首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
Ejector efficiencies for the primary nozzle, suction, mixing and diffuser were determined for the first time, according to their definitions, using an axi-symmetric CFD model. Water was considered as working fluid and the operating conditions were selected in a range that would be suitable for an air-conditioner powered by solar thermal energy. Ejector performance was estimated for different nozzle throat to constant section area ratios. The results indicated the existence of an optimal ratio, depending on operating conditions. Ejector efficiencies were calculated for different operating conditions. It was found that while nozzle efficiency can be considered as constant, the efficiencies related to the suction, mixing and diffuser sections of the ejector depend on operating conditions.  相似文献   

2.
A commercial CFD code has been employed to simulate the air flow pattern and the temperature distribution in a frozen food vertical display cabinet. At first the choice of solver parameters has been investigated in a 2D modelisation. 3D simulations have been then performed, and the effects of the cabinet length, of the warm air curtain and of longitudinal ambient air movement have been investigated. The results show that, in short cabinets, 3D secondary vortices at the side walls provide the most important mechanism for hot air entrainment. Comparison with experimental results shows that a 2D simulation is totally inadequate for such configurations, while 3D computations predict refrigeration power within engineering accuracy. Furthermore, the computed refrigerating power shows that even low room air velocity, due to its interaction with the end-wall vortices, has a significant impact on cabinet performance.  相似文献   

3.
The effect of airflow blockage and guide technology on energy saving for spiral quick-freezers were investigated by simulating and analyzing the airflow field and measuring of the velocity distribution in the freezing zone for different designs. The k turbulence model was used. The velocities and temperatures of the air in the freezing zone for different designs of airflow blockage and guide boards were measured. The study shows that the airflow pattern plays a key role on energy efficiency, freezing time, and production rate. In the study case, through the optimization of the airflow blocking boards and the guide boards, the average air velocity in the freezing zone would be enhanced to 2.5–2.7 times compared with the original design. Correspondingly for bean curds in a stationary condition, the freezing time would be shortened by 78–85%, energy efficiency and the production rate would be increased by approximately 18–28% individually.  相似文献   

4.
Particle deposition on ceilings close by ventilation outlets is a well-known and bothersome problem in the ventilation industry. This paper reveals the mechanisms causing the soiling of induction outlets and offers countermeasures. Experimentally verified CFD-calculations are performed to gain insight into the processes leading to particle deposition. It shows that the room air that is being induced by the entering airflow transports particles from the room to the ceiling where they deposit due to turbulent interaction forces. Other forces such as electro- and thermophoresis are negligible. An experimental technique is proposed to visualize the soiling patterns of an outlet by photographing deposited sodium chloride crystals. These tracer-particles stem from an atomizer and aerodynamically behave like the particles responsible for the soiling of ceilings in reality. Using image processing, suitable statistics describing the tendency of an outlet to attract particles can be derived from the pictures.  相似文献   

5.
A nonintrusive flow measurement technique (particle image velocimetry) was used to determine the airflow field in a package with a container-to-product diameter ratio of less than 10. The complexity and uneven distribution of the measured flow field supported the requirement of a geometrical and mathematical model capable of describing the geometry and physics of flow within the package. Using novel computational fluid dynamics (CFD) codes, an accurate model of the packed structure was developed and the 3D Navier–Stokes equations were solved. A good agreement was obtained between experimental and predicted velocities. The detailed insight on the airflow pattern provided by the CFD analysis makes this approach an ideal tool to analyze the effect of different vent designs in the airflow field distribution in complex packaging systems.  相似文献   

6.
An ejector expansion transcritical CO2 refrigeration cycle is proposed to improve the COP of the basic transcritical CO2 cycle by reducing the expansion process losses. A constant pressure mixing model for the ejector was established to perform the thermodynamic analysis of the ejector expansion transcritical CO2 cycle. The effect of the entrainment ratio and the pressure drop in the receiving section of the ejector on the relative performance of the ejector expansion transcritical CO2 cycle was investigated for typical air conditioning operation conditions. The effect of different operating conditions on the relative performance of the ejector expansion transcritical CO2 cycle was also investigated using assumed values for the entrainment ratio and pressure drop in the receiving section of the ejector. It was found that the COP of the ejector expansion transcritical CO2 cycle can be improved by more than 16% over the basic transcritical CO2 cycle for typical air conditioning operation conditions.  相似文献   

