This companion paper focuses on an investigation of improved continuous longitudinal joint details for decked precast prestressed concrete girder bridge systems. Precast concrete girders with an integral deck, which are cast and prestressed with the girder, provide benefits of rapid construction along with improved structural performance and durability. Despite these advantages, the use of this type of construction has been limited to isolated regions of the United States. One of the issues limiting more widespread use is the perceived problem with durability of longitudinal joints used to connect adjacent girders. Four full-scale slabs connected by No. 16 (#5) headed reinforcement detail using a 152 mm (6 in.) lap length were fabricated and tested. An analytical parametric study was conducted to provide a database of maximum forces in the longitudinal joint. These maximum forces are then used to determine the loading demand necessary in the slab testing due to the service live load. Static and fatigue tests under four-point pure-flexural loading, as well as three-point flexural-shear loading, were conducted. Test results were evaluated based on flexural capacity, curvature behavior, cracking, deflection, and steel strain. Based on these test results, the improved longitudinal joint detail is a viable connection system that transfers the forces between the adjacent decked bulb tee girders.  相似文献   

2.
One of the promising systems for accelerated bridge construction is the use of the decked precast prestressed concrete girders or decked bulb-tee girders for the bridge superstructure. Using the calibrated three-dimensional finite-element models through field tests, a parametric study was conducted to determine the effect of intermediate diaphragms on the deflections and flexural strains of girders at the midspan as well as the live load forces in the longitudinal joint. The following diaphragm details were considered: different diaphragm types (steel and concrete), different diaphragm numbers between two adjacent girders, and different cross-sectional areas for steel diaphragms. Five bridge models with different diaphragm details were developed, and the short span length effect on the bridge behavior was also studied. It was found that as long as one intermediate diaphragm was provided between two adjacent girders at midspan, changing the diaphragm details did not affect the girder deflection, the girder strain, and the live load forces in the longitudinal joint significantly. The effect of diaphragms on the midspan deflection was more prominent in the short span bridge; however, the reduction in the maximum bending moment by the diaphragms was more significant in the long span bridge than in the short span bridge. Specific design recommendation is provided in this paper.  相似文献   

3.
The Val-Alain Bridge, located in the Municipality of Val-Alain on Highway 20 East, crosses over Henri River in Québec, Canada. The bridge is a slab-on-girder type with a skew angle of 20° over a single span of 49.89?m and a total width of 12.57?m. The bridge has four simply supported steel girders spaced at 3,145?mm. The deck slab is a 225-mm-thick concrete slab, with semi-integral abutments, continuous over the steel girders with an overhang of 1,570?mm on each side. The concrete deck slab and the bridge barriers were reinforced with glass fiber reinforced polymer (GFRP) reinforcing bars utilizing high-performance concrete. The Val-Alain Bridge is the Canada’s first concrete bridge deck totally reinforced with GFRP reinforcing bars. Using such nonmetallic reinforcement in combination with high-performance concrete leads to an expected service life of more than 75?years. The bridge is well instrumented with electrical resistance strain gauges and fiber-optic sensors at critical locations to record internal strain data. Also, the bridge was tested for service performance using calibrated truckloads. Design concepts, construction details, and results of the first series of live load field tests are presented.  相似文献   

4.
Static load tests were performed on support details used at the ends of prestressed concrete pedestrian bridge girders to determine the resistance characteristics of girder supports in the direction perpendicular to the longitudinal axis of the girders. The specimens tested represent support details that have also been widely used in prestressed concrete highway bridges in Minnesota and in other states. Two specimens, one representing the free-end detail and one representing the restrained-end detail were subjected to a combination of vertical and lateral loads. The applied loading was intended to simulate the loading conditions to which the girder ends would be subjected in the event of an over-height vehicle collision with the bridge. The tests revealed two types of lateral load resisting mechanisms depending on the type of support detail. The specimen with the free-end detail resisted the lateral loading through sliding friction between the components of the support assembly. Deformation of this specimen was a combination of shear deformation of the bearing pad and sliding of various support components. The restrained-end detail exhibited larger lateral load capacity than the free-end detail due to the resistance provided by the anchor rods that were intended to prevent the lateral movement of the girder ends. Failure of the specimen with restrained-end detail was due to the concrete breakout and bending of the anchor rods.  相似文献   

