首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
First, we developed quantitative analytical methods of water in poly(methyl methacrylate) (PMMA) in various hydrated states by utilizing the first combination and OH stretching bands of water at about 5240 and 3630 cm-1, respectively. Next, we investigated how the state of water depended on its quantity or the mole ratio of water to the CO (denoted as the H2O/CO ratio), which only interacts with water in PMMA, mainly on the basis of the band feature of the OH stretching bands. Below the H2O/CO ratio of 0.032, the contained water, which shows two clear bands at about 3630 and 3550 cm-1, is hydrogen-bonded to two C=O groups as C=O::H-O-H::O=C to form "the hydration core". The spectrum of the water that exceeds the ratio in question shows one broader band only, the frequency of which shifts downward with the increasing hydration. From detailed analysis of the behavior of the OH stretching and combination bands in relation to the H2O/CO ratio, we have concluded that the water that exceeds the hydration ratio becomes mobile to aggregate or "cluster" around hydrated sites rather than nonhydrated ones in the PMMA matrix, although the latter is much larger in population.  相似文献   

2.
The stable-oxygen and -hydrogen isotopic values (deltaD, delta18O) of porewater in geologic media are commonly determined on water obtained by extraction techniques such as centrifugation, mechanical squeezing, vacuum heating and cryogenic microdistillation, and azeotropic distillation. Each of these techniques may cause isotopic fractionation as part the extraction process and each is laborious. Here we demonstrate a new approach to obtain automated, high-precision deltaD and delta18O measurements of porewater in geologic sediments by direct H2- and CO2-porewater equilibration using a modified commercial CO2-water equilibrator. This technique provides an important and cost-effective improvement over current extraction methods, because many samples can be rapidly analyzed with minimal handling, thereby reducing errors and potential for isotopic fractionation. The precision and accuracy of direct H2- and CO2-porewater equilibration is comparable to or better than current porewater extraction methods. Finally, the direct equilibration technique allows investigators to obtain high-resolution (cm scale) porewater deltaD and delta18O profiles using cores from individual boreholes, eliminating the need for costly piezometers or conventional porewater extractions.  相似文献   

3.
Water and carbon dioxide concentrations within individual and selected groups of fluid inclusions in quartz were analyzed by using laser decrepitation and quantitative capacitance manometer determination. The useful limit of detection (calculated as ten times the typical background level) is about 5 x 10(-10) mol of H2O and 5 x 10(-11) mol of CO2; this H2O content translates into an aqueous fluid inclusion approximately 25 micrometers in diameter. CO2/H2O determinations for 38 samples (100 separate measurements) have a range of H2O amounts of 5.119 x 10(-9) to 1.261 x 10(-7) mol; CO2 amounts of 7.216 x 10(-10) to 1.488 x 10(-8) mol, and CO2/H2O mole ratios of 0.011 to 1.241. Replicate mole ratio determinations of CO2/H2O for three identical (?) clusters of inclusions in quartz have average mole ratios of 0.0305 +/- 0.0041 1 sigma. Our method offers much promise for analysis of individual fluid inclusions, is sensitive, is selective when the laser energy is not so great as to melt the mineral (laser pits approximately 50 micrometers in diameter), and permits rapid analysis (approximately 1 h per sample analysis).  相似文献   

4.
Newly available gas analyzers based on off-axis integrated cavity output spectroscopy (OA-ICOS) lasers have been advocated as an alternative to conventional isotope-ratio mass spectrometers (IRMS) for the stable isotopic analysis of water samples. In the case of H2O, OA-ICOS is attractive because it has comparatively low capital and maintenance costs, the instrument is small and field laboratory portable, and provides simultaneous D/H and 16O/18O ratio measurements directly on H2O molecules with no conversion of H2O to H2, CO, or H2/CO2-water equilibration required. Here we present a detailed assessment of the performance of a liquid-water isotope analyzer, including instrument precision, estimates of sample memory and sample mass effects, and instrumental drift. We provide a recommended analysis procedure to achieve optimum results using OA-ICOS. Our results show that, by using a systematic sample analysis and data normalization procedure routine, measurement accuracies of +/-0.8 per thousand for deltaD and +/-0.1 per thousand delta18O are achievable on nanoliter water samples. This is equivalent or better than current IRMS-based methods and at a comparable sample throughput rate.  相似文献   

