certain VOCs were detected in Admin but not Telco Offices. The influence of human occupancy on indoor VOCs was gauged by comparing sparsely and densely occupied buildings. Octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), n-dodecane (n-C12) through n-hexadecane (n-C16), limonene, and, to a lesser extent, tetrachloroethylene were all present in higher concentrations when there were more occupants (per unit area). Within this set of compounds, D5 was the best marker of occupant density.  相似文献   

10.
Mendell MJ 《Indoor air》2007,17(4):259-277
Most research into effects of residential exposures on respiratory health has focused on allergens, moisture/mold, endotoxin, or combustion products. A growing body of research from outside the US; however, has associated chemical emissions from common indoor materials with risk of asthma, allergies, and pulmonary infections. This review summarizes 21 studies in the epidemiologic literature on associations between indoor residential chemical emissions, or emission-related materials or activities, and respiratory health or allergy in infants or children. Associations, some strong, were reported between many risk factors and respiratory or allergic effects. Risk factors identified most frequently included formaldehyde or particleboard, phthalates or plastic materials, and recent painting. Findings for other risk factors, such as aromatic and aliphatic chemical compounds, were limited but suggestive. Elevated risks were also reported for renovation and cleaning activities, new furniture, and carpets or textile wallpaper. Reviewed studies were entirely observational, limited in size, and variable in quality, and specific risk factors identified may only be indicators for correlated, truly causal exposures. Nevertheless, overall evidence suggests a new class of residential risk factors for adverse respiratory effects, ubiquitous in modern residences, and distinct from those currently recognized. It is important to confirm and quantify any risks, to motivate and guide necessary preventive actions. PRACTICAL IMPLICATIONS: Composite wood materials that emit formaldehyde, flexible plastics that emit plasticizers, and new paint have all been associated with increased risks of respiratory and allergic health effects in children. Although causal links have not been documented, and other correlated indoor-related exposures may ultimately be implicated, these findings nevertheless point to a new class of little recognized indoor risk factors for allergic and respiratory disease, distinct from the current set of indoor risk factors. The available evidence thus raises initial questions about many common residential practices: for instance, using pressed wood furnishings in children's bedrooms, repainting infant nurseries, and encasing mattresses and pillows with vinyl for asthmatic children. The findings summarized here suggest a need for substantially increased research to replicate these findings, identify causal factors, and validate preventive strategies.  相似文献   

11.
Indoor air quality of new apartment buildings, which is known to cause Sick Housing Syndrome, has become a major concern among apartment residents as well as construction companies in Korea. Recently, the Indoor Air Quality Management Act, a regulation that limits concentration levels of formaldehyde and five volatile organic compounds in new apartment buildings, has been implemented. In this study, the effects of ventilation and decomposing agents were investigated and compared, which could be used at the pre-occupancy stage as solutions to high VOCs concentration levels in new apartment buildings. Six housing units were investigated under different conditions to assess the extent of the improvement in indoor air quality. The results demonstrate that ventilation is an effective way to control indoor air pollution caused by VOCs emissions, and the effect of decomposing agents on improving indoor air quality depends on the types of VOCs.  相似文献   

12.
A study was performed to characterize the concentration of dozens of volatile organic compounds (VOCs) at 10 locations within a single large building and track these concentrations over a 2-year period. The study was performed at a shopping center (strip mall) in New Jersey. A total of 130 indoor air samples were collected from 10 retail stores within the shopping center and analyzed for 60 VOCs by US EPA Method TO-15. Indoor concentrations of up to 55,100 microg/m(3) were measured for individual VOCs. The indoor/outdoor ratio (I/O) was as high as 1500 for acetone and exceeded 100 at times for various compounds, indicating that significant indoor air sources were present. A large degree of spatial variability was observed between stores within the building, with concentrations varying by three to four orders of magnitude for some compounds. The spatial variability was dependent on the proximity of the sampling locations to the indoor sources. A large degree of temporal variability also was observed for compounds emitted from indoor sources, but the temporal variability generally did not exceed two standard deviations (sigma). For compounds not emitted from indoor sources at significant rates, both the spatial and temporal variability tended to range within an order of magnitude at each location. PRACTICAL IMPLICATIONS: Many cross-sectional studies have been published where the levels of volatile organic compounds (VOCs) were measured in indoor air at one or two locations for houses or offices. This study provides longitudinal data for a commercial retail building and also addresses spatial variability within the building. The data suggest that spatial and temporal variability are important considerations for compounds emitted from indoor sources. Elevated concentrations were found in retail spaces with no apparent emission sources due to their proximity to other retail spaces with emission sources.  相似文献   

