首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
There seems to be a discrepancy between current Indoor Air Quality standards and end-users wishes and demands. Indoor air quality can be approached from three points of view: the human, the indoor air of the space and the sources contributing to indoor air pollution. Standards currently in use mainly address the indoor air of the space. “Other or additional” recommendations and guidelines are required to improve indoor air quality. Even though we do not fully understand the mechanisms behind the physical, chemical, physiological and psychological processes, it is still possible to identify the different ways to be taken regulatory, politically–socially (awareness), technically (process and product) and scientifically. Besides the fact that there is an urgent need to involve medicine and neuro-psychology in research to investigate the mechanisms behind dose-response, health effects and interactions between and with the other factors and parameters of the indoor environment and the human body and mind, a holistic approach is required including the sources, the air and last but not least the human beings (occupants) themselves. This paper mainly focuses on the European situation.  相似文献   

2.
The effects of faults on an air handling unit (AHU) are often poorly evaluated (assuming indoor air quality (IAQ) problems), and under-estimated in consumption balances. Based on an experimental site, this paper presents a quantitative study of some different faults that can appear on AHUs.  相似文献   

3.
Abstract Sick building syndrome (SBS) with an unknown etiology has led researchers to focus on the role of psychosocial factors in the work environment as well as on individual characteristics in SBS. Recent research has suggested that psychosocial factors are quite strongly associated with SBS. The associations have been confirmed in buildings that were beforehand considered to be problem cases, and also in buildings whose condition was not known in advance. However, SBS symptoms could not be attributed to psychosocial factors alone. Most of the previous studies have supported the conclusion that SBS most likely is of multifactorial origin related to chemical, physical, biological and psychosocial factors that interact or coincide with one another. Unfortunately, for the time being, it is not possible to characterize adequately the relationship between the various risk factors and the possible mechanisms of SBS. There is an urgent need for more empirical research, especially follow-up studies and interventions, for development of the methodology and for new theory-building in order to better understand the relations between environmental factors, personal factors and the symptoms of SBS. In this literature review, SBS is viewed from an occupational stress perspective.  相似文献   

4.
Although negative air ionizer is commonly used for indoor air cleaning, few studies examine the concentration gradient of negative air ion (NAI) in indoor environments. This study investigated the concentration gradient of NAI at various relative humidities and distances form the source in indoor air. The NAI was generated by single-electrode negative electric discharge; the discharge was kept at dark discharge and 30.0 kV. The NAI concentrations were measured at various distances (10-900 cm) from the discharge electrode in order to identify the distribution of NAI in an indoor environment. The profile of NAI concentration was monitored at different relative humidities (38.1-73.6% RH) and room temperatures (25.2+/-1.4 degrees C). Experimental results indicate that the influence of relative humidity on the concentration gradient of NAI was complicated. There were four trends for the relationship between NAI concentration and relative humidity at different distances from the discharge electrode. The changes of NAI concentration with an increase in relative humidity at different distances were quite steady (10-30 cm), strongly declining (70-360 cm), approaching stability (420-450 cm) and moderately increasing (560-900 cm). Additionally, the regression analysis of NAI concentrations and distances from the discharge electrode indicated a logarithmic linear (log-linear) relationship; the distance of log-linear tendency (lambda) decreased with an increase in relative humidity such that the log-linear distance of 38.1% RH was 2.9 times that of 73.6% RH. Moreover, an empirical curve fit based on this study for the concentration gradient of NAI generated by negative electric discharge in indoor air was developed for estimating the NAI concentration at different relative humidities and distances from the source of electric discharge.  相似文献   

5.
Based on analysis of uncertainty, this paper presents grey system theory to handle the “grey” characteristic of IAQ. Grey comprehensive analysis of indoor air quality reveals that we should pay more attention to the air purification and humidity control in the design and maintenance of HVAC. In order to represent grey characteristic of IAQ system, the educed grey IAQ models can identify the variation intervals of key IAQ model parameters that are lack of directly measurable messages in practical situations. Furthermore, grey assessment is an effective multifactor comprehensive assessment method that can express the integrative influence of contamination indexes on indoor air quality. We can determine the IAQ grade and make comparison according to the grey incidence matrix R.  相似文献   

