首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Studies have demonstrated that electrolyzed oxidizing (EO) water is effective in reducing foodborne pathogens on fresh produce. This study was undertaken to determine the efficacy of EO water and two different forms of chlorinated water (chlorine water from Cl2 and Ca(OCl)2 as sources of chlorine) in inactivating Salmonella on alfalfa seeds and sprouts. Tengram sets of alfalfa seeds inoculated with a five-strain cocktail of Salmonella (6.3 x 10(4) CFU/g) were subjected to 90 ml of deionized water (control), EO water (84 mg/liter of active chlorine), chlorine water (84 mg/liter of active chlorine), and Ca(OCl)2 solutions at 90 and 20,000 mg/liter of active chlorine for 10 min at 24 +/- 2 degrees C. The application of EO water, chlorinated water, and 90 mg/liter of Ca(OCl)2 to alfalfa seeds for 10 min reduced initial populations of Salmonella by at least 1.5 log10 CFU/g. For seed sprouting, alfalfa seeds were soaked in the different treatment solutions described above for 3 h. Ca(OCl)2 (20,000 mg/liter of active chlorine) was the most effective treatment in reducing the populations of Salmonella and non-Salmonella microflora (4.6 and 7.0 log10 CFU/g, respectively). However, the use of high concentrations of chlorine generates worker safety concerns. Also, the Ca(OCl)2 treatment significantly reduced seed germination rates (70% versus 90 to 96%). For alfalfa sprouts, higher bacterial populations were recovered from treated sprouts containing seed coats than from sprouts with seed coats removed. The effectiveness of EO water improved when soaking treatments were applied to sprouts in conjunction with sonication and seed coat removal. The combined treatment achieved 2.3- and 1.5-log10 CFU/g greater reductions than EO water alone in populations of Salmonella and non-Salmonella microflora, respectively. This combination treatment resulted in a 3.3-log10 CFU/g greater reduction in Salmonella populations than the control (deionized water) treatment.  相似文献   

2.
Electrolyzed oxidizing water is a relatively new concept that has been utilized in agriculture, livestock management, medical sterilization, and food sanitation. Electrolyzed oxidizing (EO) water generated by passing sodium chloride solution through an EO water generator was used to treat alfalfa seeds and sprouts inoculated with a five-strain cocktail of nalidixic acid resistant Escherichia coli O157:H7. EO water had a pH of 2.6, an oxidation-reduction potential of 1150 mV and about 50 ppm free chlorine. The percentage reduction in bacterial load was determined for reaction times of 2, 4, 8, 16, 32, and 64 min. Mechanical agitation was done while treating the seeds at different time intervals to increase the effectiveness of the treatment. Since E. coli O157:H7 was released due to soaking during treatment, the initial counts on seeds and sprouts were determined by soaking the contaminated seeds/sprouts in 0.1% peptone water for a period equivalent to treatment time. The samples were then pummeled in 0.1% peptone water and spread plated on tryptic soy agar with 5 microg/ml of nalidixic acid (TSAN). Results showed that there were reductions between 38.2% and 97.1% (0.22-1.56 log(10) CFU/g) in the bacterial load of treated seeds. The reductions for sprouts were between 91.1% and 99.8% (1.05-2.72 log(10) CFU/g). An increase in treatment time increased the percentage reduction of E. coli O157:H7. However, germination of the treated seeds reduced from 92% to 49% as amperage to make EO water and soaking time increased. EO water did not cause any visible damage to the sprouts.  相似文献   