13.
Personal exposure to total volatile organic compounds (TVOCs), benzene and toluene of 100 Milan office workers was assessed through personal air monitoring at home, in the office, and during commuting. Biological monitoring was performed by measuring blood benzene and toluene concentrations together with urinary trans-trans-muconic acid (t,t-MA) and cotinine at the end of the monitoring period. The geometric means of the total 24-h personal exposure were 514 micrograms/m3 for TVOCs, 21.2 micrograms/m3 for benzene and 35.2 micrograms/m3 for toluene. Daily exposure to the volatile organic compounds was almost totally determined by indoor exposure at home and in the office, with a minor contribution in the transport means. An important factor determining exposure to benzene was found to be tobacco smoke, both for active smokers and for non-smokers exposed to environmental tobacco smoke (ETS). All the mean levels of the biological indicators were significantly higher in active smokers than in non-smoking subjects non-exposed to ETS; urine cotinine and t,t-MA levels were also significantly higher in non-smokers exposed to ETS than in non-smokers non-exposed to ETS.  相似文献   

14.
Personal exposures of 100 adult non-smokers living in the UK, as well as home and workplace microenvironment concentrations of 15 volatile organic compounds were investigated. The strength of the association between personal exposure and indoor home and workplace concentrations as well as with central site ambient air concentrations in medium to low pollution areas was assessed. Home microenvironment concentrations were strongly associated with personal exposures indicating that the home is the driving factor determining personal exposures to VOCs, explaining between 11 and 75% of the total variability. Workplace and central site ambient concentrations were less correlated with the corresponding personal concentrations, explaining up to 11-22% of the variability only at the low exposure end of the concentration range (e.g. benzene concentrations < 2.5 μg m−3). One of the reasons for the discrepancies between personal exposures and central site data was that the latter does not account for exposure due to personal activities (e.g. commuting, painting). A moderate effect of season on the strength of the association between personal exposure and ambient concentrations was found. This needs to be taken into account when using fixed site measurements to infer exposures.  相似文献   

15.
To conserve energy, office buildings with air-conditioning systems in Thailand are operated with a tight thermal envelope. This leads to low fresh-air ventilation rates and is thought to be partly responsible for the sick building syndrome symptoms reported by occupants. The objectives of this study are to measure concentrations and to determine sources of 13 volatile organic compounds (VOCs) in office buildings with air-conditioning systems in the business area of Bangkok. Indoor and outdoor air samples from 17 buildings were collected on Tenax-TA sorbent tubes and analyzed for individual VOCs by thermal desorption-gas chromatography/mass spectrometry (TD–GC/MS). Building ventilation was measured with a constant injection technique using hexafluorobenzene as a tracer gas. The results show that the VOC concentrations varied significantly among the studied buildings. The two most dominant VOCs were toluene and limonene with average concentrations of 110 and 60.5 μg m−3, respectively. A Wilcoxon sum rank test indicated that the indoor concentrations of aromatic compounds and limonene were statistically higher than outdoor concentrations at the 0.05 level, while the indoor concentrations of chlorinated compounds were not. Indoor emission factors of toluene and limonene were found to be highest with the average values of 80.9 and 18.9 μg m−2 h−1, respectively. Principal component analysis was applied to the emission factors of 13 VOCs, producing three components based on source similarities. Furthermore, a questionnaire survey investigation and field measurements of building air exchange pointed to indoor air complaints related to inadequate ventilation.  相似文献   

16.
Conservation of ancient buildings is a major issue for modern societies, both from economical and cultural viewpoints. Information about the ancient built heritage is vital to plan adequate remedial measures. Taking a historic centre in Portugal as a case study, this paper presents an extensive survey of building typology and materials, damage in the building envelope, indoor survey of damage, and measurements in indoor air temperature and relative humidity. Water-related problems can be confirmed as the single most important defect combined with inadequate sun exposure, ventilation and heating, and excessive moisture indoor production. Extremely low temperatures, high humidity and presence of mould therefore, compromise the indoor quality of life of the inhabitants; and make urgent repair at many levels necessary.  相似文献   

