Glass fiber-reinforced polymer (GFRP) bridge deck systems offer an attractive alternative to concrete decks, particularly for bridge rehabilitation projects. Current design practice treats GFRP deck systems in a manner similar to concrete decks, but the results of this study indicate that this approach may lead to nonconservative bridge girder designs. Results from a number of in situ load tests of three steel girder bridges having the same GFRP deck system are used to determine the degree of composite action that may be developed and the transverse distribution of wheel loads that may be assumed for such structures. Results from this work indicate that appropriately conservative design values may be found by assuming no composite action between a GFRP deck and steel girder and using the lever rule to determine transverse load distribution. Additionally, when used to replace an existing concrete deck, the lighter GFRP deck will likely result in lower total stresses in the supporting girders, although, due to the decreased effective width and increased distribution factors, the live-load-induced stress range is likely to be increased. Thus, existing fatigue-prone details may become a concern and require additional attention in design.  相似文献   

2.
Continuity diaphragms used in prestressed girder bridges on skewed bents have caused difficulties in detailing and construction. The results of the field verification for the effectiveness of continuity diaphragms for skewed, continuous, and prestressed concrete girder bridges are presented. The current design concept and bridge parameters that were considered include skew angle and the ratio of beam spacing to span (aspect ratio). A prestressed concrete bridge with continuity diaphragms and a skewed angle of 48° was selected for full-scale test by a team of engineers from Louisiana Department of Transportation and Development and the Federal Highway Administration. The live load tests performed with a comprehensive instrumentation plan provided a fundamental understanding of the load transfer mechanism through these diaphragms. The findings indicated that the effects of the continuity diaphragms were negligible and they can be eliminated. The superstructure of the bridge could be designed with link slab. Thus, the bridge deck would provide the continuity over the support, improve the riding quality, enhance the structural redundancy, and reduce the expansion joint installation and maintenance costs.  相似文献   

3.
This paper describes the behavior of hybrid girders consisting of fiber-reinforced polymer (FRP) bridge decks adhesively connected to steel main girders. Two large-scale girders were experimentally investigated at the serviceability and ultimate limit state as well as at failure. One of the girders was additionally fatigue loaded to 10 million cycles. Compared to the behavior of a reference steel girder, deflections of the two girders at the SLS were decreased by 30% and failure loads increased by 56% due to full composite action in the adhesive layer. A ductile failure mode occurred: Deck compression failure during yielding of the steel girder. The adhesive connections were able to prevent buckling of the yielding top steel flanges. Thus, compared to the reference steel girder, the maximum deflections at failure could be increased up to 130%. No deterioration due to fatigue loading was observed. Based on the experimental results, a conceptual design method for bonded FRP/steel girders was developed. The proposed method is based on the well-established design method for hybrid girders with concrete decks and shear stud connections. The necessary modifications are proposed.  相似文献   

4.
The AASHTO LRFD Bridge Design Specifications state that the spacing between the shear connectors for steel girders should not exceed 610 mm (24 in.). This decision was made based on research conducted more than three decades ago. The goal of this research is to investigate the possibility of extending this limit to 1,220 mm (48 in.) for stud clusters used with full-depth precast concrete deck panels installed on steel girders. This paper presents the history of the 610 mm (24 in.) limit, various formulas developed to calculate fatigue and design capacity for stud clusters and concerns about extending the current LRFD limit. This paper also presents information on the first phase of the experimental investigation, which is conducted on push-off specimens to validate extending the limit to 1,220 mm (48 in.).  相似文献   

5.
Redecking operations executed on urban bridges that experience large traffic volumes frequently require carefully orchestrated construction sequences carried out during times of nonpeak traffic. In such a construction environment, only bridge deck options that exhibit a high degree of modularity in conjunction with ease of installation are considered as viable options for a given redecking operation. As a further requirement, the deck installation must also be expected to perform essentially trouble free, with minimal maintenance, for very long periods of time in extremely harsh environments. The present research investigates the behavior of two new deck splice details for use in bridge applications involving precast concrete-filled steel grid deck panels. The research is primarily experimental in nature and is carried out using full-scale deck panel specimens. However, in an effort to better understand the experimental results, 3D finite-element models of the deck specimens are also constructed and studied. This paper summarizes the results from this experimental and analytical program of study.  相似文献   

