首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
In these advanced adsorption cycles vapour is internally recovered between the two adsorbers, in which temperature is either uniform or non-uniform. In the first case, the cycles use the heat recovery process (double effect cycles), in the second case they use the heat regeneration process (thermal wave cycles). The full analysis (first law and second law) of vapour recovery is developed for either type of cycle. Different possible presentations in the entropic diagram of the cycles with heat recovery and those with heat regeneration are discussed. The thermodynamic differences between the two types of cycle can then clearly be highlighted. In addition, an evaluation of the current state of art of these two technologies is briefly presented.  相似文献   

2.
The objective of this study is to propose and evaluate advanced absorption cycles for the coefficient of performance (COP) improvement and temperature lift enhancement applications. The characteristics of each cycle are assessed from the viewpoints of the ideal cycle COP and its applications. The advanced cycles for the COP improvement are categorized according to their heat recovery method: condensation heat recovery, absorption heat recovery, and condensation/absorption heat recovery. In H2O–LiBr systems, the number of effects and the number of stages can be improved by adding a third or a fourth component to the solution pairs. The performance of NH3–H2O systems can be improved by internal heat recovery due to their thermal characteristics such as temperature gliding. NH3–H2O cycles can be combined with adsorption cycles and power generation cycles for waste heat utilization, performance improvement, panel heating and low temperature applications. The H2O–LiBr cycle is better from the high COP viewpoints for the evaporation temperature over 0°C while the NH3–H2O cycle is better from the viewpoint of low temperature applications. This study suggests that the cycle performance would be significantly improved by combining the advanced H2O–LiBr and NH3–H2O cycles.  相似文献   

3.
In this paper the results of performance calculations of two vapour compression heat pump cycles, one with a single-stage solution circuit and one with a two-stage solution circuit, are presented. As a working fluid combination R22-DEGDME was selected out of a number of candidates in order to employ a safe and non-toxic mixture. It was found that both cycles show a significant increase in coefficient of performance (COP) (up to 50% for the two-stage cycle) compared to R22. The two-stage cycle shows a pressure ratio which is only 45% that for pure R22, resulting in increased mass flow rate but reduced capacity.  相似文献   

4.
This paper presents an analysis of the influence of the distillation column components size on the vapour enrichment and system performance in small power NH3–H2O absorption machines with partial condensation. It is known that ammonia enrichment is required in this type of systems; otherwise water accumulates in the evaporator and strongly deteriorates the system performance and efficiency. The distillation column analysed consists of a stripping adiabatic section below the column feed point and an adiabatic rectifying packed section over it. The partial condensation of the vapour is produced at the top of the column by means of a heat integrated rectifier with the strong solution as coolant and a water cooled rectifier. Differential mathematical models based on mass and energy balances and heat and mass transfer equations have been developed for each one of the column sections and rectifiers, which allow defining their real dimensions. Results are shown for a given practical application. Specific geometric dimensions of the column components are considered. Different distillation column configurations are analysed by selecting and discarding the use of the possible components of the column and by changing their dimensions. The analysis and comparison of the different column arrangements has been based on the system COP and on the column dimensions.  相似文献   

5.
A comparison of thermodynamic performances of sorption systems (liquid absorption, adsorption, ammonia salts and metal hydrides) is carried out for typical applications (deep-freezing, ice making, air-conditioning and heat pumping) with either air-cooled or water-cooled heat sink. The results are given in terms of cooling coefficient of performance (COP) (heating COP or coefficient of amplification (COA) for the heat pump), cooling (heating) power versus reactor volume or weight and thermodynamic efficiency. LiBr–water systems show the best results for air-conditioning except when small units are required (metal hydride systems lead to more compact units). Other systems, however, show better results for other applications (chemical reaction with ammonia salts for deep-freezing, adsorption for heat pumping).  相似文献   

6.
Simulation analyses for a vapour compression heat pump cycle using nonazeotropic refrigerant mixtures (NARMs) of R22 and R114 are conducted under the condition that the heat pump thermal output and the flow rate and inlet temperatures of the heat sink and source water are given. The heat transfer coefficients of the condensation and evaporation are calculated with empirical correlations proposed by the authors. The validity of the evaluation method and the correlations is demonstrated by comparison with experimental data. The relations between the coefficient of performance (COP) and composition are shown under two conditions: (1) the constant heat transfer length of the condenser and evaporator; and (2) the constant temperature of refrigerant at the heat exchanger inlet. The COP of the NARMs is higher than that of pure refrigerant when the heat transfer lengths of the condenser and evaporator are sufficiently long.  相似文献   

