首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper presents the experimental results of the first phase of a study undertaken at the American University of Beirut to examine the effectiveness of fiber reinforced polymer (FRP) wraps to confine steel reinforcement in a tension lap splice region anchored in high-strength reinforced-concrete beams. Seven beam specimens were constructed. The specimens were reinforced on the tension side with three deformed bars spliced at midspan. The splice region was devoid of any transverse reinforcement to allow a full examination of the FRP wrap contribution. Glass fiber reinforced polymer (GFRP) sheets were used. The main test variables were the GFRP configuration in the splice region (one strip, two strips, or a continuous strip), and the number of layers of the GFRP wraps placed around the splice region (one layer or two layers). All GFRP wraps were U-shaped. Except for the epoxy adhesive, no other anchorage mechanism or bonding procedure was applied for the GFRP wraps on the concrete beam. Following the application of the GFRP wraps, the beams were tested in positive bending. The test results demonstrated that GFRP wraps were effective in enhancing the bond strength and ductility of failure mode of the tension lap splices, especially when continuous strips were applied over the splice region.  相似文献   

2.
The bond behavior of reinforcing bars in concrete is a critical issue in the design of reinforced concrete structures. This study focuses on the bond strength of fiber reinforced polymer (FRP) rebars in normal strength concrete. Four different types of rebars were tested using the pullout method: aramid FRP (AFRP); carbon FRP (CFRP); glass FRP (GFRP), and steel. This involved a total of 151 specimens containing 6, 8, 10, 16, and 19?mm rebars embedded in a 203?mm concrete cube. The test embedment lengths were five, seven, and nine times the rebar diameter (db). For each rebar, the test results include the bond stress–slip response and the mode of failure. The test results showed that the bond strength of an FRP rebar is, on average, 40–100% the bond strength on a steel rebar for pullout failure mode. Based on this research, a proposal for the average bond strength of straight FRP rebars in normal strength concrete is made, which verifies an existing bond strength relationship (GFRP) and extends its application to AFRP and CFRP. It is an expression that is a function of the rebar diameter, and the concrete compressive strength.  相似文献   

3.
The results of testing two simply and three continuously supported concrete beams reinforced with glass fiber-reinforced polymer (GFRP) bars are presented. The amount of GFRP reinforcement was the main parameter investigated. Over and under GFRP reinforcements were applied for the simply supported concrete beams. Three different GFRP reinforcement combinations of over and under reinforcement ratios were used for the top and bottom layers of the continuous concrete beams tested. A concrete continuous beam reinforced with steel bars was also tested for comparison purposes. The experimental results revealed that over-reinforcing the bottom layer of either the simply or continuously supported GFRP beams is a key factor in controlling the width and propagation of cracks, enhancing the load capacity, and reducing the deflection of such beams. Comparisons between experimental results and those obtained from simplified methods proposed by the ACI 440 Committee show that ACI 440.1R-06 equations can reasonably predict the load capacity and deflection of the simply and continuously supported GFRP reinforced concrete beams tested.  相似文献   

4.
Realistic Bond Strength of FRP Rebars in NSC from Beam Specimens   总被引:2,自引:0,他引:2  
The bond strength of reinforcing bars in concrete is a prerequisite for the evaluation of the development length in reinforced concrete structures. This study concerns these phenomena for fiber reinforced polymer (FRP) rebars in normal strength concrete (NSC). Three different types of rebars were tested using the beam specimen: Carbon, glass, and steel. This involved a total of 26 beam specimens containing 10, 16, and 19?mm rebars. The test embedment lengths were 10, 15, and 20 times the rebar diameter (db). For each rebar tested, the results concern load deflection curves, bond stress-slip responses, and the mode of failure. The results showed that the bond strength of a FRP rebar is, generally, lower than that of steel rebar. Based on this and previous research, proposals for the average bond strength and for the development length of straight FRP rebars under tension in NSC are made.  相似文献   