6.
North Carolina has recently installed a fiber-reinforced polymer (FRP) deck on steel girders at a site in Union County. The bridge was instrumented with foil strain gauges, strain transducers, and displacement transducers. The bridge was then tested with a simulated MS-22.5 design load. Experimental data confirmed full composite interaction between the girders and the FRP deck panels. The neutral axis was measured to be 383?mm above the bottom flange of the 618-mm-deep girder. It was found that composite action could be estimated within 3% using a transformed section analysis of the deck panels. For two lanes loaded, the maximum live load distribution factor was computed to be 0.75. When looking at the overall performance of the structure, the deck deflected 5?mm, with the allowable stress at least 10 times over the maximum stress measured in the material. The girder deflection of 7?mm was well within the parameters set forth by AASHTO. Simple span deflection equations were found to conservatively model the anticipated deflection of the girders when using the transformed section properties.  相似文献   

7.
Glass fiber-reinforced polymer (GFRP) composite bridge decks behave differently than comparable reinforced concrete (RC) decks. GFRP decks exhibit reduced composite behavior (when designed to behave in a composite manner) and transverse distribution of forces. Both of these effects are shown to counteract the beneficial effects of a lighter deck structure and result in increased internal stresses in the supporting girders. The objective of this paper is to demonstrate through an illustrative example the implications of RC-to-GFRP deck replacement on superstructure stresses. It is also shown that, regardless of superstructure stresses, substructure forces will be uniformly reduced due to the lighter resulting superstructure.  相似文献   

8.
This paper reports on the monitoring and repair of a pilot field deployment of a glass fiber-reinforced polymer (GFRP) deck on a small steel girder bridge in the Washington State. Deck deflections were monitored periodically over a 10-month period and were found to increase significantly over that time. The GFRP deck is an adhesively bonded assembly of GFRP tubes and top and bottom plates. After 9 months of service, wearing surface cracking was observed, and upon closer inspection, the top GFRP plate was found to be delaminated from the tubes over a fairly large area. Deck deflections in the area of delamination were found to be considerably larger than those observed during previous monitoring in undamaged locations. A retrofit solution was employed where the top plate was reconnected to the tubes using screws coated with a two-part epoxy that mixed when they were driven. At the time of writing the retrofit was successful in reattaching the delaminated top plate.  相似文献   

9.
Innovative fiber-reinforced polymer (FRP) composite highway bridge deck systems are gradually gaining acceptance in replacing damaged/deteriorated concrete and timber decks. FRP bridge decks can be designed to meet the American Association of State Highway and Transportation Officials (AASHTO) HS-25 load requirements. Because a rather complex sub- and superstructure system is used to support the FRP deck, it is important to include the entire system in analyzing the deck behavior and performance. In this paper, we will present a finite-element analysis (FEA) that is able to consider the structural complexity of the entire bridge system and the material complexity of an FRP sandwich deck. The FEA is constructed using a two-step analysis approach. The first step is to analyze the global behavior of the entire bridge under the AASHTO HS-25 loading. The next step is to analyze the local behavior of the FRP deck with appropriate load and boundary conditions determined from the first step. For the latter, a layered FEA module is proposed to compute the internal stresses and deformations of the FRP sandwich deck. This approach produces predictions that are in good agreement with experimental measurements.  相似文献   

10.
One of the key assumptions in inelastic design is that members have adequate ductility to allow moments to redistribute. However, while AASHTO specifications contain moment redistribution provisions for steel I-girders, the amount of ductility that is adequate for this specific design situation has not been studied in detail. As a result, the scope of these specifications is limited to beam types known to have significant ductility, which restricts the use of these procedures and causes negative economic consequences. The goal of this work is to determine ductility requirements specifically applicable to AASHTO moment redistribution procedures that are valid for all I-girders. This is accomplished through an analytical procedure, detailed herein. The results of this work are empirical equations predicting the amount of rotation required as a function of the intended level of moment redistribution as well as the material properties and span configuration of the girder. With these requirements known, there is a basis for reducing the overly conservative nature of the existing AASHTO moment redistribution specifications.  相似文献   

