首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper 1-ethyl-3-methylimidazolium tetrafluoroborate based carbon ionic liquid electrode (CILE) was fabricated and further modified with chitosan (CTS) and graphene (GR) composite film. The fabricated CTS-GR/CILE was further used for the investigation on the electrochemical behavior of bisphenol A (BPA) by cyclic voltammetry and differential pulse voltammetry. A well-defined anodic peak appeared at 0.436 V in 0.1 mol/L pH 8.0 Britton-Robinson buffer solution, which was attributed to the electrooxidation of BPA on the modified electrode. The electrochemical parameters of BPA on the modified electrode were calculated with the results of the charge transfer coefficient (α) as 0.662 and the apparent heterogeneous electron transfer rate constant (ks) as 1.36 s− 1. Under the optimal conditions, a linear relationship between the oxidation peak current of BPA and its concentration can be obtained in the range from 0.1 μmol/L to 800.0 μmol/L with the limit of detection as 2.64 × 10− 8 mol/L (3σ). The CTS-GR/CILE was applied to the detection of BPA content in plastic products with satisfactory results.  相似文献   

2.
In this paper a graphene (GR) modified carbon ionic liquid electrode that was obtained by one-step potentiostatic electroreduction of a graphene oxide solution was described. The resulting electrode displayed excellent electrochemical performance due to the formation of highly conductive GR film on the electrode surface. Electrochemistry of rutin was carefully studied with a pair of well-defined redox peaks appeared in pH 2.5 buffer solution. Rutin exhibited a diffusion-controlled two-electron and two-proton transfer reaction on the modified electrode with the electrochemical parameters calculated. The reduction peak currents are linearly related to rutin concentration in the concentration range from 0.070 to 100.0 μmol/L with a detection limit as low as 24.0 nmol/L (3σ). The modified electrode displayed excellent selectivity with good stability, and was applied to the determination of rutin content in tablet, human serum and urine samples with satisfactory results.  相似文献   

3.
Journal of Materials Science - In this work, rGO-ZnO (reduced graphene oxide–zinc oxide) nanocomposite was prepared and used for modification of GC (glassy carbon) surface in order to obtain...  相似文献   

4.
A novel multiwall carbon nanotubes (MWCNTs) modified carbon ionic liquid electrode (CILE) was fabricated and used to investigate the electrochemical behavior of norepinephrine (NP). MWCNTs/CILE was prepared by mixing hydrophilic ionic liquid, 1-methyl-3-butylimidazolium bromide (MBIDZBr), with graphite powder, MWCNTs, and liquid paraffin. The fabricated MWCNTs/CILE showed great electrocatalytic ability to the oxidation of NE. The electron transfer coefficient, diffusion coefficient, and charge transfer resistant (Rct) of NE at the modified electrode were calculated. Differential pulse voltammetry of NE at the modified electrode exhibited two linear dynamic ranges with slopes of 0.0841 and 0.0231 μA/μM in the concentration ranges of 0.3 to 30.0 μM and 30.0 to 450.0 μM, respectively. The detection limit (3σ) of 0.09 μM NP was achieved. This modified electrode exhibited a good ability for well separated oxidation peaks of NE and acetaminophen (AC) in a buffer solution, pH 7.0. The proposed sensor was successfully applied for the determination of NE in human urine, pharmaceutical, and serum samples.  相似文献   

5.
In the present paper, a novel benzoylferrocene (BF) modified carbon nanotube paste electrode (BFCNPE) was prepared. The modified electrode was further used for the successful determination of N-acetylcysteine (NAC), and it showed an excellent electrocatalytic oxidation activity toward NAC with a lower overvoltage, pronounced current response, and good sensitivity. Under the optimized experimental conditions, the proposed electrochemical NAC sensor exhibited a linear calibration plot that ranged from 3.0 × 10? 7 to 7.0 × 10? 4 M with a detection limit of 9.0 × 10? 8 M. Also, Square wave voltammetry (SWV) was used for simultaneous determination of NAC and folic acid (FA) at the modified electrode. Finally, the proposed method was applied to the determination of NAC in NAC tablets.  相似文献   

6.
This paper describes the development of 1-methyl-3-butylimidazolium chloride ionic liquid/cobalt hexacyanoferrate nanoparticle modified multi-walled carbon nanotubes nanocomposite paste electrode for the electrocatalytic and adsorptive stripping voltammetric and impedimetric determination of diclofenac (DIC) in real samples. The nanocomposite was prepared by a simple chemical method and was characterised by scanning electron microscopy, Fourier transform infrared spectroscopy and atomic absorption spectroscopy. Also, the electrochemical behaviours of the modified electrode and the electrocatalytic oxidation of DIC were investigated in detail by cyclic voltammetry, chronoamperometry and electrochemical impedance spectroscopy techniques. The kinetic parameters such as electron transfer coefficient, and apparent rate constant for the redox reaction between DIC and the modified electrode were also determined using electrochemical approaches. It was found that the modified electrode exhibited excellent electrocatalytic activity toward the oxidation of DIC, and under the optimised conditions, the linear response range and detection limit were found to be 1.0–100.0 and 0.3 μM, respectively using the differential pulse voltammetry method. The proposed method was applied for the sensitive and selective determination of diclofenac in the urine samples and pharmaceutical formulations with satisfactory results.  相似文献   