5.
The local bond mechanics of glass-fiber reinforced polymer (GFRP) bars in normal strength concrete was investigated through experimental testing and analytical modeling. The experimental program was comprised of 30 direct tension pullout specimens with short anchorages. A novel test setup, specially designed so as to minimize the spurious influence of testing conditions on measured bond properties was adopted in the study. Parameters considered were the bar roughness and diameter, the size effect expressed by the constant cover to bar diameter ratio, and the external confining pressure exerted over the anchorage length by transverse externally bonded FRP sheets. Results of the study were summarized in the form of local bond-slip curves, whereby performance limit states were quantified by the amount of loaded end slip and bond strength. An analytical model of the bond stress-slip response of a GFRP bar was derived from first principles and calibrated against the test data of the present investigation. Using the calibrated model, design values for bond and slip were estimated with reference to the code limit state model for bond.  相似文献   

6.
This paper examines the behavior of Eurocrete fiber-reinforced polymer (FRP) bars (glass, carbon, aramid, and hybrid) in concrete under direct pullout conditions. More than 130 cube specimens were tested in direct pullout where no splitting was allowed to develop. In normal concrete, the mode of bond failure of FRP bars was found to differ substantially from that of deformed steel bars because of damage to the resin rich surface of the bar when pullout takes place. Bond strengths developed by carbon fiber-reinforced polymer and glass fiber-reinforced polymer bars appear to be very similar and just below what is expected from deformed steel bars under similar experimental conditions. The load slip curves highlight some of the fundamental differences between steel and FRP materials. This paper reports in detail on the influence of various parameters that affect bond strength and development such as the embedment length, type, shape, surface characteristics, and diameter of the bar as well as concrete strength. The testing arrangement is also shown to influence bond strength because of the “wedging effect” of the bars.  相似文献   

7.
For decades, bridge slabs have been troubled by the corrosion of steel reinforcement. The unique corrosion resistance of glass fiber-reinforced polymer (GFRP) bars makes them a promising alternative to steel bars. Experiments have been conducted to investigate the bond performance of GFRP reinforced concrete under constant amplitude cyclic fatigue loading. Each specimen was an identical length beam with a single GFRP bar at the bottom, intended to simulate a transverse strip of a typical bridge deck slab. The crack growth was monitored for specimens of different widths, simulating different transverse reinforcement spacings. Up to 2?million?cycles of cyclic loads were applied at 100% typical service load levels. No fatigue failure was encountered in the testing. The effects of moderate overloads were also investigated.  相似文献   

8.
This paper presents an experimental study on the bond behavior of longitudinal reinforcements in the hanging region (i.e., the part of the beam outside the support) of a simply supported reinforced concrete beam. Twenty-three reinforced concrete beams were tested to failure. Carbon fiber-reinforced polymer (CFRP) bars were used as longitudinal reinforcements in place of ordinary steel bars. The main test variables were (1) stirrup ratio in the hanging region; (2) stirrup ratio in the shear span; and (3) bond length in the hanging region. The test results showed that, even though the beam had a sufficient stirrup ratio in the shear span, bond-splitting failure occurred in the shear span of the beam with insufficient bond length in the hanging region. Based on the test results, the provision of ACI and AIJ codes on the additional anchorage length in the hanging region was evaluated, and a model for predicting tension force at the support was presented.  相似文献   

9.
In the last decade, noncorrodible fiber-reinforced polymer (FRP) reinforcing bars have been increasingly used as the main reinforcement for concrete structures in harsh environments. Also, owing to their lower cost compared with other types of FRP bars, glass-FRP (GFRP) bars are more attractive to the construction industry, especially for implementation in bridge deck slabs. In North America, bridge deck slabs are exposed to severe environmental conditions, such as freeze-thaw action, in addition to traffic fatigue loads. Although the bond strength of GFRP bars has been proved to be satisfactory, their durability performance under the dual effects of fatigue-type loading and freeze-thaw action is still not well understood. Few experimental test data are available on the bond characteristics of FRP bars in concrete elements under different loading and environmental conditions. This research investigates the individual and combined effects of freeze-thaw cycles along with sustained axial load and fatigue loading on the bond characteristics of GFRP bars embedded in concrete. An FRP-reinforced concrete specimen was developed to apply axial-tension fatigue or sustained loads to GFRP bars within a concrete environment. A total of thirty-six test specimens was constructed and tested. The test parameters included bar diameter, concrete cover thickness, loading scheme, and environmental conditioning. After conditioning, each specimen was sectioned into two halves for pullout testing. Test results showed that fatigue load cycles resulted in approximately 50% loss in the bond strength of sand-coated GFRP bars to concrete, while freeze-thaw cycles enhanced their bond to concrete by approximately 40%. Larger concrete covers were found more important in cases of larger bar sizes simultaneously subjected to fatigue load and freeze-thaw cycles.  相似文献   

