首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
为强化城市污水脱氮除磷,研发了厌氧/缺氧/好氧/缺氧-膜生物反应器(A2/O/A-MBR)新工艺,并建设了设计处理规模为2万m3/d实际工程.对该工程的长期监测表明,出水C()D、TN、NH4+-N和TP的平均浓度分别为20.6、6.67、1.05、0.19 mg/L,优于《城镇污水处理厂污染物排放标准》中的一级A标准...  相似文献   

2.
Struvite precipitation was applied to the removal of NH(4)-N in semiconductor wastewater. Batch experiments were conducted to examine the effects of final pH, magnesium and orthophosphate dosages and the initial influent concentrations of NH(4)-N and F on the removals of NH(4)-N and PO(4)-P by forming struvite deposits. pH was an important parameter in the simultaneous removals of ammonium nitrogen and orthophosphate. In struvite precipitation, the amount of orthophosphate in the solution affected NH(4)-N removal much more than that of magnesium ions in some cases. It was revealed that the low and high initial concentrations of NH(4)-N and F inhibited NH(4)-N and PO(4)-P removal efficiencies in struvite precipitation, respectively. We also evaluated field-scale treatment plant incorporated by struvite precipitation process. On semiconductor wastewater with an NH(4)-N concentration of 155 mg/L, the results obtained showed that the incorporation of the struvite precipitation process brought about a high NH(4)-N removal efficiency of over 89% on average.  相似文献   

3.
A feasible method for treatment of the wastewater from the two-staged neutralization in 2,2',5,5'-tetrachlorobenzidine (TCB) manufacturing processes, a refractory dye intermediate effluents, based on combined micro-electrochemical oxidation or iron-chipping filtration (ICF) and air-stripping reactor (ASR), was developed. On conditions of HRT 1h, pH 3.0 in ICF and HRT 38 h, gas-liquid ratio 15, pH 6.0-8.65, temperature 26 degrees C in ASR, the overall COD, color, TCB and NH(4)(+)-N removal were 96.8%, 91%, 87.61% and 62%, respectively, during the treatment of TCB wastewater from the two-staged neutralization dissolved by methanol. The averaged 18.3%, 81.7% of the total degraded COD, 35.2%, 64.8% of TCB were carried out in ICF and ASR, respectively. NH(4)(+)-N removal was finished mainly in ASR. The experimental results indicated that the combined micro-electrochemical oxidation and air-stripping process performed good treatment of COD, color, TCB and NH(4)(+)-N removal in TCB wastewater from the two-staged neutralization dissolved by ethanol or acetone, came up the discharge standard in China. But the TCB wastewater from the two-staged neutralization dissolved by methanol should be deeply treated before discharged.  相似文献   

4.
A laboratory-scale biological plant composed of two aerobic reactors operating at 35 degrees C was used to study the biodegradation of coke wastewater. The main pollutants to be removed are organic matter, especially phenols, thiocyanate and ammonium nitrogen. The concentrations of the main pollutants in the wastewater during the study ranged between 922 and 1,980 mg COD/L, 133 and 293 mg phenol/L, 176 and 362 mg SCN/L and 123 and 296 mg NH(4)(+)-N/L. The biodegradation of these pollutants was studied employing different hydraulic residence times (HRT) and final effluent recycling ratios in order to minimize inhibition phenomena attributable to the high concentrations of pollutants. During the optimisation of the operating conditions, the removal of COD, phenols and thiocyanate was carried out in the first reactor and the nitrification of ammonium took place in the second. The best results were obtained when operating at an HRT of 98 h in the first reactor and 86 h in the second reactor, employing a recycling ratio of 2. The maximum removal efficiencies obtained were 90.7, 98.9, 98.6 and 99.9% for COD, phenols, thiocyanate and NH(4)(+)-N, respectively. In order to remove nitrate, an additional reactor was also implemented to carry out the denitrification process, adding methanol as an external carbon source. Very high removal efficiencies (up to 99.2%) were achieved.  相似文献   

