首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Proteomics is the study of all proteins in a biological sample. High-pressure liquid chromatography coupled online with mass spectrometry (HPLC/MS) is currently the method of choice for proteomic analysis. Proteins are extracted, separated at the protein or peptide level (after enzymatic digestion), and fractions are analyzed by HPLC/MS. Detection during off-line fractionation is generally conducted using UV-vis, which is not sensitive enough to distinguish fractions having the largest concentration of proteins/peptides and should not be combined prior to HPLC/MS. To overcome this deficiency, we utilize fluorescence or UV-laser induced fluorescence (UV-LIF) detection for measuring proteins/peptides during the off-line fractionation. Fluorescence detection allows low-abundance proteins/peptides that contain aromatic amino acids to be measured. In this study, peptide/protein samples fractionated using ion-exchange chromatography were detected using UV absorbance, fluorescence, and UV-LIF. The results indicated that fluorescence and UV-LIF were able to detect the lower abundance proteins/peptides to give a more representative chromatogram, allowing the analyst to decide which fractions should be combined prior to HPLC/tandem mass spectrometry (MS/MS) analysis.  相似文献   

2.
Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increase sample throughput, we have developed a novel in-gel digestion protocol where sample preparation is performed directly on a MALDI probe with prestructured sample support. The protocol consists of few sample-handling steps and has minimal consumption of reagents, making the protocol sensitive, timesaving, and cost-efficient. Performance of the on-probe sample preparation protocol was demonstrated by analysis of a set of rat liver proteins obtained from a fluorescently stained (Cy3 and SyproRuby) two-dimensional polyacrylamide gel. The success rate of protein identification by on-probe tryptic digestion and MALDI peptide mass mapping was 89%. The on-probe in-gel digestion procedure provided superior sensitivity and peptide mass mapping performance as compared to our standard in-gel digestion protocol. The on-probe digestion technique resulted in significantly improved amino acid sequence coverage of proteins, mainly due to efficient recovery and detection of large (>1.5 kDa) hydrophobic peptides. These observations indicate that numerous tryptic peptides are lost when using the standard in-gel digestion methods and sample preparation techniques for MALDI MS. This study also demonstrates that the on-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications.  相似文献   

3.
Identification of individual proteins in complex protein mixtures by high-resolution (HR), high-mass-accuracy matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOF-MS) is demonstrated for synthetic protein mixtures. Instead of chemical denaturation, thermal denaturation followed by in-solution trypsin digestion is used to achieve uniform digestion of the constituents of the protein mixture. Protein identification is carried out using protein database searches with search scoring systems, which seems more effective than conventional peptide mass mapping without using a scoring system. Identification of individual proteins by MALDI HR-TOF-MS peptide mass mapping dramatically reduces data acquisition/analysis time and does not require special equipment for sample preparation/transfer prior to mass spectral analysis.  相似文献   

4.
Lin S  Yao G  Qi D  Li Y  Deng C  Yang P  Zhang X 《Analytical chemistry》2008,80(10):3655-3665
A fast and efficient proteolysis approach of microwave-assisted protein digestion was developed by using trypsin-immobilized magnetic silica (MS) microspheres. In the work, immobilization of the enzyme onto MS microspheres was very simple and only through a one-step reaction with 3-glycidoxypropyltrimethoxysilane (GLYMO) which provides the epoxy group as a reactive spacer. Considering that the magnetic particles are excellent microwave absorbers, we developed a novel microwave-assisted digestion method based on the easily prepared trypsin-immobilized MS microspheres. This novel digestion method combined the advantages of immobilized trypsin and the rapid-fashion of microwave-assisted digestion, which resulted in high digestion efficiency. BSA and myoglobin were used as model proteins to optimize the conditions of this method. Peptide fragments produced in 15 s could be confidently identified by matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) analysis. Equivalent or better digestion efficiency was observed comparing to current in-solution digestion. Besides, because of the unique magnetic responsivity, the immobilized trypsin can be isolated easily with the help of an external magnet and thus used repeatedly. High activity was obtained even after seven runs of the trypsin-immobilized MS microspheres. To further verify its efficiency in proteome analysis, one reversed-phase liquid chromatography (RPLC) fraction of rat liver extract was applied. After 15 s incubation, 16 totally unique peptides corresponding to two proteins were identified. Finally, the rat liver sample was used to evaluate its worth for the application. With analysis by liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS), comparable digestion efficiency was observed with typical in-solution digestion but the incubation time was largely shortened. This new microwave-assisted digestion method will hasten the application of the proteome technique to biomedical and clinical research.  相似文献   

