首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Peak acoustic power limits the signal-to-noise ratio (SNR) of real-time ultrasound images. For most conventional scan formats, however, the average power is well below heating limits. This means the SNR can be significantly increased using coded excitation. A coded system transmits a broadband, temporally elongated excitation pulse with a finite time-bandwidth product. The received signal must be decoded to produce an imaging pulse with improved SNR resulting from the higher average power in the elongated excitation. Decoding can produce significant range side lobes, however, greatly reducing image quality. All practical coding designs, therefore, represent a trade-off between SNR gain and range side lobes. A specific coding scheme appropriate for synthetic aperture imaging is presented. A 14.5 dB SNR improvement with acceptable range side lobes is demonstrated on a forward-looking imaging system appropriate for intravascular applications.  相似文献   

2.
In this paper, a scheme called coded excitation with spectrum inversion (CEXSI) is presented. An established optimal binary code whose spectrum has no s and possesses the least variation is encoded as a burst for transmission. Using this optimal code, the decoding filter can be derived directly from its inverse spectrum. Various transmission techniques can be used to improve energy coupling within the system pass-band. We demonstrate its potential to achieve excellent decoding with very low (<80 dB) side-lobes. For a 2.6 /spl mu/s code, an array element with a center frequency of 10 MHz and fractional bandwidth of 38%, range side-lobes of about 40 dB have been achieved experimentally with little compromise in range resolution. The signal-to-noise ratio (SNR) improvement also has been characterized at about 14 dB. Along with simulations and experimental data, we present a formulation of the scheme, according to which CEXSI can be extended to improve SNR in sparse array imaging in general.  相似文献   

3.
Based on an analysis of the inherent signal-to-noise ratio (SNR) in medical ultrasound imaging, SNR improvements of 15-20 dB are theoretically possible for real-time phased-array imagers using coded excitation. A very simple coded excitation for phased arrays based on the principles of ;pseudochirp' excitation and equalization filtering is described. This system is capable of SNR improvements of about 15 dB with range sidelobe levels acceptable for many medical imaging applications. Such improvements permit increased operating frequencies, and hence enhanced spatial resolution, for real-time array imagers. Both simulations and measurements are used to demonstrate the efficacy of the method.  相似文献   

4.
Practical spread spectrum pulse compression for ultrasonic tissue imaging   总被引:1,自引:0,他引:1  
Spread spectrum pulse compression is a signal processing algorithm that enhances critical system performance parameters such as signal-to-noise ratio, peak power requirements, minimum detectable signal, and total dynamic range. For this research, a digital, real-time, Barker coded, bi-phase modulator was designed and constructed, as well as a simple ultrasonic test tank containing both synthetic targets and excised goat's liver. Upon reception and demodulation of the spread spectrum ultrasonic echo, cross-correlation with a sidelobe suppression filter was performed. Due to limitations such as narrow bandwidth, and very short minimum ranges, a practical ultrasonic pulse compression system must be restricted to short code lengths. For 13 bit Barker code compression, the expected increase in signal-to-noise ratio of 11 dB was realized; at the same time greater than 30 dB of instantaneous dynamic range was maintained.  相似文献   

5.
Linear power amplifiers are critical components in ultrasonic imaging systems that implement chirp-coded excitation. Bench-top commercial power amplifiers are usually used in academic laboratories for high-frequency ultrasound imaging, and the imaging performance depends greatly on these general-purpose instruments. To achieve a wide dynamic range, a power amplifier consisting of two stages is developed for chirp-coded ultrasound imaging applications through the implementation of custom-designed broadband 1:1 transformers and the optimization of feedback circuits. The amplifier has broad bandwidth (5 to 135 MHz), maintaining a linearity up to the 1-dB gain compression point (P1dB) of 41.5 dBm, allowing 16 dBm input power level at 60 MHz. The mean and the maximum values of output third-order intercept points (OIP3) are 51.8 and 53.5 dBm, respectively, between 20 and 110 MHz. With 12 dBm input power, the gain of the amplifier varies between 24 and 29 dB, offering a uniformity which would allow excitation of a 70-MHz single-element transducer with windowed chirp-coded bursts sweeping from 40 to 100 MHz. The performance in high-frequency ultrasound imaging is evaluated with a wire phantom. Echo signal-to-noise ratio (eSNR) of the designed amplifier is 7 dB better than a commercial amplifier, and spatial resolution is maintained.  相似文献   