3.
To evaluate the potential of using electrolyzed oxidizing (EO) water for controlling Escherichia coli O157:H7 in water for livestock, the effects of water source, electrolyte concentration, dilution, storage conditions, and bacterial or fecal load on the oxidative reduction potential (ORP) and bactericidal activity of EO water were investigated. Anode and combined (7:3 anode:cathode, vol/vol) EO waters reduced the pH and increased the ORP of deionized water, whereas cathode EO water increased pH and lowered ORP. Minimum concentrations (vol/vol) of anode and combined EO waters required to kill 10(4) CFU/ml planktonic suspensions of E. coli O157:H7 strain H4420 were 0.5 and 2.0%, respectively. Cathode EO water did not inhibit H4420 at concentrations up to 16% (vol/vol). Higher concentrations of anode or combined EO water were required to elevate the ORP of irrigation or chlorinated tap water compared with that of deionized water. Addition of feces to EO water products (0.5% anode or 2.0% combined, vol/vol) significantly reduced (P < 0.001) their ORP values to < 700 mV in all water types. A relationship between ORP and bactericidal activity of EO water was observed. The dilute EO waters retained the capacity to eliminate a 10(4) CFU/ml inoculation of E. coli O157:H7 H4420 for at least 70 h regardless of exposure to UV light or storage temperature (4 versus 24 degrees C). At 95 h and beyond, UV exposure reduced ORP, significantly more so (P < 0.05) in open than in closed containers. Bactericidal activity of EO products (anode or combined) was lost in samples in which ORP value had fallen to < or = 848 mV. When stored in the dark, the diluted EO waters retained an ORP of > 848 mV and bactericidal efficacy for at least 125 h; with refrigeration (4 degrees C), these conditions were retained for at least 180 h. Results suggest that EO water may be an effective means by which to control E. coli O157:H7 in livestock water with low organic matter content.  相似文献   

4.
This study investigates the properties of electrolyzed oxidizing (EO) water for the inactivation of pathogen and to evaluate the chemically modified solutions possessing properties similar to EO water in killing Escherichia coli O157:H7. A five-strain cocktail (10(10) CFU/ml) of E. coli O157:H7 was subjected to deionized water (control), EO water with 10 mg/liter residual chlorine (J.A.W-EO water), EO water with 56 mg/liter residual chlorine (ROX-EO water), and chemically modified solutions. Inactivation (8.88 log10 CFU/ml reduction) of E. coli O157:H7 occurred within 30 s after application of EO water and chemically modified solutions containing chlorine and 1% bromine. Iron was added to EO or chemically modified solutions to reduce oxidation-reduction potential (ORP) readings and neutralizing buffer was added to neutralize chlorine. J.A.W-EO water with 100 mg/liter iron, acetic acid solution, and chemically modified solutions containing neutralizing buffer or 100 mg/liter iron were ineffective in reducing the bacteria population. ROX-EO water with 100 mg/liter iron was the only solution still effective in inactivation of E. coli O157:H7 and having high ORP readings regardless of residual chlorine. These results suggest that it is possible to simulate EO water by chemically modifying deionized water and ORP of the solution may be the primary factor affecting microbial inactivation.  相似文献   

5.
Food safety issues and increases in food borne illnesses have promulgated the development of new sanitation methods to eliminate pathogenic organisms on foods and surfaces in food service areas. Electrolyzed oxidizing water (EO water) shows promise as an environmentally friendly broad spectrum microbial decontamination agent. EO water is generated by the passage of a dilute salt solution ( approximately 1% NaCl) through an electrochemical cell. This electrolytic process converts chloride ions and water molecules into chlorine oxidants (Cl(2), HOCl/ClO(-)). At a near-neutral pH (pH 6.3-6.5), the predominant chemical species is the highly biocidal hypochlorous acid species (HOCl) with the oxidation reduction potential (ORP) of the solution ranging from 800 to 900mV. The biocidal activity of near-neutral EO water was evaluated at 25 degrees C using pure cultures of Escherichia coli, Salmonella typhimurium, Staphylococcus aureus, Listeria monocytogenes, and Enterococcus faecalis. Treatment of these organisms, in pure culture, with EO water at concentrations of 20, 50, 100, and 120ppm total residual chlorine (TRC) and 10min of contact time resulted in 100% inactivation of all five organisms (reduction of 6.1-6.7log(10)CFU/mL). Spray treatment of surfaces in food service areas with EO water containing 278-310ppm TRC (pH 6.38) resulted in a 79-100% reduction of microbial growth. Dip (10min) treatment of spinach at 100 and 120ppm TRC resulted in a 4.0-5.0log(10)CFU/mL reduction of bacterial counts for all organisms tested. Dipping (10min) of lettuce at 100 and 120ppm TRC reduced bacterial counts of E. coli by 0.24-0.25log(10)CFU/mL and reduced all other organisms by 2.43-3.81log(10)CFU/mL.  相似文献   

