首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Since bridge deck slabs directly sustain repeated moving wheel loads, they are one of the most bridge elements susceptible to fatigue failure. Recently, glass fiber-reinforced polymer (FRP) composites have been widely used as internal reinforcement for concrete bridge deck slabs as they are less expensive compared to the other kinds of FRPs (carbon and aramid). However, there is still a lack of information on the performance of FRP–reinforced concrete elements subjected to cyclic fatigue loading. This research is designed to investigate the fatigue behavior and fatigue life of concrete bridge deck slabs reinforced with glass FRP bars. A total of five full-scale deck slabs were constructed and tested under concentrated cyclic loading until failure. Different reinforcement types (steel and glass FRP), ratios, and configurations were used. Different schemes of cyclic loading (accelerated variable amplitude fatigue loading) were applied. Results are presented in terms of deflections, strains in concrete and FRP bars, and crack widths at different levels of cyclic loading. The results showed the superior fatigue performance and longer fatigue life of concrete bridge deck slabs reinforced with glass FRP composite bars.  相似文献   

2.
Fiber-reinforced polymer (FRP) composite bridge deck panels are high-strength, corrosion resistant, weather resistant, etc., making them attractive for use in new construction or retrofit of existing bridges. This study evaluated the force-deformation responses of FRP composite bridge deck panels under AASHTO MS 22.5 (HS25) truck wheel load and up to failure. Tests were conducted on 16 FRP composite deck panels and four reinforced concrete conventional deck panels. The test results of FRP composite deck panels were compared with the flexural, shear, and deflection performance criteria per Ohio Department of Transportation specifications, and with the test results of reinforced concrete deck panels. The flexural and shear rigidities of FRP composite deck panels were calculated. The response of all panels under service load, factored load, cyclic loading, and the mode of failure were reported. The tested bridge deck panels satisfied the performance criteria. The safety factor against failure varies from 3 to 8.  相似文献   

3.
We examine here the replacement of a deteriorated concrete deck in the historic Hawthorne Street Bridge in Covington, Va. with a lightweight fiber-reinforced polymer (FRP) deck system (adhesively bonded pultruded tube and plate assembly) to increase the load rating of the bridge. To explore construction feasibility, serviceability, and durability of the proposed deck system, a two-bay section (9.45 by 6.7?m) of the bridge has been constructed and tested under different probable loading scenarios. Experimental results show that the response of the deck is linear elastic with no evidence of deterioration at service load level (HS-20). From global behavior of the bridge superstructure (experimental data and finite- element analysis), degree of composite action, and load distribution factors are determined. The lowest failure load (93.6?kips or 418.1?kN) is about 4.5 times the design load (21.3?kips or 94?kN), including dynamic allowance at HS-20. The failure mode is consistent in all loading conditions and observed to be localized under the loading patch at the top plate and top flange of the tube. In addition to global performance, local deformation behavior is also investigated using finite-element simulation. Local analysis suggests that local effects are significant and should be incorporated in design criteria. Based on parametric studies on geometric (thickness of deck components) and material variables (the degree of orthotropy in pultruded tube), a proposed framework for the sizing and material selection of cellular FRP decks is presented for future development of design guidelines for composite deck structures.  相似文献   

4.
Innovative fiber-reinforced polymer (FRP) composite highway bridge deck systems are gradually gaining acceptance in replacing damaged/deteriorated concrete and timber decks. FRP bridge decks can be designed to meet the American Association of State Highway and Transportation Officials (AASHTO) HS-25 load requirements. Because a rather complex sub- and superstructure system is used to support the FRP deck, it is important to include the entire system in analyzing the deck behavior and performance. In this paper, we will present a finite-element analysis (FEA) that is able to consider the structural complexity of the entire bridge system and the material complexity of an FRP sandwich deck. The FEA is constructed using a two-step analysis approach. The first step is to analyze the global behavior of the entire bridge under the AASHTO HS-25 loading. The next step is to analyze the local behavior of the FRP deck with appropriate load and boundary conditions determined from the first step. For the latter, a layered FEA module is proposed to compute the internal stresses and deformations of the FRP sandwich deck. This approach produces predictions that are in good agreement with experimental measurements.  相似文献   