5.
This paper reports on a new bridge deck slab flange-to-flange connection system for precast deck bulb tee (DBT) girders. In prefabricated bridge system made of DBT girders, the concrete deck slab is cast with the prestressed girder in a controlled environment at the fabrication facility and then shipped to the bridge site. This system requires that the individual prefabricated girders be connected through their flanges to make it continuous for live load distribution. The objectives of this study are to develop an intermittent bolted connection for DBT bridge girders and to provide experimental data on the ultimate strength of the connection system. This includes identifying the crack formation and propagation, failure mode, and ultimate load carrying capacity. In this study, three different types of intermittent bolted connection were developed. Four actual-size bridge panels were fabricated and then tested to collapse. The effects of the size and the level of the fixity of the connecting steel plates, as well as the location of the wheel load were examined. The developed joint was considered successful if the experimental wheel load satisfied the requirements specified in North American bridge codes. It was concluded that location of the wheel load at the deck slab joint affected the ultimate load carrying capacity of the connections developed. Failure of the joint was observed to be due to either excessive deformation and yielding of the connecting steel plates or debonding of the embedded studs in concrete.  相似文献   

6.
In addition to their high strength and light weight, fiber-reinforced polymer (FRP) composite reinforcing bars offer corrosion resistance, making them a promising alternative to traditional steel reinforcing bars in concrete bridge decks. FRP reinforcement has been used in several bridge decks recently constructed in North America. The Morristown Bridge, which is located in Vermont, United States, is a single span steel girder bridge with integral abutments spanning 43.90 m. The deck is a 230 mm thick concrete continuous slab over girders spaced at 2.36 m. The entire concrete deck slab was reinforced with glass FRP (GFRP) bars in two identical layers at the top and the bottom. The bridge is well instrumented at critical locations for internal temperature and strain data collection with fiber-optic sensors. The bridge was tested for service performance using standard truck loads. The construction procedure and field test results under actual service conditions revealed that GFRP rebar provides very good and promising performance.  相似文献   

7.
Recently, there has been a rapid increase in using noncorrosive fiber-reinforced polymers (FRP) reinforcing bars as alternative reinforcement for bridge deck slabs, especially those in harsh environments. A new two-span girder type bridge, Cookshire-Eaton Bridge (located in the municipality of Cookshire, Quebec, Canada), was constructed with a total length of 52.08 m over two equal spans. The deck was a 200-mm-thick concrete slab continuous over four spans of 2.70 m between girders with an overhang of 1.40 m on each side. One full span of the bridge was totally reinforced using glass fiber-reinforced polymer (GFRP) bars, while the other span was reinforced with galvanized steel bars. The bridge deck was well instrumented at critical locations for internal temperature and strain data collection using fiber optic sensors. The bridge was tested for service performance using calibrated truckloads as specified by the Canadian Highway Bridge Design Code. The construction procedure and field test results under actual service conditions revealed that GFRP rebar provides very competitive performance in comparison to steel.  相似文献   

8.
Large numbers of conventionally reinforced concrete (CRC) bridges in the national bridge inventory built during the 1950s are lightly reinforced for shear. Inspections revealed many of these bridges exhibit diagonal cracks resulting in load postings, monitoring, emergency shoring, repairs, and unscheduled bridge replacements. A research program was conducted to investigate the behavior and capacity of CRC bridge girders with vintage details. Laboratory tests of large-size girders representative of 1950s design and construction practice were carried out. Various steel reinforcement configurations were tested. Loading conditions were varied to reproduce girder behavior at different positions in a bridge and various loading protocols were considered. Test results provide a comprehensive data set for comparison of analysis methods and repair strategies; and indicated that anchorage of flexural steel was key to developing higher ultimate capacity, initial crack damage may not necessarily contribute to the final failure mode, and crack width alone may not indicate the level of damage to the beam.  相似文献   