6.
This work deals with improving the resolution of ultrasonic ranging systems by means of preshaping the transmitter drive signals to achieve low transient acoustic pulses. As ultrasonic transducers are operated at a relatively high nominal frequency and quality factor, feedforward strategy is among the most efficient means to generate the low transient acoustic pulses. In this work, a digital signal processor and a field programmable gate array synthesize the transmitter drive signal to emit low transient pulses which are then applied to the detection of surface features. Both simulation and experiment results confirm an improved spatial detection resolution due to the lower acoustic transient interference. The drive signal synthesis process is also simpler than the conventional modulation method and should result in lower cost of implementation.  相似文献   

7.
Ultrasonic pulse echo imaging in inhomogeneous media suffers from significant lateral and contrast resolution losses due to the defocusing effects of the inhomogeneities. The losses in lateral and contrast resolution are associated with increases in the width of the mainbeam and increases in sidelobe levels, respectively. These two forms of resolution loss represent significant hurdles to improving the clinical utility of biomedical ultrasonic imaging. A number of research efforts are currently under way to investigate the defocusing effects of tissue and to consider corrective measures. All of these efforts assume linear propagation, and base the image-formation process on the reception of the transmitted pulse. A novel pulse echo imaging scheme in which the image is formed using the finite amplitude distortion components of the received pulse is considered here. Alternatively, this could be described as image formation using the nonlinearly-generated higher harmonics. In homogeneous beam propagations, it has been established that the sidelobes of nonlinearly-generated higher harmonics are much lower than their linear counterparts. Computations considered here suggest that this relationship also holds for the case of propagations through abdominal wall and breast wall tissue. These computations also suggest that the lateral resolution limits imposed by abdominal wall and breast wall tissue are slightly smaller for nonlinearly-generated second harmonics than for their linear counterparts. The resulting potential of these higher harmonics to improve image resolution is investigated.  相似文献   

8.
Previous ultrasound speckle tracking methods have been extended, permitting measurement of internal displacement and strain fields over a wide dynamic range of tissue motion. The markedly increased dynamic range of this approach should lead to enhanced contrast resolution in strain and elasticity images. Results of experiments on gelatin-based, tissue equivalent phantoms show the capabilities of the method  相似文献   

9.
Resolution and penetration are primary criteria for clinical image quality. Conventionally, high bandwidth for resolution was achieved with a short pulse, which results in a tradeoff between resolution and penetration. Coded excitation extends the bounds of this tradeoff by increasing signal-to-noise ratio (SNR) through appropriate coding on transmit and decoding on receive. Although used for about 50 years in radar, coded excitation was successfully introduced into commercial ultrasound scanners only within the last 5 years. This delay is at least partly due to practical implementation issues particular to diagnostic ultrasound, which are the focus of this paper. After reviewing the basics of biphase and chirp coding, we present simulation results to quantify tradeoffs between penetration and resolution under frequency-dependent attenuation, dynamic focusing, and nonlinear propagation. Next we compare chirp and Golay code performance with respect to image quality and system requirements, then we show clinical images that illustrate the current applications of coded excitation in B-mode, harmonic, and flow imaging.  相似文献   

10.
Ultrasonic strain imaging that uses signals from conventional diagnostic ultrasound systems is capable of showing the contrast of tissue elasticity, which provides new diagnostically valuable information. To assess and improve the diagnostic performance of ultrasonic strain imaging, it is essential to have a quantitative measure of image quality. Moreover, it is useful if the image quality measure is simple to interpret and can be used for visual feedback while scanning and as a training tool for operator performance evaluation. This report describes the development of a novel quantitative method for systematic performance assessment that is based on the combination of measures of the accuracy of motion tracking and consistency among consecutive strain fields. The accuracy of motion tracking assesses the reliability of strain images. The consistency among consecutive strain images assesses the signal quality in strain images. The clinical implications of the proposed method to differentiate good or poor strain images are discussed. Results of experiments with tissue-mimicking phantoms and in vivo breast-tissue data demonstrate that the performance measure is a useful method for automatically rating elasticity image quality.  相似文献   

