首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In spite of the high-performance characteristics of a solid oxide fuel cell/gas turbine (SOFC/GT) hybrid system, it is difficult to maintain high-level performance under real application conditions, which generally require part-load operations. The efficiency loss of the SOFC/GT hybrid system under such conditions is closely related to that of the gas turbine. The power generated by the gas turbine in a hybrid system is much less than that generated by the SOFC, but its contribution to the efficiency of the system is important, especially under part-load conditions. Over the entire operating load profile of a hybrid system, the efficiency of the hybrid system can be maximized by increasing the contribution of power coming from the high efficiency component, namely the fuel cell. In this study, part-load control strategies using air-bypass valves are proposed, and their impact on the performance of an SOFC/GT hybrid system is discussed. It is found that air-bypass modes with control of the fuel supply help to overcome the limits of the part-load operation characteristics in air/fuel control modes, such as variable rotational speed control and variable inlet guide vane control.  相似文献   

2.
The purpose of this study is to compare the part-load performance of a solid oxide fuel cell/gas turbine (SOFC/GT) hybrid system in three different control modes: fuel-only control, rotational speed control, and variable inlet guide vane (VIGV) control. While the first mode maintains a constant air supply and reduces the supplied fuel to achieve part-load operation, the other modes are distinguished by the simultaneous controls of the air and fuel supplied to the system. After the performance analysis of a SOFC/GT hybrid system under part-load operating conditions, it was concluded that the rotational speed control mode provided the best performance characteristics for part-load operations. In spite of worse performance than the rotational speed control mode, the VIGV control mode can be a good candidate for part-load operation in a large-scale hybrid system in which the rotational speed control is not applicable. It was also found that, in spite of a relatively small contribution to the total system power generation, the gas turbine plays an important role in part-load operation of a SOFC/GT hybrid system.  相似文献   

3.
A theoretical solid oxide fuel cell–gas turbine hybrid system has been designed using a Capstone 60 kW micro-gas turbine. Through simulation it is demonstrated that the hybrid system can be controlled to achieve transient capability greater than the Capstone 60 kW recuperated gas turbine alone. The Capstone 60 kW gas turbine transient capability is limited because in order to maintain combustor, turbine and heat exchangers temperatures within operating requirements, the Capstone combustor fuel-to-air ratio must be maintained. Potentially fast fuel flow rate changes, must be limited to the slower, inertia limited, turbo machinery air response. This limits a 60 kW recuperated gas turbine to transient response rates of approximately 1 kW s−1. However, in the SOFC/GT hybrid system, the combustor temperature can be controlled, by manipulating the fuel cell current, to regulate the amount of fuel sent to the combustor. By using such control pairing, the fuel flow rate does not have to be constrained by the air flow in SOFC/GT hybrid systems. This makes it possible to use the rotational inertia of the gas turbine, to buffer the fuel cell power response, during fuel cell fuel flow transients that otherwise limit fuel cell system transient capability. Such synergistic integration improves the transient response capability of the integrated SOFC gas turbine hybrid system. Through simulation it has been demonstrated that SOFC/GT hybrid system can be developed to have excellent transient capability.  相似文献   

4.
Design characteristics and performance of a pressurized solid oxide fuel cell (SOFC) hybrid system using a fixed gas turbine (GT) design are analyzed. The gas turbine is assumed to exist prior to the hybrid system design and all the other components such as the SOFC module and auxiliary parts are assumed to be newly designed for the hybrid system. The off-design operation of the GT is modeled by the performance characteristics of the compressor and the turbine. In the SOFC module, internal reforming with anode gas recirculation is adopted. Variations of both the hybrid system performance and operating condition of the gas turbine with the design temperature of the SOFC were investigated. Special focus is directed on the shift of the gas turbine operating points from the original points. It is found that pressure loss at the fuel cell module and other components, located between the compressor and the turbine, shifts the operating point. This results in a decrease of the turbine inlet temperature at each compressor operating condition relative to the original temperature for the GT only system. Thus, it is difficult to obtain the original GT power. Two cell voltage cases and various degrees of temperature difference at the cell are considered and their influences on the system design characteristics and performance are comparatively analyzed.  相似文献   

5.
This paper presents the work on the design and part-load operations of a hybrid power system composed of a pressurized molten carbonate fuel cell (MCFC) and a micro-gas turbine (MGT). The gas turbine is an existing one and the MCFC is assumed to be newly designed for the hybrid system. Firstly, the MCFC power and total system power are determined based on the existing micro-gas turbine according to the appropriate MCFC operating temperature. The characteristics of hybrid system on design point are shown. And then different control methods are applied to the hybrid system for the part-load operation. The effect of different control methods is analyzed and compared in order to find the optimal control strategy for the system. The results show that the performance of hybrid system during part-load operation varies significantly with different control methods. The system has the best efficiency when using variable rotational speed control for the part-load operation. At this time both the turbine inlet temperature and cell operating temperature are close to the design value, but the compressor would cross the surge line when the shaft speed is less than 70% of the design shaft speed. For the gas turbine it is difficult to obtain the original power due to the higher pressure loss between compressor and turbine.  相似文献   

