共查询到20条相似文献,搜索用时 2 毫秒
1.
A method has been developed for rapid quantification of organic acids using ultraperformance liquid chromatography/electrospray-tandem mass spectrometry (UPLC/ESI-MS-MS) to monitor the metabolism of 10 organic acids during microbial fermentation. Because comprehensive chromatographic separation is not required, analysis time is less than traditional ion chromatography assays, with complete organic acid analyses by UPLC/ESI-MS-MS being achieved in less than 3 min. Quantification is accomplished using nine isotopically labeled organic acids as internal standards. Intrasample precisions for organic acid measurements in fermentation supernatants using this method average 8.9% (RSD). Calibration curves are linear over the range of 0.06-100 microg/mL, and detection limits are estimated at 0.06-1 microg/mL. This method has the potential to demonstrate correlation of organic acid consumption and production by microorganisms with observed growth profiles, novel media formulations, and cellular growth events. Data visualization software has been used to profile organic acid levels during fermentation and correlate these profiles to nutrient supplementation protocols employed during microbial production. The potential use of this capability in computational modeling and simulation of microbial metabolism to accelerate the bioprocess development cycle is recognized. 相似文献
2.
Jaremko M Kasai Y Barginear MF Raptis G Desnick RJ Yu C 《Analytical chemistry》2010,82(24):10186-10193
Tamoxifen (Tam), the antiestrogen used to treat estrogen receptor-positive breast cancer is a pro-drug that is converted to its major active metabolites, endoxifen and 4-hydroxy-tamoxifen (4-OH-Tam) by various biotransformation enzymes of which cytochrome P450-2D6 (CYP2D6) is key. The usual Tam dose is 20 mg daily; however, the plasma active metabolite concentrations vary due to common genetic variants encoding the biotransformation enzymes and environmental factors (e.g., concomitant drugs) that inhibit these enzymes. Effective treatment depends on adequate Tam conversion to its active isomers. To monitor metabolite plasma levels, a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to separate and quantitate Tam, N-desmethyl-tamoxifen (ND-Tam), and tamoxifen-N-oxide (Tam-N-oxide), and the E, Z, and Z' isomers of endoxifen and 4-OH-Tam. Known standards were used to identify each metabolite/isomer. Quantitation of these metabolites in plasma was linear from 0.6 to 2000 nM. Intra- and inter-assay reproducibilities were 0.2-8.4% and 0.6-6.3%, respectively. Accuracy determined by spike experiments with known standards was 86-103%. Endoxifen, 4-OH-Tam, and their isomers were stable in fresh frozen plasma for ≥6 months. This method provides the first sensitive, specific, accurate, and reproducible quantitation of Tam and its metabolite isomers for monitoring Tam-treated breast cancer patients. 相似文献
3.
Hofmann U Heinkele G Angelberger S Schaeffeler E Lichtenberger C Jaeger S Reinisch W Schwab M 《Analytical chemistry》2012,84(3):1294-1301
The prodrugs azathioprine and 6-mercaptopurine, which are well-established anticancer and immunosuppressive agents, are extensively metabolized by activating and inactivating enzymes. Whereas the 6-thioguanine nucleotides (TGN) are currently being considered as major active metabolites, methylthioinosine nucleotides seem to contribute to the cytotoxic effect as well. Thiopurine-related adverse drug reactions and thiopurine failure are frequent. Thus, therapeutic monitoring of TGN and methylthioinosine derivatives has been suggested to improve thiopurine therapy, however with limited success. To elucidate systematically underlying molecular mechanisms as potential explanation for interindividual variability of thiopurine response, we developed a novel highly specific and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantitation of eleven mono-, di-, and triphosphates of thioguanosine, methylthioinosine, methylthioguanosine, and thioinosine. Using stable isotope-labeled analogues as internal standards obtained by chemical synthesis, an intra- and interassay variability below 8% and an accuracy of 92% to 107% were achieved in spiked quality control samples with known standards. All eleven metabolites could be determined in red blood cells from patients with inflammatory bowel diseases and long-term azathioprine therapy. Thus, our novel method opens a new avenue for the understanding of the thiopurine metabolism by quantitation of all important thiopurine nucleotide metabolites in one run. 相似文献
4.