11.
Wall shear rate (WSR) is the derivative of blood velocity with respect to vessel radius at the endothelial cell (EC) surface. The product of WSR and blood viscosity is the wall shear stress (WSS) that has been identified as an important factor for atherosclerosis development. High echo signal-to-noise ratio (eSNR) and high spatial resolution are crucial for minimizing the errors in WSR estimates. By transmitting coded pulses with time-bandwidth product greater than one, high eSNR from weak blood scatter can be achieved without increasing instantaneous power or sacrificing spatial resolution. This paper summarizes a series of measurements in a straight tube (5-mm diameter), constant velocity flow phantom using a 10 MHz transducer (60% bandwidth, f/1.5) imaged with a 72 degrees Doppler angle, 125 MHz sampling frequency and 1 kHz pulse repetition frequency. Measurements were made using a frequency-modulated (FM) code, phase-modulated (PM) codes, and uncoded broadband and narrow band pulse transmissions. Both simulation and experimental results show that coded-pulse excitation increases accuracy and precision in WSR estimation for laminar flow over a broad range of peak velocity values when compared to standard pulsing techniques in noise-limited conditions (eSNR < 30 dB). The code sequence and its length are selected to balance range lobe suppression with eSNR and echo coherence enhancements to minimize WSR errors. In our study, the combination of an eight bit Optimal coded pulse with a Wiener compression filter yielded the highest WSR estimation performance.  相似文献   

12.
13.
Ultrasonic subaperture processing using aperture synthesis and beam space interpolation is presented. The number of beam lines scanning the image plane for a given transmit-receive subaperture combination is chosen according to the spatial sampling criteria for that combination. On each beam line, echo signals over the entire array are collected through electronic multiplexing of array channels, where the transmit subaperture at the transducer center is fired K successive times, with K equal to the number of nonoverlapping receive subapertures. For every receive subaperture, the number of beam lines is increased through digital interpolation using a linear filter with spatial frequency band associated with the subaperture. Interpolated beam lines from all receive subapertures are then added to obtain a high resolution sector image. The efficiency of subaperture processing for different system configurations is tested on experimental rf data acquired from two different phantoms using a 3.5 MHz, 128-element transducer array. The proposed subaperture processing reduces the number of firings for data acquisition, and thus allows real-time imaging with very low susceptibility to motion artifacts.  相似文献   

14.
The computational predictions for the imaging potential of the second harmonic produced by finite amplitude distortion were investigated with a simple experiment. A focused transducer containing concentric 2.5 MHz and 5.0 MHz elements was used to obtain a sequence of radio-frequency (r-f) backscattered signals using a tissue equivalent phantom. The 2.5 MHz element was used as the transmitter and the 5.0 MHz element was used as the receiver. At 0.68 cm in front of the geometric focal point of the transducer, the phantom contained a 0.6 cm diameter cylindrical volume which contained no scatterers. Each of these r-f signals was then processed to produce the corresponding fundamental (2.5 MHz-centered) and second harmonic (5.0 MHz-centered) envelopes. The contrast resolution obtained for the scatterer-free or cyst region of the envelopes was compared against the computed prediction and good agreement was obtained. The results of this experiment also suggest that the simple one-pulse scheme may be adequate for second harmonic imaging.  相似文献   

15.
高琦  周红生  王彤宇 《声学技术》2016,35(6):579-583
设计了一种超声手术刀用的新型推挽激励换能器。它是在夹心式单晶堆压电超声换能器的经典构造基础上,把原先激励一组压电陶瓷晶片堆的方式,改为同时施加反相激励的前后两组晶堆。利用有限元方法,对该推挽激励换能器进行模态分析和频率响应分析。在相同大小的电压激励下,相对单晶堆换能器,推挽激励换能器可以获得更高的工作带宽和机电耦合系数,提高了换能器的电声转换效率。按照仿真结果加工推挽激励换能器,实现良好的动力学和电学特性,满足设计要求。  相似文献   

16.
A coded source could increase the neutron flux with high L/D ratio. It may benefit a neutron imaging system with low yield neutron source. Visible light CSI experiments were carried out to test the physical design and reconstruction algorithm. We used a non-mosaic Modified Uniformly Redundant Array (MURA) mask to project the shadow of black/white samples on a screen. A cooled-CCD camera was used to record the image on the screen. Different mask sizes and amplification factors were tested. The correlation, Wiener filter deconvolution and Richardson-Lucy maximum likelihood iteration algorithm were employed to reconstruct the object imaging from the original projection. The results show that CSI can benefit the low flux neutron imaging with high background noise.  相似文献   