9.
Controlling the prestressing strand-stress range in precracked prestressed concrete girders is critical in the FRP strengthening process to avoid long-term fatigue failures. This paper will address the details of a design procedure that was developed to satisfy target-strengthening requirements while imposing stress range serviceability limits. Two main CFRP flexural strengthening designs were established for use in the experimental program herein. In the first, the amount of CFRP was designed to limit the average strand-stress range to 125?MPa (18?ksi), as per AASHTO requirements, under service live load while maintaining the service-ultimate moment relationship constant. The second design was intended to double the strand-stress range under service live load while keeping the same service-ultimate moment relationship. This was accomplished with iterative cycles of nonlinear sectional analysis to determine the amount of external CFRP reinforcement needed to yield both the targeted stress range and ultimate capacity. The girders were overly reinforced for shear with internal steel stirrups. However, external CFRP stirrups were used to prevent the longitudinal CFRP from premature separation and to develop full flexural capacity. The ACI 318-05 model for shear friction was used for this purpose. The paper also presents analysis results to qualify the experimental behavior of the tested girders. Load-deflection, load-strain, and moment-strand stress variations are seen to have excellent correlation with corresponding experimental curves. CFRP is shown to develop higher strains across cracks relieving strand stresses at these critical locations.  相似文献   

10.
In this study, live load distribution formulas for the girders of single-span integral abutment bridges (IABs) are developed. For this purpose, two and three dimensional finite-element models (FEMs) of several IABs are built and analyzed. In the analyses, the effects of various superstructure properties such as span length, number of design lanes, prestressed concrete girder size, and spacing as well as slab thickness are considered. The results from the analyses of two and three dimensional FEMs are then used to calculate the live load distribution factors (LLDFs) for the girders of IABs as a function of the above mentioned parameters. The LLDFs for the girders are also calculated using the AASHTO formulas developed for simply supported bridges (SSBs). The comparison of the analyses results revealed that LLDFs for girder moments and exterior girder shear of IABs are generally smaller than those calculated for SSBs using AASHTO formulas especially for short spans. However, AASHTO LLDFs for interior girder shear are found to be in good agreement with those obtained for IABs. Consequently, direct live load distribution formulas and correction factors to the current AASHTO live load distribution equations are developed to estimate the girder live load moments and exterior girder live load shear for IABs with prestressed concrete girders. It is observed that the developed formulas yield a reasonably good estimate of live load effects in prestressed concrete IAB girders.  相似文献   

11.
The lateral-torsional buckling capacity of steel bridge girders is often increased by incorporating bracing along the girder length. Permanent metal deck forms (PMDF) that are used to support the wet concrete deck during bridge construction are a likely source of stability bracing; however, their bracing performance is greatly limited by flexibility in the connections currently used with the formwork. This paper outlines results from a research study that assessed and improved the bracing potential of metal deck forms used in bridge applications. The research study included shear tests of PMDF panels, and also lateral displacement and buckling tests of twin girder systems braced with PMDF. This paper will provide key results from the shear panel tests and then focus on the lateral displacement tests. Parametric investigations of PMDF bracing behavior were conducted using finite-element analyses and the results from the lateral displacement tests served a critical role in calibrating the finite element models. This paper documents key results from lateral load tests of 17 girder–PMDF systems using a variety of bracing details and PMDF thickness values.  相似文献   