6.
Hao J  Wuyundalai  Liu H  Chen T  Zhou Y  Su YC  Li L 《Journal of food science》2011,76(4):C520-C524
Degradation of the 3 pesticides (acephate, omethoate, and dimethyl dichloroviny phosphate [DDVP]) by electrolyzed water was investigated. These pesticides were commonly used as broad-spectrum insecticides in pest control and high-residual levels had been detected in vegetables. Our research showed that the electrolyzed oxidizing (EO) water (pH 2.3, available chlorine concentration:70 ppm, oxidation-reduction potential [ORP]: 1170 mV) and the electrolyzed reducing (ER) water (pH 11.6, ORP: -860 mV) can reduce the pesticide residues effectively. Pesticide residues on fresh spinach after 30 min of immersion in electrolyzed water reduced acephate by 74% (EO) and 86% (ER), omethoate by 62% (EO) and 75% (ER), DDVP by 59% (EO) and 46% (ER), respectively. The efficacy of using EO water or ER water was found to be better than that of using tap water or detergent (both were reduced by more than 25%). Besides spinach, the cabbage and leek polluted by DDVP were also investigated and the degradation efficacies were similar to the spinach. Moreover, we found that the residual level of pesticide residue decreased with prolonged immersion time. Using EO or ER water to wash the vegetables did not affect the contents of Vitamin C, which inferred that the applications of EO or ER water to wash the vegetables would not result in loss of nutrition.  相似文献   

7.
This study was undertaken to evaluate the efficacy of electrolyzed oxidizing (EO) and chemically modified water with properties similar to the EO water for inactivation of different types of foodborne pathogens (Escherichia coli O157:H7, Listeria monocytogenes and Bacillus cereus). A five-strain cocktail of each microorganism was exposed to deionized water (control), EO water and chemically modified water. To evaluate the effect of individual properties (pH, oxidation-reduction potential (ORP) and residual chlorine) of treatment solutions on microbial inactivation, iron was added to reduce ORP readings and neutralizing buffer was added to neutralize chlorine. Inactivation of E. coli O157:H7 occurred within 30 s after application of JAW EO water with 10 mg/l residual chlorine and chemically modified solutions containing 13 mg/l residual chlorine. Inactivation of Gram-positive and -negative microorganisms occurred within 10 s after application of ROX EO water with 56 mg/l residual chlorine and chemically modified solutions containing 60 mg/l residual chlorine. B. cereus was more resistant to the treatments than E. coli O157:H7 and L. monocytogenes and only 3 log10 reductions were achieved after 10 s of ROX EO water treatment. B. cereus spores were the most resistant pathogen. However, more than 3 log10 reductions were achieved with 120-s EO water treatment.  相似文献   

8.
The effects of various sanitizers on the viability and cellular injury to structures of Escherichia coli and Listeria innocua were investigated. A food grade organic acidic formulation (pH 2.5) and acidic, neutral, and basic electrolyzed water [AEW (pH 2.7, oxidation reduction potential; ORP: 1100 mV, free available chlorine; FAC: 150 ppm), NEW (pH 6.9, ORP: 840 mV, FAC: 150 ppm), BEW (pH 11.6, ORP: -810 mV)] were used to treat E. coli and L. innocua cells. After 10 min of exposure to the sanitizers, changes to the bacterial numbers and cell structures were evaluated by plate counting and transmission electron microscopy (TEM), respectively. It was concluded from the results that the sanitizers reduced the E. coli cells between 2 and 3 log CFU/mL. Except for the BEW treatment, reductions in L. innocua population were greater (>1 log CFU/mL) than that of E. coli for all treatments. Data from the TEM showed that all sanitizers caused changes to the cell envelope and cytoplasm of both organisms. However, smaller changes were observed for L. innocua cells. Decrease in the integrity of the cell envelope and aggregation of the cytoplasmic components appeared to be mainly because of exposure to the sanitizers. The organic acid formulation and AEW were the most effective sanitizers against bacterial cells, indicating that penetration of acidic substances effectively caused the cell inactivation. PRACTICAL APPLICATION: An understanding of the method in which E-water and an acidic sanitizer cause injury to E. coli and L. innocua would be helpful in selecting an effective chemical agent as a food safety tool. This will allow a scientist to target similar microorganisms such as food borne bacteria with structures that are vulnerable to the sanitizer.  相似文献   