10.
This paper reports on the fourth phase of a multiphase study undertaken at the American University of Beirut (AUB) to examine the effect of fiber-reinforced polymer (FRP) sheets in confining bond-critical regions in reinforced concrete beams. Results of the first three phases showed that glass- and carbon-fiber-reinforced polymer (GFRP and CFRP) sheets were effective in increasing the bond strength and improving the ductility of the mode of failure of tension lap splices in high-strength concrete (HSC) and normal-strength concrete (NSC) beams. The main objective of the fourth phase of the AUB study was to assess the effect of CFRP sheets in improving the serviceability and ultimate response of beam anchorage specimens. The added experimental data and the improved knowledge of the bond behavior of FRP confined concrete members will encourage the use of FRP technology to strengthen and retrofit bond anchorage zones. Ten beam anchorage specimens were tested in positive bending in two series. The variables were bar size, anchorage length, and concrete strength. For each bar size, anchorage length, and concrete strength, two companion specimens—identical except for whether the anchorage zone was wrapped with FRP sheets or not wrapped—were tested. The test results demonstrated that CFRP sheets were effective in enhancing the bond strength and ductility of anchorage zones in beam anchorage specimens where splitting failures were imminent.  相似文献   

11.
Reinforcing concrete with a combination of steel and glass fiber-reinforced polymer (GFRP) bars promises favorable strength, serviceability, and durability. To verify its promise and to support design of concrete structures with this hybrid type of reinforcement, we have experimentally and theoretically investigated the load-deflection behavior of concrete beams reinforced with hybrid GFRP and steel bars. Eight beams, including two control beams reinforced with only steel or only GFRP bars, were tested. The amount of reinforcement and the ratio of GFRP to steel were the main parameters investigated. Hybrid GFRP/steel-reinforced concrete beams with normal effective reinforcement ratios exhibited good ductility, serviceability, and load carrying capacity. Comparisons between the experimental results and the predictions from theoretical analysis showed that the models we adopted could adequately predict the load carrying capacity, deflection, and crack width of hybrid GFRP/steel-reinforced concrete beams.  相似文献   

12.
This paper reports on the third phase of a multiphase study undertaken at the American University of Beirut (AUB) to examine the effect of fiber-reinforced polymer (FRP) sheets in confining tension lap splice regions in reinforced concrete beams. Results of the first two phases showed that glass and carbon fiber-reinforced polymer (GFRP and CFRP) sheets were effective in increasing the bond strength and improving the ductility of the mode of failure of tension lap splices in high-strength concrete (HSC) beams with nominal concrete strength of 70 MPa. The experimental results of the two phases were used to propose a new FRP confinement parameter, Ktr,f, that accounts for the bond strength contribution of FRP sheets wrapping tension lap splice regions in HSC beams. In this third phase of the AUB study, the trend of the results of phases 1 and 2 and the validity of the analytical model proposed were verified if normal-strength concrete (NSC) is used instead of HSC. Seven beams with nominal concrete strength of 27.58 MPa (4 ksi) were tested in positive bending. Each beam was designed with a tension lap splice in a constant moment region in the midspan of the beam. The main test variables were the configuration (1 strip, 2 strips, or a continuous strip) and the number of layers (1 layer or 2 layers) of the CFRP sheets wrapping the splice region. The test results demonstrated that CFRP sheets were effective in enhancing the bond strength and ductility of failure mode of tension lap splices in NSC in a very similar way to HSC. In addition, the FRP confinement index proposed earlier for HSC was proven to be valid in the case of NSC.  相似文献   

13.
This paper evaluates the shear strength, Vc, of intermediate length (2.5 < a∕d < 6) simply supported concrete beams subjected to four-point monotonic loading and reinforced with deformed, glass fiber-reinforced polymer (GFRP) reinforcement bars. Six different overreinforced GFRP designs, ρ > ρb, were tested with three replicate beams per design. All samples failed as a result of diagonal-tension shear. Measured shear strengths at failure are compared with theoretical predictions calculated according to traditional steel-reinforced concrete procedures and recently published expressions intended for beams reinforced with GFRP. Recommendations are made regarding the adequacy of shear strength prediction equations for GFRP-reinforced members. The study concludes that shear capacity is significantly overestimated by the “Building Code Requirements for Structural Concrete and Commentary” (ACI 318-99) expression for, Vc, as a result of the large crack widths, small compression block, and reduced dowel action in GFRP-reinforced flexural members. Shear strength was found to be independent of the amount of longitudinal GFRP reinforcement. A simplified empirical equation for predicting the ultimate shear strength of concrete beams reinforced with GFRP is endorsed.  相似文献   

