首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 923 毫秒
1.
Using an optical system made from fused silica catalogue optical components, third‐order nonlinear microscopy has been enabled on conventional Ti:sapphire laser‐based multiphoton microscopy setups. The optical system is designed using two lens groups with straightforward adaptation to other microscope stands when one of the lens groups is exchanged. Within the theoretical design, the optical system collects and transmits light with wavelengths between the near ultraviolet and the near infrared from an object field of at least 1 mm in diameter within a resulting numerical aperture of up to 0.56. The numerical aperture can be controlled with a variable aperture stop between the two lens groups of the condenser. We demonstrate this new detection capability in third harmonic generation imaging experiments at the harmonic wavelength of ~300 nm and in multimodal nonlinear optical imaging experiments using third‐order sum frequency generation and coherent anti‐Stokes Raman scattering microscopy so that the wavelengths of the detected signals range from ~300 nm to ~660 nm.  相似文献   

2.
Chen J  Zhuo S  Luo T  Jiang X  Zhao J 《Scanning》2006,28(6):319-326
The spectral properties of one-photon, two-photon excited autofluorescence and second harmonic generation (SHG) from ex vivo human skin induced by a femtosecond (fs) laser and three visible lasers in backscattering geometry are systematically investigated. Our experimental results indicate that peak position of autofluorescence spectra from the dermis and epidermis shift toward long wavelengths, and the fluorescent intensity decreases when the excitation wavelength increases due to an effect of the excitation wavelength on autofluorescence signals. However, the intensity of the SHG signal in collagen has the maximal value of 800 nm excitation wavelength. This may be the result that the energy of the SHG signal is in resonance with an electronic absorption band. The two-photon excited autofluorescence and SHG intensity all obey a quadratical dependence on the excitation power. Compared with the two-photon excited fluorescence and SHG, the one-photon excited fluorescence in the dermis and epidermis exhibits different spectral characteristics. The investigation of the spectral characteristics of autofluorescence and SHG from ex vivo human skin can provide new insights into morphologic structures and biochemical components of tissues, which are vital for improving the application of laser-induced autofluorescence and SHG spectroscopy technique for noninvasive in vivo tissue diagnostics.  相似文献   

3.
A variety of high resolution optical microscopy techniques have been developed in recent years for basic and clinical studies of biological systems. We demonstrate a trimodal microscope combining optical coherence microscopy (OCM) with two forms of nonlinear microscopy, namely two-photon excited fluorescence (2PF) and second harmonic generation (SHG), for imaging turbid media. OCM combines the advantages of confocal detection and coherence gating for structural imaging in highly scattering tissues. Nonlinear microscopy enables the detection of biochemical species, such as elastin, NAD(P)H, and collagen. While 2PF arises from nonlinear excitation of fluorescent species, SHG is a form of nonlinear scattering observed in materials that lack a center of inversion symmetry, such as type I collagen. Characterization of the microscope showed nearly diffraction-limited spatial resolution in all modalities. Images were obtained in fish scales and excised human skin samples. The primary endogenous sources of contrast in the dermis were due to elastin autofluorescence and collagen SHG. Multimodal microscopy allows the simultaneous visualization of structural and functional information of biological systems.  相似文献   

4.
In this work, we proposed and built a multimodal optical setup that extends a commercially available confocal microscope (Olympus VF300) to include nonlinear second harmonic generation (SHG) and third harmonic generation (THG) optical (NLO) microscopy and fluorescence lifetime imaging microscopy (FLIM). We explored all the flexibility offered by this commercial confocal microscope to include the nonlinear microscopy capabilities. The setup allows image acquisition with confocal, brightfield, NLO/multiphoton and FLIM imaging. Simultaneously, two‐photon excited fluorescence (TPEF) and SHG are well established in the biomedical imaging area, because one can use the same ultrafast laser and detectors set to acquire both signals simultaneously. Because the integration with FLIM requires a separated modulus, there are fewer reports of TPEF+SHG+FLIM in the literature. The lack of reports of a TPEF+SHG+THG+FLIM system is mainly due to difficulties with THG because the present NLO laser sources generate THG in an UV wavelength range incompatible with microscope optics. In this article, we report the development of an easy‐to‐operate platform capable to perform two‐photon fluorescence (TPFE), SHG, THG, and FLIM using a single 80 MHz femtosecond Ti:sapphire laser source. We described the modifications over the confocal system necessary to implement this integration and verified the presence of SHG and THG signals by several physical evidences. Finally, we demonstrated the use of this integrated system by acquiring images of vegetables and epithelial cancer biological samples. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