6.
An alternative method of maintaining indoor air quality may be through the biofiltration of air recirculating within the structure rather than the traditional approach of ventilation. This approach is currently being investigated. Prior to its acceptance for dealing with volatile organic compounds (VOCs) and CO2, efforts were made to determine whether the incorporation of this amount of biomass into the indoor space can have an (negative) impact on indoor air quality. A relatively large ecologically complex biofilter composed of a ca. 10 m2 bioscrubber, 30 m2 of plantings and a 3,500 litre aquarium were established in a 160 m2 'airtight' room in a recently constructed office building in downtown Toronto. This space maintained ca. 0.2 air changes per hour (ACH) compared to the 15 to 20 ACH (with a 30% refresh rate) of other spaces in the same building. Air quality parameters of concern were total VOCs (TVOCs), formaldehyde and aerial spore counts. TVOC and formaldehyde levels in the biofilter room were the same or significantly less than other spaces in the building despite a much slower refresh rate. Aerial spore levels were slightly higher than other indoor spaces but were well within reported values for 'healthy' indoor spaces. Levels appeared to be dependent on horticultural management practices within the space. Most genera of fungal spores present were common indoors and the other genera were associated with living or dead plant material or soil. From these results, the incorporation of a large amount of biomass associated with indoor biofilters does not in itself lower indoor air quality.  相似文献   

7.
8.
Mold specific quantitative PCR (MSQPCR) was used to measure the concentrations of the 36 mold species in indoor and outdoor air samples that were taken simultaneously for 48 h in and around 17 homes in Cincinnati, Ohio. The total spore concentrations of 353 per m(3) of indoor air and 827 per m(3) of outdoor air samples were significantly different (por=0.5). These results suggest that interpretation of the meaning of short-term (<48 h) mold measurements in indoor and outdoor air samples must be made with caution.  相似文献   

9.
An empty, unoccupied basement room in Melton Constable Hall, Norfolk (England), was chosen as a case study to determine whether pentachlorophenol (PCP) treatment of masonry could significantly elevate PCP concentrations in indoor air, thus posing a potential health hazard. This particular room was chosen because it contained a vast quantity of crystalline PCP on the surface of a previously treated wall, and, being rarely used, was less likely to be subject to any external sources of PCP contamination. Analysis of dust debris, airborne particulates, passively deposited suspended particulates and volatile PCP emissions from the contaminated surface showed no evidence that inhalation was a probable route of PCP exposure.  相似文献   

10.
Poor indoor air quality (IAQ) in schools is related to increased symptom reporting in students. We investigated whether parental worry about school IAQ influences this association. Data came from survey collected from five Finnish primary schools with observed IAQ problems and five control schools. Parents (n = 1868) of primary school students reported worry about IAQ in schools and symptoms of their children. Associations between observed IAQ problems, worry, and five symptom scores (ie, respiratory, lower respiratory, eye, skin, and general symptoms) were analyzed using multivariate logistic regression and mediation analysis. Parents were on average more worried in schools with observed IAQ problems. Observed IAQ problems were strongly associated with increased worry and all symptoms under study (unadjusted ORs ranged between 1.48 [95% CI 1.48‐2.16] and 2.70 [95% CI 1.52‐5.17]). Parental worry was associated with all symptoms (unadjusted ORs ranged between 2.49 [95% CI 1.75‐3.60] and 4.92 [95% CI 2.77‐9.40]). Mediation analyses suggested that parental worry might partially explain the association between observed IAQ problems and symptom reporting (proportion mediated ranged between 67% and 84% for the different symptoms). However, prospective studies are needed to assess causal relationships between observed IAQ problems, worry, and symptom reporting in schools.  相似文献   

11.
Unlike commercial premises, the indoor air quality of residences is more dynamic, uncontrolled, and prone to human behavioral changes. In consequence, measuring the health benefit gains derived from improving indoor air quality in residences is more complicated. To overcome this, a human thermal comfort model was first integrated with indoor microenvironment models, and subsequently linked with appropriate concentration-response and economic data for estimating the economic benefit gains derived from improving indoor air quality in residences for an adult and an elderly person. In this study, the development of the model is illustrated by using a typical residential apartment locating at the worst air quality neighborhood in Hong Kong and the daily weather profiles between 2002 and 2006. Three types of personal intervention measures were examined in the study: (i) using air cleaner in residence, (ii) changing time spent in residence, and (iii) relocating to a better air quality neighborhood. Our results revealed that employing air cleaners with windows closed in residence throughout the entire year was the most beneficial measure as it could provide the greatest annual health benefit gains. It would give a maximum of HK$2072 in 5-year cumulative benefit gain for an adult and HK$1700 for an elderly person. Employing air cleaners with windows closed in only cool season (October through March) could give the highest marginal return per dollar spent. The benefit gains would become smaller when windows were opened to a greater extent. By contrast, relocating to a better air quality neighborhood and changing the time spent in residence did not appeal to be beneficial intervention measures.  相似文献   