14.
In the case of heavily reinforced concrete structural members, bundled bars are required rather than spaced bars. The use of spliced bundled bars is necessary when available bar lengths are limited. No design recommendations regarding the use of bundled or spliced bundled FRP bars are available. The results of four-point flexural testing of nine concrete beams reinforced with spliced bundled CFRP bars are presented herein. The effects of the type of bundle and splice length on the bond strength of bundled CFRP bars are investigated. Based on the experimental results, a procedure for determining the critical splice length of FRP bars is presented and the corresponding values of bond stresses can be predicted. Moreover, the ultimate strength analysis method is used to predict the maximum stress in spliced bundled CFRP bars. Finally, comparisons with the existing recommendations regarding the use of bundled steel bars and the recommended modifications for bundled CFRP bars are presented.  相似文献   

15.
Continuous concrete beams are structural elements commonly used in structures that might be exposed to extreme weather conditions and the application of deicing salts, such as bridge overpasses and parking garages. In such structures, reinforcing continuous concrete beams with the noncorrodible fiber-reinforced polymer (FRP) bars is beneficial to avoid steel corrosion. However, the linear-elastic behavior of FRP materials makes the ability of continuous beams to redistribute loads and moments questionable. A total of seven full-scale continuous concrete beams were tested to failure. Six beams were reinforced with glass fiber-reinforced polymer (GFRP) longitudinal bars, whereas one was reinforced with steel as control. The specimens have rectangular cross section of 200×300??mm and are continuous over two spans of 2,800?mm each. Both steel and GFRP stirrups were used as transverse reinforcement. The material, spacing, and amount of transverse reinforcement were the primary investigated parameters in this study. In addition, the experimental results were compared with the code equations to calculate the ultimate capacity. The experimental results showed that moment redistribution in FRP-reinforced continuous concrete beams is possible and is improved by increasing the amount of transverse reinforcement. Also, beams reinforced with GFRP stirrups illustrated similar performance compared with their steel-reinforced counterparts.  相似文献   

16.
Glass fiber–reinforced polymer (GFRP) materials provide practical solutions to corrosion and site-maneuvering problems for civil infrastructures using conventional steel bars as reinforcements. In this study, the feasibility of using GFRP soil nails for slope stabilization is evaluated. The GFRP soil nail system consists of a GFRP pipe installed by the double-grouting technique. Two field-scale pullout tests were performed at a slope site. Fiber Bragg grating (FBG) sensors, strain gauges, linear variable displacement transformers (LVDTs), and a load cell were used to measure axial strain distributions and pullout force-displacement relationships during testing. The pullout test results of steel soil nails at another slope site are also presented for comparison. It is proven that the load transfer mechanisms of GFRP and steel soil nails have certain difference. Based on these test results, a simplified model using a hyperbolic shear stress-strain relationship was developed to describe the pullout performance of the GFRP soil nail. A parametric study was conducted using this model to study some factors affecting the pullout behavior of GFRP soil nails, including nail diameter, shear resistance of soil-grout interface, and ratio of interface shear coefficient to the Young’s modulus of the nail. The results indicate that the GFRP soil nail may exhibit excessive pullout displacement and thus a lower allowable pullout resistance than with the steel soil nail.  相似文献   

17.
The behavior of six 1:2.5-scale reinforced concrete cantilever wall specimens having an aspect ratio of 1.5, tested to failure and subsequently repaired and strengthened using fiber-reinforced polymer (FRP) sheets is investigated. Specimens were first repaired by removing heavily cracked concrete, lap splicing the fractured steel bars by welding new short bars, placing new hoops and horizontal web reinforcement, and finally casting nonshrink high-strength repair mortar. The specimens were then strengthened using FRP sheets and strips, with a view to increasing flexural as well as shear strength and ductility. In addition to different arrangements of steel and FRP reinforcement in the walls, a key parameter was the way carbon-FRP strips added for flexural strengthening were anchored; steel plates and steel angles were used to this effect. Steel plates were anchored using U-shaped glass-FRP (GFRP) strips or bonded metal anchors. Test results have shown that by using FRP reinforcement, the flexural and shear strength of the specimens can be increased. From the anchorage systems tested, metal plates combined with FRP strips appear to be quite efficient. The effectiveness of the bonded metal anchors used was generally less than that of the combination of plates and GFRP strips. In all cases, final failure of the FRP anchorage is brittle, but only occurs after the peak strength is attained and typically follows the fracture of steel reinforcement in critical areas, hence the overall behavior of the strengthened walls is moderately ductile.  相似文献   