9.
Decontamination of lettuce using acidic electrolyzed water   总被引:7,自引:0,他引:7  
The disinfectant effect of acidic electrolyzed water (AcEW), ozonated water, and sodium hypochlorite (NaOCl) solution on lettuce was examined. AcEW (pH 2.6; oxidation reduction potential, 1140 mV; 30 ppm of available chlorine) and NaOCl solution (150 ppm of available chlorine) reduced viable aerobes in lettuce by 2 log CFU/g within 10 min. For lettuce washed in alkaline electrolyzed water (AIEW) for 1 min and then disinfected in AcEW for 1 min, viable aerobes were reduced by 2 log CFU/g. On the other hand, ozonated water containing 5 ppm of ozone reduced viable aerobes in lettuce 1.5 log CFU/g within 10 min. It was discovered that AcEW showed a higher disinfectant effect than did ozonated water significantly at P < 0.05. It was confirmed by swabbing test that AcEW, ozonated water, and NaOCI solution removed aerobic bacteria, coliform bacteria, molds, and yeasts on the surface of lettuce. Therefore, residual microorganisms after the decontamination of lettuce were either in the inside of the cellular tissue, such as the stomata, or making biofilm on the surface of lettuce. Biofilms were observed by a scanning electron microscope on the surface of the lettuce treated with AcEW. Moreover, it was shown that the spores of bacteria on the surface were not removed by any treatment in this study. However, it was also observed that the surface structure of lettuce was not damaged by any treatment in this study. Thus, the use of AcEW for decontamination of fresh lettuce was suggested to be an effective means of controlling microorganisms.  相似文献   

10.
The efficacy of acidic electrolyzed (EO) water produced at three levels of total available chlorine (16, 41, and 77 mg/ liter) and chlorinated water with 45 and 200 mg/liter of residual chlorine was investigated for inactivating Salmonella Enteritidis and Listeria monocytogenes on shell eggs. An increasing reduction in Listeria population was observed with increasing chlorine concentration from 16 to 77 mg/liter and treatment time from 1 to 5 min, resulting in a maximal reduction of 3.70 log CFU per shell egg compared with a deionized water wash for 5 min. There was no significant difference in antibacterial activities against Salmonella and Listeria at the same treatment time between 45 mg/liter of chlorinated water and 14-A acidic EO water treatment (P > or = 0.05). Chlorinated water (200 mg/liter) wash for 3 and 5 min was the most effective treatment; it reduced mean populations of Listeria and Salmonella on inoculated eggs by 4.89 and 3.83 log CFU/shell egg, respectively. However, reductions (log CFU/shell egg) of Listeria (4.39) and Salmonella (3.66) by 1-min alkaline EO water treatment followed by another 1 min of 14-A acidic EO water (41 mg/liter chlorine) treatment had a similar reduction to the 1-min 200 mg/liter chlorinated water treatment for Listeria (4.01) and Salmonella (3.81). This study demonstrated that a combination of alkaline and acidic EO water wash is equivalent to 200 mg/liter of chlorinated water wash for reducing populations of Salmonella Enteritidis and L. monocytogenes on shell eggs.  相似文献   