12.
Five prestressed concrete girders made with high-performance concrete were instrumented using vibrating-wire strain gages. Their behavior was monitored for three years from the time of casting. The measured change in concrete strain at the centroid of the prestressing strands was used to evaluate changes in prestress. The total measured prestress loss was as large as 28% of the total jacking stress. Due to the higher stresses, this loss is larger than would be expected for a girder made with conventional-strength concrete. The observed values of prestress losses were compared with values calculated using the recommended AASHTO LRFD and NCHRP 18-07 procedures. The AASHTO LRFD method overpredicted the average prestress losses for the highly stressed Span 2 girders by 20% while the NCHRP method underpredicted the average losses by 16%. The NCHRP method was found to be more inclusive and adaptable to regional construction. The calculated NCHRP Span 2 losses were found to be within 10% of the average measured losses when the elastic shortening losses were calculated based on measured data and differential shrinkage was calculated based on continuous beams.  相似文献   

13.
Continuity diaphragms used in prestressed girder bridges on skewed bents have caused difficulties in detailing and construction. The results of the field verification for the effectiveness of continuity diaphragms for skewed, continuous, and prestressed concrete girder bridges are presented. The current design concept and bridge parameters that were considered include skew angle and the ratio of beam spacing to span (aspect ratio). A prestressed concrete bridge with continuity diaphragms and a skewed angle of 48° was selected for full-scale test by a team of engineers from Louisiana Department of Transportation and Development and the Federal Highway Administration. The live load tests performed with a comprehensive instrumentation plan provided a fundamental understanding of the load transfer mechanism through these diaphragms. The findings indicated that the effects of the continuity diaphragms were negligible and they can be eliminated. The superstructure of the bridge could be designed with link slab. Thus, the bridge deck would provide the continuity over the support, improve the riding quality, enhance the structural redundancy, and reduce the expansion joint installation and maintenance costs.  相似文献   

14.
This paper reports on the field study of a steel stringer-fiber reinforced polymer (FRP) deck composite bridge in Pennsylvania. The objective of the study is to assess the effective compression flange width in the FRP deck and floor systems when they act compositely with underlying steel girders at service conditions. The research results reported herein support the notion of employing a design approach, for both interior and exterior girders of a composite floor system, that is philosophically consistent with current practice related to steel girders acting compositely with concrete decking. It appears from the results presented herein that FRP decks and floors acting compositely with underlying steel girders exhibit an effective width that is close to the actual girder spacing for interior beams, and approximately one-half this value for exterior beams.  相似文献   

15.
This paper presents the results of an experimental study to investigate the role of each layer of reinforcement on the behavior of concrete bridge deck slabs reinforced with fiber-reinforced polymer (FRP) bars. Four full-scale concrete deck slabs of 3,000?mm length by 2,500?mm width and 200?mm depth were constructed and tested in the laboratory. One deck slab was reinforced with top and bottom mats of glass FRP bars. Two deck slabs had only a bottom reinforcement mat with different reinforcement ratios in the longitudinal direction, while the remaining deck slab was constructed with plain concrete without any reinforcement. The deck slabs were supported on two steel girders spaced at 2,000?mm center to center and were tested to failure under a central concentrated load. The three reinforced concrete slabs had very similar behavior and failed in punching shear mode at relatively high load levels, whereas the unreinforced slab behaved differently and failed at a very low load level. The experimental punching capacities of the reinforced slabs were compared to the theoretical predictions provided by ACI 318-05, ACI 440.1R-06, and a model proposed by the writers. The tests on the four deck slabs showed that the bottom transverse reinforcement layer has the major influence on the behavior and capacity of the tested slabs. In addition, the ACI 318-05 design method slightly overestimated the punching shear strength of the tested slabs. The ACI 440.1R-06 design method yielded very conservative predictions whereas the proposed method provided reasonable yet conservative predictions.  相似文献   