6.
Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10 MW gas turbine power plant, operating at 30% efficiency in order to improve system efficiencies and economics. The SOFC system is semi-directly coupled to the gas turbine power plant, with careful attention paid to minimize the disruption to the GT operation. A thermo-economic model is developed for the hybrid power plant, and predicts an optimized power output of 21.6 MW at 49.2% efficiency. The model also predicts a breakeven per-unit energy cost of USD 4.70 ¢/kWh for the hybrid system based on futuristic mass generation SOFC costs. Results show that SOFCs can be semi-directly integrated into existing GT power systems to improve their thermodynamic and economic performance.  相似文献   

7.
In this paper, the performance evaluation of a solid oxide fuel cell (SOFC)–micro gas turbine (MGT) hybrid power generation system under the part-load operation was studied numerically. The present analysis code includes distributed parameters model of the cell stack module. The conversions of chemical species for electrochemical process and fuel reformation process are considered. Besides the temperature distributions of the working fluids and each solid part of cell module by accounting heat generation and heat transfers, are taken into calculation. Including all of them, comprehensive energy balance in the cell stack module is calculated. The variable MGT rotational speed operation scheme is adopted for the part-load operation. It will be made evident that the power generation efficiency of the hybrid system decreases together with the power output. The major reason for the performance degradation is the operating temperature reduction in the SOFC module, which is caused by decreasing the fuel supply and the heat generation in the cells. This reduction is also connected to the air flow rate supplement. The variable MGT rotational speed control requires flexible air flow regulations to maintain the SOFC operating temperature. It will lead to high efficient operation of the hybrid system.  相似文献   

8.
Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10 MW gas turbine power plant, operating at 30% efficiency, in order to improve system efficiencies and economics. The SOFC system is indirectly coupled to the gas turbine power plant, paying careful attention to minimize the disruption to the GT operation. A thermo-economic model is developed for the hybrid power plant, and predicts an optimized power output of 20.6 MW at 49.9% efficiency. The model also predicts a break-even per-unit energy cost of USD 4.65 ¢ kWh−1 for the hybrid system based on futuristic mass generation SOFC costs. This shows that SOFCs may be indirectly integrated into existing GT power systems to improve their thermodynamic and economic performance.  相似文献   

9.
《Journal of power sources》2006,160(1):462-473
This study presents critical aspects and their influence on the performance of hybrid power systems combining a pressurized solid oxide fuel cell (SOFC) and a gas turbine (GT). Two types of hybrid system configurations with internal and external reforming have been analyzed. In order to examine the effect of matching between the fuel cell temperature and the turbine inlet temperature on the hybrid system performance, we considered air bypass after the compressor as well as additional fuel supply to the turbine side. This study focuses on the limitation of the temperature difference at the fuel cell stack and its influence on the performances of the two hybrid systems. Performances of the hybrid systems are also compared with those of simple SOFC systems, and the extent of performance enhancement is evaluated. The system with internal reforming gives better efficiency and power capacity for all design conditions than the system with external reforming under the same constraints. Its efficiency gain over the SOFC only system is considerable, while that of the system with external reforming is far less. As the temperature difference at the cell becomes smaller, the system performance generally degrades. The system with internal reforming is less influenced by the constraint of the cell temperature difference.  相似文献   

10.
Current work on the performance of a solid oxide fuel cell (SOFC) and gas turbine hybrid system is presented. Each component model developed and applied is mathematically defined. The electrochemical performance of single SOFC with different fuels is tested. Experimental results are used to validate the SOFC mathematical model. Based on the simulation model, a safe operation regime of the hybrid system is accurately plotted first. Three different part-load strategies are introduced and used to analyze the part-load performance of the hybrid system using the safe regime. Another major objective of this paper is to introduce a suitable startup and shutdown strategy for the hybrid system. The sequences for the startup and shutdown are proposed in detail, and the system responses are acquired with the simulation model. Hydrogen is used instead of methane during the startup and shutdown process. Thus, the supply of externally generated steam is not needed for the reforming reaction. The gas turbine is driven by complementary fuel and supplies compressed air to heat up or cool down the SOFC stack operating temperature. The dynamic simulation results show that smooth cooling and heating of the cell stack can be accomplished without external electrical power.  相似文献   