5.
High-efficiency capillary isoelectric focusing of peptides   总被引:6,自引:0,他引:6  
Several approaches are presently being developed for global proteome characterization that are based upon the analysis of polypeptide mixtures resulting from digestion of (often complex) mixtures of proteins. Improved methods for peptide analysis are needed that provide for sample concentration, higher resolution separations, and direct compatibility with mass spectrometry. In this work, methods for the high-efficiency capillary isoelectric focusing (CIEF) separation of peptides have been developed that provide for simultaneous sample concentration and separation according to peptide isoelectric point. Under typical nondenaturing CIEF conditions, peptides are concentrated approximately 500-fold, and peptides present at < 1 ng/ microL were detectable using conventional UV detection. CIEF separations of peptides provided much faster measurements of isoelectric points compared with conventional isoelectric focusing in gels. Very small differences in peptide isoelectric points (deltapI approximately 0.01) could be resolved, High-efficiency CIEF separations for complex peptide mixtures from tryptic digestion of yeast cytosol fractions were obtained and showed significant improvement over those obtained using capillary zone electrophoresis and packed capillary reversed-phase liquid chromatography.  相似文献   

6.
Liquid chromatography coupled on- or off-line with mass spectrometry is rapidly advancing as a tool in proteomics capable of dealing with the inherent complexity in biology and complementing conventional approaches based on two-dimensional gel electrophoresis. Proteins can be identified by proteolytic digestion and peptide mass fingerprinting or by searching databases using short-sequence tags generated by tandem mass spectrometry. This paper shows that information on the chromatographic behavior of peptides can assist protein identification by peptide mass fingerprinting in liquid chromatography/mass spectrometry. This additional information is significant and already available at no extra experimental cost.  相似文献   

7.
Although LC-MS methods are increasingly used for the absolute quantification of proteins, the lack of appropriate internal standard (IS) hinders the development of rapid and standardized analytical methods for both in vitro and in vivo studies. Here, we have developed a novel method for the absolute quantification of a therapeutic protein, which is monoclonal antibody (mAb). The method combines liquid chromatography tandem mass spectrometry (LC-MS/MS) and protein cleavage isotope dilution mass spectrometry with the isotope-labeled mAb as IS. The latter was identical to the analyzed mAb with the exception that each threonine contains four (13)C atoms and one (15)N atom. Serum samples were spiked with IS prior to the overnight trypsin digestion and subsequent sample cleanup. Sample extracts were analyzed on a C18 ACE column (150 mm x 4.6 mm) using an LC gradient time of 11 min. Endogenous mAb concentrations were determined by calculating the peak height ratio of its signature peptide to the corresponding isotope-labeled peptide. The linear dynamic range was established between 5.00 and 1000 microg/mL mAb with accuracy and precision within +/-15% at all concentrations and below +/-20% at the LLOQ (lower limit of quantification). The overall method recovery in terms of mAb was 14%. The losses due to sample preparation (digestion and purification) were 72% from which about 32% was due to the first step of the method, the sample digestion. This huge loss during sample preparation strongly emphasizes the necessity to employ an IS right from the beginning. Our method was successfully applied to the mAb quantification in marmoset serum study samples, and the precision obtained on duplicate samples was, in most cases, below 20%. The comparison with enzyme-linked immunosorbent assay (ELISA) showed higher exposure in terms of AUC and Cmax with the LC-MS/MS method. Possible reasons for this discrepancy are discussed in this study. The results of this study indicate that our LC-MS/MS method is a simple, rapid, and precise approach for the therapeutic mAb quantification to support preclinical and clinical studies.  相似文献   