5.
In this paper, the technical applicability and treatment performance of physico-chemical techniques (individual and/or combined) for landfill leachate are reviewed. A particular focus is given to coagulation-flocculation, chemical precipitation, ammonium stripping, membrane filtration and adsorption. The advantages and limitations of various techniques are evaluated. Their operating conditions such as pH, dose required, characteristics of leachate in terms of chemical oxygen demand (COD) and NH3-N concentration and treatment efficiency are compared. It is evident from the survey of 118 papers (1983-2005) that none of the individual physico-chemical techniques is universally applicable or highly effective for the removal of recalcitrant compounds from stabilized leachate. Among the treatments reviewed in this article, adsorption, membrane filtration and chemical precipitation are the most frequently applied and studied worldwide. Both activated carbon adsorption and nanofiltration are effective for over 95% COD removal with COD concentrations ranging from 5690 to 17,000 mg/L. About 98% removal of NH3-N with an initial concentration ranging from 3260 to 5618 mg/L has been achieved using struvite precipitation. A combination of physico-chemical and biological treatments has demonstrated its effectiveness for the treatment of stabilized leachate. Almost complete removal of COD and NH3-N has been accomplished by a combination of reverse osmosis (RO) and an upflow anaerobic sludge blanket (UASB) with an initial COD concentration of 35,000 mg/L and NH3-N concentration of 1600 mg/L and/or RO and activated sludge with an initial COD concentration of 6440 mg/L and NH3-N concentration of 1153 mg/L. It is important to note that the selection of the most suitable treatment method for landfill leachate depends on the characteristics of landfill leachate, technical applicability and constraints, effluent discharge alternatives, cost-effectiveness, regulatory requirements and environmental impact.  相似文献   

6.
通过对新型生态膜反应器处理生活污水的试验研究,考察了不同水力停留时间(HRT)对反应器中去除CODer、NH,-N、TP污染物效果的影响。通过实验表明,在实际工况下,控制HRT为最佳工况状态,CODcr、NH3-N、TP的去除率分别达到80%、78%、65%以上,出水浓度可达到30mg/L、5mg/L、1mg/以下。出水水质达到国家标准《城镇污水处理厂污染物排放标准》(GB18918—2002)一级A标准要求。  相似文献   

7.
In order to treat pesticide wastewater having high chemical oxygen demand (COD) value and poor biodegradability, Fenton-coagulation process was first used to reduce COD and improve biodegradability and then was followed by biological treatment. Optimal experimental conditions for the Fenton process were determined to be Fe(2+) concentration of 40 mmol/L and H(2)O(2) dose of 97 mmol/L at initial pH 3. The interaction mechanism of organophosphorous pesticide and hydroxyl radicals was suggested to be the breakage of the P=S double bond and formation of sulfate ions and various organic intermediates, followed by formation of phosphate and consequent oxidation of intermediates. For the subsequent biological treatment, 3.2g/L Ca(OH)(2) was added to adjust the pH and further coagulate the pollutants. The COD value could be evidently decreased from 33,700 to 9300 mg/L and the ratio of biological oxygen demand (BOD(5)) to COD of the wastewater was enhanced to over 0.47 by Fenton oxidation and coagulation. The pre-treated wastewater was then subjected to biological oxidation by using moving-bed biofilm reactor (MBBR) inside which tube chip type bio-carriers were fluidized upon air bubbling. Higher than 85% of COD removal efficiency could be achieved when the bio-carrier volume fraction was kept more than 20% by feeding the pretreated wastewater containing 3000 mg/L of inlet COD at one day of hydraulic retention time (HRT), but a noticeable decrease in the COD removal efficiency when the carrier volume was decreased down to 10%, only 72% was observed. With the improvement of biodegradability by using Fenton pretreatment, also due to the high concentration of biomass and high biofilm activity using the fluidizing bio-carriers, high removal efficiency and stable operation could be achieved in the biological process even at a high COD loading of 37.5 gCOD/(m(2)carrierday).  相似文献   

8.
An up-flow biological aerated filter packed with two layers media was employed for tertiary treatment of textile wastewater secondary effluent. Under steady state conditions, good performance of the reactor was achieved and the average COD, NH(4)(+)-N and total nitrogen (TN) in the effluent were 31, 2 and 8mg/L, respectively. For a fixed dissolved oxygen (DO) concentration, an increase of hydraulic loading resulted in a decrease in substrate removal. With the increase of hydraulic loadings from 0.13 to 0.78m(3)/(m(2)h), the removal efficiencies of COD, NH(4)(+)-N and TN all decreased, which dropped from 52 to 38%, from 90 to 68% and from 45 to 33%, respectively. In addition, the results also confirmed that the increase of COD and NH(4)(+)-N removal efficiencies resulted from the increase of DO concentrations, but this variation trend was not observed for TN removal. With the increase of DO concentrations from 2.4 to 6.1mg/L, the removal efficiencies of COD and NH(4)(+)-N were 39-53% and 64-88%, whenas TN removal efficiencies increased from 39 to 42% and then dropped to 35%.  相似文献   