5.
In the last decade, noncorrodible fiber-reinforced polymer (FRP) reinforcing bars have been increasingly used as the main reinforcement for concrete structures in harsh environments. Also, owing to their lower cost compared with other types of FRP bars, glass-FRP (GFRP) bars are more attractive to the construction industry, especially for implementation in bridge deck slabs. In North America, bridge deck slabs are exposed to severe environmental conditions, such as freeze-thaw action, in addition to traffic fatigue loads. Although the bond strength of GFRP bars has been proved to be satisfactory, their durability performance under the dual effects of fatigue-type loading and freeze-thaw action is still not well understood. Few experimental test data are available on the bond characteristics of FRP bars in concrete elements under different loading and environmental conditions. This research investigates the individual and combined effects of freeze-thaw cycles along with sustained axial load and fatigue loading on the bond characteristics of GFRP bars embedded in concrete. An FRP-reinforced concrete specimen was developed to apply axial-tension fatigue or sustained loads to GFRP bars within a concrete environment. A total of thirty-six test specimens was constructed and tested. The test parameters included bar diameter, concrete cover thickness, loading scheme, and environmental conditioning. After conditioning, each specimen was sectioned into two halves for pullout testing. Test results showed that fatigue load cycles resulted in approximately 50% loss in the bond strength of sand-coated GFRP bars to concrete, while freeze-thaw cycles enhanced their bond to concrete by approximately 40%. Larger concrete covers were found more important in cases of larger bar sizes simultaneously subjected to fatigue load and freeze-thaw cycles.  相似文献   

6.
An experimental investigation was performed to assess the performance of a hybrid fiber-reinforced polymer/reinforced concrete bridge system. The full-scale laboratory specimen was representative of an 813?mm (32?in.) wide strip of a completed bridge in San Patricio County, Tex. The specimen was first subjected to static loading prior to casting the reinforced concrete deck. Displacement, strain, and acoustic emission were recorded. After completion of the nondestructive static loading a reinforced concrete deck was cast in the laboratory to represent one unit of the completed bridge. Load was statically applied with several increased load cycles until failure occurred at a load level exceeding 18 times the calculated design load. The results of the static testing indicated that the original design of the hybrid bridge was very conservative. An optimized design of the hybrid bridge was then derived. The static load testing program and the resulting optimized design are described.  相似文献   

7.
A fiber-reinforced polymer (FRP) composite cellular deck system was used to rehabilitate a historical cast iron thru-truss structure (Hawthorne St. Bridge in Covington, Va.). The most important characteristic of this application is reduction in self-weight, which raises the live load-carrying capacity of the bridge by replacing the existing concrete deck with a FRP deck. This bridge is designed to HL-93 load and has a 22.86?m clear span with a roadway width of 6.71?m. The panel-to-panel connections were accomplished using full width, adhesively (structural urethane adhesive) bonded tongue and groove splices with scarfed edges. To ensure proper construction, serviceability, and strength of the splice, a full-scale two-bay section of the bridge with three adhesively bonded panel-to-panel connections was constructed and tested in the Structures Laboratory at Virginia Tech. Test results showed that no crack initiated in the joints under service load and no significant change in stiffness or strength of the joint occurred after 3,000,000 cycles of fatigue loading. The proposed adhesive bonding technique was installed in the bridge in August 2006.  相似文献   

8.
This paper presents results of an evaluation of the fatigue performance of a novel steel-free fiber-reinforced polymer (FRP)–concrete modular bridge deck system consisting of wet layup FRP–concrete deck panels which serve as both formwork and flexural reinforcement for the steel-free concrete slab cast on top. A two-span continuous deck specimen was subjected to a total of 2.36 million cycles of load simulating an AASHTO HS20 design truck with impact at low and high magnitudes. Quasistatic load tests were conducted both before initiation of fatigue cycling and after predetermined numbers of cycles to evaluate the system response. No significant stiffness degradation was observed during the first 2 million cycles of fatigue service load. A level of degradation was observed during subsequent testing at higher magnitudes of fatigue load. A fairly elastic and stable response was obtained from the system under fatigue service load with little residual displacement. The system satisfied both strength and serviceability limit states with respect to the code requirements for crack width and deflection.  相似文献   

9.
This paper addresses the laboratory and field performance of multicellular fiber-reinforced polymer (FRP) composite bridge deck systems produced from adhesively bonded pultrusions. Two methods of deck contact loading were examined: a steel patch dimensioned according to the AASHTO Bridge Design Specifications, and a simulated tire patch constructed from an actual truck tire reinforced with silicon rubber. Under these conditions, deck stiffness, strength, and failure characteristics of the cellular FRP decks were examined. The simulated tire loading was shown to develop greater global deflections given the same static load. The failure mode is localized and dominated by transverse bending failure of the composites under the simulated tire loading as opposed to punching shear for the AASHTO recommended patch load. A field testing facility was designed and constructed in which FRP decks were installed, tested, and monitored to study the decks’ in-service field performance. No significant loss of deck capacity was observed after more than one year of field service. However, it was shown that unsupported edges (or free edges) are undesirable due to transitional stiffness from approach to the unsupported deck edge.  相似文献   