7.
This paper describes the development and utilization of a new nanocomposite consisting of Cu(OH)2 nanoparticles, hydrophobic ionic liquid 1-ethyl-3-methylimidazolium hexafluorophosphate (EMIMPF6) and multiwalled carbon nanotubes for glassy carbon electrode modification. The nanocomposite was characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM) along with energy-dispersive X-ray spectroscopy (EDX). The modified electrode was used for electrochemical characterization of diclofenac. Using differential pulse voltammetry, the prepared sensor showed good sensitivity and selectivity with low overpotential for the determination of diclofenac in the range from 0.18 to 119 μM, with a detection limit of 0.04 μM. Electrochemical studies suggested that the MWCNTs/Cu(OH)2 nanoparticles/IL nanocomposite modified electrode provided a synergistic augmentation on the voltammetric behavior of electrochemical oxidation of diclofenac, which was indicated by the improvement of anodic peak current.  相似文献   

8.
The single-walled carbon nanotubes (SWCNTs) modified carbon ionic liquid electrode (CILE) was designed and further used for the voltammetric detection of rutin in this paper. CILE was prepared by mixing graphite powder with ionic liquid (IL) 1-butyl-3-methylimidazolium tetrafluoroborate and liquid paraffin together. Based on the interaction of SWCNTs with IL present on the electrode surface, a stable SWCNTs film was formed on the CILE to get a modified electrode denoted as SWCNTs/CILE. The characteristics of SWCNTs/CILE were recorded by different methods including cyclic voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy. The electrochemical behaviors of rutin on the SWCNTs/CILE were investigated by cyclic voltammetry and differential pulse voltammetry. Due to the specific interface provided by the SWCNTs-IL film, the electrochemical response of rutin was greatly enhanced with a pair of well-defined redox peaks appeared in pH 2.5 phosphate buffer solution. The oxidation peak currents showed good linear relationship with the rutin concentration in the range from 1.0 × 10− 7 to 8.0 × 10− 4 mol/L with the detection limit as 7.0 × 10− 8 mol/L (3σ). The SWCNTs/CILE showed the advantages such as excellent selectivity, improved performance, good stability and it was further applied to the rutin tablets sample detection with satisfactory results.  相似文献   

9.
A new electrochemical sensor for the determination of norepinephrine (NE), acetaminophen (AC) and tryptophan (TRP) is described. The sensor is based on carbon paste electrode (CPE) modified with 5-mino-3′,4′-dimethyl-biphenyl-2-ol (5ADB) and takes the advantages of carbon nanotubes (CNTs), which makes the modified electrode highly sensitive for the electrochemical detection of these compounds. Under the optimum pH of 7.0, the oxidation of NE occurs at a potential about 170 mV less positive than that of the unmodified CPE. Also, square wave voltammetry (SWV) was used for the simultaneous determination of NE, AC and TRP at the modified electrode.  相似文献   

10.
This study presents the preparation of regenerated cellulose (RC)/graphene nanoplatelets (GNPs) nanocomposites via room temperature ionic liquid, 1-ethyl-3-methylimidazolium acetate (EMIMAc) using solution casting method. The thermal stability, gas permeability, water absorption and mechanical properties of the films were studied. The synthesized nanocomposite films were characterized by Fourier transform infrared (FTIR), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The T20 decomposition temperature of regenerated cellulose improved with the addition of graphene nanoplatelets up to 5 wt%. The tensile strength and Young's modulus of RC films improved by 34 and 56%, respectively with the addition of 3 wt% GNPs. The nanocomposite films exhibited improved oxygen and carbon dioxide gas barrier properties and water absorption resistance compared to RC. XRD and SEM results showed good interaction between RC and GNPs and well dispersion of graphene nanoplatelets in regenerated cellulose. The FTIR spectra showed that the addition of GNPs in RC did not result in any noticeable change in its chemical structure.  相似文献   

11.
12.
Journal of Materials Science: Materials in Electronics - This study applied screen printed graphite electrode (SPGE) modified with the Fe2MoO4 magnetic nanocomposite for simultaneously determining...  相似文献   

13.
Journal of Materials Science: Materials in Electronics - Nanostructured V2O5/rGO nanocomposites were prepared by chemical reduction method process with different concentrations of V2O5 content to...  相似文献   