7.
Airflow patterns in an enclosure loaded with slotted pallets   总被引:1,自引:2,他引:1  
A reduced scale model and CFD predictions are used to investigate experimentally and numerically the airflow patterns within a refrigerated truck loaded with slotted but empty pallets. Air velocity measurements are carried out on a reduced scale model with a Laser Doppler Anemometer above and inside the pallets. The numerical predictions obtained with Computational Fluid Dynamics package using the RSM turbulence model showed a satisfactory agreement with experimental data in high velocity zones. An approach was developed to evaluate the local ventilation efficiency and the fresh air within the pallets. The flow rate through the last pallet is about 35 times smaller than for the five first pallets. In terms of fresh air the difference is not so high; the equivalent fresh airflow rate through the last pallet is about six times smaller than for the first pallets.  相似文献   

8.
A multilayer two-dimensional model of beef carcass chilling using CFD-generated heat transfer coefficients was used to calculate the parameters of leg and shoulder cooling curves, assuming an exponential cooling model. A central composite experiment was designed to systematically vary air velocity, side weight and fat thickness. Comparison with experimental data suggests that the predicted characteristic time for the leg, and hence the cooling time to a given temperature, should be multiplied by a correction factor 1.07. The effects of airflow direction and of radiation heat transfer have been quantified. A correlation was proposed to estimate leg centre temperature from shoulder temperature. The shortcut formulae and methods presented here will be useful in the design and troubleshooting of industrial beef chillers. They could also be used in Monte Carlo simulations where a large number of samples are considered, to take into account random variations in product characteristics and operating conditions.  相似文献   

9.
This work deals with the assessment of the airflow in a food-processing clean room. The flow pattern inside the working area of a pilot scale clean room was numerically investigated using a computational fluid dynamics code based on a finite volume formulation. Two versions of the k- turbulence model were tested: the standard and the RNG version. The analysis of the velocity magnitude does not reveal sensitive differences between them. Moreover, both models well predict the main features of the flow and numerical results agree with experimental measurements. However, a further examination shows that the RNG k- turbulence model predicts more swirls and more complex trajectories. As the standard k- model overestimates the turbulent diffusion, the RNG version seems to be more suitable to calculate the airflow in clean rooms. The influence of initial turbulence intensity is also pointed out. Finally, the study of the airflow below a laminar flow unit confirms that the design of clean rooms can benefit from the numerical approach.  相似文献   

10.
In order to analyze the influence of the deflecting ring on the noise generated by the outdoor set of a split-unit air conditioner, the flow field in the outdoor set is simulated with the CFD software STAR-CD, the relative turbulent intensities are computed and the influence of the width and contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed. The results of computation and experiment show that there is an optimal width of the deflecting ring, corresponding to the minimum noise generated by the outdoor set. In addition, the influence of the contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed and a double contoured duct is designed. The results of computation and experiment verify that the deflecting ring with double contoured duct can improve the aerodynamic performance and reduce the noise generated by the outdoor set.  相似文献   

11.
CFD analysis of ejector in a combined ejector cooling system   总被引:5,自引:1,他引:5  
One-dimensional ejector analyses often use coefficients derived from experimental data for a set of operating conditions with limited functionality. In this study, several ejector designs were modelled using finite volume CFD techniques to resolve the flow dynamics in the ejectors. The CFD results were validated with available experimental data. Flow field analyses and predictions of ejector performance outside the experimental range were also carried out. During validation, data from CFD predicted the entrainment ratios with greater accuracy on definite area ratios, although no shock was recorded in the ejector. Predictions outside the experimental range—at operating conditions in a combined ejector–vapour compression system—and flow conditions resulting from ejector geometry variations are discussed. It is found that the maximum entrainment ratio happens in the ejector just before a shock occurs and that the position of the nozzle is an important ejector design parameter.  相似文献   