11.
A novel solid oxide fuel cell (SOFC)/gas turbine (GT) hybrid cycle system with CO2 capture is proposed based on a typical topping cycle SOFC/GT hybrid system. The H2 gas is separated from the outlet mixture gas of SOFC1 anode by employing the advanced ceramic proton membrane technology, and then, it is injected into SOFC2 to continue a new electrochemical reaction. The outlet gas of SOFC1 cathode and the exhaust gas from SOFC2 burn in the afterburner 1. The combustion gas production of the afterburner1 expands in the turbine 1. The outlet gas of SOFC1 anode employs the oxy‐fuel combustion mode in the afterburner 2 after H2 gas is separated. Then, the combustion gas production expands in the turbine 2. To ensure that the flue gas temperature does not exceed the maximum allowed turbine inlet temperature, steam is injected into the afterburner 2. The outlet gas of the afterburner 2 contains all the CO2 gas of the system. When the steam is removed by condensation, the CO2 gas can be captured. The steam generated by the waste heat boiler is used to drive a refrigerator and make CO2 gas liquefied at a lower temperature. The performance of the novel quasi‐zero CO2 emission SOFC/GT hybrid cycle system is analyzed with a case study. The effects of key parameters, such as CO2 liquefaction temperature, hydrogen separation rate, and the unit oxygen production energy consumption on the new system performance, are investigated. Compared with the other quasi‐zero CO2 emission power systems, the new system has the highest efficiency of around 64.13%. The research achievements will provide the valuable reference for further study of quasi‐zero CO2 emission power system with high efficiency. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
This paper focuses on novel integration of high temperature solid oxide fuel cell coupled with recuperative gas turbine (with air-film cooling of blades) based hybrid power plant (SOFC-blade cooled GT). For realistic analysis of gas turbine cycle air-film blade cooling technique has been adopted. First law thermodynamic analysis investigating the combine effect of film cooling of blades, SOFC, applied to a recuperated gas turbine cycle has been reported. Thermodynamic modeling for the proposed cycle has been presented. Results highlight the influence of film cooling of blades and operating parameters of SOFC on various performance of SOFC-blade cooled GT based hybrid power plant. Moreover, parametric investigation has also been done to examine the effect of compressor pressure ratio, turbine inlet temperature, on hybrid plant efficiency and plant specific work. It has been found that on increasing turbine inlet temperature (TIT) beyond a certain limit, the efficiency of gas turbine starts declining after reaching an optimum value which is compensated by continuous increase in SOFC efficiency with increase in operating temperature. The net result is higher performance of hybrid cycle with increase in maximum cycle temperature. Furthermore, it has been observed that at TIT 1600 K and compression ratio 20, maximum efficiency of 73.46% can been achieved.  相似文献   

13.
《Journal of power sources》2006,158(1):225-244
This paper presents a full and partial load exergy analysis of a hybrid SOFC–GT power plant. The plant basically consists of: an air compressor, a fuel compressor, several heat exchangers, a radial gas turbine, mixers, a catalytic burner, an internal reforming tubular solid oxide fuel cell stack, bypass valves, an electrical generator and an inverter. The model is accurately described. Special attention is paid at the calculation of SOFC overpotentials. Maps are introduced, and properly scaled, in order to evaluate the partial load performance of turbomachineries. The plant is simulated at full-load and part-load operation, showing energy and exergy flows trough all its components and thermodynamic properties at each key-point. At full-load operation a maximum value of 65.4% of electrical efficiency is achieved. Three different part-load strategies are introduced. The off-design operation is achieved handling the following parameters: air mass flow rate, fuel mass flow rate, combustor bypass, gas turbine bypass, avoiding the use of a variable speed control system. Results showed that the most efficient part-load strategy corresponded to a constant value of the fuel to air ratio. On the other hand, a lower value of net electrical power (34% of nominal load) could be achieved reducing fuel flow rate, at constant air flow rate. This strategy produces an electrical efficiency drop that becomes 45%.  相似文献   

14.
An energy analysis of three typical solid oxide fuel cell (SOFC) power systems fed by methane is carried out with detailed thermodynamic model. Simple SOFC system, hybrid SOFC‐gas turbine (GT) power system, and SOFC‐GT‐steam turbine (ST) power system are compared. The influences of air ratio and operative pressure on the performance of SOFC power systems are investigated. The net system electric efficiency and cogeneration efficiency of these power systems are given by the calculation model. The results show that internal reforming SOFC power system can achieve an electrical efficiency of more than 49% and a system cogeneration efficiency including waste heat recovery of 77%. For SOFC‐GT system, the electrical efficiency and cogeneration efficiency are 61% and 80%, respectively. Although SOFC‐GT‐ST system is more complicated and has high investment costs, the electrical efficiency of it is close to that of SOFC‐GT system. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
《Journal of power sources》2006,158(1):303-315
This paper presents a multi-loop control strategy for a SOFC/GT hybrid system. A detailed dynamic model of the system is presented and its part-load performance is studied. The control objectives are discussed, with the main issue being a fairly constant fuel cell temperature under all conditions. Based on the system configuration and part-load performance, input and output variables of the control system are detected. Control cycles are introduced and their design is discussed. The responses of the resulting system on load changes, external disturbances as well as malfunction and degradation incidents are investigated. The system is stable under all incidents. An error in fuel flow measurement or assumed fuel quality provokes a steady-state fuel cell temperature offset. For a degraded system, it may be advisable to readjust the control system to the new characteristics.  相似文献   