8.
Dai J  Shieh CH  Sheng QH  Zhou H  Zeng R 《Analytical chemistry》2005,77(18):5793-5799
A novel integrated multidimensional liquid chromatography (IMDL) method is demonstrated for the separation of peptide mixtures by two-dimensional HPLC coupled with ion trap mass spectrometry. The method uses an integrated column, containing both strong cation exchange and reversed-phase sections for two-dimensional liquid chromatography. The peptide mixture was fractionated by a pH step using a series of pH buffers, followed by reversed-phase chromatography. Since no salt was used during separation, the integrated multidimensional liquid chromatography can be directly connected to mass spectrometry for peptide analysis. The pH buffers were injected from an autosampler, and the entire process can be carried out on a one-dimensional liquid chromatography system. In a single analysis, the IMDL system, coupled with linear ion trap mass spectrometry, identified more than 2000 proteins in mouse liver. The peptides were eluted according to their pI distribution. The resolution of the pH fractionation is approximately 0.5 pH unit. The method has low overlapping across pH fractions, good resolution of peptide mixture, and good correlation of peptide pIs with pH steps. This method provides a technique for large-scale protein identification using existing one-dimensional HPLC systems.  相似文献   

9.
Y Du  F Wang  K May  W Xu  H Liu 《Analytical chemistry》2012,84(15):6355-6360
The sites and levels of Asn deamidation in proteins are often determined by LC-MS analysis of peptides obtained from enzymatic digestion. However, deamidation that occurs during sample preparation steps results in overestimation of the original level of deamidation. The inherent deamidation and those introduced by sample preparation can be differentiated by preparing samples in (18)O water. When using H(2)(18)O, the formation of isoAsp and Asp by Asn deamidation during sample preparation results in a molecular weight increase of 3 Da due to the incorporation of the (18)O atom to the side chains of isoAsp or Asp; in contrast, inherent deamidation only results in a molecular weight increase of 1 Da. In addition, up to two (18)O atoms can also be incorporated into the peptide C-terminal carboxyl group during enzymatic digestion. Therefore, the 2 Da molecular weight difference at the deamidation sites can only be used to differentiate deamidation that occurs prior to or during sample preparation under conditions that a fixed number of (18)O atoms are incorporated into the peptide C-terminal carboxyl groups. Otherwise, it is challenging to apply this procedure because of the resulting complicated isotopic distributions. Here, a new procedure of using (18)O-water for sample preparation coupled with tandem mass spectrometry (MS/MS) was established to calculate the deamidation artifacts. In this method, b ions were used for the calculation of Asn deamidation that occurred prior to or during sample preparation, which eliminated the complicated factor of various number of (18)O-atoms to the peptide carboxyl groups. This procedure has the potential to be applied under the general peptide mapping conditions.  相似文献   

10.
We report an efficient, high fidelity trypsin digestion method for peptide map analysis. This method minimizes artifacts caused by the sample preparation process, and we show its utility for the accurate determination of succinimide formation in a degraded monoclonal antibody product. A basic charge variant was detected by imaged capillary isoelectric focusing and was shown with reduced antigen binding and biological activity. Samples were reduced under denaturing conditions at pH 5.0, and digestion of the reduced protein with porcine trypsin was performed at pH 7.0 for 1 h. Following reversed phase high-performance liquid chromatography and online mass spectrometric analysis, succinimide formation was identified at Asp30 in the light chain. This result contrasts with the observation of only iso-Asp and Asp residues under conventional sample preparation conditions, which are therefore concluded to be artificially generated. The Asp30 residue is seen in the cocrystal structure model to participate in favorable charge interaction with an antigen molecule. Formation of succinimide and the resulting loss of negative charge are therefore hypothesized to be the degradation mechanism. After treatment of the degraded antibody sample to mildly alkaline pH conditions, we observed only Asp residue as the succinimide hydrolysis product and concurrent recovery of biological activity.  相似文献   