9.
Experiments were conducted to investigate the behavior of the integrated system with biofilm reactors and zero-valent iron (ZVI) process for coking wastewater treatment. Particular attention was paid to the performance of the integrated system for removal of organic and inorganic nitrogen compounds. Maximal removal efficiencies of chemical oxygen demand (COD), ammonia nitrogen (NH(3)-N) and total inorganic nitrogen (TIN) were up to 96.1, 99.2 and 92.3%, respectively. Moreover, it was found that some phenolic compounds were effectively removed. The refractory organic compounds were primarily removed in ZVI process of the integrated system. These compounds, with molecular weights either ranged 10,000-30,000 Da or 0-2000 Da, were mainly the humic acid (HA) and hydrophilic (HyI) compounds. Oxidation-reduction and coagulation were the main removal mechanisms in ZVI process, which could enhance the biodegradability of the system effluent. Furthermore, the integrated system showed a rapid recovery performance against the sudden loading shock and remained high efficiencies for pollutants removal. Overall, the integrated system was proved feasible for coking wastewater treatment in practical applications.  相似文献   

10.
Laboratory experiments were undertaken to investigate the treatment performances of ozonation alone and/or its combination with granular activated carbon (GAC) adsorption for raw leachate from the NENT landfill (in Hong Kong). To improve its removal of recalcitrant contaminants from the leachate, the surface of GAC was oxidized with ozone prior to treatment. With respect to ozone dose and pH, the removal of COD and/or NH(3)-N from ozonation alone and combined ozone-GAC adsorption were evaluated and compared to those of other physico-chemical treatments in some reported studies. The removal mechanism of recalcitrant compounds by ozone-GAC adsorption treatment was presented. Among the various treatments studied, the combination of ozone-GAC adsorption using ozone-modified GAC had the highest removal for COD (86%) and/or NH(3)-N (92%) compared to ozonation alone (COD: 35%; NH(3)-N: 50%) at the same initial COD and/or NH(3)-N concentrations of 8000 and 2620 mg/L, respectively. Although the integrated treatment was more effective than ozonation alone for treating stabilized leachate, the results suggested that it could not generate treated effluent that complied with the COD limit of lower than 200 mg/L and the NH(3)-N discharge standard of less than 5 mg/L. Therefore, further biological treatments to complement the degradation of the leachate are still required to meet the environmental legislation.  相似文献   

11.
A new catalytic oxidation of anionic surfactants by electrochemistry method was designed and used to investigate the removal of anionic surfactant from simulated wastewater. Synergetic effect on COD removal was studied when integrating the electrochemical reactor, using porous graphite as anode and cathode, with the effective CuO-Co2O3-PO4(3-) modified kaolin catalyst in a single undivided cell. The result showed that this combined process could effectively remove anionic surfactant. Its COD removal efficiency was much higher than those individual processes and could reach up to 90% in 60 min. The operating parameters such as initial pH, cell voltage, and current intensity were also investigated. Possible theory for COD removal was also proposed to predict the role of modified kaolin, electro-catalysis and oxidation in the combined process. The pollutants in wastewater could be decreased by the high reactive OH* that produced on the surface of catalyst by the decomposition of electrochemical generated H2O2. The result indicates that the catalytic oxidation by electrochemistry method is a promising wastewater treatment technique.  相似文献   

12.
Advanced oxidation processes were combined with biological treatment processes in this study to remove both pesticides and then the COD load from aqueous solutions. It was found that O(3) and O(3)/UV oxidation systems were able to reach 90 and 100%, removal of the pesticide Deltamethrin, respectively, in a period of 210 min. The use of O(3) combined with UV radiation enhances pesticides degradation and the residual pesticide reaches zero in the case of Deltamethrin. The combined O(3)/UV system can reduce COD up to 20% if the pH of the solution is above 4. Both pesticide degradation and COD removal in the combined O(3)/UV system follow the pseudo-first-order kinetics and the parameters of this model were evaluated. The application of the biological treatment to remove the bulk COD from different types of feed solution was investigated. More than 95% COD removal was achieved when treated wastewater by the O(3)/UV system was fed to the bioreactor. The parameters of the proposed Grau model were estimated.  相似文献   

