首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Daylighting has often been recognized as a useful source of energy savings and visual comforts in buildings. Occupants expect good daylight in their working spaces. The quality and quantity of natural light entering a building depend on both internal and external factors. In Hong Kong, commercial building accounts for the major building energy use and electric lighting is one of the major electricity-consuming items. This paper studies the daylighting performance and energy implications for office buildings. A total of 35 commercial buildings have been selected in the survey. Key building parameters affecting daylighting designs are presented. Two typical office blocks were further analysed based on a lighting simulation program. The daylighting performance was evaluated in terms of daylight factor, room depth and glare index. It has been found that the daylighting performance for office buildings is quite effective. About one-third of the office areas that are near the perimeter regions have an average daylight factor of 5%. For inner region of deep plan offices, some innovative daylighting systems such as light redirecting panels and light pipe could be used to improve the daylighting performance. In general, the office building envelop designs are conducive to effective daylighting and proper daylight linked lighting controls could save over 25% of the total electric lighting use.  相似文献   

2.
Daylighting has long been recognized as an important issue in architecture. In Hong Kong many buildings are constructed close to each other and hence the external environment plays a significant role in building designs. Recently, vertical daylight factor (VDF) has been used as a criterion to justify the provision of natural lighting in buildings. This paper studies the calculation approach of VDF in a heavily obstructed environment. The techniques for determining the sky component and the reflected daylight from surrounding buildings and ground surfaces are described. Calculation tools in the form of simple equations and diagrams through computer-simulation analysis were established. The performance of the proposed method was evaluated against the daylight illuminance obtained by other independent computer simulations. It was found that predictions from the proposed approach were in good agreements with those produced by simulated results. The findings provide architects and building designers with a simple method for estimating the daylight illuminance at early design and planning stage.  相似文献   

3.
《Energy and Buildings》2001,33(8):793-803
Lighting control integrated with daylighting is recognised as an important and useful strategy in energy-efficient building designs and operations. It is believed that proper daylighting schemes can help reduce the electrical demand and contribute to achieving environmentally sustainable building development. This paper presents field measurements on daylighting for a fully air-conditioned office building in Hong Kong. Electricity consumption by the fluorescent luminaires, indoor illuminance levels and the room parameters affecting daylighting designs were recorded and analysed. The measurements covered several cellular offices facing opposite orientations with and without daylighting controls. The findings suggest that daylighting schemes can result in substantial energy savings in air-conditioned office buildings in Hong Kong. Results are presented and the design implications are discussed.  相似文献   

4.
In a dense urban region in which high-rise buildings are packed inside limited land areas, the daylight components reflected from ground and surrounding buildings play significant roles in daylighting design. The natural light available in an interior strongly depends on the amount of daylight reaching the window facades. Lately we proposed a calculation procedure, presented in form of simple mathematical expressions and diagrams, to determine the daylight illuminance on a vertical plane under overcast skies. This paper extends the study to non-overcast sky conditions. The performance of the proposed method was evaluated by comparison with the daylight illuminance simulated by a lighting software, namely RADIANCE, and with measurements under real skies. It was found that the data estimated by the proposed method were in good agreement both with the values simulated by RADIANCE and with the measured results. The paper offers to architects and building engineers a useful tool for estimating the daylight illuminance and in particular for determining and assessing various daylighting schemes and concepts during design and construction stages.  相似文献   

5.
《Building and Environment》2005,40(7):973-982
Lighting control integrated with daylighting is recognised as an important and useful strategy in energy-efficient building designs and operations. Prediction of the internal daylight levels is a key stage in daylighting designs. With the advances in computer technology, the computation of daylight illuminances can be conducted via lighting simulation program. This paper presents a study of the daylight coefficient (DC) approach using RADIANCE lighting software in simulating the indoor daylight illuminance of a corridor. The interior daylight illuminance data measured in the corridor were compared with the simulated results based on the computer software. It was found that the DC approach could give satisfactory results especially for the sun-shaded surface and sun-facing surface receiving a large amount of direct sunlight. Further, the daylight illuminance detected by the photosensor was also simulated in conjunction with measured daylight illuminance, dimming ratio and electric lighting power to predict the lighting energy savings. The findings suggested that the measured and predicted data showed a good agreement when large electric lighting savings resulted. The probable reasons causing the discrepancies were discussed.  相似文献   

6.
Optical daylighting technology can deliver natural light to a space in a building where daylight is limited. This study gives an overview of two optical daylighting systems for capturing natural light: light pipe systems and mirror sunlighting systems. The literature on optical system theories and developments is identified and commercial products for optical daylighting systems on the market are described. By using a survey of major applications for optical daylighting systems, this study provides practical advice to building designers and researchers and also shows a light pipe system and a mirror sunlighting system developed from this investigation as well as an evaluation of their performance. The evaluation measured the illuminance of the two optical systems installed in a test room and a living room. This study concluded that optical daylighting systems can provide adequate visual comfort and can save energy if they are carefully designed.  相似文献   