5.
Teichert H  Fernholz T  Ebert V 《Applied optics》2003,42(12):2043-2051
We present what is to our knowledge the first near-infrared diode-laser-based absorption spectrometer that is suitable for simultaneous in situ measurement of carbon monoxide, water vapor, and temperature in the combustion chamber (20-m diameter, 13-m path length) of a 600-MW lignite-fired power plant. A fiber-coupled distributed-feedback diode-laser module at 1.56 microm served for CO detection, and a Fabry-Perot diode laser at 813 nm was used to determine H2O concentrations and temperature from multiline water spectra. Despite severe light losses (transmission, <10(-8)) and strong background radiation we achieved a resolution of 1.9 x 10(-4) (1sigma) fractional absorption, equivalent to 200 parts in 10(6) by volume of CO (at 1450 K, 10(5) Pa) with 30-s averaging time.  相似文献   

6.
Detailed here is a method for extracting and analyzing oxygen and hydrogen isotopes from 10 microL-sized water samples. Based on the traditional CO2-H2O equilibration technique, the oxygen isotope exchange reaction is done exclusively in sealed 6-mm (o.d.) Pyrex tubes at 25 degrees C, with full isotope exchange completed in at least 28 h. Using the same water sample employed in the 18O equilibration, D/H extractions are done in separate sealed 6-mm (o.d.) Pyrex tubes by reaction with Zn at 450 degrees C to form H2(g). Provided that a correction factor is applied to 18O analyses, accuracy and precision for both 18O and D/H are comparable to standard techniques using much larger samples.  相似文献   

7.
程烦  王煤 《低温与特气》2013,31(3):19-24
采用一种改进型的多组分等温线模型,运用Aspen Adsorption软件模拟空分过程中吸附塔内13X分子筛吸附空气中微量水蒸气和二氧化碳的过程。考察了操作压力、温度变化对穿透时间的影响以及水蒸气、二氧化碳在床层中的负载分布。研究结果表明:当压力从120 kPa增大到350 kPa,H2O和CO2的穿透时间分别增加32%和116%;在10~30℃,随着温度的升高,穿透时间点逐渐前移,但变化幅度较小;在CO2和H2O的竞争吸附中,CO2吸附能力明显弱于H2O,其饱和吸附量仅为H2O饱和吸附量的0.34%。  相似文献   

8.
Simple measurements of H2O2 concentration or CO2 evolution were used to evaluate the effectiveness of the use of Fenton's reagent to mineralize organic compounds in water and soil contaminated by crude petroleum. This methodology is suitable for application in small treatment and remediation facilities. Reagent concentrations of H2O2 and Fe(2+) were found to influence the reaction time and temperature, as well as the degree of mineralization and biodegradability of the sample contaminants. Some H2O2/Fe(2+) combinations (H2O2 greater than 10% and Fe(2+) greater than 50mM) resulted in a strong exothermic reaction, which causes peroxide degradation and violent gas liberation. Up to 75% TOC removal efficiency was attained in water and 70% in soil when high H2O2 (20%) and low Fe(2+) (1mM) concentrations were used. Besides increasing the degree of mineralization, the Fenton's reaction enhances the biodegradability of petroleum compounds (BOD5/COD ratios) by a factor of up to 3.8 for contaminated samples of both water and soil. Our experiments showed that low reagent concentrations (1% H2O2 and 1mM Fe(2+)) were sufficient to start the degradation process, which could be continued using microorganisms. This leads to a decrease in reagent costs in the treatment of petroleum-contaminated water and soil samples. The simple measurements of H2O2 concentration or CO2 evolution were effective to evaluate the Fenton's reaction efficiency.  相似文献   

9.
Hall RJ  Stufflebeam JH 《Applied optics》1984,23(23):4319-4327
Experimental and theoretical investigations of the CARS spectroscopy of CO2(2v2) and N2O(v3) were carried out. The experimental spectra were measured in a heated test cell, and excellent agreement with the observed temperature dependences was obtained from numerical simulations. Assignments were made for all hot bands, and the role of collisional narrowing was quantified. Observed nonresonant susceptibility effects in pure N2O have made it possible to estimate the nonresonant background susceptibility for this molecule by using the resonant contribution as a reference calibration.  相似文献   