12.
The uncertainties of professional choice of ‘representative’ sampling locations for general indoor air quality (IAQ) assessment are reported from the perspective of probable errors deviated from the sample-spatial average pollutant concentration of an indoor environment. In this study, associations between the professional choices of the sampling locations and attributes of the assessors were examined to quantify the uncertainties of the IAQ assessment results for a typical air-conditioned office in Hong Kong. In particular, a long-term (one-year) measurement result of the spatial indoor carbon dioxide (CO2) concentrations in this office was used as a basis to investigate the probable errors due to the choices of sampling locations. Comparing with the random choices, the assessment accuracy with the expert choices would be significantly improved for coarse sampling point densities at certain engineering acceptable error limits. It was reported that the location choices and assessment accuracy would be significantly influenced by the academic background of the assessors. An assessor group with higher academic level would make a choice leaning towards more accurate assessment results. To avoid an inappropriate level of reliance on the assessment results, uncertainties must be quantified for IAQ assessment. This study provided a template for further investigations into the uncertainties of IAQ assessment results involving professional choice of ‘representative’ sampling locations and the results might be a useful reference for assessing indoor environment elsewhere.  相似文献   

13.
Many new biological and chemical sensors have been or are continuously being developed for infrastructure and environmental protection, e.g., for protecting the quality of water and indoor and outdoor air. However, there is a lack of fundamental system-level research leading to the development of sensor networks that both maximize protection and minimize the system cost for indoor air protection. Four key parameters are usually used to evaluate sensor performance: sensor sensitivity, probability of correct detection, false positive rate, and response time. The optimal design of a sensor system is affected by the above sensor performance parameters. This paper describes a preliminary study to: (1) identify simplified simulation and optimization strategies that can be used for sensor system design; (2) examine the relationships between sensor location, sensitivity, and quantity, and (3) use both detection time and total occupant exposure as optimization objective functions for sensor system design. Common building attack scenarios, using a typical chemical and biological warfare (CBW) agent, are simulated for a small commercial building. Genetic algorithm (GA) is then applied to optimize the sensor sensitivity, location, and quantity, thus achieving the best system behavior while also reducing the total system cost. Assuming that each attack scenario has the same probability for occurrence, optimal system designs that account for the simulated possible attack scenarios are obtained.  相似文献   

14.
余志强 《山西建筑》2011,37(17):199-200
参照美国ASHRAE标准62—1999,对影响室内空气品质的因素进行了分析,如室内的污染源、受污染的室外空气、不足的新风量、气流组织的不当、空调系统运行管理维护的不当等等,对这些影响因素的深入分析是避免病态建筑、实现健康建筑的基础。  相似文献   

15.
In order to compare patterns of indoor air perception, including perceptions of temperature, air movement, indoor air quality (IAQ), mental concentration, and comfort, 33 subjects either with persistent allergic rhinitis or controls were exposed to different temperatures and constant relative humidity in an experimental office environment. Results were obtained by means of a self-administered visual analogue scale, analyzed using mean score comparisons and principal component analysis. At 14 degrees C, the rhinitis group reported higher scores for sensations of air dryness than controls. At 18 degrees C, in the rhinitis group, there was a correlation between dry, stagnant air, and difficult mental concentration. This group also correlated heat, dry air, and poor IAQ, in contrast to the control group, which correlated comfort, easy mental concentration, and freshness. At 22 degrees C, the rhinitis group correlated heat, dryness, stagnant air, and overall discomfort. This group also correlated non-dry air, freshness, and comfort, whereas the control group correlated heat, humidity, good indoor air, freshness, and comfort. This study suggests that the rhinitis group perceives indoor temperatures of 14 degrees C as dryer than controls do, and that at 18 and 22 degrees C this group positively correlates different adverse perceptions of IAQ. By means of a self-administered questionnaire in an experimental condition, the present study compares subjective patterns of indoor air perception from individuals with respiratory allergy (allergic rhinitis) to control individuals. It reports different patterns of perception of indoor air quality (IAQ) between the two groups, suggesting that allergic individuals could have different IAQ perception.  相似文献   