The development of a quantification method for monoclonal antibodies in serum has been accomplished by high-performance liquid chromatography multiple reactions monitoring mass spectrometry. A human monoclonal antibody (HmAb) was used as the model protein for method development and validation. A peptide from the CDR3-region of its heavy chain was selected and used for quantifying the entire mAb. This signature peptide served as a template for the internal standard. Prior to mass spectrometric analysis approximately 50% of the total serum protein content was removed by albumin depletion. The accuracy of the method ranged between 99 and 112% in cynomolgus monkey serum. The intra-assay coefficient of variation (CV) was lower than 4% at 4 microg/mL and 200 microg/mL HmAb (n = 3). The CV at 400 microg/mL corresponded to 9% (n = 3). In addition, the interassay variation was investigated in a male cynomolgus serum pool and in a female cynomolgus serum pool. The CV for the male cynomolgus pool at 4 microg/mL HmAb was 7% (n = 3). The CV obtained from the female pool was 8% (n = 3), at 4 microg/mL. The dynamic range of the method was 3 orders of magnitude. After albumin depletion of 25 microL of serum, a lowest limit of quantification of 2 microg/mL HmAb was reached in both human and cynomolgus monkey samples. 相似文献
5.
Detection, confirmation, and quantification of staphylococcal enterotoxin B in food matrixes using liquid chromatography--mass spectrometry 总被引:2,自引:0,他引:2
Although immunoassay-based methods are sensitive and widely used for measuring protein toxins in food matrixes, there is a need for methods that can directly confirm the molecular identity of the toxin in situations where immunoassay tests yield a positive result. A method has been developed that uses mass spectrometry to identify a protein toxin, staphylococcal enterotoxin B (SEB), in a model food matrix, apple juice. The approach employs ultrafiltration to remove low molecular weight components from the sample, after which the remaining high molecular weight fraction, containing the protein, is digested with trypsin. The tryptic fragments are separated from residual biopolymers and analyzed by liquid chromatography-electrospray mass spectrometry. The background is still sufficiently complex that tandem mass spectrometry (MS/MS) is used to confirm the identity of target peptides. Limits of detection are 80 ng of SEB for MS and 100 ng for full scan MS/MS, using a tryptic fragment as the analytical target. Lower detection limits can be obtained using selected ion monitoring and multiple reaction monitoring. The presence of SEB can be confirmed at concentrations as low as 5 parts-per-billion by increasing the size of the sample to 10 mL. The method is applicable to the detection of SEB in other water-soluble food matrixes. 相似文献
6.
Explosives are now persistent environmental pollutants that are targets of remediation and monitoring in a wide array of environmental media. Nitroguanidine (NG) and 2,4-dinitroanisole (DNAN) are two insensitive energetic compounds recently used as munitions explosives. To protect our environment and human health, the levels of these compounds in soils and waters need to be monitored. However, no sensitive analytical methods, such as liquid chromatography-tandem mass spectrometry (LC-MS/MS), have been developed for detecting these new compounds at trace levels and to be concurrently applied to monitor the common explosives. In general, the concentrations of explosives in either soil or water samples are very low and widely distributed. Therefore, a fast and sensitive method is required to monitor those compounds and increase our ability to find and address the threats they pose to human health and ecological receptors. In this study, a fast and sensitive analytical method has been developed to quantitatively determine NG and DNAN in soil, tap water, and river water by using ultrafast LC-MS/MS. To make this method a comprehensive analytical technique for other explosives as well, it has included other commonly used explosives in the method development, such as octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), 1,3,5-trinitroper-hydro-1,3,5-triazine (RDX), 2,4,6-trinitrotoluene (TNT), 2-amino-4,6-dinitrotoluene (ADNT), and pentaerythritol tetranitrate (PETN). The method detection limits (MDLs) of these compounds in soil ranged from 0.2 to 5 ppb, and a good linearity was obtained over a concentration range of 0.5-200 ppb. The recoveries of some compounds are equal to or better than the current EPA methods but with much higher sensitivities. 相似文献
7.
A microfluidic chip that integrates all the fluidic components of a gradient liquid chromatography (LC) system is described. These chips were batch-fabricated on a silicon wafer using photolithographic processes and with Parylene as the main structural material. The fabricated chip includes three electrolysis-based electrochemical pumps, one for loading the sample and the other two for delivering the solvent gradient; platinum electrodes for delivering current to the pumps and establishing the electrospray potential; a low-volume static mixer; a column packed with silica-based reversed-phase support; integrated frits for bead capture; and an electrospray nozzle. The fabricated structures were able to withstand pressures in excess of 250 psi. The device was used to perform a liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of a mixture of peptides from the trypsin digestion of bovine serum albumen (BSA). Gradient elution through the 1.2-cm column was performed at a flow rate of 80 nL/min. Compared to the analysis of the same sample using a commercial nanoflow LC system, the chromatographic resolution was nearly as good, and the total cycle time was significantly reduced because of the minimal volume between the pumps and the column. Results demonstrate the potential of mass-produced, low-cost microfluidic systems capable of performing LC separations for proteomics applications. 相似文献
8.