7.
The theoretical performances of some 250 potential work fluids in vapour compression heat pumps condensing at 150°C and evaporating at 100°C have been predicted, using expression for coefficient of performance (COP) and minimum superheat that involve only easily accessible physical properties. Expected correlations were found between COP and critical temperature, between specific compressor displacement and normal boiling point, Tbp, and between condensing pressure and Tbp. Correlations were also found between minimum superheat and both molecular weight and critical pressure. From these correlations, the desirable basic properties of a high temperature heat pump fluid are deduced. The principle of corresponding states is invoked to explain the connection between minimum superheat and critical pressure, and hence the reason why perfluorinated compounds tend to make poor work fluids.  相似文献   

8.
Whenever the fractional temperature lift ΔT/Tc of a heat pump is 0.15, simple cycles with one-stage throttling exhibit unsatisfactory energy performance. The adoption of multi-stage throttling, both in non-regenerative and regenerative cycles, is the most direct way of improving the cycle coefficient of performance (COP). The performance of these complex cycles is found to be a function of the molecular complexity of the working fluid, the reduced evaporation temperature, the fractional temperature lift and the number of stages of throttling. Furthermore, complex cycles are shown to be equivalent to a combination of simple cycles and their performance may be directly inferred by this route. Such calculations show that for a given fractional temperature lift an optimum molecular complexity (between that of R12 and n-butane) exists. Fluids with simpler molecules exhibit excessive vapour superheating during compression, and those with more complex molecules have excessive throttling losses. Also, with complex cycles, regeneration should be applied only to the cycle at the lowest temperature in order to improve the cycle COP and to prevent condensation during compression. As a general trend, however, complex cycles suffer a significant loss in performance compared to optimized simple cycles due to the adverse area of the two-phase diagram in which they work.  相似文献   

9.
The thermodynamic properties (solubility, vapour pressure, density, viscosity, heat capacity and heat of mixing) of the H2O + CH3OH + LiBr + ZnCl2 (9:1 H2O:CH3OH and 1:1 LiBr:ZnCl2 by mass) system using H2O + CH3OH as the working media and LiBr + ZnCl2 as the absorbents were measured. The solubility data were obtained in the temperature range from 270.35 to 389.55 K. The measurements of vapour pressure, density, viscosity and heat capacity were carried out at various temperatures and absorbent concentrations. The differential heat of dilution and differential heat of solution at 298.15 K were measured for solutionw with absorbent concentrations from 0 to 75.2 wt%. The integral heat of mixing data at 298.15 K were obtained from both sets of experimental data. The integral heats of mixing for this quaternary system showed exothermic behaviour. The vapour pressure data were correlated with an Antoine-type equation. An empirical formula for the heat capacity was obtained from experimental data. The experimental data for the basic thermodynamic properties of this quaternary system were compared with those of the basic H2O + LiBr system.  相似文献   

10.
In order to settle the problem of the corrosion between sea water and the steel adsorber for ammonia system, a split heat pipe type adsorption ice making test unit, which use compound adsorbent of CaCl2 and activated carbon to improve the adsorption performance, is designed and constructed. For this test unit there is mass recovery function between two beds and the CaCl2 in compound adsorbent per bed is 1.88 kg, and there is only one pump for the whole heating and cooling phase for adsorbers. Performances of this system are tested; the lowest evaporating temperature is as low as −42 °C. At the evaporating temperature of −35 and −25 °C, the cooling powers are 0.89 and 1.18 kW, respectively. At the evaporating temperature of −15 °C, its average cooling power is 1.37 kW, which corresponds coefficient of performance of refrigeration COP=0.41 and specific cooling power per kilogram CaCl2 of each adsorber SCP=731 W kg−1. The mass recovery process has improved SCP and COP for the system by 15.5 and 24.1%, respectively. Heat transfer performance is also improved by the split heat pipe construction; the average heat transfer coefficient for a whole cycle is 155.8 W m−2 °C−1.  相似文献   

11.
In this study, computer simulation programs were developed for multi-stage condensation heat pumps and their performance was examined for CFC11, HCFC123, HCFC141b under the same condition. The results showed that the coefficient of performance (COP) of an optimized ‘non-split type’ three-stage condensation heat pump was 25–42% higher than that of a conventional single-stage heat pump. The increase in COP differed among the fluids examined. The improvement in COP was due largely to the decrease in average temperature difference between the refrigerant and water in the condensers, which resulted in a decrease in thermodynamic irreversibility. For the three-stage heat pump, the highest COP was achieved when the total condenser area was evenly distributed to the three condensers. For the two-stage heat pump, however, the optimum distribution of total condenser area varied with working fluids. For the three-stage system, splitting the condenser cooling water for the use of intermediate and high pressure subcoolers helped increase the COP further. When the individual cooling water for the intermediate and high pressure subcoolers was roughly 10% of the total condenser cooling water, the optimum COP was achieved showing an additional 11% increase in COP as compared to that of the ‘non-split type’ for the three-stage heat pump system.  相似文献   