16.
Qian Z  He Q  Kong L  Xu F  Wei F  Chapman RS  Chen W  Edwards RD  Bascom R 《Indoor air》2007,17(2):135-142
Diverse indoor combustion sources contribute to the indoor air environment. To evaluate the effect of these sources on human respiratory health, we examined associations between respiratory conditions and household factors in the 2360 children's fathers (mean = 38.4 years old) and associations between lung function and household factors in 463 primary school children (mean = 8.3 years old) from Wuhan, China. Factor analysis developed new uncorrelated 'factor' variables. Unconditional logistic regression models or linear regression models, controlling for important covariates, estimated the respiratory health effects. Coal smoke derived from home heating ('heating coal smoke') was associated with high adult reporting of persistent cough, persistent phlegm, and wheeze. Cooking coal smoke was associated with physician-diagnosed adult asthma and decreased forced vital capacity (FVC), and forced expiratory volume at 1 s (FEV(1)) in children. The presence of any home cigarette smoker was associated with more reports of persistent cough, persistent phlegm, cough with phlegm, and bronchitis. Our study suggests that in Wuhan, there may be independent respiratory health effects of different indoor combustion sources and their exposure factors for these study populations. PRACTICAL IMPLICATIONS: We conclude that multiple indoor air pollution sources could have adverse respiratory health effects on both children and middle-aged men in the city of Wuhan, China. These results may have implications for the Wuhan local government, the Chinese government, or other related organizations in efforts on protecting public health through regulation of indoor air pollution from indoor combustion sources.  相似文献   

17.
Yang W  Lee K  Chung M 《Indoor air》2004,14(2):105-111
Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 air change per hour (ACH) in Brisbane, assuming a residential NO2 deposition constant of 1.05/h, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94/h. Source strengths of NO2 were 15.8 +/- 18.2 and 44.7 +/- 38.1 microg/m3/h in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.  相似文献   

18.
Indoor air quality (IAQ) on ships is important for the passengers’ comfort and the crew’s work efficiency, despite ships not being as common as vehicles and airplanes. The builders and operators need to be aware of the importance and present status of IAQ, but sufficient data and information are not available. In this study, we measured the pollutant concentrations on two different kinds of newly launched ships: a passenger ship and a chemical cargo ship. Although higher than in the passenger ship, the concentrations of most volatile organic compounds (VOCs) and formaldehyde in the cargo ship were lower than the recommended standards and acceptable with a few exceptions. The high CO and CO2 concentrations in the kitchen, engine room, and engine control room were generally attributed to combustion sources. Overall, the IAQ of the cargo ship was worse than that of the passenger ship, and the concentrations of some pollutants surpassed the international criteria. For the passenger ship, the variation of IAQ was also investigated after 17 months. The observed data showed some differences in concentration variation according to the types of pollutants. To improve IAQ on ships, more data need to be collected and minimum requirements suggested.  相似文献   

19.
Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building‐related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools’ observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools’ psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school‐related stress, poor teacher–student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = ?0.43) and poor teacher–student relationship (standardized β = ?0.22) were significant predictors of poor subjective IAQ. In addition, school‐related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = ?0.44).  相似文献   

20.
The indoor air quality of 27 primary schools located in the city centre and suburbs of Antwerp, Belgium, was assessed. The primary aim was to obtain correlations between the various pollutant levels. Indoor:outdoor ratios and the building and classroom characteristics of each school were investigated. This paper presents results on indoor and local outdoor PM2.5 mass concentrations, its elemental composition in terms of K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Pb, Al, Si, S, and Cl, and its black smoke content. In addition, indoor and local outdoor levels of the gases NO2, SO2, O3, and BTEX (benzene, toluene, ethyl benzene, and xylene isomers) were determined. Black smoke, NO2, SO2 and O3, occurred at indoor:outdoor ratios below unity, indicating their significant outdoor sources. No linear correlation was established between indoor and outdoor levels for PM2.5 mass concentrations and BTEX; their indoor:outdoor ratios exceeded unity except for benzene. Classroom PM2.5 occurred with a different elemental composition than local outdoor PM2.5. The re-suspension of dust because of room occupation is probably the main contributor for the I/O ratios higher than 1 reported for elements typically constituting dust particles. Finally, increased benzene concentrations were reported for classrooms located at the lower levels. PRACTICAL IMPLICATIONS: The elevated indoor PM2.5, and BTEX concentrations in primary school classrooms, exceeding the ambient concentrations, raise concerns about possible adverse health effects on susceptible children. This is aggravated by the presence of carpets and in the case of classrooms at lower levels. Analysis of PM2.5's elemental composition indicated a considerable contribution of soil dust to indoor PM2.5 mass. In order to set adequate threshold values and guidelines, detailed information on the health impact of specific PM2.5 composites is needed. The results suggest that local outdoor air concentrations measurements do not provide an accurate estimation of children's personal exposures to the identified air pollutants inside classrooms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号