10.
Two low-cost synthesis routes have been developed to fabricate carbon-coated Li4Ti5O12 by using H2TiO3 instead of anatase TiO2 as Ti source through solid-state reaction process. One route is a direct solid mixture of H2TiO3, Li2CO3 and pitch followed by high-temperature solid-state reaction. The other includes mixture of H2TiO3 and Li2CO3 with pitch dissolved in furanidine under vacuum and the same solid-state reaction procedure is followed after the mixture is totally dried. Microstructural investigations indicate that H2TiO3 exhibits secondary aggregates morphology with primary particle sizes of 10-20 nm. Carbon-coating layers with thickness of 2-3 nm have been observed on Li4Ti5O12 synthesized by the two routes. Cyclic performance, rate capability and electrochemical impedance spectrum of the two Li4Ti5O12/C composites have been performed, which indicate that Li4Ti5O12/C obtained by furanidine-assisted mixture exhibits better electrochemical performance than Li4Ti5O12/C synthesized by direct solid mixture. The possible reasons have been discussed. The low-cost synthesis routes of Li4Ti5O12/C using H2TiO3 as Ti source are expected to be more competitive than the traditional one for practical applications.  相似文献   

11.
We reproduced the chemical-physical conditions of fumarolic emission at Phlaegrean Fields, Pozzuoli, Italy, and we measured the CO(2) and H(2)O concentrations using an absorption spectrometer based on two distributed feedback laser diodes at wavelengths of 1.578 and 1.393 mum. We discuss the accuracy levels of the different methods used. Furthermore, we measured the broadening coefficients for H(2)O (self-broadening, 28.2 +/- 0.6 MHz/Torr; CO(2) broadening, 6.0 +/- 0.4 MHz/Torr) and CO(2) (self-broadening, 3.2 +/- 0.1 MHz/Torr; H(2)O broadening, 4.0 +/- 0.1 MHz/Torr). Using the present data, we evaluated a minimum detectable variation of 9% for H(2)O and 1% for CO(2).  相似文献   

12.
通过正硅酸乙酯与苯基三乙氧基硅烷共水解缩聚反应制备苯基修饰SiO2膜,研究膜材料的氢气渗透和分离性能,并将其作为膜反应器的关键材料应用于水煤气变换反应.结果表明,氢气在苯基修饰SiO2膜中的渗透率随着温度的升高而增大,遵循活化扩散机理,300℃下H2渗透率达到4.67×10-7 mol/(m2·s·Pa),理想分离系数H2/CO、H2/CO2和H2/SF6分别达到10.54、10.50、21.16.在300℃,反应物H2O/CO摩尔比为2∶1的条件下进行水煤气变换反应,膜反应器的CO的转化率比传统固定床反应的CO的转化率高约12%,其原因是苯基修饰的SiO2膜对H2具有一定的选择性.  相似文献   

13.
Few studies have used the stable isotopic composition of O(2) as a tracer of gas transport or biogeochemical processes in environmental research. Here we demonstrate field sampling techniques for gaseous and dissolved O(2) and describe an analytical method for measuring δ(18)O and δ(17)O values of O(2) in air, soil gas, and water samples using continuous-flow isotope-ratio mass spectrometry (CF-IRMS). A Micromass CF-IRMS was altered to accommodate a sample gas injection port prior to a CO(2) and H(2)O trap and GC column. The GC column was a 1-m, 5-? molecular sieve column held at 35 °C. The resolved sample O(2) was introduced to the IRMS via an open split. δ(18)O and δ(17)O values were determined by measurement of O(2) isotopes at m/z 34/32 and 33/32 and comparison to a reference pulse of O(2). Repeated injections of atmospheric oxygen yielded a repeatability (±SD) of ±0.17‰ for δ(18)O and ±0.5‰ for δ(17)O. IRMS source linearity was excellent for O(2) over a sample size range of 60-400 μL. The smallest sample for routine δ(18)O and δ(17)O determinations was ~80 μL of O(2), with a sample analysis time of 180 s. Preliminary results from a riverine and soil gas study illustrate natural oxygen isotope fractionation processes.  相似文献   

14.
A new, completely automated gas chromatography technique has been developed to separate the different gaseous compounds produced during underground coal gasification for their (13)C/(12)C and D/H isotope ratio measurements. The technique was designed for separation and collection of H(2), CO, CO(2), H(2)O, H(2)S, CH(4), and heavier hydrocarbons. These gaseous compounds are perfectly separated by the gas-phase chromatograph and quantitatively sent to seven combustion and collection lines. H(2), CO, CH(4), and heavier hydrocarbons are quantitatively oxidized to CO(2) and/or H(2)O. The isotopic analyses are performed by the sealed-tube method. The zinc method is used for reduction of both water and H(2)S to hydrogen for D/H analysis. Including all preparation steps, the reproducibility of isotope abundance values, for a quantity higher than or equal to 0.1 mL of individual components in a mixture (5 mL of gases being initially injected in the gas chromatograph), is ±0.1‰ for δ(13)C(PDB) and ±6‰ for δD(SMOW).  相似文献   