5.
Near-field optical second harmonic microscopy has been applied to imaging of the c/a/c/a polydomain structure of epitaxial PbZr x Ti1– x O3 thin films in the 0 <  x  < 0.4 range. Comparison of the near-field optical images and the results of atomic force microscopy and X-ray diffraction studies show that an optical resolution of the order of 100 nm is achieved. Symmetry properties of the near-field second harmonic signal allow us to obtain good optical contrast between the local second harmonic generation in c- and a-domains. Experimentally measured near-field second harmonic images have been compared with the results of theoretical calculations. Good agreement between theory and experiment is demonstrated.  相似文献   

6.
Sun CK  Chu SW  Tai SP  Keller S  Abare A  Mishra UK  DenBaars SP 《Scanning》2001,23(3):182-192
Taking advantage of the electric field-enhanced second-harmonic generation effect in bulk gallium nitride (GaN) and indium gallium nitride (InGaN) quantum wells, we demonstrated the piezoelectric field distribution mapping in bulk GaN and InGaN multiple-quantum-well (MQW) samples using scanning second-harmonic generation (SHG) microscopy. Scanning SHG microscopy and the accompanying third-harmonic generation (THG) microscopy of the bulk GaN sample were demonstrated using a femtosecond Cr:forsterite laser at a wavelength of 1230 nm. Taking advantage of the off-resonant electric field-enhanced SHG effect and the bandtail state-resonance THG effect, the second- and third-harmonic generation microscopic images obtained revealed the piezoelectric field and bandtail state distributions in a GaN sample. Combined with 720 nm wavelength excited two-photon fluorescence microscopy in the same sample, the increased defect density around the defect area was found to suppress bandedge photoluminescence, to increase yellow luminescence, to increase bandtail state density, and to decrease residue piezoelectric field intensity. Scanning SHG microscopy of the InGaN MQW sample was resonant excited with 800 nm femtosecond pulses from a Ti:sapphire laser in order to suppress SHG contribution from the bulk GaN substrate. Taking advantage of the strong piezoelectric field inside the InGaN quantum well, the wavelength resonant effect, and the electric field-enhanced SHG effect of InGaN quantum wells, resonant scanning SHG microscopy revealed the piezoelectric field distribution inside the wells. Combined with accompanying three-photon fluorescence microscopy from the bulk GaN substrate underneath the quantum wells, the direct correspondence between the piezoelectric field strength inside the quantum well and the substrate quality can be obtained. According to our study, the GaN substrate area with bright bandedge luminescence corresponds to the area with strong SHG signals indicating a higher stained-induced piezoelectric field. These scanning harmonic generation microscopies exhibit superior images of the piezoelectric field and defect state distributions in GaN and InGaN MQWs not available before. Combining with scanning multiphoton fluorescence microscopy, these techniques open new ways for the physical property study of this important material system and can provide interesting details that are not readily available by other microscopic techniques.  相似文献   

7.
Near-field optical microscopy has been used to image variations in local optical second harmonic generation (SHG) from the surface of lead zirconate titanate (PZT) piezoceramic. As PZT ceramic is a strongly scattering medium, SHG occurs in the thin layer near the surface of the ceramic. Thus, individual crystalline grains and grain boundaries located near the surface are the main features visible in the images. In general, this technique allows us to determine the local poling direction of individual submicrometre-sized crystalline grains of ceramic by near-field SH imaging at different angles of incidence and polarization states of the fundamental excitation light. In some cases 'hot spots' of submicrometre size showing enhanced SHG have been observed. This enhancement is believed to result from local cavity resonances.  相似文献   