11.
The lateral-torsional buckling capacity of steel bridge girders is often increased by incorporating bracing along the girder length. Permanent metal deck forms (PMDF) that are used to support the wet concrete deck during bridge construction are a likely source of stability bracing; however, their bracing performance is greatly limited by flexibility in the connections currently used with the formwork. This paper outlines results from a research study that assessed and improved the bracing potential of metal deck forms used in bridge applications. The research study included shear tests of PMDF panels, and also lateral displacement and buckling tests of twin girder systems braced with PMDF. This paper will provide key results from the shear panel tests and then focus on the lateral displacement tests. Parametric investigations of PMDF bracing behavior were conducted using finite-element analyses and the results from the lateral displacement tests served a critical role in calibrating the finite element models. This paper documents key results from lateral load tests of 17 girder–PMDF systems using a variety of bracing details and PMDF thickness values.  相似文献   

12.
Large Shear Studs for Composite Action in Steel Bridge Girders   总被引:1,自引:0,他引:1  
Shear studs used in composite steel bridge construction are typically 19.1 mm (? in.) or 22.2 mm (? in.) in diameter. This paper presents the development and implementation of the 31.8 mm (1??in.) stud diameter. Because the 31.8 mm (1??in.) stud has about twice the strength and a higher fatigue capacity than the 22.2 mm (? in.) stud, fewer studs are required along the length of the steel girder. This would increase bridge construction speed and future deck replacement, and reduce the possibility of damage to the studs and girder top flange during deck removal. Studs also can be placed in one row only, over the web centerline, freeing up most of the top flange width and improving safety conditions for field workers. This paper provides information on the development, welding, quality control, and testing of the 31.8 mm (1??in.) stud. Information on the first bridge built in the state of Nebraska with the 31.8 mm (1??in.) studs is provided.  相似文献   

13.
This paper discusses the development of an innovative and efficient connector to be used with fiber reinforced polymer (FRP) decks supported by steel girders. A summary is provided detailing various proprietary connectors currently employed by FRP deck manufacturers. The paper then describes the development and experimental testing of a clamped shear stud-type connector. Experimental testing was conducted in two phases. The first phase consisted of individual connector testing. In this phase, several variations of the connector are tested and evaluated for strength, damage development, and overall performance. Results of this phase of testing are used to select a final connection design to be used in the second phase of testing, which consisted of testing a scale model bridge that incorporates several of the proposed connectors. The bridge is subjected to static load tests and the resulting reactions and deflections from these tests are compared with comprehensive finite element models of the system.  相似文献   

14.
No appropriate provisions from either AASHTO Standard (2002) or AASHTO LRFD (2004) bridge design specifications are available for the design of fiber-reinforced polymer (FRP)-deck-on-steel-superstructure bridges. In this research, a parametric study using the finite-element method (FEM) is conducted to examine two design issues concerning the design of FRP-deck-on-steel-superstructure bridges, namely deck relative deflection and load distribution factor (LDF). Results show that the strip method specified in AASHTO LRFD specification as an approximate method of analysis, can also be applied to FRP decks as a practical method. However, different strip width equations have to be determined by either FEM or experimental methods for different types of FRP decks. In this study, one such equation has been derived for the Strongwell deck. In addition, both FEM results and experimental measurements show that the AASHTO LDF equations for glued laminated timber decks on steel stringers provide good estimations of LDF for FRP-deck-on-steel-superstructure bridges. Finally, it is found that the lever rule can be used as an appropriately conservative design method to predict the LDF of FRP-deck-on-steel-superstructure bridges.  相似文献   

15.
Creep and shrinkage in concrete deck of steel-concrete composite bridges can result in significant redistribution and consequent increase in bending moments at continuity supports and also increase in deflections. Studies are presented for the control of creep and shrinkage effects in steel-concrete composite bridges with precast concrete decks. A hybrid procedure recently developed by the authors has been used for carrying out the studies. The procedure accounts for creep, shrinkage and progressive cracking in concrete decks. Single span, three span and five span bridges have been analyzed for different thicknesses of concrete decks and grades of concrete. Both the shored and unshored constructions have been considered. It is shown that, for both constructions, the increase in bending moments and midspan deflections can be controlled to a significant degree, without putting constraints on design parameters, by simply delaying the time of mobilization of composite action between the precast concrete deck panels and the steel section. It is also observed that though the percentage change in bending moments due to creep and shrinkage is similar for shored and unshored constructions, the percentage change in midspan deflection is significantly higher for shored construction.  相似文献   