17.
A method for improving the contrast resolution of B-mode images is proposed by combining the speckle-reduction technique of frequency compounding (FC) and the codedexcitation and pulse-compression technique called resolution enhancement compression (REC). FC suppresses speckle but at the expense of a reduction in axial resolution. Using REC, the axial resolution and bandwidth of the imaging system was doubled. Therefore, by combining REC with FC (REC-FC), the tradeoff between axial resolution and contrast enhancement was extended significantly. Simulations and experimental measurements were conducted with a single-element transducer (f/2.66) having a center frequency of 2.25 MHz and a -3-dB bandwidth of 50%. Simulations and measurements of hyperechoic (+6 dB) tissue-mimicking targets were imaged. Four FC cases were evaluated: full-, half-, third-, and fourth-width of the true impulse response bandwidth. The image quality metrics used to compare REC-FC to conventional pulsing (CP) and CP-FC were contrast-to-noise ratio (CNR), speckle signal-to- noise ratio, histogram pixel intensity, and lesion signal-to-noise ratio. Increases in CNR of 121%, 231%, 302%, and 391% were obtained in experiments when comparing REC-FC for the full-, half-, third-, and fourth-width cases to CP. Furthermore, smaller increases in CNR of 112%, 233%, and 309% were obtained in experiments when comparing CP-FC for the half-, third-, and fourth-width cases to CP. Improved lesion detectability was observed by using REC-FC.  相似文献   

18.
Dry-contact technique for high-resolution ultrasonic imaging   总被引:1,自引:0,他引:1  
To accomplish a high-resolution ultrasonic imaging without wetting a sample, the efficiency of the dry-contact ultrasonic transmission is discussed. In this study, a dry-contact interface is formed on a sample by inserting a thin film between water and a sample, and the pressure is working on the interface by evacuating the air between the film and the sample. A model of dry-contact ultrasonic transmission is presented to assess the signal loss accompanied with the transmission. From the determination of the signal loss caused by the transmission using various films, it was found that the higher frequency ultrasound is transmitted effectively into the sample by selecting an optimum film, which can keep the displacement continuity between the film and the sample during ultrasonic transmission. Finally, ultrasonic imaging with the sufficient signal-to-noise ratio (SNR) and high lateral resolution was performed on the delamination in a package and the jointing interface of the ball-grid-array package without wetting the packages.  相似文献   

19.
The ability of pulse-echo measurements to resolve closely spaced reflectors is limited by the duration of the ultrasonic pulse. Resolution can be improved by deconvolution, but this often fails because frequency selective attenuation introduces unknown changes in the pulse shape. In this paper we propose a maximum a posteriori algorithm for simultaneous estimation of a time varying pulse and high-resolution deconvolution. A priori information is introduced to encourage estimates where the pulse varies only slowly and the reflectivity sequence is sparse. This adds sufficient regularization to the problem, and no further assumptions on the pulse such as minimum phase or a particular parametric form are needed. The joint pulse and reflectivity estimate are computed iteratively by alternating steps of pulse estimation and reflectivity estimation. The first step amounts to only a linear least squares fit. The second step is a difficult combinatorial optimization problem that we solve by a suboptimal but efficient search procedure. Due to the sparseness assumption, our approach is particularly suited for layered media containing a limited number of abrupt impedance changes. This is a situation of interest in many applications of nondestructive evaluation. Synthetic and real data results show that the algorithm works well.  相似文献   

20.
基于桥式推挽结构,设计了由两路正向单脉冲电压产生双极性电压效果的电路,提高了激励信号的能量,为超声无损检测激励电路的负向耐压低、供电电源复杂等问题提供了解决方案。该方案包括硬件实现和相关实验验证。脉冲回波检测实验结果证明:桥式推挽结构的超声激励可以提高回波的幅度,在相同实验条件下,回波幅度为单极性方波脉冲激励的两倍,等效于双极性方波脉冲激励的效果。该文方法可以提高超声激励电路的性能,为高性能便捷式超声激励系统的设计提供了理论和实验依据。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号