9.
Detection of functional ricin by immunoaffinity and liquid chromatography-tandem mass spectrometry 总被引:1,自引:0,他引:1
The toxin ricin is a biological weapon that may be used for bioterrorist purposes. As a member of the group of ribosome-inactivating proteins (RIPs), ricin has an A-chain possessing N-glycosidase activity which irreversibly inhibits protein synthesis. In this paper, we demonstrate that provided appropriate sample preparation is used, this enzymatic activity can be exploited for functional ricin detection with sensitivity similar to the best ELISA and specificity allowing application to environmental samples. Ricin is first captured by a monoclonal antibody directed against the B chain and immobilized on magnetic beads. Detection is then realized by determination of the adenine released by the A chain from an RNA template using liquid chromatography coupled to tandem mass spectrometry. The immunoaffinity step combined with the enzymatic activity detection leads to a specific assay for the entire functional ricin with a lower limit of detection of 0.1 ng/mL (1.56 pM) after concentration of the toxin from a 500 microL sample size. The variability of the assay was 10%. Finally, the method was applied successfully to milk and tap or bottled water samples. 相似文献
10.
《福建分析测试》2020,(1):18-22
建立了直接进样-超高效液相色谱-三重四级杆串联质谱法(UPLC-MS/MS)快速测定水中苯胺和联苯胺的分析方法。样品经0.45μm聚醚砜(PES)滤膜过滤除去颗粒性杂质后,采用ACQUITY UPLC?BEH C8(1.7μm,2.1 mm×50 mm)为分离柱,甲醇-0.1%甲酸水溶液(v/v)为流动相进行梯度洗脱,电喷雾离子源(ESI)电离,多反应监测模式(MRM)进行定性和定量分析。经条件优化,苯胺和联苯胺可在3 min内分析完毕,检出限分别为0.1μg/L和0.03μg/L,且在0.2~20.0μg/L范围内线性关系良好(r> 0.999)。对3组不同浓度(0.5μg/L,2.0μg/L,5.0μg/L)加标的实际水样平行测定6次,苯胺和联苯胺的相对标准偏差在1.0%~5.4%范围内,回收率为97.6%~113%。该方法简便快捷,灵敏度高,适用于实际水样的分析。 相似文献
11.
An algorithm was developed for the computer-aided interpretation of fragment ion spectra from collision-induced dissociation of multiply charged oligodeoxynucleotide ions generated by electrospray ionization. The method compares the experimental spectrum to the m/z values predicted by employing established fragmentation pathways from a known reference sequence. The closeness of matching between the measured spectrum and the predicted set of fragment ions is characterized by the fitness, which takes into account the difference between measured and predicted m/z values, the intensity of the fragment ions, the number of fragments assigned, and the number of nucleotide positions not covered by fragment ions in the experimental spectrum. Smaller values for the fitness indicate a closer match between measured spectrum and predicted m/z values. To substantiate the identity of investigated sequence and reference sequence, or to identify point mutations or insertions/deletions, the reference sequence is systematically varied by incorporating all four possible nucleotides A, T, G, and C at each position in the sequence followed by identification of the correct sequence by the lowest fitness value. Collision energy was shown to have a major impact on the interpretability of the tandem mass spectra by the comparative sequencing algorithm, and the optimal collision energy depended on the length of the fragmented oligodeoxynucleotide. The analytical system was successfully applied to verify DNA sequences as well as to detect and localize point mutations or insertions/deletions in 5-51-mer oligodeoxynucleotides. 相似文献
12.
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening method has been developed targeting 23 pharmaceuticals and 2 metabolites with differing physicochemical properties in fish tissue. Reversed-phase separation of target compounds was achieved using a C18 column and a nonlinear gradient consisting of 0.1% (v/v) formic acid and methanol. Eluted analytes were introduced into the mass analyzer using positive or negative electrospray ionization, as appropriate. A variety of extraction solvents, differing in polarity, pH, or both, were investigated in order to assess recovery of target compounds from 1-g tissue homogenates. Among 10 solvents tested, a 1:1 mixture of 0.1 M aqueous acetic acid (pH 4) and methanol was identified as optimal, resulting in extraction recoveries for 24 of 25 compounds exceeding 60%. Tissue extracts were found to influence the LC-MS/MS response for several analytes. Consequently, matrix-matched calibration standards were employed to determine analyte concentrations in environmental samples. Statistically derived method detection limits were <6 ng/g for most analytes. The method was subsequently used to screen for target analytes in fish from an effluent-dominated stream. Diphenhydramine, diltiazem, carbamazepine, and norfluoxetine were detected in 11 of 11 environmental samples at concentrations ranging from 0.11 to 5.14 ng/g. 相似文献
13.