14.
A biocompatible electrochemical sensor for selective detection of epinephrine (EP) in the presence of 1000-fold excess of ascorbic acid (AA) and uric acid (UA) was fabricated by modifying the carbon paste electrode (CPE) with multi-walled carbon nanotubes (MWCNTs) using a casting method. The electro-catalytic activity of the modified electrode for the oxidation of EP was investigated. The current sensitivity of EP was enhanced to about five times upon modification. A very minimum amount of modifier was used for modification. The voltammetric response of EP was well resolved from the responses of AA and UA. The electrochemical impedance spectroscopic (EIS) studies reveal the least charge transfer resistance for the modified electrode. The AA peak that is completely resolved from that of EP at higher concentrations of AA and the inability of the sensor to give an electrochemical response for AA below a concentration of 3.0 × 10? 4 M makes it a unique electrochemical sensor for the detection of EP which is 100% free from the interference of AA. Two linear dynamic ranges of 1.0 × 10? 4–1.0 × 10? 5 and 1.0 × 10? 5–5.0 × 10? 7 M with a detection limit of 2.9 × 10? 8 M were observed for EP at modified electrode. The practical utility of this modified electrode was demonstrated by detecting EP in spiked human blood serum and EP injection. The modified electrode is highly reproducible and stable with anti fouling effects.  相似文献   

15.
This study aimed at preparing and evaluating the europium oxide–reduced graphene oxide (rGO) composites. Inorganic nanoparticles anchored onto rGO sheets through a facile sonochemical method. The resultant products were characterized by FT-IR, XRD, SEM. Their activity in biomolecules’ analysis were examined by cyclic voltammetry. The rectified electrodes revealed an incredibly electroactive manner. The obtained progress provided excellent materials for scrutiny of biomolecules. The linear relationship was used in the region of 100–1500 µM ascorbic acid (AA), 50–600 µM dopamine (DA), and 10–700 µM uric acid (UA), between current intensities and concentrations. The detection restrictions (LOD) (S/N?=?3) decreased to 8 µM, 1.1 µM and 0.085 µM for AA, DA and UA respectively by differential pulse voltammetry (DPV).  相似文献   

16.
采用粉末叠层方法和热压工艺制备了还原氧化石墨烯改性碳纤维/聚苯硫醚(RGO-CF/PPS)复合材料,考察了复合材料在室温干态和湿热处理两种条件下的层间剪切性能和微观形貌及RGO对复合材料界面性能的影响。结果表明,室温干态0.1%RGO-CF/PPS的层间剪切强度(ILSS)比CF/PPS的提高了18.4%;湿热处理后RGO-CF/PPS的ILSS发生了下降,且湿热处理RGO-CF/PPS的ILSS强度保持率均低于CF/PPS;复合材料的动态热机械行为结果表明,RGO有助于改善复合材料的界面黏结性能;微观形貌分析表明RGO使复合材料中裂纹更易发生偏转从而提高室温干态复合材料的ILSS。  相似文献   

17.
A carbon-paste electrode modified with multiwall carbon nanotubes (MWCNTs) was used for the sensitive and selective voltammetric determination of ascorbic acid (AA) in the presence of 3,4-dihydroxycinnamic acid (3,4-DHCA) as mediator. The mediated oxidation of AA at the modified electrode was investigated by cyclic voltammetry (CV), chronoamperommetry and electrochemical impedance spectroscopy (EIS). Also, the values of catalytic rate constant (k), and diffusion coefficient (D) for AA were calculated. Using square wave voltammetry (SWV), a highly selective and simultaneous determination of AA, acetaminophen (AC) and tryptophan (Trp) has been explored at the modified electrode. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of AA, AC and Trp into three well-defined voltammetric peaks. In the mixture containing AA, AC and Trp, the three compounds can well separate from each other with potential differences of 200, 330 and 530 mV between AA and AC, AC and Trp and AA and Trp, respectively, which was large enough to determine AA, AC and Trp individually and simultaneously.  相似文献   

18.
19.
A self-catalytic carbon paste electrode for the detection of vitamin B12   总被引:1,自引:0,他引:1  
A simple, sensitive, and selective method for the detection of vitamin B12 (cyanocobalamin) is presented. A carbon paste electrode has been constructed with trans-1,2-dibromocyclohexane (DBCH) acting as both the paste binder and a reactive material facilitating the electrocatalytic detection of the target. The latter reaction is based on the electroreduction of the Co(III) center in vitamin B12 to Co(I), which specifically reacts with DBCH to produce electrocatalytic currents with the regeneration of Co (II); a detection limit of 8.5 x 10(-10) mol dm(-3) (based on 3sigma) was found. The electrode has been successfully used for the quantification of vitamin B12 in pharmaceutical products and biological matrix media.  相似文献   

20.
Journal of Materials Science: Materials in Electronics - Reduced graphene oxide/cadmium meta niobate (RGOCN) hybrid nanocomposite was hydrothermally synthesised and subjected to structural...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号