12.
A single-stage vapour absorption refrigeration system (VARS) is tested with monochlorodifluoromethane (HCF22) as refrigerant and different absorbents: dimethylether of tetraethylene glycol (DMETEG) and dimethyl acetamide (DMA). The influence of generator temperatures in the range 75–95°C, which represents low-grade heat sources, is studied. Cooling water temperatures were varied between 20 and 30°C. Two cases of cooling water flow paths are considered, i.e. water entering either absorber or condenser, which are connected in series. For HCFC22-DMETEG, COP values in the range 0.2–0.36 and evaporator temperatures between 0 and 10°C are obtained. For HCF22-DMA, COP values in the range 0.3–0.45 and evaporator temperatures between −10 and 10°C are obtained. It is observed that HCFC22-DMETEG can work at lower heat source temperatures than HCFC22-DMA. However, at the same operating conditions HCFC22-DMA is better from the viewpoints of circulation ratio and COP. Experiments also show that at low heat source temperature, cooling water temperature has strong influence on circulation ratio but does not affect COP significantly. Preferably, cooling water should first flow through the condenser and then through the absorber in order to achieve improved overall performance.  相似文献   

13.
Thermal heat driven adsorption systems have been gained considerable attention on the recent energy utilization trend. However, the drawbacks of these adsorption systems are their poor performance. It is urgently necessary to improve the system performance of the adsorption cycles. There are two major ways for the system performance improvement. One is to develop new adsorbent material well suited to low temperature heat regeneration. The other is to enhance heat and mass transfer in the adsorber/desorber heat exchanger. The objective of the paper is to investigate the system performance of an adsorption cycle. The cycle utilizes activated carbon fiber (ACF)/methanol as adsorbent/refrigerant pair. In this paper, specific cooling effect SCE and COP of the system are numerically evaluated from the adsorption equilibrium theory with different hot, cooling and chilled fluid inlet temperatures. It is confirmed that the influences of hot, cooling and chilled fluid inlet temperatures on the system performance are qualitatively similar to those of silica gel/water pair. Even though, the driving temperature levels of ACF/methanol and silica gel/water are different. There is an optimum condition for COP to reach at maximum for ACF/methanol pair. Particularly, the ACF/methanol system shows better performance with lower chilled fluid inlet temperature between −20 and 20 °C.  相似文献   

14.
Experimental investigation of mass recovery adsorption refrigeration cycle   总被引:1,自引:0,他引:1  
The study investigates the performance of silica gel–water adsorption refrigeration cycle with mass recovery process by experimental prototype machine. In an adsorption refrigeration cycle, the pressures in adsorber and desorber are different. The mass recovery cycle utilizes the pressure difference to enhance the refrigerant mass circulation. Moreover, novel cycle was proposed for improvement of cooling output. In our previous study, simulation analysis shows that mass recovery cycle has the advantage over conventional single-stage. Experiments with prototype machine were conducted to investigate the performance improvement of mass recovery cycle in the present paper. Specific cooling power (SCP) and coefficient of performance (COP) were calculated with experimental data to analyze the influences of operating conditions. The proposed cycle was compared with the single-stage cycle in terms of SCP and COP. The results show that SCP of mass recovery cycle is superior to that of conventional cycle and mass recovery cycle is effective with low temperature heat source.  相似文献   

15.
Over the past few decades there have been considerable efforts to use adsorption (solid/vapor) for cooling and heat pump applications, but intensified efforts were initiated only since the imposition of international restrictions on the production and utilization of CFCs and HCFCs. In this paper, a dual-mode silica gel–water adsorption chiller design is outlined along with the performance evaluation of the innovative chiller. This adsorption chiller utilizes effectively low-temperature solar or waste heat sources of temperature between 40 and 95 °C. Two operation modes are possible for the advanced chiller. The first operation mode will be to work as a highly efficient conventional chiller where the driving source temperature is between 60 and 95 °C. The second operation mode will be to work as an advanced three-stage adsorption chiller where the available driving source temperature is very low (between 40 and 60 °C). With this very low driving source temperature in combination with a coolant at 30 °C, no other cycle except an advanced adsorption cycle with staged regeneration will be operational. The drawback of this operational mode is its poor efficiency in terms of cooling capacity and COP. Simulation results show that the optimum COP values are obtained at driving source temperatures between 50 and 55 °C in three-stage mode, and between 80 and 85 °C in single-stage, multi-bed mode.  相似文献   

