共查询到20条相似文献,搜索用时 62 毫秒
1.
采用实验方法测试了三维内肋螺旋管内的流动传热性能。实验用的螺旋管曲率δ=0.0663,测试段长1.15m,试验工质为水。对螺旋光管和两种不同结构尺寸的三维内肋管进行了测试,测量的雷诺数范围约为Re=1000~8500。结果表明,三维内肋对螺旋管内的对流换热仍然有较大的强化效果,同时流阻也有一定程度的增加。与未加肋的螺旋光管相比,在测试的流动范围内,两种三维内肋管的平均换热强化比达1.71和2.03.热力性能系数为1.2~1.66。 相似文献
2.
3.
4.
不锈钢螺旋槽管水平强化传热的实验研究 总被引:4,自引:0,他引:4
本文对低导热系数的水平不锈钢螺旋槽管进行了凝结换热实验研究,并对不锈钢管的壁温测量进行了探索,通过分析得到了水平单头不锈钢螺旋槽管的水测对流换热系数准则方程。 相似文献
5.
6.
首次实验研究了制冷剂R134a在三维微肋螺旋管内流动沸腾环状流区的流动与传热性能。对流型的可视化观察发现:当质量流速大于100kg/(m^2s)时。螺旋管内才开始出现环状流。环状流的起始干度为0.3、0.4。在流型图上给出了环状流区与其它主要流型的分区。回归了实验环状流区的传热实验数据,得到的传热关联武计算值与实验值的平均绝对误差为9.1%。 相似文献
7.
8.
9.
本文阐述了肋片强化传热的原理;分析了肋片最佳形状和尺寸确定的计算式;提出了肋片在强化传热、调节壁温中的正确布置方法。 相似文献
10.
11.
The experimental study was performed on five eccentric radial heat pipes with two outer-tube diameters.The test range can be given as follows,working fluid filling ratio Ω=44%~83%,heat flux q=10000W/m2~32000W/m2,and working temperature tv=50 ℃~120 ℃.The correlations between radial heat pipe heat transfer performance and filling ratio,heat flux,working temperature were studied in the experiment.Based on linear regression of experimental data,the relationship between heat pipe equivalent heat resistance R and working temperature tv,heat flux q and filling ratio Ω was obtained. 相似文献
12.
Experimental research was conducted to understand heat transfer characteristic of pulsating heat pipe in this paper, and the PHP is made of high quality glass capillary tube. Under different fill ratio, heat transfer rate and many other influence factors, the flow patterns were observed in the start-up, transition and stable stage. The effects of heating position on heat transfer were discussed. The experimental results indicate that no annular flow appears in top heating condition. Under different fall ratios and heat transfer rate, the flow pattern in PHP is transferred from bulk flow to semi-annular flow and annular flow, and the performance of heat transfer is improved for down heating case. The experimental results indicate that the total heat resistant of PHP is increased with fill ratio, and heat transfer rate achieves optimum at filling rate 50%. But for pulsating heat pipe with changing diameters the thermal resistance is higher than that with uniform diameters. 相似文献
13.
14.
15.
基于航空航天等领域对环路热管长距离传热的需求,设计制造了一套传热距离8.1m的圆柱型蒸发器环路热管,试验了不同加热功率、不同冷凝温度下该环路热管的启动和变工况运行性能,并对其热阻及最大传热能力进行了分析。研究结果表明:当其他条件一致、初始气液分布相同和不同时,加热功率由100W增大至160W后,本研究中的环路热管启动时间和启动温升均发生一定程度的下降;加热功率100W时,冷凝温度由10℃降低至-10℃使得环路热管启动时间增加,加热功率160W时,冷凝温度由10℃降至-10℃对环路热管的启动时间影响不大。在冷凝温度0℃下,该环路热管在100~500W范围内均能稳定运行,且200W时环路热管传热效率最高,传热温差最小,稳定运行温度最低;另外,由于系统传输距离较长,每个工况达到稳定所需要的时间也较长,分布于1000至3500S内。随着加热功率的增大,环路热管热阻先减小后逐渐增大,该环路热管传热热阻最大不超过0.09℃/W,最小为0.024℃/W;随着传热距离的增大,管路的热损失增加,总压降和热阻也变大。当传热距离基本相同时,蒸发器容积的大小、冷凝器的冷凝能力及气液管线的布置形状均在一定程度上影响环路热管的最大传热能力。 相似文献
16.
Yoshihiro Iida Toshikatsu Tsuyuki Takao Mashima Takeo Takashima Kunito Okuyama 《亚洲传热研究》2002,31(1):28-41
This paper presents a series of experimental results on a passive augmentation technique of boiling heat transfer by supplying solid particles in liquid. A cylindrical heater 0.88 mm in diameter is placed in saturated water, in which a lot of mobile particles exist, and the nucleate and film boiling heat transfer characteristics are measured. Particle materials used were alumina, glass, and porous alumina, and the diameter ranged from 0.3 mm to 2.5 mm. Particles are fluidized by the occurrence of boiling without any additive power, and the heat transfer is augmented. The maximum augmentation ratio obtained in this experiment reaches about ten times the heat transfer coefficient obtained in liquid alone. The augmentation ratio is mainly affected by the particle material, diameter, and the height of the particle bed set at no boiling condition. The augmentation mechanism is discussed on the basis of the experimental results. © 2001 Scripta Technica, Heat Trans Asian Res, 31(1): 28–41, 2002 相似文献
17.
Longjian Li Quan Liao Tien-Chien Jen Qinghua Chen 《International Journal of Heat and Mass Transfer》2005,48(10):1916-1925
Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in the smooth helical tube, the boiling heat transfer coefficient in the 3D internally micro-finned helical tube is increased by 40-120% under varied mass flow rate and wall heat flux conditions, meanwhile, the flow resistance is increased by 18-119%, respectively. 相似文献
18.
19.
通过实验研究四氧化三铁(Fe3O4)纳米流体重力热管的传热性能。在不同输入功率、不同充液率、不同纳米流体质量浓度的工况下测试热管的外壁温度,再理论计算其等效对流传热系数、热阻。结果表明:当充液率为50%,输入功率为40W时,水基液重力热管和纳米流体重力热管都有最高的等效对流传热系数,并且纳米流体质量浓度为1%时,重力热管具有最高的等效对流传热系数5455.4 W.m-2.K-1,较水基液重力热管最多可增大79.1%。四氧化三铁纳米流体运用于重力热管可以有效减小其热阻、强化其传热性能。 相似文献