17.
BTEX is the commonly used term for a group of toxic compounds (benzene, toluene, ethyl benzene, ortho-xylene and meta- and para-xylene), some of which, most notably benzene, are known carcinogens. The aim of this study is to measure the BTEX levels both inside and outside the homes of 352 one-year old children from the Valencia cohort of the INMA study (Spain) and to analyze the determinants of these levels. Passive samplers were used to measure BTEX levels during a 15 day period and a questionnaire was administered to gather information on potentially associated factors (sociodemographics, residential conditions, and lifestyle). The average concentrations of benzene, toluene, ethyl benzene, ortho-xylene, and meta- and para-xylene were 0.9, 3.6, 0.6, 0.6, and 1.0 μg/m3, respectively. On average, the indoor levels of all the compounds were approximately 2.5 times higher than those observed outdoors. Factors associated with higher BTEX concentrations inside the home were being the child of a mother of non-Spanish origin, living in a house that had been painted within the last year, living in an apartment, and not having air conditioning. Higher outdoor concentrations of BTEX depend on the residence being situated in a more urban zone, being located within the city limits, having living in a building with more than one story, residing in an area with a greater frequency of traffic, and the season of the year in which the sample was taken. The data thus obtained provide helpful information not only for implementing measures to reduce exposure to these pollutants, but also for evaluating the relation between such exposure and possible health risks for the children in the cohort.  相似文献   

18.
This paper characterizes and compares emissions during heating of different dust samples relevant to the indoor environment. Characterization includes emission of volatile organic compounds when dust samples were heated to 150 and 250 degrees C (gas chromatograph-mass spectrometer), weight loss during heating to 450 degrees C (thermogravimetric analysis), and the number of particles emitted during heating towards 200 degrees C (condensation nucleus counting). Element analyses were performed for non-heated dust (inductively coupled plasma discharge instrument). Emissions of volatile organic compounds from heated dust from different sources were surprisingly similar. However, the temperature at which the emission of volatiles started varied with the dust source. For most of the samples studied, the emissions were considerable already at 150 degrees C, and increased in number of peaks and peak area at 250 degrees C. Particle emissions started around 70 degrees C regardless of the dust source. Particle emissions seemed to be affected by the content of organic material.  相似文献   

19.
Monitoring of human reactions to the emission of formaldehyde and volatile organic compounds (VOC) from four commonly used building materials was carried out. The building materials were: a painted gypsum board, a rubber floor, a nylon carpet, and a particle board with an acid-curing paint. The exposures were performed in climate chambers. The air quality was quantified on the decipol scale by a trained panel, measurements of formaldehyde and VOC being performed simultaneously. The irritating potency of the materials was measured by a mouse bioassay. The VOC measurements showed several malodorants and irritants. Some abundant VOC identified in the head-space analyses were absent in the climate chamber air. The rubber floor and the nylon carpet exhibited a marked increase in decipols compatible with a number of odorous VOC identified in the air. A high formaldehyde concentration (minimum 743μg/m3) was measured for the particle board coated with an acid-curing paint. This was not reflected by a corresponding relatively high decipol value but a long-lasting irritating potency was observed in the mouse bioassay. TVOC sampled on Tenax and expressed in mass per volume as well as in molar concentration, and decipol evaluation both have limitations and should be used with caution as indicators of (perceived) indoor air quality. Eye irritation expressed by means of the eye index reflecting the tear film quality index (comprised of break-up time, foam formation, thickness of the precorneal lipid layer of the tear film, and epithelial damage) was found to be insensitive to formaldehyde and a VOC mixture but sensitive to TVOC concentrations of 1–2 mg/m3. Lipophilic VOC may be the cause of reduced tear film quality by destabilization of the lipid multilayer of the tear film.  相似文献   

20.
Zhao D  Little JC  Hodgson AT 《Indoor air》2002,12(3):184-190
A physically based diffusion model is used to evaluate the sink effect of diffusion-controlled indoor materials and to predict the transient contaminant concentration in indoor air in response to several time-varying contaminant sources. For simplicity, it is assumed the predominant indoor material is a homogeneous slab, initially free of contaminant, and the air within the room is well mixed. The model enables transient volatile organic compound (VOC) concentrations to be predicted based on the material/air partition coefficient (K) and the material-phase diffusion coefficient (D) of the sink. Model predictions are made for three scenarios, each mimicking a realistic situation in a building. Styrene, phenol, and naphthalene are used as representative VOCs. A styrene butadiene rubber (SBR) backed carpet, vinyl flooring (VF), and a polyurethane foam (PUF) carpet cushion are considered as typical indoor sinks. In scenarios involving a sinusoidal VOC input and a double exponential decaying input, the model predicts the sink has a modest impact for SBR/styrene, but the effect increases for VF/phenol and PUF/naphthalene. In contrast, for an episodic chemical spill, SBR is predicted to reduce the peak styrene concentration considerably. A parametric study reveals for systems involving a large equilibrium constant (K), the kinetic constant (D) will govern the shape of the resulting gasphase concentration profile. On the other hand, for systems with a relaxed mass transfer resistance, K will dominate the profile.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号