10.
This paper presents the experimental results from static and fatigue testing on a scale model of a hybrid fiber-reinforced polymer (FRP)–concrete bridge superstructure. The hybrid superstructure was designed as a simply-supported single span bridge with a span of 18.3 m. Three trapezoidal glass fiber-reinforced polymer (GFRP) box sections are bonded together to make up a one-lane superstructure, and a layer of concrete is placed in the compression side of those sections. This new design was proposed in order to reduce the initial costs and to increase the stiffness of GFRP composite structures. Static test results showed that the bridge model meets the stiffness requirement and has significant reserve strength. The bridge model was also subjected to two million load cycles to investigate its fatigue characteristics. The fatigue testing revealed that the structural system exhibits insignificant stiffness degradation.  相似文献   

11.
Fiber-reinforced polymers (FRP) are becoming more widely used for repair and strengthening of conventionally reinforced concrete (RC) bridge members. Once repaired, the member may be exposed to millions of load cycles during its service life. The anticipated life of FRP repairs for shear strengthening of bridge members under repeated service loads is uncertain. Field and laboratory tests of FRP-repaired RC deck girders were performed to evaluate high-cycle fatigue behavior. An in-service 1950s vintage RC deck-girder bridge repaired with externally bonded carbon fiber laminates for shear strengthening was inspected and instrumented, and FRP strain data were collected under ambient traffic conditions. In addition, three full-size girder specimens repaired with bonded carbon fiber laminate for shear strengthening were tested in the laboratory under repeated loads and compared with two unfatigued specimens. Results indicated relatively small in situ FRP strains, laboratory fatigue loading produced localized debonding along the FRP termination locations at the stem-deck interface, and the fatigue loading did not significantly alter the ultimate shear capacity of the specimens.  相似文献   

12.
Fiber-reinforced polymer (FRP) composites are increasingly being used in bridge deck applications. However, there are currently only fledgling standards to design and characterize FRP deck systems. One area that should be addressed is the loading method for the FRP deck. It has been observed that the type of loading patch greatly influences the failure mode of a cellular FRP deck. The contact pressure distribution of a real truck loading is nonuniform with more concentration near the center of the contact area as a result of the conformable contact mechanics. Conversely, the conventional rectangular steel patch on a FRP deck act like a rigid flat punch and produces stress concentration near the edges. A proposed simulated tire patch has been examined for loading a cellular FRP deck with the load distribution characterized by a pressure sensitive film sensor and three-dimensional contact analysis using ANSYS. A loading profile is proposed as a design tool for analyzing FRP deck systems for strength and durability. Local top surface strains and displacements of the cellular FRP deck are found to be higher with proposed loading profile compared to those for the conventional uniformly distributed loading. Parametric studies on the deck geometry show that the global displacement criterion used for characterizing bridge deck is inadequate for a cellular FRP deck and that the local effects must be considered.  相似文献   

13.
The use of glass fiber-reinforced polymer (GFRP) bridge decks is appealing for applications where minimizing dead load is critical. This paper describes fatigue and strength testing of two types of GFRP decks being considered for use in the retrofit of an aging steel arch bridge in Snohomish County, Washington, where a roadway expansion is necessary and it is desirable to minimize the improvements to the arch superstructure. Each test used a setup designed to be as close as practicable to what will be the in situ conditions for the deck, which included a 2% cross slope for drainage. The fatigue testing consisted of a single 116 kN (26 kip) load applied for 2 million cycles, which corresponds to an AASHTO HS-25 truck with a 30% impact factor, and the strength testing consisted of multiple runs of a monotonically applied minimum load of 347 kN (78 kips). Results from the fatigue testing indicated a degradation of the stiffness of both deck types; however, the degradation was limited to less than 12% over the duration of loading. Further, the results showed both deck types accumulated permanent deck displacement during fatigue loading and one deck type used a detail with poor fatigue performance. That detail detrimentally impacted the overall deck performance and caused large permanent deck deformations. It was also found that degradation of composite behavior between the deck and girders occurs during fatigue loading and should be included in design.  相似文献   

14.
A hybrid concept of composite sandwich panel with hybrid fiber-reinforced polymer (FRP)—steel core was proposed for bridge decks in order to not only improve stiffness and buckling response but also be cost efficient compared to all glass fiber-reinforced polymer (GFRP) decks. The composite sandwich bridge deck system is comprised of wrapped hybrid core of GFRP grid and multiple steel box cells with upper and lower GFRP facings. Its structural performance under static loading was evaluated and compared with the ANSYS finite element predictions. It was found that the presented composite sandwich panel with hybrid FRP-steel core was very efficient for use in bridges. The thickness of the hybrid deck may be decreased by 19% when compared with the all GFRP deck. The failure mode of the proposed hybrid deck was more favorable because of the yielding of the steel tube when compared with that of all GFRP decks.  相似文献   