11.
The practice of quantifying proteins by peptide fragments from enzymatic proteolysis (digestion) was assessed regarding accuracy, reliability, and uncertainty of the results attainable. Purified recombinant growth hormone (rhGH, 22 kDa isoform) was used as a model analyte. Two tryptic peptides from hGH, T6 and T12, were chosen to determine the amount of the protein in the original sample. Reference solutions of T6 and T12 (isotopically labeled forms), value assigned by quantitative amino acid analysis (AAA) after complete hydrolysis, were used as internal standards. The accuracy of protein quantification by fragments T6 and T12 was evaluated by comparison of peptide results to those obtained for the same rhGH sample by AAA. The rate of cleavage (and thus the experimental protocol used) turned out to be crucial to the quality of results in protein quantification using enzymatic fragments. Applying a protocol customarily found in (qualitative) bottom-up proteomics gave results significantly higher than the target value from AAA (+11% with T6 and +6% with T12). In contrast, using a modified protocol optimized for fast and complete hydrolysis, results were unbiased within the limits of uncertainty, while the time needed for completion of proteolysis was considerably reduced (30 min as compared to 1080-1200 min). The method assessed highlighted three important criteria deemed necessary for successful protein quantification using proteolysis-based mass spectrometry methods. These are the following: the requirement for both the selected peptides and labeled internal standard to be stable throughout digestion; the correct purity assignment to the selected peptide standards; the proof of equimolar release of the selected peptides. The combined (overall) uncertainty for protein quantification was established by combination of estimates obtained for individual components and found to be U = 4% for this example. This uncertainty is of the same order as that typically attainable in quantification of "small" organic molecules using liquid chromatography/isotope dilution mass spectrometry.  相似文献   

12.
The castor bean plant (Ricinus communis) is used in large quantities for oil production and is also a common ornamental garden plant. However, the beans contain 1-3% of the highly toxic protein ricin, a type II ribosome-inactivating protein that is covered by the Chemical Weapons Convention, and there have been a number of reports concerning the use, or alleged use, of the toxin in terrorist and criminal activities. In the study reported here, we investigated the potential utility of organic solvent-assisted trypsin digestion of crude extracts containing the closely related toxins ricin or abrin to prepare samples for peptide analysis by liquid chromatography combined with electrospray ionization quadrupole time-of-flight tandem mass spectrometry. Diagnostic tryptic fragments of the toxins were detected and unambiguously identified by this procedure. The sample preparation protocol substantially reduces the sample preparation time, from overnight to an hour, and thus greatly reduces the total time required for analyses, to less than 2 h. Furthermore, the reported procedure leaves the disulfide bonds in the protein intact. This is highly relevant in the context of the Chemical Weapons Convention, since the disulfide bond connecting the two chains of ricin indicates the presence of an intact toxin and provides additional forensic evidence for the analytical results.  相似文献   

13.
A simple and reliable method is described here for the identification and relative quantification of proteins in complex mixtures using two-dimensional liquid chromatography/tandem mass spectrometry. The method is based on the classical proteomic analysis where proteins are digested with trypsin and the resulting peptides are separated by multidimensional liquid chromatography. The separated peptides are analyzed by tandem mass spectrometry and identified via a database search algorithm such as SEQUEST. The peak areas (integrated ion counts over the peptide elution time) of all identified peptides are calculated, and the relative concentration of each protein is determined by comparing the peak areas of all peptides from that protein in one sample versus those from the other. Using this strategy, we compared the relative level of protein expression of A431 cells (an epidermal cell line) grown in the presence or absence of epidermal growth factor (EGF). Our results are consistent with the published observations of the transient effects of EGF. In addition, the difference in the concentrations of several phosphopeptides determined in our studies suggests the possibility of several new targets involved in the EGF cell-signaling pathway. This global protein identification and quantification technology should prove to be a valuable means for comparing proteomes in biological samples subjected to differential treatments.  相似文献   