8.
Multiphoton microscopy is a powerful technique based on complex quantum mechanical effects. Thanks to the development of turnkey mode-locked laser systems, multiphoton microscopy is now available for everyone to use without extreme complexity. In this short introduction, we describe qualitatively the important concepts underlying the most commonly used type of multiphoton microscopy (two-photon excitation). We elucidate how those properties lead to the powerful results that have been achieved using this technique. As with any technique, two-photon excitation microscopy has limitations that we describe, and we provide examples of particular classes of experiments where two-photon excitation microscopy is advantageous over other approaches. Finally, we briefly describe other useful multiphoton microscopy approaches, such as three-photon excitation and second harmonic generation imaging.  相似文献   

9.
Chirality is one of the most fundamental and essential structural properties of biological molecules. Many important biological molecules including amino acids and polysaccharides are intrinsically chiral. Conventionally, chiral species can be distinguished by interaction with circularly polarized light, and circular dichroism is one of the best‐known approaches for chirality detection. As a linear optical process, circular dichroism suffers from very low signal contrast and lack of spatial resolution in the axial direction. It has been demonstrated that by incorporating nonlinear interaction with circularly polarized excitation, second‐harmonic generation circular dichroism can provide much higher signal contrast. However, previous circular dichroism and second‐harmonic generation circular dichroism studies are mostly limited to probe chiralities at surfaces and interfaces. It is known that second‐harmonic generation, as a second‐order nonlinear optical effect, provides excellent optical sectioning capability when combined with a laser‐scanning microscope. In this work, we combine the axial resolving power of second‐harmonic generation and chiral sensitivity of second‐harmonic generation circular dichroism to realize three‐dimensional chiral detection in biological tissues. Within the point spread function of a tight focus, second‐harmonic generation circular dichroism could arise from the macroscopic supramolecular packing as well as the microscopic intramolecular chirality, so our aim is to clarify the origins of second‐harmonic generation circular dichroism response in complicated three‐dimensional biological systems. The sample we use is starch granules whose second‐harmonic generation‐active molecules are amylopectin with both microscopic chirality due to its helical structure and macroscopic chirality due to its crystallized packing. We found that in a starch granule, the second‐harmonic generation for right‐handed circularly polarized excitation is significantly different from second‐harmonic generation for left‐handed one, offering excellent second‐harmonic generation circular dichroism contrast that approaches 100%. In addition, three‐dimensional visualization of second‐harmonic generation circular dichroism distribution with sub‐micrometer spatial resolution is realized. We observed second‐harmonic generation circular dichroism sign change across the starch granules, and the result suggests that in thick biological tissue, second‐harmonic generation circular dichroism arises from macroscopic molecular packing. Our result provides a new method to visualize the organization of three‐dimensional structures of starch granules. The second‐harmonic generation circular dichroism imaging method expands the horizon of nonlinear chiroptical studies from simplified surface/solution environments to complicated biological tissues.  相似文献   

10.
Second‐harmonic generation (SHG) microscopy has gained popularity because of its ability to perform submicron, label‐free imaging of noncentrosymmetric biological structures, such as fibrillar collagen in the extracellular matrix environment of various organs with high contrast and specificity. Because SHG is a two‐photon coherent scattering process, it is difficult to define a point spread function (PSF) for this modality. Hence, compared to incoherent two‐photon processes like two‐photon fluorescence, it is challenging to apply the various PSF‐engineering methods to improve the spatial resolution to be close to the diffraction limit. Using a synthetic PSF and application of an advanced maximum likelihood estimation (AdvMLE) deconvolution algorithm, we demonstrate restoration of the spatial resolution in SHG images to that closer to the theoretical diffraction limit. The AdvMLE algorithm adaptively and iteratively develops a PSF for the supplied image and succeeds in improving the signal to noise ratio (SNR) for images where the SHG signals are derived from various sources such as collagen in tendon and myosin in heart sarcomere. Approximately 3.5 times improvement in SNR is observed for tissue images at depths of up to ~480 nm, which helps in revealing the underlying helical structures in collagen fibres with an ~26% improvement in the amplitude contrast in a fibre pitch. Our approach could be adapted to noisy and low resolution modalities such as micro‐nano CT and MRI, impacting precision of diagnosis and treatment of human diseases.  相似文献   