15.
This study examines the effects of one-dimensional fiber-reinforced polymer (FRP) composite rehabilitation systems on the flexural fatigue performance of reinforced concrete bridge girders. Eight 508?mm deep and 5.6?m long reinforced concrete T-beams, with and without bonded FRP reinforcement on their tensile surfaces, were tested with a concentrated load at midspan under constant amplitude cyclic loading. The objective of this investigation is to establish the effect that these repair systems have on the fatigue behavior and remaining life of the girders. Results indicate that the fatigue behavior of such retrofit beams is controlled by the fatigue behavior of the reinforcing steel. The fatigue life of a reinforced concrete beam can be increased by the application of an FRP retrofit, which relieves some of the stress carried by the steel. The observed increase in fatigue life, however, is limited by the quality of the bond between the carbon FRP and concrete substrate. Debonding, initiating at midspan and progressing to a support, is common and is driven partially by the crack distribution and shear deformations of the beam.  相似文献   

16.
The MD 24 Bridge over Deer Creek in Harford County, Md., was one of the projects chosen by the Federal Highway Administration’s Innovative Bridge Research and Construction Program for bridge deck replacement by fiber-reinforced polymer (FRP) composites. A thorough discussion is presented on Maryland State Highway Administration’s first bridge rehabilitation project utilizing a FRP deck. The discussion includes design details, installation procedure, construction methods and in situ load testing with a wireless monitoring system. The research team installed a monitoring system to record the effects of live loads on the bridge system, including truss members, steel stringers, and plate action of the FRP deck. Finite-element models were also used in this phase. Dynamic effects of the FRP system, composite action between steel stringers and the FRP deck as well as the effective width and distribution factors of stringers were obtained and compared with the AASHTO specifications. Recommendations are also offered on improving the design details based on this experience.  相似文献   

17.
In addition to their high strength and light weight, fiber-reinforced polymer (FRP) composite reinforcing bars offer corrosion resistance, making them a promising alternative to traditional steel reinforcing bars in concrete bridge decks. FRP reinforcement has been used in several bridge decks recently constructed in North America. The Morristown Bridge, which is located in Vermont, United States, is a single span steel girder bridge with integral abutments spanning 43.90 m. The deck is a 230 mm thick concrete continuous slab over girders spaced at 2.36 m. The entire concrete deck slab was reinforced with glass FRP (GFRP) bars in two identical layers at the top and the bottom. The bridge is well instrumented at critical locations for internal temperature and strain data collection with fiber-optic sensors. The bridge was tested for service performance using standard truck loads. The construction procedure and field test results under actual service conditions revealed that GFRP rebar provides very good and promising performance.  相似文献   

18.
Fiber reinforced polymer (FRP) composite bridge decks are gaining the attention of bridge owners because of their light self-weight, corrosion resistance, and ease of installation. Constructed Facilities Center at West Virginia University working with the Federal Highway Administration and West Virginia Department of Transportation has developed three different FRP decking systems and installed several FRP deck bridges in West Virginia. These FRP bridge decks are lighter in weight than comparable concrete systems and therefore their dynamic performance is equally as important as their static performance. In the current study dynamic tests were performed on three FRP deck bridges, namely, Katy Truss Bridge, Market Street Bridge, and Laurel Lick Bridge, in the state of West Virginia. The dynamic response parameters evaluated for the three bridges include dynamic load allowance (DLA) factors, natural frequencies, damping ratios, and deck accelerations caused by moving test trucks. It was found that the DLA factors for Katy Truss and Market Street bridges are within the AASHTO 1998 LRFD specifications, but the deck accelerations were found to be high for both these bridges. DLA factors for Laurel Lick bridge were found to be as high as 93% against the typical design value of 33%; however absolute deck stress induced by vehicle loads is less than 10% of the deck ultimate stress.  相似文献   

19.
An experimental study of composite bridge decks with alternative shear connectors has been performed. The alternative shear connector consists of concrete filled holes located in the webs of grid main bars and friction along the web embedded in the slab, which enables shear transfer between the concrete slab and steel grid. Results of static and fatigue tests on full-scale prototype decks indicated that composite action between the concrete slab and steel grid is maintained well above the service load range even after fatigue loading, the eventual loss of composite action at overload is gradual, failure was controlled by punching shear of the concrete slab and was unaffected by the shear connectors, and no significant change in behavior was observed due to fatigue loading. Further, the measured stress range at the shear connection location would not control the fatigue behavior of the deck in positive bending, and no fatigue cracking of the steel grid was observed in negative bending.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号