14.
A method is developed to integrate a protein separation by monolithic capillary reversed-phase high-performance liquid chromatography to on-probe tryptic digestion for subsequent analyses by MALDI-TOF MS and MALDI-TOF/TOF MS. The method provides a means of directly interfacing separations to MALDI-MS, reducing the amount of time required for traditional procedures involving in-solution enzymatic digestion and sample cleanup prior to MALDI-MS analysis. When used with pI-based fractionation as a first dimension, it provides a means of analyzing complex mixtures of proteins with minimal sample handling and cleanup. The use of monolithic capillary columns sufficiently resolved intact proteins so that peptide mass fingerprinting analysis by MALDI-TOF MS resulted in the identification of close to 40 unique proteins from 120 ng of sample obtained from a prefractionated MCF10 cell line at pH 6.34, where the identifications of several of these proteins were also confirmed by intact MW and tandem mass spectrometric analysis. The reproducibility of this method has been demonstrated to be sufficient for the purpose of protein identifications. Experimental values of protein intact MW are obtained and compared to that expected for each protein identified.  相似文献   

15.
We describe an automated method for shotgun proteomics named multidimensional protein identification technology (MudPIT), which combines multidimensional liquid chromatography with electrospray ionization tandem mass spectrometry. The multidimensional liquid chromatography method integrates a strong cation-exchange (SCX) resin and reversed-phase resin in a biphasic column. We detail the improvements over a system described by Link et al. (Link, A. J.; Eng, J.; Schieltz, D. M.; Carmack, E.; Mize, G. J.; Morris, D. R.; Garvik, B. M.; Yates, J. R., III. Nat. Biotechnol. 1999, 17, 676-682) that separates and acquires tandem mass spectra for thousands of peptides. Peptides elute off the SCX phase by increasing pI, and elution off the SCX material is evenly distributed across an analysis. In addition, we describe the chromatographic benchmarks of MudPIT. MudPIT was reproducible within 0.5% between two analyses. Furthermore, a dynamic range of 10000 to 1 between the most abundant and least abundant proteins/peptides in a complex peptide mixture has been demonstrated. By improving sample preparation along with separations, the method improves the overall analysis of proteomes by identifying proteins of all functional and physical classes.  相似文献   

16.
Measuring dynamics of proteins abundance in cells in response to stimuli such as growth factors or drugs requires analysis of more than one time point. Proteomic approaches have traditionally been used to measure only one state at a time because quantitation is difficult, especially when mass spectrometry is used as a readout. Isotopically labeled reagents have recently been introduced that allow comparison of two or three different states by mass spectrometry. Here, we evaluate the reproducibility of an experiment that measures three states simultaneously through stable isotope labeling of cells with amino acids in cell culture (SILAC) using light, medium, and heavy versions of amino acids. The major goal of this study was to assess the reproducibility of such experiments in combination with liquid chromatography tandem mass spectrometry (LC-MS/MS). Our results show that it is possible to obtain reproducible quantitative data to study protein dynamics based on our analysis of more than 220 peptide sets derived from 20 proteins from 3 different LC-MS/MS runs.  相似文献   

17.
Gao J  Xu J  Locascio LE  Lee CS 《Analytical chemistry》2001,73(11):2648-2655
An integrated platform is presented for rapid and sensitive protein identification by on-line protein digestion and analysis of digested proteins using electrospray ionization mass spectrometry or transient capillary isotachophoresis/capillary zone electrophoresis with mass spectrometry detection. A miniaturized membrane reactor is constructed by fabricating the microfluidic channels on a poly(dimethylsiloxane) substrate and coupling the microfluidics to a poly(vinylidene fluoride) porous membrane with the adsorbed trypsin. On the basis of he large surface area-to-volume ratio of porous membrane media, adsorbed trypsin onto the poly(vinylidene fluoride) membrane is employed for achieving ultrahigh catalytic turnover. The extent of protein digestion in a miniaturized membrane reactor can be directly controlled by the residence time of protein analytes inside the trypsin-adsorbed membrane, the reaction temperature, and the protein concentration. The resulting peptide mixtures can either be directly analyzed using electrospray ionization mass spectrometry or further concentrated and resolved by electrophoretic separations prior to the mass spectrometric analysis. This microfluidic system enables rapid identification of proteins in minutes instead of hours, consumes very little sample (nanogram or less), and provides on-line interface with upstream protein separation schemes for the analysis of complex protein mixtures such as cell lysates.  相似文献   