15.
Spatially resolved deep-ultraviolet (UV) Raman spectroscopy was applied to solutions of CO(2) and H(2)O or D(2)O subject to a temperature gradient in a thermally regulated high-pressure concentric-tube Raman cell in an attempt to measure a Soret effect in the vicinity of the critical point of CO(2). Although Raman spectra of solutions of CO(2) dissolved in D(2)O, at 10 MPa and temperatures near the critical point of CO(2), had adequate signal-to-noise and spatial resolution to observe a Soret effect with a Soret coefficient with magnitude |S(T)| > 0.03, no evidence for an effect of this size was obtained for applied temperature gradients up to 19 °C. In contrast, the concentration of CO(2) dissolved in H(2)O was shown to vary significantly across the temperature gradient when excess CO(2) was present, but the results could be explained simply by the variation in CO(2) solubility over the temperature range and not by kinetic factors. For mixtures of D(2)O dissolved in scCO(2) at 10 MPa and temperatures close to the critical point of CO(2), the Raman peaks for D(2)O were too weak to measure with confidence even at the limit of D(2)O solubility.  相似文献   

16.
Electrochemical reduction of dioxygen in aqueous media can proceed to water, hydrogen peroxide, or a mixture of the two. The production of hydrogen peroxide, classically established with the rotated ring-disk electrode, can also be quantitatively assessed at interdigitated array (IDA) electrodes, where dioxygen is reduced at the set of microband generator electrodes and any H(2)O(2) produced is detected by its oxidation (back to O(2)) at the interdigitated set of microband collector electrodes. The sensitivity of the IDA for H(2)O(2) detection is higher owing to its more complete collection, and to the ensuing regeneration of O(2), which leads to an amplification of the generator currents. The production of H(2)O(2) is thus reflected both in the ratio of collector and generator electrode currents [the collection efficiency, coll(τ)] and in the ratio of the generator current with the collector potential on to that with it off [amplification factor, ampl(τ)]. The necessary theory for interpretation of the fraction ε of H(2)O(2) produced per dioxygen reduced is presented, based on conformal mapping techniques. Explicit equations are derived for ε at long times that are independent of the IDA dimensions and that can be used with any two-product electrochemical reaction analogous to the dioxygen reduction. Experimental data are presented for dioxygen reduction in acidic and basic media to illustrate application of the theory.  相似文献   

17.
This paper presents the development of a static headspace capillary gas chromatographic method (HS-GC) for simultaneously determining dissolved gases (H2, O2, N2, CO, CO2, CH4, C2H6, C2H4, C2H2, C3H8) and moisture from a unique 15-mL mineral oil sample. A headspace sampler device is used to equilibrate the sample species in a two-phase system under controlled temperature and agitation conditions. A portion of the equilibrated species is then automatically split-injected into two chromatographic channels mounted on the same GC for their separation. The hydrocarbons and the lighter gases are separated on the first channel by a GS-Q column coupled with a MolSieve 5-A column via a bypass valve, while the moisture is separated on the second channel using a Stabilwax column. The analytes are detected by using two universal pulsed-discharge helium ionization detectors (PDHID). The performance of the method was established using equilibrated vials containing known amounts of gas mixture, water, and blank oil. The signal is linear over the concentration ranges normally found for samples collected from open-breathing power transformers. Determination sensitivity varies with the nature of the species considered with values as high as 21 500 A x 10(-9) s (microg/ g)(-1) for H2O, 46-216 A x 10(-9) s (microL/L)(-1) for the hydrocarbons and carbon oxides, and as low as 8-21 A x 10(-9) s (microL/L)(-1) for the O2 and N2 permanent gases. The detection limit of the method is between 0.08 and 6 microL/L for the dissolved gases, except for O2, N2, and CO2, where higher values are observed due to air intrusion during sampler operations, and 0.1 microg/g for the dissolved water. Ten consecutive measurements in the low and high levels of the calibration curves have shown a precision better than 12% and 6%, respectively, in all cases. A comparison study between the HS-GC method and the ASTM standard procedures on 31 field samples showed a very good agreement of the results. The advantages of configuring the arrangement with two PDHID over the conventional flame ionization and thermal conductivity detectors were clearly demonstrated.  相似文献   