Eight fluorescence reagents, i.e., DBD-F, NBD-F, DNS-Cl, NDA, PSC, FITC, Fmoc-Cl, and DMEQ-COCl, which are reactive to an amino functional group, were tested for the labeling of asparaginyl-oligosaccharides in a glycoprotein. Although the optimal reaction conditions and the fluorescence maximal wavelengths were different for each reagent, the highly sensitive fluorescence detection at the femtomole level of Disialo-Asn (a representative asparaginyl-oligosaccharide) was obtained from the labeling utilizing these reagents. Among them, PSC was the most reliable reagent in terms of detection sensitivity (approximately 3 fmol, signal-to-noise ratio of 5 (S/N = 5) on the chromatogram). However, the structural information could not be obtained from the fluorescence detection. Thus, the on-line determination of a real sample was carried out by UPLC-ESI-TOF-MS. The detection limit of the PSC-labeled Disialo-Asn by selected-ion chromatography was 58 fmol (S/N = 5). When the proposed procedure was applied to the determination of oligosaccharides in ovalbumin, 15 species of PSC-labeled oligosaccharides possessing Man, GlcNAc, and Gal units were identified from the UPLC-ESI-TOF-MS. The number of identified oligosaccharides was relatively greater than the method using Fmoc-Cl. Based on the ovalbumin results, the proposed labeling with PSC followed by UPLC-ESI-TOF-MS detection seems to be useful for the on-line asparaginyl-oligosaccharide analysis. 相似文献
14.
Chenau J Fenaille F Ezan E Morel N Lamourette P Goossens PL Becher F 《Analytical chemistry》2011,83(22):8675-8682
Bacillus anthracis is one of the most dangerous agents of the bioterrorism threat. We present here a sensitive immuno-liquid chromatography-tandem mass spectrometry (immuno-LC-MS/MS) approach to spore detection in complex environmental samples. It is based on the combined specificity and sensitivity of two techniques: immunocapture and targeted mass spectrometry. The immunocapture step, realized directly on the intact spores, is essential for their selective isolation and concentration from complex environmental samples. After parallel trypsin and Glu-C digestions, proteotypic peptides corresponding to small acid-soluble spore protein-B (SASP-B) are specifically monitored in the multiple reaction monitoring (MRM) mass spectrometry mode. Peptide ratio is carefully monitored and provides an additional level of specificity, which is shown to be highly useful for distinguishing closely related samples and avoiding false-positive/negative results. Sensitivity at the level of the infectious dose is demonstrated, with limits of detection of 7 × 10(3) spores/mL of milk or 10 mg of soil. This mass spectrometry approach is thus complementary to polymerase chain reaction (PCR) techniques. 相似文献
15.
Environmental endocrine disruptors such as estrone (E1) and beta-estradiol (E2) are excreted in human urine primarily as water-soluble glucuronides and sulfates that can dissociate in wastewater treatment systems to the more active free estrogens. Measurement of the distribution and fate of the steroid conjugates and the corresponding free estrogens in treatment plants and receiving waters is critical for understanding the reproductive and developmental effects of these substances on aquatic organisms. A sensitive method to measure steroid estrogen conjugates in matrix-rich sewage influents and effluents (method detection limits ranged from 0.04 to 0.28 ng/L) has been developed using HPLC tandem mass spectrometry with electrospray ionization. The method employs extensive sample purification by selective extraction from an Oasis HLB solid-phase cartridge followed by separation by anion exchange chromatography. This purification scheme, combined with a stable isotope dilution approach, was used to overcome problems of matrix suppression of ionization and permitted selective and sensitive detection of six target conjugates of E1 and E2. Accurate quantitation was highly dependent on the method of sample preservation. Acidification of each sample (pH 2.0) was effective in preventing enzymatic or chemical decomposition of steroid conjugates in all sample types, whereas glucuronide conjugates were hydrolyzed in the presence of mercury and formalin preservatives. Measured concentrations of steroid sulfates in the influent to a sewage treatment plant were approximately 100 times greater than that of the respective steroid glucuronides, suggesting that the preponderance of glucuronides had dissociated prior to reaching the treatment plant. A small percentage of the steroid sulfates persisted through biological treatment of sewage and was measured in the effluent. Steroid conjugates that survive decomposition or bypass biological treatment of municipal wastewater are released into surface waters and may serve as a source of free steroids. 相似文献
16.