18.
A combinatory approach for the characterization of post-translational and chemical modifications in high molecular weight therapeutic proteins like antibodies and peptide-Fc fusion proteins (MW > or = 50 000 Da) is presented. In this approach, well-established techniques such as limited proteolysis, reversed-phase (RP) high-performance liquid chromatography (HPLC), and in-line mass spectrometry (MS) were combined for the characterization of a monoclonal IgG1 antibody and three different peptide-Fc fusion proteins. The one commonality of these molecules is the presence of a similarly accessible lysine residue either located in the flexible hinge region of the antibody or in the flexible linker of the peptide-Fc fusion proteins. Applying limited proteolysis using endoproteinase Lys-C resulted in the predominant cleavage C-terminal of this lysine residue. The created fragments, two identical Fab domain fragments and one Fc domain fragment derived from the IgG1 antibody and one Fc domain fragment and each of the three individual peptide moieties generated from the peptide-Fc fusion proteins, were readily accessible for complete separation by RP-HPLC and detailed characterization by in-line MS analysis. This approach facilitated rapid detection of a variety of chemical modifications such as methionine oxidation, disulfide bond scrambling, and reduction as well as the characterization of various carbohydrate chains. We found limited proteolysis followed by RP-HPLC-MS to be less time-consuming for sample preparation, analysis, and data interpretation than traditional peptide mapping procedures. At the same time, the reduced sample complexity provided superior chromatographic and mass spectral resolution than the analysis of the corresponding intact molecules or a large number of enzymatically generated fragments.  相似文献   

19.
Acetylation of proteins on specific lysine residues by acetyltransferase enzymes is a post-translational modification for biologically relevant regulation. In this study, we proposed a strategy to determine the in vitro acetylation sites of proteins by tracing isotope-labeled acetyl groups using mass spectrometry. Isotope-labeled and unlabeled acetyl groups transferred onto the substrates in vitro result in a specific "mass difference" that can be measured by MS analysis and utilized for localization of potential acetylated peptide signals. The identification of acetylation site is facilitated by conducting MS/MS experiments on those selected signals. Acetylation reactions of substrates were performed in the presence of acetyltransferase and equal molar of isotope-labeled acetyl coenzyme A ([(13)C2-2-D3]-acetyl-CoA) and unlabeled acetyl-CoA. After enzymatic digestion, the resulting peptide mixture was fractionated by off-line, reversed-phase high-pressure liquid chromatography and the accurate mass measurement of peptides was achieved by a quadrupole/time-of-flight mass spectrometer. Signals with 5-Da (or their multiples) mass differences and equal responses were selected out by program computation. Those potential acetylated peptide signals were subjected to MS/MS analyses for determination of acetylation sites. We have used histone H3 peptide (aa 1-20), histone H2B peptide (aa 1-21), histone H2A, and histone H2B proteins as the model compounds to demonstrate the applicability of this analytical scheme for the characterization of in vitro acetylation sites.  相似文献   

20.
To fully automate the sample introduction step for nanoscale microcapillary liquid chromatography-tandem mass spectrometry (LC-MS/MS) analyses, 75 microm i.d. x 14 cm capillary columns were interfaced with a commercial autosampler instrument using a novel procedure which allowed dilute peptide samples to be transferred from the AS loop injector to the nanoscale column at flow rates up to 5 microL min(-1). On-column enrichment and desalting was demonstrated for large sample volumes (>40 microL) by constructing a vent 2 cm after the entrance to the packed bed of 5-microm ODS-AQ modified silica. Salts and nonretained solutes were removed via the vent, which allowed for column washing independent of the continuation of the bed into the electrospray source. Separations of test peptide mixtures demonstrated 50-nL elution peak volumes with low- to subfemtomole detection levels. In addition, a highly complex peptide mixture (outer membrane preparation from Psuedemonas aeruginosa) was efficiently separated with more than 100 proteins identified from a single reversed-phase LC-MS/MS analysis. Finally, the vented column (V-column) was utilized for on-line separations in a multidimensional chromatography/tandem MS experiment where large numbers of strong cation exchange chromatography fractions from a trypsinized yeast lysate were desalted, concentrated, and analyzed in a completely automated fashion. The procedures for constructing and using a V-column require minimal changes in current methods and equipment for nano-LC-MS analyses using columns of 100-microm diameter and smaller.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号