16.
The general objective of this research was the construction and evaluation of a bridge using high-performance lightweight concrete (HPLWC). The resulting bridge over the Chickahominy River near Richmond, Va., consists of 15 prestressed American Association of State Highway and Transportation Officials (AASHTO) Type IV girders made of HPLWC with a density of 1,920?kg/m3 and a minimum required 28-day compressive strength of 55?MPa. The bridge also has a lightweight concrete (LWC) deck with a density of 1,850?kg/m3 and a minimum required 28-day compressive strength of 30?MPa. This research study is chiefly concerned with investigating the effects of using lightweight concrete in prestressed girders on transfer length, development length, flexural strength, girder live-load distribution factor, and dynamic load allowance. Transfer length was determined to be 432?mm, or 33?db, for several girders at the time of prestress transfer. The development length was determined to be between 1,830 and 2,440?mm, while the flexural strength ranged from 11 to 30% higher than the AASHTO flexural capacity. The measured distribution factors and dynamic load allowance were smaller than the AASHTO standard and LRFD values.  相似文献   

17.
Hybrid concrete box-girder bridges that include prestressed slabs and corrugated steel webs provide a major improvement over traditional prestressed concrete box-girder bridges. To reduce the self-weight, high strength concrete is used for the top and bottom slabs and corrugated steel webs are employed for the webs. Because the weight of the girders has been reduced, the span length can be increased for more cost-effective design. A series of systematic tests on hybrid concrete box girders subjected to torsion has been performed. According to the test results, an analytical model was developed. Using the developed analytical model, a step-by-step procedure for torsional design of such bridges is presented in this article. Based on the design procedure proposed, a girder is designed by the analytical model and checked to satisfy structural codes.  相似文献   

18.
Continuous concrete box girder bridges composed of precast reinforced and prestressed concrete beams with a U cross section and a cast-in-place top slab are frequently used for medium spans due to their competitiveness. The service behavior of such bridges is very much influenced by their segmental construction, due to time-dependent materials behavior that makes it difficult to accurately predict the stresses, strains, and deflections at long term. A 1:2 scale model of a two-span continuous bridge was tested in order to study its behavior during the construction process and under permanent loads. Time-dependent concrete properties, as well as support reactions, deflections, and strains in concrete and steel, were measured for 500 days. Important time-dependent redistributions of stresses and internal forces throughout the bridge were also measured. The test results were compared with analytical predictions obtained by means of a numerical model developed for the nonlinear and time-dependent analysis of segmentally erected, reinforced and prestressed concrete structures. Generally good agreement was obtained, showing the adequacy of the model to reproduce the structural effects of complex interactive time-dependent phenomena.  相似文献   

19.
This paper describes the behavior of hybrid girders consisting of fiber-reinforced polymer (FRP) bridge decks adhesively connected to steel main girders. Two large-scale girders were experimentally investigated at the serviceability and ultimate limit state as well as at failure. One of the girders was additionally fatigue loaded to 10 million cycles. Compared to the behavior of a reference steel girder, deflections of the two girders at the SLS were decreased by 30% and failure loads increased by 56% due to full composite action in the adhesive layer. A ductile failure mode occurred: Deck compression failure during yielding of the steel girder. The adhesive connections were able to prevent buckling of the yielding top steel flanges. Thus, compared to the reference steel girder, the maximum deflections at failure could be increased up to 130%. No deterioration due to fatigue loading was observed. Based on the experimental results, a conceptual design method for bonded FRP/steel girders was developed. The proposed method is based on the well-established design method for hybrid girders with concrete decks and shear stud connections. The necessary modifications are proposed.  相似文献   

20.
The design, technology, and construction of a small road bridge made of very high performance fiber-reinforced concrete is described in this paper. The bridge consists of precast prestressed concrete beams with a cast-in-place ordinary concrete deck. A preliminary experimental investigation was conducted to define the mix design, to establish the properties of the material and its durability, and to study the flexural behavior of the prestressed concrete beams with and without the concrete deck. The effect of steel fibers at the structural level, where there is an influence of constitutive behavior and size effects, was analyzed by testing a prestressed beam using very high performance fiber-reinforced concrete without fibers. The establishment of the structural properties of the material then allowed the design of the final section of the bridge beams and the definition of a model to justify the design rules adopted. This project represents an attempt to demonstrate the industrial feasibility of very high performance concrete structural elements manufactured with conventional raw materials and usual production techniques and to evaluate the production technology when utilizing steel fibers.  相似文献   