12.
Maintaining food temperatures below critical values is the key to maximising the high quality display life of chilled foods. Studies were carried out to see if computational fluid dynamic (CFD) modelling could be used to rapidly identify the changes that would be required to an existing multi-deck display cabinet so that it would meet a higher test specification. Implementing the changes on a Pastorfrigor MV 200TP display cabinet reduced the average power consumption from 1.37 to 1.29 kW as well as significantly reducing the number of test packs which spent any time above 4 °C, from 12 to 1.  相似文献   

13.
Comparison of CFD analysis to empirical data in a commercial vortex tube   总被引:3,自引:0,他引:3  
This paper presents a comparison between the performance predicted by a computational fluid dynamic (CFD) model and experimental measurements taken using a commercially available vortex tube. Specifically, the measured exit temperatures into and out of the vortex tube are compared with the CFD model. The data and the model are both verified using global mass and energy balances. The CFD model is a two-dimensional (2D) steady axisymmetric model (with swirl) that utilizes both the standard and renormalization group (RNG) k-epsilon turbulence models. While CFD has been used previously to understand the fluid behavior internal to the vortex tube, it has not been applied as a predictive model of the vortex tube in order to develop a design tool that can be used with confidence over a range of operating conditions and geometries. The objective of this paper is the demonstration of the successful use of CFD in this regard, thereby providing a powerful tool that can be used to optimize vortex tube design as well as assess its utility in the context of new applications.  相似文献   

14.
For providing good performance of dehumidifier and regenerator with certain dimensions, a new type of internally cooled/heated dehumidifier/regenerator based on the plate–fin heat exchanger (PFHE) was designed. To investigate the behavior of the new equipment, an experimental setup was established in an environment chamber with regulable temperature and humidity air. By the internally cooled dehumidification testing, effects of the cooling water temperature, the air flow rate and the desiccant temperature on the dehumidification performance and the cooling efficiency were presented. The behavior of internally cooled dehumidification process was compared with that of the adiabatic dehumidification process. The results suggested that the cooling efficiency decreased with the increasing of the cooling water temperature and desiccant with low temperature could bring more mass transfer coefficients. There is an optimal air flow rate to achieve the maximum absolute humidity decrease of the air. By the internally heated regeneration testing, effects of the air flow rate and the desiccant inlet temperature on the regeneration performance and air outlet parameters were discussed and also compared with those of the adiabatic regeneration process. It was concluded that the regeneration efficiency of internally heated regeneration was more than that of the adiabatic regeneration, and the internally heated regenerator could offer better thermal performance.  相似文献   

15.
This article presents the results of an investigation into the free cooling efficiency in a heavyweight and lightweight low energy building using a mechanical ventilation system with two latent heat thermal energy storages (LHTESs), one for cooling the fresh supply air and the other for cooling the re-circulated indoor air. Both LHTESs contain sphere encapsulated PCM (paraffin RT20). Using a developed and experimentally verified numerical model of the LHTES, the temperature response functions, based on the heat storage size, the air flow rates and the PCM's thermal properties, are established in the form of a Fourier series and empirical equations and used in the TRNSYS building thermal response model. Several mechanical ventilation, night cooling and free cooling operation modes were analysed and compared. It was found that the free cooling technique enables a reduction in the size of the mechanical ventilation system, provides more favourable temperatures and therefore enables better thermal comfort conditions, and in our studied case also fresh air for the occupants.  相似文献   

16.
Storage loss beyond permissible limit is one of the most important problems in Indian potato cold stores, which has been hindering further growth of this industry. The losses in the stored potatoes have a direct relation to the intricate coupled transport phenomena of heat, mass and momentum transfer therein. Therefore, airflow, heat transfer and moisture loss was investigated in a potato cold store of commercial scale under steady state condition using the computational fluid dynamics technique. The developed CFD model was a two-dimensional simplification of the cold store. Heat and mass transfer at the cooling coils were not modeled, instead temperature and relative humidity in the air space were specified based on measured values. The model was validated in a commercial scale cold store and was found to be capable of predicting the air velocity as well as product temperature with an average accuracy of 19.5% and 0.5 °C, respectively and also the simulated average total moisture loss was found to be only 0.61% water (w.b.) higher than the experimental one for a storage period of 6 months. The main deficiencies of the airflow pattern which resulted in wide variations in temperature and moisture loss within the stored commodity can be investigated. The model located the probable zones of hot and cold spots, excessive product dehydration and moisture condensation within the storage facility, which might lead to qualitative and quantitative deterioration in stored product. This modeling tool could very well be applied to incorporate necessary design improvements with a view to improve the airflow distribution and heat transfer in order to limit the storage losses within the permissible limit.  相似文献   