建立了液液萃取结合分散固相萃-液相色谱串联质谱(UPLC-MS/MS)技术同时测定植物油中3种复硝酚钠(5-硝基愈创木酚钠、对硝基苯酚钠、邻硝基苯酚钠)残留量的检测方法.样品经甲醇提取,C18粉净化,采用BEH C18柱(2.1 mm×100 mm,2.5μm)分离,以甲醇和水为流动相进行梯度洗脱,电喷雾负离子多反应监... 相似文献
17.
Multiclass determination of sunscreen chemicals in water samples by liquid chromatography-tandem mass spectrometry 总被引:1,自引:0,他引:1
Rodil R Quintana JB López-Mahía P Muniategui-Lorenzo S Prada-Rodríguez D 《Analytical chemistry》2008,80(4):1307-1315
A novel analytical method based on solid-phase extraction (SPE) and liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) for the determination of UV sunscreen agents in the water environment is presented. After a thorough investigation of SPE and LC-MS/MS conditions, it permits the enrichment and determination of nine of these compounds in a single methodology, including three very polar sulfonates (e.g., 2-phenylbenzimidazole-5-sulfonic acid, PBSA) and six other less polar compounds (e.g., benzophenone-3, BP-3; octocrylene, OC,...). Other important matters of concern in the determination of UV filters at trace levels in water, i.e., adsorption on glassware and blank contamination problems, have also been discussed and minimized. This methodology affords detection limits between 7 and 46 ng L-1 and SPE recoveries in the range 63-102% from different real water matrixes, except for butylmethoxydibenzoylmethane (BM-DBM), which was not determinable in wastewater samples due to adsorption problems. The application of the method allowed reporting the levels of benzophenone-4 (BP-4) in environmental water samples for the first time, where it was identified as one of the most important in concentration among the UV filters studied, particularly in wastewater (237-1481 ng L-1). 相似文献
18.
Masselon C Pasa-Tolić L Tolić N Anderson GA Bogdanov B Vilkov AN Shen Y Zhao R Qian WJ Lipton MS Camp DG Smith RD 《Analytical chemistry》2005,77(2):400-406
In proteomics, effective methods are needed for identifying the relatively limited subset of proteins displaying significant changes in abundance between two samples. One way to accomplish this task is to target for identification by MS/MS only the "interesting" proteins based on the abundance ratio of isotopically labeled pairs of peptides. We have developed the software and hardware tools for online LC-FTICR MS/MS studies in which a set of initially unidentified peptides from a proteome analysis can be selected for identification based on their distinctive changes in abundance following a "perturbation". We report here the validation of this method using a mixture of standard proteins combined in different ratios after isotopic labeling. We also demonstrate the application of this method to the identification of Shewanella oneidensis peptides/proteins exhibiting differential abundance in suboxic versus aerobic cell cultures. 相似文献
19.
20.
The advent of mass spectrometry-based metabolite profiling techniques should allow investigations into the behavior and regulation of many of the low abundant signaling molecules present in the animal metabolome such as hormones and so aid investigations into the mechanisms of endocrine system function and disorders. Examples of their potential applications include endocrine-related diseases such as some cancers, as well as endocrine disruption in wildlife and humans caused by some environmental contaminants. In the present study, a method was developed to profile a variety of vertebrate steroids and their conjugates in fish tissues using solid phase extraction (SPE) prior to ultraperformance liquid chromatography linked to electrospray-time-of-flight mass spectrometry (UPLC-TOF MS). Analysis of tissue extracts spiked with steroids revealed that most analytes could be detected at subnanogram per gram concentrations in liver or testes, but ovarian extracts caused ion suppression of estrogens. A comparison of the steroid metabolome of the ovaries and testes using partial least-squares discrimination analysis (PLS-DA) revealed that the androgens 11-ketotestosterone, 11-hydroxyandrostenedione, androstenedione, and two unidentified cortisol-type glucocorticoids were discriminatory steroid markers in testes extracts. In contrast, cortisol was the predominant glucocorticoid marker in ovary extracts, and cortisone was abundant in extracts of both testes and ovaries. A number of other unidentified nonsteroidal metabolites were also differentially expressed between the testes and ovarian tissues. These studies reveal that metabolite profiling using UPLC-TOF MS is a promising approach to investigate steroid homeostasis in animal tissues. 相似文献