11.
To identify the primary component responsible in electrolyzed oxidizing (EO) water for inactivation, this study determined the concentrations of hypochlorous acid (HOCl) and hypochlorite ions (OCl-) and related those concentrations to the microbicidal activity of the water. The ultraviolet absorption spectra were used to determine the concentrations of HOCl and OCl- in EO water and the chemical equilibrium of these species with change in pH and amperage. EO water generated at higher amperage contained a higher chlorine concentration. The maximum concentration of HOCl was observed around pH 4 where the maximum log reduction (2.3 log10 CFU/ml) of Bacillus cereus F4431/73 vegetative cells also occurred. The high correlation (r = 0.95) between HOCl concentrations and bactericidal effectiveness of EO water supports HOCl's role as the primary inactivation agent. Caution should be taken with standard titrimetric methods for measurement of chlorine as they cannot differentiate the levels of HOCl present in EO water of varying pHs.  相似文献   

12.
Contamination of Vibrio parahaemolyticus and Vibrio vulnificus in oysters is a food safety concern. This study investigated effects of electrolyzed oxidizing (EO) water treatment on reducing V. parahaemolyticus and V. vulnificus in laboratory-contaminated oysters. EO water exhibited strong antibacterial activity against V. parahaemolyticus and V. vulnificus in pure cultures. Populations of V. parahaemolyticus (8.74 x 10(7) CFU/ml) and V. vulnificus (8.69 x 10(7) CFU/ml) decreased quickly in EO water containing 0.5% NaCl to nondetectable levels (> 6.6 log reductions) within 15 s. Freshly harvested Pacific oysters were inoculated with a five-strain cocktail of V. parahaemolyticus or V. vulnificus at levels of 10(4) and 10(6) most probable number (MPN)/g and treated with EO water (chlorine, 30 ppm; pH 2.82; oxidation-reduction potential, 1131 mV) containing 1% NaCl at room temperature. Reductions of V. parahaemolyticus and V. vulnificus in oysters were determined at 0 (before treatment), 2, 4, 6, and 8 h of treatment. Holding oysters inoculated with V. parahaemolyticus or V. vulnificus in the EO water containing 1% NaCl for 4 to 6 h resulted in significant (P < 0.05) reductions of V. parahaemolyticus and V. vulnificus by 1.13 and 1.05 log MPN/g, respectively. Extended exposure (> 12 h) of oysters in EO water containing high levels of chlorine (> 30 ppm) was found to be detrimental to oysters. EO water could be used as a postharvest treatment to reduce Vibrio contamination in oysters. However, treatment should be limited to 4 to 6 h to avoid death of oysters. Further studies are needed to determine effects of EO water treatment on sensory characteristics of oysters.  相似文献   

13.
The effects of electrolyzed oxidizing (EO) water on reducing Listeria monocytogenes contamination on seafood processing surfaces were studied. Chips (5 x 5 cm(2)) of stainless steel sheet (SS), ceramic tile (CT), and floor tile (FT) with and without crabmeat residue on the surface were inoculated with L. monocytogenes and soaked in tap or EO water for 5 min. Viable cells of L. monocytogenes were detected on all chip surfaces with or without crabmeat residue after being held at room temperature for 1 h. Soaking contaminated chips in tap water resulted in small-degree reductions of the organism (0.40-0.66 log cfu/chip on clean surfaces and 0.78-1.33 log cfu/chip on dirty surfaces). Treatments of EO water significantly (p<0.05) reduced L. monocytogenes on clean surfaces (3.73 log on SS, 4.24 log on CT, and 5.12 log on FT). Presence of crabmeat residue on chip surfaces reduced the effectiveness of EO water on inactivating Listeria cells. However, treatments of EO water also resulted in significant reductions of L. monocytogenes on dirty surfaces (2.33 log on SS and CT and 1.52 log on FT) when compared with tap water treatments. The antimicrobial activity of EO water was positively correlated with its chlorine content. High oxidation-reduction potential (ORP) of EO water also contributed significantly to its antimicrobial activity against L. monocytogenes. EO water was more effective than chlorine water on inactivating L. monocytogenes on surfaces and could be used as a chlorine alternative for sanitation purpose. Application of EO water following a thorough cleaning process could greatly reduce L. monocytogenes contamination in seafood processing environments.  相似文献   