18.
Taczak TM  Killinger DK 《Applied optics》1998,37(36):8460-8476
A smoothly tunable, narrow-linewidth, cw, 32-mW, 2.066-mum Ho:YLF laser was constructed and used for the first time in preliminary spectroscopic measurements of atmospheric CO(2) and H(2)O. The laser was constructed with a 4.5-mm-long, TE-cooled, codoped 5% Tm and 0.5% Ho yttrium lithium fluoride crystal (cut at Brewster's angle) pumped by an Ar(+)-pumped 500-mW Ti:sapphire laser operating at 792 nm. Intracavity etalons were used to reduce the laser linewidth to approximately 0.025 cm(-1) (0.75 GHz), and the laser wavelength was continuously and smoothly tunable over approximately 6 cm(-1) (180 GHz). The Ho:YLF laser was used to perform spectroscopic measurements on molecular CO(2) in a laboratory absorption cell and to measure the concentration of CO(2) and water vapor in the atmosphere with an initial accuracy of approximately 5-10%. The measurement uncertainty was found to be due to several noise sources, including the effect of asymmetric intensity of the laser modes within the laser linewidth, fluctuations caused by atmospheric turbulence and laser beam/target movement, and background spectral shifts.  相似文献   

19.
CO2 is a major component of the greenhouse gases, which causes the global warming. To reduce CO2 gas, high activity nanosized Ni+2 substituted Fe2TiO5 samples were synthesized by conventional ceramic method. The effect of the composition of the synthesized ferrite on the H2-reduction and CO2-catalytic decomposition was investigated. Fe2TiO5 (iron titanate) phase that has a nanocrystallite size of -80 nm is formed as a result of heating Fe2O3 and TiO2 while the addition of NiO leads to the formation of new phases (-80 nm) NiTiO3 and NiFe2O4, but the mixed solid of NiO and Fe2O3 results in the formation of NiFe2O4 only. Samples with Ni^+2=0 shows the lowest reduction extent (20%); as the extent of Ni+2 increases, the extent of reduction increases. The increase in the reduction percent is attributed to the presence of NiTiO3 and NiFe2O4 phases, which are more reducible phases than Fe2TiO5. The CO2 decomposition reactions were monitored by thermogravimetric analysis (TGA) experiments. The oxidation of the H2-reduced Ni+2 substituted Fe2TiO5 at 500℃ was investigated. As Ni^+2 increases, the rate of reoxidation increases. Samples with the highest reduction extents gave the highest reoxidation extent, which is attributed to the highly porous nature and deficiency in oxygen due to the presence of metallic Fe, Ni and/or FeNi alloy. X-ray diffraction (XRD) and transmission electron microscopy (TEM) of oxidized samples show also the presence of carbon in the sample containing Ni+2〉0, which appears in the form of nanotubes (25 nm).  相似文献   

20.
Lin JM  Yamada M 《Analytical chemistry》1999,71(9):1760-1766
The oxidation reaction between periodate and polyhydroxyl compounds was studied. A strong chemiluminescent (CL) emission was observed when the reaction took place in a strong alkaline solution without any special CL reagent. However, in acidic or neutral solution, it was hard to record the CL with our instrument. It was interesting to find that in the presence of carbonate the CL signal was enhanced significantly. When O(2) gas and N(2) gas were blown into the reagent solutions, both background and CL signals of the sample were enhanced by O(2) and decreased by N(2). The spectral distribution of the CL emission showed two main bands (λ = 436-446 and 471-478 nm). Based on the studies of the spectra of CL, fluorescence and UV-visible, a possible CL mechanism was proposed. In strongly alkaline solution, periodate reacts with the dissolved oxygen to produce superoxide radical ions. A microamount of singlet oxygen ((1)O(2)*) could be produced from the superoxide radicals. A part of the superoxide radicals acts on carbonates and/or bicarbonates leading to the generation of carbonate radicals. Recombination of carbonate radicals may generate excited triplet dimers of two CO(2) molecules ((CO(2))(2)*). Mixing of periodate with carbonate generated were very few (1)O(2)* and (CO(2))(2)*. These two emitters contribute to the CL background. The addition of polyhydroxyl compounds or H(2)O(2) caused enhancement of the CL signal. It may be due to the production of (1)O(2)* during the oxidized decomposition of the analytes in periodate solution. This reaction system has been established as a flow injection analysis for H(2)O(2), pyrogallol, and α-thioglycerol and their detection limits were 5 × 10(-)(9), 5 × 10(-)(9), and 1 × 10(-)(8) M, respectively. Considering the effective reaction ions, IO(4)(-), CO(3)(2)(-), and OH(-) could be immobilized on a strongly basic anion-exchange resin. A highly sensitive flow CL sensor for H(2)O(2), pyrogallol, and α-thioglycerol was also prepared.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号