16.
A novel CO2 heat pump system was provided for use in fuel cell vehicles, when considering the heat exchanger arrangements. This cycle which had an inverter-controlled, electricity-driven compressor was applied to the automotive heat pump system for both cooling and heating. The cooling and heating loops consisted of a semi-hermetic compressor, supercritical pressure microchannel heat exchangers (a gas cooler and a cabin heater), a microchannel evaporator, an internal heat exchanger, an expansion valve and an accumulator. The performance characteristics of the CO2 heat pump system for fuel cell vehicles were analyzed by experiments. Results for steady and transient state performance were provided for various operating conditions. Furthermore, experiments to examine the arrangements of a radiator and an outdoor heat exchanger were carried out by changing their positions for both cooling and heating conditions. The arrangements of the radiator and the outdoor heat exchanger were tested to quantify cooling/heating effectiveness and mutual interference. The improvement of heating capacity and coefficient of performance (COP) of the CO2 heat pump system was up to 54% and 22%, respectively, when using preheated air through the radiator instead of cold ambient air. However, the cooling capacity quite decreased by 40–60% and the COP fairly decreased by 43–65%, for the new radiator-front arrangement.  相似文献   

17.
The main purpose of this study is to investigate the performance of a transcritical CO2 cycle with an internal heat exchanger for hot water heating. Performance test and simulation have been carried out for a transcritical CO2 cycle by varying secondary heat transfer fluid temperatures at evaporator and gas-cooler inlets as well as the discharge pressure. Variations of mass flow rate of refrigerant, compressor power, heating capacity, and co-efficient of performance (COP) with respect to the length of an internal heat exchanger are presented at various operating conditions. Good quantitative agreement between model predictions and experimental results has been found; most parameters have absolute average deviations of less than 4%. As the length of the internal heat exchanger increases, COP is enhanced but heating capacity tends to decrease due to the trade-offs between the effectiveness and pressure drop in the internal heat exchanger.  相似文献   

18.
The cooling performance of a consolidated composite reactive bed made from expanded graphite impregnated with CaCl2 was experimentally assessed under different evaporation and heat sink temperatures. The compound presented a specific cooling power (SCP) higher than 1000 W kgSalt−1 at several studied conditions. The calculated coefficient of performance (COP) was about 0.35 when the amount of refrigerant consumed in the reaction was 0.80 kg kgSalt−1. Both SCP and COP changed with the cycle time, and thus, with the degree of the reaction. The synthesis time to maximise the SCP, under any studied condition, was about 5 min, and the absorbed quantity greatly varied among the different operation conditions. When compared to the time necessary to obtain an absorbed amount of 0.80 kg kgSalt−1, the synthesis time of 5 min could improve the SCP in about 15–68%, however, COP would be deployed in about 14–50%.  相似文献   

19.
The Carnot COP, which assumes a thermodynamically ideal cycle in which no irreversibilities exist, is often considered to be a design goal for actual cycles. However, the Carnot COP does not consider heat transfer mechanisms. Heat transfer at a finite rate is necessarily an irreversible process and unavoidable in a refrigeration cycle. The lack of consideration of rate processes reduces the usefulness of the Carnot COP as a realistic design goal. In this paper, the limitations of both thermodynamics and heat transfer are considered to identify a more realistic design goal for the COP of refrigeration cycles. The consideration of heat transfer limitations leads to a design rule for the optimum distribution of heat exchange area between the low- and high-temperature heat exchangers.  相似文献   

20.
Non-azeotropic refrigerant mixtures (NARMs) are investigated for a two-temperature level heat exchange process found in a domestic refrigerator-freezer. Ideal (constant air temperature) heat exchange processes are assumed. The results allow the effects of intercooling between the evaporator refrigerant stream and the condenser outlet stream to be examined in a systematic manner. For the conditions studied, an idealized NARM system will have a limiting coefficient of performance (COP) that is less than that of the best performing pure refrigerant component. However, for non-ideal heat exchange processes (gliding air temperature), the NARM-based system can have a higher limiting COP than a system running on either pure NARM component. Intercooling significantly affects the COP of NARM-based systems; however, depending on the location of ‘pinch points’ in the heat exchangers, only one intercooling heat exchanger may be needed to obtain a NARM's maximum refrigerator COP. The results are presented for mixtures of R22–R142b, R22–R123 and R32–R142b.  相似文献   