14.
In this study, the effectiveness of dry-heat treatment in combination with chemical treatments (electrolyzed oxidizing [EO] water, califresh-S, 200 ppm of active chlorinated water) with and without sonication in eliminating Escherichia coli O157:H7 on laboratory-inoculated alfalfa, radish, and mung bean seeds was compared with that of dry-heat treatment in combination with irradiation treatment. The treatment of mung bean seeds with EO water in combination with sonication followed by a rinse with sterile distilled water resulted in reductions of approximately 4.0 log10 CFU of E. coli O157:H7 per g. whereas reductions of ca. 1.52 and 2.64 log10 CFU/g were obtained for radish and alfalfa seeds. The maximum reduction (3.70 log10 CFU/g) for mung bean seeds was achieved by treatment with califresh-S and chlorinated water (200 ppm) in combination with sonication and a rinse. The combination of dry heat, hot EO water treatment, and sonication was able to eliminate pathogen populations on mung bean seeds but was unable to eliminate the pathogen on radish and alfalfa seeds. Other chemical treatments used were effective in greatly reducing pathogen populations on radish and alfalfa seeds without compromising the quality of the sprouts, but these treatments did not result in the elimination of pathogens from radish and alfalfa seeds. Moreover, a combination of dry-heat and irradiation treatments was effective in eliminating E. coli O157:H7 on laboratory-inoculated alfalfa, radish, and mung bean seeds. An irradiation dose of 2.0 kGy in combination with dry heat eliminated E. coli O157:H7 completely from alfalfa and mung bean seeds, whereas a 2.5-kGy dose of irradiation was required to eliminate the pathogen completely from radish seeds. Dry heat in combination with irradiation doses of up to 2.0 kGy did not unacceptably decrease the germination percentage for alfalfa seeds or the length of alfalfa sprouts but did decrease the lengths of radish and mung bean sprouts.  相似文献   

15.
The use of water flotation tanks during apple packing increases the risk of contamination of apples by spores of Penicillium expansum, which may accumulate in the recirculating water. Routine addition of sanitizers to the water may prevent such contamination. Sodium hypochlorite (NaOCl), chlorine dioxide (ClO2), and electrolyzed oxidizing (EO) water have varied activity against spores of P. expansum, and their effectiveness could be enhanced using surfactants. The objective of this study was to determine the ability of three nonionic surfactants, polyoxyethylene sorbitan monooleate (Tween 80), polyoxyethylene sorbitan monolaurate (Tween 20), and sorbitan monolaurate (Span 20), to enhance the efficacy of NaOCl, ClO2, and EO water against spores of P. expansum in aqueous suspension at various temperatures and pH conditions. The efficacy of NaOCl solutions was enhanced by the addition of surfactants at both pH 6.3 and pH 8 (up to 5 log CFU reduction). EO water and ClO2 were effective against P. expansum spores (up to 5 log CFU and 4 log CFU reduction, respectively), but addition of surfactants was not beneficial. All solutions were less effective at 4 degrees C compared to 24 degrees C irrespective of the presence of surfactants. Nonionic surfactants could potentially be used with NaOCl to improve control of P. expansum in flotation tanks, but the efficacy of such formulations should be validated under apple packing conditions.  相似文献   

16.
Electrolyzed oxidizing (EO) water has proved to be effective against foodborne pathogens attached to cutting boards and poultry surfaces and against spoilage organisms on vegetables; however, its levels of effectiveness against Listeria monocytogenes and Salmonella Typhimurium in cell suspensions have not been compared with those of other treatments. In this study, the oxidation reduction potentials (ORPs), chlorine concentrations, and pHs of acidic and basic EO water were monitored for 3 days at 4 and 25 degrees C after generation. There were no differences between the pHs or ORPs of acidic and basic EO waters stored at 4 or 25 degrees C. However, the free chlorine concentration in acidic EO water stored at 4 degrees C increased after 24 h. In contrast, the free chlorine concentration in acidic EO water stored at 25 degrees C decreased after one day. Cell suspensions of Salmonella Typhimurium and L. monocytogenes were treated with distilled water, chlorinated water (20 ppm), acidified chlorinated water (20 ppm, 4.5 pH), acidic EO water (EOA), basic EO water (EOB), or acidic EO water that was "aged" at 4 degrees C for 24 h (AEOA) for up to 15 min at either 4 or 25 degrees C. The largest reductions observed were those following treatments carried out at 25 degrees C. EOA and AEOA treatments at both temperatures significantly reduced Salmonella Typhimurium populations by > 8 log10 CFU/ml. EOA and AEOA treatments effectively reduced L. monocytogenes populations by > 8 log10 CFU/ml at 25degrees C. These results demonstrate the stability of EO water under different conditions and that EO water effectively reduced Salmonella Typhimurium and L. monocytogenes populations in cell suspensions.  相似文献   