16.
Power generation using gas turbine (GT) power plants operating on the Brayton cycle suffers from low efficiencies, resulting in poor fuel to power conversion. A solid oxide fuel cell (SOFC) is proposed for integration into a 10-MW GT power plant, operating at 30% efficiency, in order to improve system efficiencies and economics. The SOFC system is indirectly coupled to the GT, in order to minimize the disruption to the GT operation. A thermo-economic model is developed to simulate the hybrid power plant and to optimize its performance using the method of Lagrange Multipliers. It predicts an optimized power output of 18.9 MW at 48.5% efficiency, and a breakeven per-unit energy cost of USD 4.54 ¢ kW h−1 for the hybrid system based on futuristic mass generation SOFC costs.  相似文献   

17.
We present a steady‐state thermodynamic model of a hybrid solid oxide fuel cell (SOFC)–gas turbine (GT) cycle developed using a commercial process simulation software, AspenPlus?. The hybrid cycle model incorporates a zero‐dimensional macro‐level SOFC model. A parametric study was carried out using the developed model to study the effects of system pressure, SOFC operating temperature, turbine inlet temperature, steam‐to‐carbon ratio, SOFC fuel utilization factor, and GT isentropic efficiency on the specific work output and efficiency of a generic hybrid cycle with and without anode recirculation. The results show that system pressure and SOFC operating temperature increase the cycle efficiency regardless of the presence of anode recirculation. On the other hand, the specific work decreases with operating temperature. Overall, the model can successfully capture the complex performance trends observed in hybrid cycles. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
Solid oxide fuel cell (SOFC) is characterized in high performance and high temperature exhaust, and it has potential to reach 70% efficiency if combined with gas turbine engine (GT). Because the SOFC is in developing stage, it is too expensive to obtain. This paper proposes a feasibility study by using a burner (Comb A) to simulate the high temperature exhaust gas of SOFC. The second burner (Comb B) is connected downstream of Comb A, and preheated hydrogen is injected to simulate the condition of sequential burner (SeqB). A turbocharger and a water injection system are also integrated in order to simulate the situation of a real SOFC/GT hybrid system. The water injection system is used to simulate the water mist addition at external reformer.  相似文献   

19.
In a global energetic context characterized by the increasing demand of oil and gas, the depletion of fossil resources and the global warming, more efficient energy systems and, consequently, innovative energy conversion processes are urgently required. A possible solution can be found in the fuel cells technology coupled with classical thermodynamic cycle technologies in order to make hybrid systems able to achieve high energy/power efficiency with low environmental impact. Moreover, due to the synergistic effect of using a high temperature fuel cell such as solid oxide fuel cell (SOFC) and a recuperative gas turbine (GT), the integrated system efficiency can be significantly improved. In this paper a steady zero dimensional model of a SOFC/GT hybrid system is presented. The core of the work consists of a performance analysis focused on the influence of the GT part load functioning on the overall system efficiency maintaining the SOFC power set to the nominal one. Also the proper design and management of the heat recovery section is object of the present study, with target a global electric efficiency almost constant in part load functioning respect to nominal operation. The results of this study have been used as basis to the development of a dynamic model, presented in the following part of the study focused on the plant dynamic analysis.  相似文献   

20.
This paper mainly studied the solid oxide fuel cell (SOFC)–micro gas turbine (MGT) hybrid power system. The key parameters that greatly influence the overall system performance have been studied and optimized. The thermodynamic potential of improving the hybrid system performance by integrating SOFC with the advanced thermal cycle system is analyzed. The optimization rules of main parameters of SOFC‐MGT hybrid power system with the turbine inlet temperature (TIT) of MGT as a constraint condition are revealed. The research results show that TIT is a key parameter that limits the electrical efficiency of hybrid power system. With the increase of the cell number, both the power generation efficiency of the hybrid cycle power system and TIT increase. Regarding the hybrid system with the fixed cell number, in order to get a higher electrical efficiency, the operating temperature of SOFC should be enhanced as far as possible. However, the higher operating temperature will result in the higher TIT. Increasing of fuel utilization factor is an effective measure to improve the performance of hybrid system. At the same time, TIT increases slightly. Both the electrical efficiency of hybrid power system and TIT reduce with the increase of the ratio of steam to carbon. The achievements obtained from this paper will provide valuable information for further study on SOFC‐MGT hybrid power system with high efficiency. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号