16.
Precast deck panels are increasingly being utilized to reduce construction times and traffic delays as many departments of transportation (DOTs) emphasize accelerated bridge construction. Despite the short-term benefits, the connections between panels have a history of service failure. This research focused on the evaluation of the service and ultimate capacities of five precast deck panel connections. Full-scale tests were developed to determine the cracking and ultimate flexural strengths of two welded connections, a conventionally posttensioned connection, and two newly proposed, posttensioned, curved bolt connections. The conventionally posttensioned specimens were shown to perform well with the highest cracking loads and 0.42 times the theoretical capacity of a continuously reinforced concrete deck panel. The proposed curved bolt connections were shown to be a promising connection detail with approximately 0.5 times the theoretical capacity of a continuously reinforced panel. Data from the welded specimens showed that some welded connection types perform significantly better than others. The experimental results also compared closely with values calculated on the basis of finite-element modeling, which can be used for future analytical studies.  相似文献   

17.
This paper presents results of an evaluation of the fatigue performance of a novel steel-free fiber-reinforced polymer (FRP)–concrete modular bridge deck system consisting of wet layup FRP–concrete deck panels which serve as both formwork and flexural reinforcement for the steel-free concrete slab cast on top. A two-span continuous deck specimen was subjected to a total of 2.36 million cycles of load simulating an AASHTO HS20 design truck with impact at low and high magnitudes. Quasistatic load tests were conducted both before initiation of fatigue cycling and after predetermined numbers of cycles to evaluate the system response. No significant stiffness degradation was observed during the first 2 million cycles of fatigue service load. A level of degradation was observed during subsequent testing at higher magnitudes of fatigue load. A fairly elastic and stable response was obtained from the system under fatigue service load with little residual displacement. The system satisfied both strength and serviceability limit states with respect to the code requirements for crack width and deflection.  相似文献   

18.
Fiber-reinforced polymer (FRP) composite bridge deck panels are high-strength, corrosion resistant, weather resistant, etc., making them attractive for use in new construction or retrofit of existing bridges. This study evaluated the force-deformation responses of FRP composite bridge deck panels under AASHTO MS 22.5 (HS25) truck wheel load and up to failure. Tests were conducted on 16 FRP composite deck panels and four reinforced concrete conventional deck panels. The test results of FRP composite deck panels were compared with the flexural, shear, and deflection performance criteria per Ohio Department of Transportation specifications, and with the test results of reinforced concrete deck panels. The flexural and shear rigidities of FRP composite deck panels were calculated. The response of all panels under service load, factored load, cyclic loading, and the mode of failure were reported. The tested bridge deck panels satisfied the performance criteria. The safety factor against failure varies from 3 to 8.  相似文献   

19.
This paper reports on research investigating a nongrouted sleeve-type connection used to attach fiber-reinforced polymer (FRP) decks to steel girders. The connection system was investigated for stiffness, strength, fatigue resistance, and degree of composite action. Static and fatigue tests were conducted first at the component level on push-out specimens to obtain P-Δ (load-displacement) and S-N (stress range–fatigue life) relationships, from which design formulas were developed. Then tests were conducted at the system level on a 1∶3 scaled-bridge model by using this sleeve-type connection, and the results showed this shear connection can satisfy requirements from AASHTO specifications for fatigue, strength, and function. Further, three-point bending tests were conducted on a T-section model cut from the scaled bridge, and approximately 25% composite action was achieved for two different connection spacings. The structural efficiency of this shear connection is shown, and this connection design is applied in practice.  相似文献   

20.
Glass fiber-reinforced polymer (GFRP) materials possess inherently high strength-to-weight ratios, but their effective elastic moduli are low relative to civil engineering (CE) construction materials. While elastic modulus may be comparable to that of some CE materials, the lower shear modulus adversely affects stiffness. As a result, serviceability issues are what govern GFRP deck design in the CE bridge industry. An innovative solution to increase the stiffness of a commercial GFRP reinforced-sinusoidal honeycomb sandwich panel was proposed; this solution would completely replace the GFRP honeycomb core with a hexagonal honeycomb core constructed from commercial steel roof decking. The purpose of this study was to perform small-scale tests to characterize the steel hexagonal honeycomb core equivalent elastic moduli in an effort to simplify the modeling of the core. The steel core equivalent moduli experimental results were compared with theoretical hexagonal honeycomb elastic modulus equations from the literature, demonstrating the applicability of the theoretical equations to the steel honeycomb core. Core equivalent elastic modulus equations were then proposed to model and characterize the steel hexagonal honeycomb as applicable to sandwich panel design. The equivalent honeycomb core will enable an efficient sandwich panel stiffness design technique, both for structural analysis methods (i.e., hand calculations) and finite-element analysis procedures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号