首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Journal of power sources》2006,154(2):394-403
Electrical output behaviour obtained on solid oxide fuel cell stacks, based on planar anode supported cells (50 or 100 cm2 active area) and metallic interconnects, is reported. Stacks (1–12 cells) have been operated with cathode air and anode hydrogen flows between 750 and 800 °C operating temperature. At first polarisation, an activation phase (increase in power density) is typically observed, ascribed to the cathode but not clarified. Activation may extend over days or weeks. The materials are fairly resistant to thermal cycling. A 1-cell stack cycled five times in 4 days at heating/cooling rates of 100–300 K h−1, showed no accelerated degradation. In a 5-cell stack, open circuit voltage (OCV) of all cells remained constant after three full cycles (800–25 °C). Power output is little affected by air flow but markedly influenced by small fuel flow variation. Fuel utilisation reached 88% in one 5-cell stack test. Performance homogeneity between cells lay at ±4–8% for three different 5- or 6-cell stacks, but was poor for a 12-cell stack with respect to the border cells. Degradation of a 1-cell stack operated for 5500 h showed clear dependence on operating conditions (cell voltage, fuel conversion), believed to be related to anode reoxidation (Ni). A 6-cell stack (50 cm2 cells) delivering 100 Wel at 790 °C (1 kWel L−1 or 0.34 W cm−2) went through a fuel supply interruption and a thermal cycle, with one out of the six cells slightly underperforming after these events. This cell was eventually responsible (hot spot) for stack failure.  相似文献   

2.
《Journal of power sources》2004,137(2):206-215
We evaluated the performance of system combining a solid oxide fuel cell (SOFC) stack and a polymer electrolyte fuel cell (PEFC) stack by a numerical simulation. We assume that tubular-type SOFCs are used in the SOFC stack. The electrical efficiency of the SOFC–PEFC system increases with increasing oxygen utilization rate in the SOFC stack. This is because the amount of exhaust heat of the SOFC stack used to raise the temperature of air supplied to it decreases as its oxygen utilization rate increases and because that used effectively as the reaction heat of the steam reforming reaction of methane in the stack reformer increases. The electrical efficiency of the SOFC–PEFC system at 190 kW ac is 59% (LHV), which is equal to that of the SOFC-gas turbine combined system at 1014 kW ac.  相似文献   

3.
An experimental analysis was conducted on a 30 kW fuel cell power train with the aim to elucidate specific concerns of dynamic behaviour of hydrogen fuel cells in automotive applications. The study was conducted on a dynamic test bench able to simulate the behaviour of the reference vehicle, a minibus for historical centres collective service, on predefined driving cycle. The transient performance of the fuel cell system was firstly investigated without electric drive, using as load electric resistances electronically controlled. Experimental data were collected during warmup phases characterized by two acceleration slopes (150 W/s and 1500 W/s) and during a sequence of dynamic test cycles characterized by a very high acceleration slope of about 6 kW/s. The role of reactant feeding, humidification and cooling systems was investigated during all tests evaluating the performance during the transient steps in terms of cell voltage uniformity, expressed by the coefficient of variation Cv, used as statistical indicator. A driving cycle characterized by stop-and-go pattern and acceleration slopes compatible with a real utilization of the reference vehicle was finally adopted for tests on the overall power train. The results demonstrated a very good dynamic performance of the fuel cell stack as evidenced by the analysis of Cv, which resulted lower than 2.5% in all investigated working conditions, and by the overall power train efficiency which resulted about 30% with fuel cell system efficiency close to 50%.  相似文献   

4.
《Journal of power sources》2006,159(2):1042-1047
The direct methanol fuel cell (DMFC) is regarded as a promising candidate in portable electronic power applications. Bipolar plate stacks were systematically studied by controlling the operating conditions, and by adjusting the stack structure design parameters, to develop more commercial DMFCs. The findings indicate that the peak power of the stack is influenced more strongly by the flow rate of air than by that of the methanol solution. Notably, the stack performance remains constant even as the channel depth is decreased from 1.0 to 0.6 mm, without loss of the performance in each cell. Furthermore, the specific power density of the stack was increased greatly from ∼60 to ∼100 W l−1 for stacks of 10 and 18 cells, respectively. The current status of the work indicates that the power output of an 18-cell short stack reaches 33 W in air at 70 °C. The outer dimensions of this 18-cell short stack are only 80 mm × 80 mm × 51 mm, which are suitable for practical applications in 10–20 W DMFC portable systems.  相似文献   