18.
Continuous concrete beams are commonly used elements in structures such as parking garages and overpasses, which might be exposed to extreme weather conditions and the application of deicing salts. The use of the fiber-reinforced polymers (FRP) bars having no expansive corrosion product in these types of structures has become a viable alternative to steel bars to overcome the steel-corrosion problems. However, the ability of FRP materials to redistribute loads and moments in continuous beams is questionable due to the linear-elastic behavior of such materials up to failure. This paper presents the experimental results of four reinforced concrete beams with rectangular cross section of 200×300?mm continuous over two spans of 2,800 mm each. The material and the amount of longitudinal reinforcement were the main investigated parameters in this study. Two beams were reinforced with glass FRP (GFRP) bars in to different configurations while one beam was reinforced with carbon FRP bars. A steel-reinforced continuous concrete beam was also tested to compare the results. The experimental results showed that moment redistribution in FRP-reinforced continuous concrete beams is possible if the reinforcement configuration is chosen properly. Increasing the GFRP reinforcement at the midspan section compared to middle support section had positive effects on reducing midspan deflections and improving load capacity. The test results were compared to the available design models and FRP codes. It was concluded that the Canadian Standards Association Code (CSA/S806-02) could reasonably predict the failure load of the tested beams; however, it fails to predict the failure location.  相似文献   

19.
The behaviors of simply and continuously supported beams reinforced with fiber reinforced polymer (FRP) materials are presented in this paper. The experimental testing program included seven simple rectangular beams and seven continuous T-section beams. Reinforcing bars and stirrups were made of steel, carbon, or glass fiber reinforced polymer (GFRP). It was concluded that the use of GFRP stirrups increased the shear deformation, and as a result deflection increased. Also, GFRP stirrups changed the failure mode from flexural to shear or flexural-shear, depending on the type of reinforcement bars (FRP or steel). Furthermore, the use of FRP reinforcement in continuous beams increased deformation. This increase remained small and acceptable at the service load level, but significantly increased near failure. While different FRP reinforcement arrangements were found to have the same load capacity as steel reinforcements in conventional beams, failure modes and ductility differed. Failure mode was governed by both the type of reinforcing bars and the type of stirrups. Additionally, the dowel effect influences the load carrying capacity of FRP reinforced continuous beams. A method for evaluating the ductility is presented. The ratio of absorbed energy at failure to the total energy, “energy ratio,” was used as a measure of ductility. Based on this definition, a classification of ductile, semiductile, and brittle behavior is suggested. The theoretical results obtained using the suggested method were substantiated experimentally. The continuous beams experienced higher “energy ratios” than did simple beams.  相似文献   

20.
The flexural performance of reinforced concrete-filled glass-fiber reinforced polymer (GFRP) tubes (CFFTs) has been investigated using seven specimens, 220?mm in diameter and 2.43?m long. Specimens were reinforced with either steel, GFRP, or carbon–fiber reinforced polymer (FRP) rebar of various sizes. Prefabricated GFRP tubes with most of the fibers oriented in the hoop direction were used in five specimens. One control specimen included conventional steel spirals of stiffness comparable to the GFRP tube and the other had no transverse reinforcement. Test results have shown that CFFT beams performed substantially better than beams with a steel spiral. Unlike CFFTs with FRP rebar, CFFTs with steel rebar failed in a sequential progressive manner, leading to considerable ductility. An analytical model capable of predicting the full response of reinforced CFFT beams, including the sequential progressive failure, has been developed, verified, and used in a parametric study. It is shown that laminate structure of the tube affects the behavior, only after yielding of the steel rebar. Steel reinforcement ratio significantly affects stiffness and strength, whereas concrete strength has an insignificant effect on the overall performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号