11.
Surface-enhanced second harmonic generation from individual topographical defects of an otherwise flat gold film and from metal-coated diffraction gratings was measured using a near-field optical microscope. Experimentally measured second harmonic field distributions were compared with theoretical calculations.  相似文献   

12.
To understand the reported difference between double band, sarcomeric second harmonic generation pattern of isolated myofibril and predominant single band pattern found in thick muscle tissues, we studied the effect of myofibril preparation on the second harmonic generation pattern. We found that double band sarcomeric second harmonic generation pattern usually observed in myofibrils (prepared from fresh tissue) is due to muscle alteration during the mixing and triton treatment processes. Single band sarcomeric second harmonic generation pattern could be observed in isolated myofibrils when this alteration is previously prevented using paraformaldehyd fixed tissue. We conclude that single band sarcomeric second harmonic generation pattern is a signature of adult muscle myofibrils in normal physiological condition, suggesting that sarcomeric second harmonic generation patterns could be used as a valuable diagnosis tool of muscle health.  相似文献   

13.
The aim of this work is to demonstrate that multiphoton microscopy is a preferred technique to investigate intact cornea structure without slicing and staining. At the micron resolution, multiphoton imaging can provide both large morphological features and detailed structure of epithelium, corneal collagen fibril bundles and keratocytes. A large area multiphoton cross-section across an intact eye excised from a GFP mouse was obtained by a homebuilt multiphoton microscope. The broadband multiphoton fluorescence (435-700 nm) and second harmonic generation (SHG, 360-400 nm) signals were generated by the 760 nm output of a femtosecond titanium-sapphire laser. A water immersion objective (Fluor, 40X, NA 0.8; Nikon) was used to facilitate imaging the curve ocular surface. The multiphoton image over entire cornea provides morphological information of epithelial cells, keratocytes, and global collagen orientation. Specifically, our planar, large area multiphoton image reveals a concentric pattern of the stroma collagen, indicative of the laminar collagen organization throughout the stroma. In addition, the green fluorescence protein (GFP) labeling contributed to fluorescence contrast of cellular area and facilitated visualizing of inactive keratocytes. Our results show that multiphoton imaging of GFP labeled mouse cornea manifests both morphological significance and structural details. The second harmonic generation imaging reveals the collagen orientation, while the multiphoton fluorescence imaging indicates morphology and distribution of cells in cornea. Our results support that multiphoton microscopy is an appropriate technology for further in vivo investigation and diagnosis of cornea.  相似文献   

14.
Highly optically active nonlinear bio‐photonic crystalline and semicrystalline structures in living cells were studied by a novel multimodal nonlinear microscopy. Numerous biological structures, including stacked membranes and aligned protein structures are highly organized on a nanoscale and have been found to exhibit strong optical activities through second‐harmonic generation (SHG) interactions, behaving similarly to man‐made nonlinear photonic crystals. The microscopic technology used in this study is based on a combination of different imaging modes including SHG, third‐harmonic generation, and multiphoton‐induced fluorescence. With no energy release during harmonic generation processes, the nonlinear‐photonic‐crystal‐like SHG activity is useful for investigating the dynamics of structure–function relationships at subcellular levels and is ideal for studying living cells, as minimal or no preparation is required.  相似文献   

15.
We investigated possibilities of the combination of the one- and two-photon excitation microscopy for examination of the experimental melanoma tissue in vivo, in mice under general anesthesia, and ex vivo on freshly harvested specimens. Our aim was to obtain sufficiently informative images of unstained tumor tissues and their modifications after hyperthermia treatment. The mouse experimental melanoma structure was studied and compared with normal tissue from the same animal by using confocal and nonlinear microscopy techniques based on (i) one-photon excitation (1PE) fluorescence, (ii) 1PE reflectance, (iii) second harmonic generation imaging, and (iv) two-photon excitation autofluorescence. We checked different spectral conditions and other settings of image acquisition, as well as combinations of the above imaging modalities, to fully exploit the potential of these techniques in the evaluation of treated and untreated cancer tissue morphology. Our approach enabled to reveal the collagen fiber network in relation with the other tissues, and to identify invasive tumor cells. It also proved to be useful for the examination of interrelationships between functional and morphological aspects based on optical properties of the tissues, especially in studies of changes between the tumor and control tissue, as well as changes induced by physical treatments, e.g., delivery of microwave hyperthermia treatment. These differences were also evaluated quantitatively, when we found out that the maximum Euler–Poincaré characteristic reflects well the melanoma morphological structure. The results showed that the proposed investigative approach could be suitable also for a direct evaluation of tissue modifications induced by clinical interventions. Microsc. Res. Tech., 2009. © 2009 Wiley-Liss, Inc.  相似文献   