7.
天然光环境更有利于人体健康与视觉舒适,这促使机场等大空间建筑对于天然采光设计的重视程度逐渐提高。比较广州新白云机场、深圳宝安机场T3航站楼两个大型机场的采光设计方案及其实际采光效果,文章旨在提出机场等大空间公共建筑采光设计应注意的问题以及设计原则。通过理论分析、现场测量、使用后评价等方法,研究两者在天然采光设计方面的优劣。经调研对比后发现开敞式大空间建筑使用集中式带型天窗不利于在整个室内实现均匀的天然光环境,而使用分散式平天窗更有利于营造均匀的天然光环境。  相似文献   

8.
Energy conservation in buildings is greatly influenced by natural daylight in tropical region. A vital step towards development and promotion of daylighting technology in buildings is a prior study on estimation of exterior daylight availability for illuminating its interiors. In view of this, the present communication depicts the preliminary work progress carried out to arrive at a comprehensive idea on assessment of daylight availability and its characteristics. The study is reported taking the representative case of Bangalore (India) (latitude 12.97° N, longitude 77.56° E),which in future work facilitates to device suitable interior illuminance models and lighting controls for a daylight-artificial light integrated scheme. The objective of this paper is to document the estimation of spatial exterior daylight parameters like exterior horizontal as well as vertical global and diffuse daylight illuminance in addition to their respective luminous efficacies computed using an established analytical model. The paper also highlights user friendly computer simulation tool developed, for the detailed estimation of daylight availability at a particular region by the inclusion of corresponding solar radiation data.  相似文献   

9.
谢浩 《门窗》2011,(6):58-61
通过科学的设计把天然光引入建筑已成为一种时尚,它不仅可以降低建筑能耗,还能利用阳光提高室内的环境质量.本文从四个方面探讨住宅建筑中的采光设计问题,包括室内天然光设计标准分析、采光窗对居室内部光环境的影响、天然采光系统主要技术手段的应用和住宅获得良好天然光的具体要求及其应注意的问题.  相似文献   

10.
Identified as one of the key issues in sustainable building designs, freshwater consumption is of primary importance to the design of water systems in buildings. Various benchmarks of water consumption have been developed for the indication and promotion of building sustainability; however, a simple normalization might require precise regional and timing adaptation while a complicated benchmarking model could impose extra adaptation difficulties. In this study, a simple epistemic benchmarking model for residential buildings was formed from existing domestic water consumption patterns and the latest regional survey results. In particular, with various prior estimates from reported water consumption worldwide, a water consumption survey of 60 apartments in Hong Kong was used to formulate a likelihood function for assessing the model validity. The posterior average consumption was compared with the Hong Kong global freshwater consumption patterns to derive the water consumption benchmarks for residential buildings in the region. This epistemic approach would be useful for evaluating the benchmarks of water consumption that is under continuous monitoring. The study also presented a template for formulating epistemic water consumption benchmarks for residential premises elsewhere.  相似文献   

11.
The atrium concept allows the exploitation of daylighting by bringing natural light into the center of the buildings, thus enhancing a more even distribution of daylight. The configuration of interior balconies, however, is determined based on the purpose of the interior space and the use of the building, which may defeat the primary daylighting advantages inherent in the atrium concept. The authors have developed insights regarding the critical daylighting performance factors by evaluating the relative effect of various interior balcony configurations on illumination level and its distribution with different atrium geometries. For these, parametric measurements of illumination level with a scale model of a four-sided atrium building and various interior balcony configurations have been conducted under diffuse sky conditions within the sky simulator at a Texas university. This paper represents the atrium performance results in terms of daylight factor, Well index, balcony Well index, the configuration of interior balcony; and the results are compared with basecase atria without any interior balcony. As expected, Well index and balcony depth are the most significant factors in daylighting performance in atrium spaces with interior balconies. For the position not covered by balcony, adequate illumination can be achieved for circulation regardless of building Well index and balcony depth although it may be that involved well indices are relatively low. On the other hand, light attenuation on the position under balcony floor is up to 70–90%, in particular, when the Well index becomes higher than 1 m and balcony floor becomes deeper than 3 m.  相似文献   