5.
《Journal of power sources》2006,158(1):446-454
Implementation of polymer electrolyte fuel cells (PEMFCs) for stationary power applications requires the demonstration of reliable fuel cell stack life. One of the most critical components in the stack and that most likely to ultimately dictate stack life is the membrane electrode assembly (MEA). This publication reports the results of a 26,300 h single cell life test operated with a commercial MEA at conditions relevant to stationary fuel cell applications. In this experiment, the ultimate MEA life was dictated by failure of the membrane. In addition, the performance degradation rate of the cell was determined to be between 4 and 6 μV h−1, at the operating current density of 800 mA cm−2. AC impedance analysis and DC electrochemical tests (cyclic voltammetry and polarization curves) were performed as diagnostics during and on completion the test, to understand materials changes occurring during the test. Post mortem analyses of the fuel cell components were also performed.  相似文献   

6.
This paper deals with the energy optimization of an embedded fuel cell generator. To reach this aim, experimentally validated models of a low power 5 kW proton exchange membrane fuel cell (PEMFC) and its most power hungry ancillary (motor-compressor group) are described. All simulation results have been performed using Matlab/Simulink® environment. Moreover, a control strategy of the air supply circuit integrated in an embedded fuel cell system is proposed. The air flow control of the air supply circuit is built around a fuzzy PD + I controller and for the air supply set point determination, a fuzzy supervision is proposed. The parameters of this fuzzy supervision have been optimized thanks to particle swarm optimization (PSO) method.  相似文献   

7.
《Journal of power sources》2004,128(2):231-238
The Nexa™ power module is evaluated at membrane-electrode-assembly (MEA) and stack levels. The I–V Curves of the Nexa™ PEM fuel cell system is measured using periodic current interruption to maintain isothermal stack temperature. The uniformity analysis is mainly performed on the load of 800 W for all MEAs in 10 individual Nexa™ stacks. Statistical data show that the MEA voltage without an external load averages 224 mV higher than that with a load of 800 W. The MEA voltage difference is especially pronounced around the two cells at the air compressor side. The average difference is 8.8% and the highest difference is 13.1% between the minimum MEA voltage in the stack and the mean value. This voltage difference reveals a possibility to increase the product power capability and cut the cost per kilowatts by improving the weak performance electrodes or MEAs in the stack.  相似文献   

8.
《Journal of power sources》2006,162(2):1265-1269
A 75-kW methanol reforming fuel cell system, which consists of a fuel cell system and a methanol auto-thermal reforming fuel processor has been developed at Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS). The core of the fuel cell system is a group of CO tolerant PEMFC stacks with a double layer composite structured anode. The fuel cell stacks show good CO tolerance even though 140 ppm CO was present in the reformate stream during transients. The auto-thermal reforming (ATR) fuel cell processor could adiabatically produce a suitable reformate without external energy consumption. The output of hydrogen-rich reformate was approximately 120 N m3 h−1 with a H2 content near 53% and the CO concentrations generally were under 30 ppm. The fuel cell system was integrated with the methanol reforming fuel processor and the peak power output of the fuel cell system exceeded 75 kW in testing. The hydrogen utilization approached 70% in the fuel cell system.  相似文献   