13.
The feasibility study of the application of the photoelectrocatalytic decontamination of high saline produced water containing refractory organic pollutants was investigated in the slurry photoelectrocatalytic reactor with nanometer TiO2 particle prepared with sol-gel method using the acetic acid as hydrolytic catalyst. The efficiency of the photoelectrocatalytic decontamination of produced water was determined with both COD removal from the tested wastewater and the decrease of mutagenic activity evaluated by Ames tests. The experimental results showed that the photoelectrocatalysis is a quite efficient process for decontaminating the produced water, although there are high concentration of salt existed in oilfield wastewater. We found that the COD removal efficiencies by photoelectrocatalytic process are much higher than that of by photocatalytic or electrochemical oxidation individually in the photoelectrocatalytic reactor. The COD removal can be substantially improved by the added H2O2 and the generation of active chlorine from high concentration chlorides in the wastewater. The effects of various operating conditions, such as initial COD concentration, applied cell voltage, catalyst amount and initial pH value of solution, on the photoelectrocatalytic efficiencies, is also investigated in detail. The results showed that when the raw produced wastewater was diluted in a 1:1 (v/v) ratio, there is a highest COD removal efficiency. And the photoelectrocatalytic degradation of organic pollutants in saline water is much favored in acidic solution than that in neutral and/or alkaline solution.  相似文献   

14.
Advanced treatment of coking wastewater was investigated experimentally with coagulation and zero-valent iron (ZVI) processes. Particular attention was paid to the effect of dosage and pH on the removal of chemical oxygen demand (COD) in the two processes. The results showed that ZVI was more effective than coagulation for advanced treatment of coking wastewater. The jar tests revealed that maximal COD removal efficiency of 27.5-31.8% could be achieved under the optimal condition of coagulation, i.e. 400mg/L of Fe(2)(SO(4))3 as coagulant at pH 3.0-5.0. On the other hand, the COD removal efficiency could be up to 43.6% under the idealized condition of ZVI upon 10 g/L active carbon and 30 g/L iron being dosed at pH 4.0. The mechanisms for COD removal in ZVI were dominated by coagulation, precipitation and oxidation-reduction. ZVI would also enhance the biodegradability of effluent by increasing BOD5/COD from 0.07 to 0.53. Moreover, some ester compounds could be produced in the reaction. Although ZVI was found more efficient than coagulation in eliminating low molecular weight (<2000 Da) compounds in the wastewater, there were still a few residual contaminants which could hardly be eliminated by either of the process.  相似文献   

15.
A laboratory-scale activated sludge plant composed of a 20 L volume aerobic reactor followed by a 12 L volume settling tank and operating at 35 degrees C was used to study the biodegradation of coke wastewater. The concentrations of ammonium nitrogen (NH(4)(+) -N), phenols, chemical oxygen demand (COD) and thiocyanate (SCN(-)) in the wastewater ranged between 504 and 2,340, 110 and 350, 807 and 3,275 and 185 and 370 mg/L, respectively. The study was undertaken with and without the addition of bicarbonate. The addition of this inorganic carbon source was necessary to favour nitrification, as the alkalinity of the wastewater was very low. Maximum removal efficiencies of 75%, 98% and 90% were obtained for COD, phenols and thyocianates, respectively, without the addition of bicarbonate. The concentration of ammonia increased in the effluent due to both the formation of NH(4)(+) as a result of SCN(-) biodegradation and to organic nitrogen oxidation. A maximum nitrification efficiency of 71% was achieved when bicarbonate was added, the removals of COD and phenols being almost similar to those obtained in the absence of nitrification. Batch experiments were performed to study the influence of pH and alkalinity on the biodegradation of phenols and thiocyanate.  相似文献   