16.
Optical second‐harmonic generation is a recently developed technique in surface science, the range of applications of which has been steadily broadening. It allows, among other things, the direct probing of molecular adsorption on to a solid substrate from a liquid or gaseous environment. This paper reports on the possibility of applying it to tribological studies. A set of possible experiments that could offer information, in particular, on the working principle of those oil additives, commonly used in the lubricant industry, whose effect derives from surface adsorption, are discussed briefly. In addition, the preliminary results of a first experiment are described.  相似文献   

17.
Zheng L  Zhuo S  Chen G  Zhu X  Jiang X  Yan J  Chen J  Xie S 《Scanning》2011,33(4):208-210
Early detection of fibroadenoma (FA) is critical for preventing subsequent breast cancer. In this work, we show that label-free second harmonic generation (SHG) imaging is feasible and effective in quantitatively differentiating the fibroadenomal tissue from normal breast tissue. With the advent of the clinical portability of miniature SHG microscopy, we believe that the technique has great potential in offering a noninvasive in vivo imaging tool for early detection of FA and monitoring the treatment responses of FA in clinics.  相似文献   

18.
Background : Multifunctional two‐photon laser scanning microscopy provides attractive advantages over conventional two‐photon laser scanning microscopy. For the first time, simultaneous measurement of the second harmonic generation (SHG) signals in the forward and backward directions and two photon excitation fluorescence were achieved from the deep shade plant Selaginella erythropus. Results : These measurements show that the S. erythropus leaves produce high SHG signals in both directions and the SHG signals strongly depend on the laser's status of polarization and the orientation of the dipole moment in the molecules that interact with the laser light. The novelty of this work is (1) uncovering the unusual structure of S. erythropus leaves, including diverse chloroplasts, various cell types and micromophology, which are consistent with observations from general electron microscopy; and (2) using the multifunctional two‐photon laser scanning microscopy by combining three platforms of laser scanning microscopy, fluorescence microscopy, harmonic generation microscopy and polarizing microscopy for detecting the SHG signals in the forward and backward directions, as well as two photon excitation fluorescence. Conclusions : With the multifunctional two‐photon laser scanning microscopy, one can use noninvasive SHG imaging to reveal the true architecture of the sample, without photodamage or photobleaching, by utilizing the fact that the SHG is known to leave no energy deposition on the interacting matter because of the SHG virtual energy conservation characteristic.  相似文献   

19.
We describe a novel two‐photon fluorescence microscopy system capable of producing high‐quality second harmonic generation (SHG) images in thick turbid media by using an innovative detection system. This novel detection system is capable of detecting photons from a very large surface area. This system has proven effective in providing images of thick turbid samples, both biological and artificial. Due to its transmission detection geometry, the system is particularly suitable for detecting SHG signals, which are generally forward directed. In this article, we present comparative data acquired simultaneously on the same sample with the forward and epidetection schemes. Microsc. Res. Tech. 77:368–373, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

20.
Two-photon fluorescence surface wave microscopy   总被引:1,自引:0,他引:1  
This paper demonstrates the principle of two-photon surface wave microscopy with a view to applications on biological samples. We describe a modified scanning optical microscope, which uses specially prepared coverslips. These coverslips are designed to support the propagation of surface waves capable of large field enhancements. We also discuss the beam conditioning necessary to ensure efficient use of the available illumination. Two-photon surface wave fluorescent excitation is demonstrated on fluorescent nanospheres, demonstrating a point spread function width of ≈220 nm at an illumination wavelength of 925 nm. The potential of non-linear surface wave excitation for both fluorescence and harmonic imaging microscopy is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