12.
The first step in evaluating the visual performance and energy efficiency provided by daylight requires an accurate estimation of the amount of daylight entering a building. The actual daylight illuminance of a room is mainly influenced by the luminance levels and patterns of the sky in the direction of view of the window at that time. The daylight coefficient concept, which considers the changes in the luminance of the sky elements, offers a more effective way of computing indoor daylight illuminances. Recently, Kittler et al. have proposed a new range of 15 standard sky luminance distributions including the CIE (International Commission on Illumination) standard clear sky. Lately, these 15 sky luminance models have been adopted as the CIE Standard General Skies. This paper presents a graphical method to calculate interior illuminance for the CIE standard clear sky using the daylight coefficient approach. The simplified techniques in the form of a nomograph and Waldram diagram were established and described. The performance of the proposed approach was evaluated against the results obtained by an independent calculation approach and a computer simulation program. It was shown that the daylight illuminances estimated by our graphical tool were in reasonably good agreement with those produced from the other two methods. The findings provide building professionals and students a reliable and simple alternative that incorporates the daylight coefficient concept to estimate the interior daylight illuminance and assess daylighting performance.  相似文献   

13.
The probable maximum flow rates and flushing water consumption of a residential development are two crucial design factors for flushing water plants and evaluation of the risk of overloading them. Flushing water demands are transient and influenced by occupant load variations, occupant usage patterns, installed appliances and system commissioning. This study proposes mathematical expressions to determine the water consumption and flow rates for flushing water systems of residential buildings in Hong Kong. The model parameters were identified from a recent survey on the water closet (WC) usage patterns of 14 high-rise residential buildings. The occupant load factor, diurnal variation of flushing, discharge and refilling durations and volume of the WC cistern recorded from 597 households were used to determine the uncertainties of consumption and flow rates, and hence the risk of overloading a plant. Predictions were made for two typical residential buildings in Hong Kong. Good agreement between the predicted and the measured flushing water consumption was found. This model would be useful in calculating the capacity of a flushing water plant and the associated risk of overloading it.  相似文献   

14.
The California Legislature mandated the California Energy Commission (CEC) to establish and periodically update energy efficiency standards for new buildings. To this end, a sensitivity analysis was conducted by the Standards Development Office of the California Energy Commission for nonresidential buildings. The purpose of this parametric analysis was to determine which variations in building parameters actually have significant energy impacts.A “generic” building model was developed and implemented in conducting this sensitivity analysis. The generic model was used as an analytical tool in modeling the energy impact of building parameter variations, as well as architectural and mechanical energy-saving measures on the energy use of each module. It is recognized that the level of significant energy impact is equivalent to, or bounded by the accuracy of the energy analysis tools in predicting energy usage in actual buildings. For the computer program used, DOE 2.1A this accuracy is within ±5%.Since DOE 2.1A and most of the other building energy simulation programs do not have daylighting algorithms, another calculation tool was used to determine daylight availability and lighting power reduction on an hour-by-hour basis for each orientation. This is accomplished with a daylight reduction factor (DRF).Quicklite, a simplified daylighting program, calculated footcandle (lux) levels based on outdoor ambient light levels, physical room dimensions and properties. To assess the impact of the Quicklite calculated footcandle (lux) levels on artificial lighting use, a control scheme was assumed, and a DRF was calculated based on annual sky conditions by climate zone.Once the DRF values are known for each orientation, the electric lighting schedule can be modified. A new profile number, representing the proportion of installed lighting switched on at that hour, replaced the daily lighting schedules when daylighting was utilized (09:00 – 17:00). To test this methodology, a sensitivity analysis was conducted between DOE 2.1A with Quicklite modifications and DOE 2.1B which has a daylighting preprocessor. The results displayed a 3.6% variation in total energy use.We conclude that daylighting calculations for design days using simplified programs can be used to approximate daylighting energy savings in building energy simulation programs that allow zoned lighting schedules but do not calculate daylight contributions.  相似文献   

15.
污染物接触量是用以衡量环境污染对人类健康影响的指标之一。调查结果显示,香港居民日常生活主要在各类室内环境,特别是居住建筑中度过,其室内空气污染对居民健康构成威胁。本文的研究首先选择了多间香港不同类型居住建筑,对其室内PM10、CO、NO2等主要室内污染物浓度进行监测,并分析了室内、外PM10浓度与居民室内各种活动等其它有关因素之间的相关关系。其次,结合香港居民日常时间安排调查的结果,计算出各种室内污染物的接触量,对居住建筑室内环境污染对居民健康的影响进行了初步评估。  相似文献   

16.
The accurate prediction of the visual comfort zone in an indoor environment is difficult as it depends on many parameters. This is especially the case for large compact urban areas in which the density and shadow from neighboring buildings can limit the accessible daylighting in indoor spaces. This paper investigates the satisfaction range for illuminance regarding indoor air temperature in office buildings and the significant parameters affecting this range in six office buildings in Tehran, Iran. Lighting comfort has been evaluated by a subjective survey (509 total responses) and field measurement. The questionnaires were filled out in 146 and 109 rooms in summer and winter, respectively. The results show that the illuminance should not be less than 550 lx, while illuminance between 600 and 650 lx provides the highest satisfaction level. The satisfaction with lighting level is affected by individual parameters such as age, type of activity, and environmental parameters such as window orientation, external obscurations, and season. A relationship was observed between lighting level satisfaction and thermal condition acceptance, and the overall comfort depends more on thermal conditions than the lighting level.  相似文献   