9.
《Journal of power sources》2005,144(1):107-112
Research and development was conducted on a proton exchange membrane (PEM) fuel cell stack to demonstrate the capabilities of Ionomem Corporation's composite membrane to operate at 120 °C and ambient pressure for on-site electrical power generation with useful waste heat. The membrane was a composite of polytetrafluoroethylene (PTFE), Nafion®, and phosphotungstic acid. Studies were first performed on the membrane, cathode catalyst layer, and gas diffusion layer to improve performance in 25 cm2, subscale cells. This technology was then scaled-up to a commercial 300 cm2 size and evaluated in multi-cell stacks. The resulting stack obtained a performance near that of the subscale cells, 0.60 V at 400 mA cm−2 at near 120 °C and ambient pressure with hydrogen and air reactants containing water at 35% relative humidity. The water used for cooling the stack resulted in available waste heat at 116 °C. The performance of the stack was verified. This was the first successful test of a higher-temperature, PEM, fuel-cell stack that did not use phosphoric acid electrolyte.  相似文献   

10.
《Journal of power sources》2005,144(2):312-318
The University of Duisburg-Essen and the Center for Fuel Cell Technology (ZBT Duisburg GmbH) have developed a compact multi-fuel steam reformer suitable for natural gas, propane and butane. Fuel processor prototypes based on this concept were built up in the power range from 2.5 to 12.5 kW thermal hydrogen power for different applications and different industrial partners. The fuel processor concept contains all the necessary elements, a prereformer step, a primary reformer, water gas shift reactors, a steam generator, internal heat exchangers, in order to achieve an optimised heat integration and an external burner for heat supply as well as a preferential oxidation step (PrOx) as CO purification. One of the built fuel processors is designed to deliver a thermal hydrogen power output of 2.5 kW according to a PEM fuel cell stack providing about 1 kW electrical power and achieves a thermal efficiency of about 75% (LHV basis after PrOx), while the CO content of the product gas is below 20 ppm. This steam reformer has been combined with a 1 kW PEM fuel cell. Recirculating the anodic offgas results in a significant efficiency increase for the fuel processor. The gross efficiency of the combined system was already clearly above 30% during the first tests. Further improvements are currently investigated and developed at the ZBT.  相似文献   

11.
《Journal of power sources》2004,129(2):143-151
A control strategy is presented in this paper which is suitable for miniature hydrogen/air proton-exchange membrane (PEM) fuel cells. The control approach is based on process modelling using fuzzy logic and tested using a PEM stack consisting of 15 cells with parallel channels on the cathode side and a meander-shaped flow-field on the anode side. The active area per cell is 8 cm2. Commercially available materials are used for the bipolar plates, gas diffusion layers and the membrane-electrode assembly (MEA). It is concluded from a simple water balance model that water management at different temperatures can be achieved by controlling the air stoichiometry. This is achieved by varying the fan voltage for the air supply of the PEM stack. A control strategy of the Takagi Sugeno Kang (TSK) type, based on fuzzy logic, is presented. The TSK-type controller offers the advantage that the system output can be computed in an efficient way: the rule consequents of the controller combine the system variables in linear equations. It is shown experimentally that drying out of the membrane at high temperatures can be monitored by measuring the ac impedance of the fuel cell stack at a frequency of 1 kHz. Flooding of single cells leads to an abrupt drop of the corresponding single-cell voltage. Therefore, the fuzzy rule base consists of the ac impedance at 1 kHz and all single-cell voltages. The parameters of the fuzzy rule base are determined by plotting characteristic diagrams of the fuel cell stack at constant temperatures. The fuel cell stack can be controlled at T=60 °C up to a power level of 7.5 W. The fuel cell stack is controlled successfully even when the external electric load changes. At T=65 °C, a maximum power level of 8 W is found. A decrease of the maximum power level is observed for higher temperatures.  相似文献   

12.
《Journal of power sources》2006,159(1):478-483
This study reports the development of planar-type solid oxide fuel cell (SOFC) stacks based on an internal gas manifold and a cross-flow type design. A single-columned, 3-cell, SOFC stack is assembled using 10 cm × 10 cm anode-supported unit cells, metallic interconnects and glass-based compression-seal gaskets. The power-generating characteristics of the unit cell and stack are characterized as a function of temperature. The practical viability of the stack and stack components is investigated via long-term operation and thermal cycling tests. According to performance evaluation at 700 °C, the short stack produces about 100 W in total power at an average cell voltage of around 0.7 V. There are, however, some scale-up problems related to multi-cell stacking. This work addresses key issues in stack fabrication and performance improvement.  相似文献   