16.
The electrochemical oxidation of anionic surfactants (sodium dodecyl benzene sulfonate, DBS) contained in simulated wastewater treated by three-dimensional electrode system with combined modified kaolin served as packed bed particle electrodes and Ti/Co/SnO(2)-Sb(2)O(3) anode was studied, the chemical oxygen demand (COD) removal of pollutants in the solutions was also investigated. The results showed that the three-dimensional electrodes in combined process could effectively decompose anionic surfactants. The COD removal efficiency can reach 86%, much higher than that of Ti/Co/SnO(2)-Sb(2)O(3) electrodes used singly or modified kaolin employed singly (graphite as anode and cathode) on the same condition of pH 3 and 38.1 mA/cm(2) current density. The current efficiency and kinetic constant were calculated and energy consumption was studied. At the same time the influence of pH and current density on COD removal efficiency with combined three-dimensional electrodes was also investigated, respectively. The optimal initial pH value of degradation is 3 (acid condition), and a minor COD removal increase follows higher current density.  相似文献   

17.
就可反洗平板浸没式膜生物反应器和传统平板浸没式膜生物反应器处理园区生活污水的效果进行比较研究,发现在水力停留时间同为9.6h的条件下,两者几无区别,COD和NH3-N的去除率同样分别为90%和95%,浊度均降至0.7NTU以下,也均无SS检出,出水水质都达到国家生活杂用水水质标准(GB/T18920-2002);但前者因膜具可反洗性,可以延缓膜污染,延长系统稳定运行周期,减少化学清洗频率,既降低运行成本,延长膜使用寿命,又减少化学清洗剂对环境的污染.  相似文献   

18.
Chemically enhanced primary treatment (CEPT) is a technology that uses coagulants for enhanced pollutants removal at the primary stage of the wastewater treatment. This paper presents the detailed characteristics of tannery wastewater. It also explains effectiveness of CEPT in removing pollutants from tannery wastewater using various metal salts. The results of this study demonstrated that the tannery effluent had high concentrations of organic matter, solids, sulfates, sulfides and chromium. Alum, ferric chloride and ferric sulfate were tested as coagulants using jar test apparatus. Alum was found to be the suitable coagulant for tannery wastewater in a dose range of 200-240 mg/L as Al(2)(SO(4))(3). With alum, percentage removal efficiency for turbidity, total suspended solids (TSS), chemical oxygen demand (COD) and chromium was found to be 98.7-99.8, 94.3-97.1, 53.3-60.9, and 98.9-99.7%, respectively. National effluent quality standards for total suspended solids and chromium were met after CEPT. However, COD content was high, emphasizing the need of secondary treatment for the tannery effluent.  相似文献   

19.
Two new applications for sequence treatment of mature (stabilized) landfill leachate, that is, cationic resin followed by anionic resin (cationic/anionic) and anionic resin followed by cationic resin (anionic/cationic), are employed and documented for the first time in the literature. Response surface methodology (RSM) concerning central composite design (CCD) is used to optimize each treatment process, as well as evaluate the individual and interactive effects of operational cationic resin dosage and anionic resin dosage on the effectiveness of each application in terms of color, chemical oxygen demand (COD), and NH(3)-N removal efficiency. A statistically significant model for color, COD, and NH(3)-N removal was obtained with high coefficient of determination values (R(2)>0.8). Under optimum operational conditions, the removal efficiency levels for color, COD, and NH(3)-N are 96.8%, 87.9%, and 93.8% via cationic/anionic sequence, and 91.6%, 72.3%, and 92.5% via anionic/cationic sequence, respectively. The experimental results and the model predictions agree well with each other.  相似文献   

20.
This work was undertaken to investigate the cause of sludge acidification that led to disruption of the activated sludge process treating coking wastewater from a steel-making plant in Taiwan. An activated sludge reactor (ASR) with a working volume of 80 L was used as a model system to simulate the behavior of the real wastewater treatment process. Parameters that may cause acidification or inactivation of the sludge (NH(3), SCN(-), S(2)O(3)(2-) and CN(-)) were studied individually to examine for their effects on the performance of the ASR. The results show that high loading of NH(3), SCN(-) and CN(-) did not lead to pH decrease, while the ASR attained 85% COD removal and nearly 100% SCN degradation. In contrast, when the wastewater was supplemented with ca. 1,000 mg/L of S(2)O(3)(2-), the pH dropped to nearly 4.0 in 2 days and the COD and SCN removal yields were significantly lower (at 50 and 0-20%, respectively). Thus, overloading of S(2)O(3)(2-) was apparently a key factor causing sludge acidification. The results suggest that to ensure a normal functioning of the activated sludge, the influent S(2)O(3)(2-) concentration should be closely monitored and that the pH control of the ASR is indispensable when the S(2)O(3)(2-) loading is in excess.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号