17.
《Energy and Buildings》2006,38(5):463-471
For typical high-rise residential building in Hong Kong, we evaluated the impact of using switchable glazing on energy use for space cooling. By using software EnergyPlus, it was found that application of switchable glazing would lead to a reduction in annual cooling electricity consumption by up to 6.6% where the actual amount depends on existence of overhangs, orientation of building wings, types and locations of rooms. Energy saving by this magnitude, however, cannot justify use of switchable glazing in residential buildings in Hong Kong, mainly because of the high glazing cost.  相似文献   

18.
《Energy and Buildings》2006,38(7):905-913
This paper describes the application of a new paradigm, called useful daylight illuminance (UDI), to assess daylight in buildings. The UDI paradigm is designed to aid the interpretation of climate-based analyses of daylight illuminance levels that are founded on hourly meteorological data for a period of a full year. Unlike the conventional daylight factor approach, a climate-based analysis employs realistic, time-varying sky and sun conditions and predicts hourly levels of absolute daylight illuminance. The conventional approach produces a single number – the daylight factor as a percentage – for each evaluation point in the space. In contrast, a climate-based analysis results in an illuminance prediction for every daylight hour of the year for each point considered. The UDI paradigm offers a way to reduce the voluminous time-series data to a form that is of comparative interpretative simplicity to the daylight factor method, but which nevertheless preserves a great deal of the significant information content of the illuminance time-series. The UDI paradigm informs not only on useful levels of daylight illuminance, but also on the propensity for excessive levels of daylight that are associated with occupant discomfort and unwanted solar gain. In a conventional analysis of daylight provision and solar penetration, the two phenomena are assessed independently using methods that are idealised (daylight factor) and qualitative (shadow patterns). The UDI paradigm offers a simple methodology whereby daylight provision and levels of solar exposure are quantified using a single evaluative schema. Thus, it is also well-suited for teaching purposes. Application of the UDI paradigm is demonstrated using an analysis of design variants for a deep-plan building with a light-well. Comparison is made with the conventional daylight factor approach, the LEED daylight credit and measures of daylight autonomy.  相似文献   

19.
A prediction model was developed to determine daylight illuminance for the office buildings by using artificial neural networks (ANNs). Illuminance data were collected for 3 months by applying a field measuring method. Utilizing weather data from the local weather station and building parameters from the architectural drawings, a three-layer ANN model of feed-forward type (with one output node) was constructed. Two variables for time (date, hour), 5 weather determinants (outdoor temperature, solar radiation, humidity, UV index and UV dose) and 6 building parameters (distance to windows, number of windows, orientation of rooms, floor identification, room dimensions and point identification) were considered as input variables. Illuminance was used as the output variable. In ANN modeling, the data were divided into two groups; the first 80 of these data sets were used for training and the remaining 20 for testing. Microsoft Excel Solver used simplex optimization method for the optimal weights. The model's performance was then measured by using the illuminance percentage error. As the prediction power of the model was almost 98%, predicted data had close matches with the measured data. The prediction results were successful within the sample measurements. The model was then subjected to sensitivity analysis to determine the relationship between the input and output variables. NeuroSolutions Software by NeuroDimensions Inc., was adopted for this application. Researchers and designers will benefit from this model in daylighting performance assessment of buildings by making predictions and comparisons and in the daylighting design process by determining illuminance.  相似文献   

20.
Using daylight as primary light source has been widely recognized as an important strategy to reduce building energy demand and enhance indoor environment quality. However, to design and operate a building to make full use of daylight, which is a dynamic light source, to meet diverse occupant needs remains a challenge. This paper reports a post-occupancy study of the visual environment in a laboratory building on a university campus, and puts a spotlight on the building occupants as it examines the effectiveness of the daylighting design and systems integration in creating a visual environment to support occupant comfort and satisfaction while reducing artificial lighting demand. Results show generally high satisfaction with daylit work environment and positive effect of the horizontal shading strategy. Issues about the integration between daylighting and electric lighting systems and level of occupant control are identified and discussed for improving the effectiveness of daylighting and enhancing the quality of the visual environment in the building of study. A multiple-tool methodology is developed and tested, which included occupant surveys, interviews, illuminance measurements, continuous data loggers, fisheye-lens camera and glare-identifying software, and documentation of spatial settings, systems features, and user behavior.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