13.
《Journal of power sources》2004,128(2):152-164
Following the development of a 10 kW-class MCFC stack with a reactive area of 0.44 and 1.03 m2, which applies a Li/Na carbonate electrolyte and a press stamping separator, many tests have now been carried out. In the installation tests, the observed cell voltages of the 0.44 m2/10 kW-class stack agreed with the voltage predicted from the test results of the 100 cm2 bench scale cell. This agreement proves that the installing procedure of the bench scale cell can be applied to the 0.44 m2/10 kW-class stacks. The temperature distribution analysis model applied to the 100 kW-class stack was modified to calculate the temperature distribution of the 0.44 m2/10 kW-class stack. Taking the heat loss and the heat transfer effect of the stack holder into account, the calculated temperature was close to the measured temperature; this result proves that the modification was adequate for the temperature analysis model. In the high current density operating tests on the 0.44 m2/10 kW-class stack, an electrical power density of 2.46 kW/m2 was recorded at an operating current density of 3000 A/m2. In the endurance test on the 0.44 m2/10 kW-class stack, however, unexpected Ni shortening occurred during the operating period 2500–4500 h, which had been caused by a defective formation of the electrolyte matrix. The shortening seems to have been caused by the crack, which appeared in the electrolyte matrix. The voltage degradation rate of the 0.44 m2/10 kW-class stack was 0.52% over 1000 h, which proves that the matrix was inadequate for a long life expectancy of the MCFC stack. A final endurance test was carried out on the 1.03 m2/10 kW-class stack, of which the matrix had been revised. The fuel utilisation and the leakage of anode gas never changed during the 10,000 h operating test. This result suggests that no shortening occurred during the 10,000 h endurance test. The cell voltage degradation rate was around 0.2–0.3% over 1000 h in the 1.03 m2/10 kW-class stack. According to a comparison of the stack electricity generating performance of the 0.44 m2 and the 1.03 m2/10 kW-class stack under the same operating conditions, the performance of the 1.03 m2 stack was lower at the beginning of the endurance test, however, its performance exceeded the performance of the 0.44 m2/10 kW-class stack during the 10,000 h operating test. By carrying out the high current density operating test and the 10,000-hour endurance test using commercial sized 10 kW-class stacks, the stability of the MCFC stack with a Li/Na carbonate electrolyte and a press stamping separator has been proven.  相似文献   

14.
15.
《Journal of power sources》2006,155(2):203-212
The characteristics of a 50 W direct methanol fuel cell (DMFC) stack were investigated under various operating conditions in order to understand the behavior of the stack. The operating variables included the methanol concentration, the flow rate and the flow direction of the reactants (methanol and air) in the stack. The temperature of the stack was autonomously increased in proportion to the magnitude of the electric load, but it decreased with an increase in the flow rates of the reactants. Although the operation of the stack was initiated at room temperature, under a certain condition the internal temperature of the stack was higher than 80 °C. A uniform distribution of the reactants to all the cells was a key factor in determining the performance of the stack. With the supply of 2 M methanol, a maximum power of the stack was found to be 54 W (85 mW cm−2) in air and 98 W (154 mW cm−2) in oxygen. Further, the system with counter-flow reactants produced a power output that was 20% higher than that of co-flow system. A post-load behavior of the stack was also studied by varying the electric load at various operating conditions.  相似文献   

16.
《Journal of power sources》2006,157(1):253-259
A passive, air-breathing, monopolar, liquid feed direct methanol fuel cell (DMFC) stack consisting of six unit cells with no external pump, fan or auxiliary devices to feed the reactants has been designed and fabricated for its possible employment as a portable power source. The configurations of the stack of monopolar passive feed DMFCs are different from those of bipolar active feed DMFCs and therefore its operational characteristics completely vary from the active ones. Our present investigation primarily focuses on understanding the unique behavioral patterns of monopolar stack under the influence of certain operating conditions, such as temperature, methanol concentration and reactants feeding methods. With passive reactants supply, the temperature of the stack and open circuit voltage (OCV) undergo changes over time due to a decrease in concentration of methanol in the reservoir as the reaction proceeds. Variations in performance and temperature of the stack are mainly influenced by the concentration of methanol. Continuous operation of the passive stack is influenced by the supply of methanol rather than air supply or water accumulation at the cathode. The monopolar stack made up of six unit cells exhibits a total power of 1000 mW (37 mW cm−2) with 4 M methanol under ambient conditions.  相似文献   