17.
Several preceding researches have evidenced that the transcritical air conditioning system using CO2 as a refrigerant has an inherent inefficiency resulting in degraded steady-state system performance of a CO2 air conditioning system compared with that of a conventional air conditioning system. As a practical improvement, two-phase ejector was considered in place of expansion device in this study. The two-phase ejector for CO2 air conditioning system was designed and developed considering the non-equilibrium state for evaluating the sonic velocity and the critical mass flux. The experiments of performance with respect to variation of ejector geometry such as the motive nozzle throat diameter, mixing section diameter and the distance between motive nozzle and diffuser were carried out. There exist optimum design parameters in each test. Experiments showed that the coefficient of performance of the system using an ejector was about 15% higher than that of the conventional system.  相似文献   

18.
Abstract

Most Thai state schools use cross flow natural ventilation as a passive cooling system. Information on how window openings are able to provide good ventilation and comfort simultaneously is of great importance. The aim of this study is to investigate cross ventilating flows through the openings of a typical Thai state school classroom. Computational fluid dynamics technique was used as a tool in this simulation. The opening discharge coefficients of six different type windows and a door were determined. Wind, stack and combined effects through the openings were characterized and compared for a range of different wind speeds and surface wall temperatures. Results showed that sliding windows gave the highest Cd value among openings considered by stack effect. Casement and side hung (90°) windows appeared to provide high air exchange rates. Their discharge coefficients ranged between 0.63 and 0.83. As far as combined effects are concerned, buoyancy was found to be significant at low wind speed (0.25 m/s). Acceptable indoor airflow patterns and thermal distributions can be expected in the occupied zone. The findings from this investigation are useful to develop a plan for a natural ventilation strategy of classrooms to enhance thermal comfort levels.  相似文献   

19.
A novel CO2 heat pump system was provided for use in fuel cell vehicles, when considering the heat exchanger arrangements. This cycle which had an inverter-controlled, electricity-driven compressor was applied to the automotive heat pump system for both cooling and heating. The cooling and heating loops consisted of a semi-hermetic compressor, supercritical pressure microchannel heat exchangers (a gas cooler and a cabin heater), a microchannel evaporator, an internal heat exchanger, an expansion valve and an accumulator. The performance characteristics of the CO2 heat pump system for fuel cell vehicles were analyzed by experiments. Results for steady and transient state performance were provided for various operating conditions. Furthermore, experiments to examine the arrangements of a radiator and an outdoor heat exchanger were carried out by changing their positions for both cooling and heating conditions. The arrangements of the radiator and the outdoor heat exchanger were tested to quantify cooling/heating effectiveness and mutual interference. The improvement of heating capacity and coefficient of performance (COP) of the CO2 heat pump system was up to 54% and 22%, respectively, when using preheated air through the radiator instead of cold ambient air. However, the cooling capacity quite decreased by 40–60% and the COP fairly decreased by 43–65%, for the new radiator-front arrangement.  相似文献   

20.
The main purpose of this study is to investigate the performance of a transcritical CO2 cycle with an internal heat exchanger for hot water heating. Performance test and simulation have been carried out for a transcritical CO2 cycle by varying secondary heat transfer fluid temperatures at evaporator and gas-cooler inlets as well as the discharge pressure. Variations of mass flow rate of refrigerant, compressor power, heating capacity, and co-efficient of performance (COP) with respect to the length of an internal heat exchanger are presented at various operating conditions. Good quantitative agreement between model predictions and experimental results has been found; most parameters have absolute average deviations of less than 4%. As the length of the internal heat exchanger increases, COP is enhanced but heating capacity tends to decrease due to the trade-offs between the effectiveness and pressure drop in the internal heat exchanger.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号