17.
《Journal of power sources》2005,144(1):146-151
The life performance must be improved in order to commercialize polymer electrolyte fuel cells (PEFC). A decline of the cell voltage has been found to result from deterioration of the materials and a localization of reaction in the cell. We investigated the localization phenomenon, measuring the current density in the cell. The distribution of current density was measured by divided and isolated electrodes for a long period of operation. At the beginning of generation of electricity, a high current region is observed in the lower gas channel which is relatively humid. However, the high current region gradually moves to the upper dry channel in proportion to the voltage drop, which is remarkable under conditions of low humidity operation. This reaction seems to be reversible, since the PEFC can mostly recover the initial performance, once it is restarted. Improving the MEA and gas separators for low humidified conditions on the basis of this internal analysis, we operated a 20 cells PEFC stack of 0.4 kW for 5000 h and the stack showed −1.5 mV/1000 h of average voltage degradation.  相似文献   

18.
《Journal of power sources》2002,112(1):261-272
The ohmic voltage loss in a fuel cell can be determined with the current interruption method. The method was utilized to measure the ohmic voltage loss in an individual cell of a fuel cell stack. This was achieved by producing voltage transients and monitoring them with a digital oscilloscope connected in parallel with the individual cell. In this study, the method was applied to a small polymer electrolyte membrane fuel cell (PEMFC) stack in which different air supply levels were employed on the cathode side. In the case of higher air-feed rate, the results revealed an increase of ohmic losses in the middle of the stack by up to 21% at 400 mA cm−2, compared to the unit cell with the lowest ohmic loss. This probably resulted from the decrease of membrane conductivity because of drying. Comparison to individual cell voltages showed that the decrease of conductivity would not be observed if only the individual cell voltages alone were measured. The total ohmic loss in the stack was measured using the same method to verify the reliability of the measurement system. The results indicate a good agreement between the total ohmic loss and the combined ohmic losses in the individual cells.  相似文献   

19.
《Journal of power sources》2006,154(2):479-488
An auxiliary power unit (APU) is presented that is fuelled with diesel, thermally self-sustaining, and based on a solid oxide fuel cell (SOFC). The APU is rated at 1 kW electrical, and can generate electrical power after a 3 h warm-up phase. System features include a “dry” catalytic partial oxidation (CPOX) diesel reformer, a 30 cell SOFC stack with an open cathode, and a porous-media afterburner. The APU does not require a supply of external water. The SOFC stack is an outcome of a development partnership with H.C. Starck GmbH and Fraunhofer IKTS, and is discussed in detail in an accompanying paper.  相似文献   

20.
A small combined cold and power (SCCP) system is presented. An experimental study of the performance of the SCCP system is described. The gas fuelled SCCP system uses a micro gas turbine generator set and an absorption chiller. The test facility designed and built is also described. The rated electricity power of the micro gas turbine generator is about 24.5 kW at the experimental conditions. When exhaust gas from the micro gas turbine is used to drive the absorption chiller, the rated cooling capacity is 52.7 kW without supplying fuel to burn in the absorption chiller and 136.2 kW with supplying about 78.9 kW LPG fuel to burn in the absorption chiller, respectively. Primary energy rate (PER) and comparative saving of primary energy demand are used to evaluate the performance of the SCCP system. PER of the SCCP system decreases rapidly with the decrease of electric power output when the electric power output is less than 10 kW. The calculated results also show that comparative saving of primary energy demand of the SCCP system decreases with the decrease of electric power output and the SCCP system do not save primary energy comparing to conventional energy system when the electric power output is less than 10 kW.  相似文献   