17.
Recent foodborne outbreaks implicating spinach and lettuce have increased consumer concerns regarding the safety of fresh produce. While the most common commercial antimicrobial intervention for fresh produce is wash water containing 50 to 200 ppm chlorine, this study compares the effectiveness of acidified sodium chlorite, chlorine, and acidic electrolyzed water for inactivating Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes inoculated onto leafy greens. Fresh mixed greens were left uninoculated or inoculated with approximately 6 log CFU/g of E. coli O157:H7, Salmonella, and L. monocytogenes and treated by immersion for 60 or 90 s in different wash solutions (1:150, wt/vol), including 50 ppm of chlorine solution acidified to pH 6.5, acidic electrolyzed water (pH 2.1 +/- 0.2, oxygen reduction potential of 1,100 mV, 30 to 35 ppm of free chlorine), and acidified sodium chlorite (1,200 ppm, pH 2.5). Samples were neutralized and homogenized. Bacterial survival was determined by standard spread plating on selective media. Each test case (organism x treatment x time) was replicated twice with five samples per replicate. There was no difference (P > or = 0.05) in the time of immersion on the antimicrobial effectiveness of the treatments. Furthermore, there was no difference (P > or = 0.05) in survival of the three organisms regardless of treatment or time. Acidified sodium chlorite, resulted in reductions in populations of 3 to 3.8 log CFU/g and was more effective than chlorinated water (2.1 to 2.8 log CFU/g reduction). These results provide the produce industry with important information to assist in selection of effective antimicrobial strategies.  相似文献   

18.
The effectiveness of electrolyzed (EO) water at killing Enterobacter aerogenes and Staphylococcus aureus in pure culture was evaluated. One milliliter (approximately 10(9) CFU/ml) of each bacterium was subjected to 9 ml of EO water or control water (EO water containing 10% neutralizing buffer) at room temperature for 30 s. Inactivation (reduction of > 9 log10 CFU/ ml) of both pathogens occurred within 30 s after exposure to EO water containing approximately 25 or 50 mg of residual chlorine per liter. The effectiveness of EO water in reducing E. aerogenes and S. aureus on different surfaces (glass, stainless steel, glazed ceramic tile, unglazed ceramic tile, and vitreous china) was also evaluated. After immersion of the tested surfaces in EO water for 5 min without agitation, populations of E. aerogenes and S. aureus were reduced by 2.2 to 2.4 log10 CFU/ cm2 and by 1.7 to 1.9 log10 CFU/cm2, respectively, whereas washing with control water resulted in a reduction of only 0.1 to 0.3 log10 CFU/cm2. The washing of tested surfaces in EO water with agitation (50 rpm) reduced populations of viable cells on the tested surfaces to < 1 CFU/cm2. For the control water treatment with agitation, the surviving numbers of both strains on the tested surfaces were approximately 3 log10 CFU/cm2. No viable cells of either strain were observed in the EO water after treatment, regardless of agitation. However, large populations of both pathogens were recovered from control wash solution after treatment.  相似文献   

19.
The effectiveness of electrolyzed (EO) water for killing Campylobacter jejuni on poultry was evaluated. Complete inactivation of C. jejuni in pure culture occurred within 10 s after exposure to EO or chlorinated water, both of which contained 50 mg/l of residual chlorine. A strong bactericidal activity was also observed on the diluted EO water (containing 25 mg/l of residual chlorine) and the mean population of C. jejuni was reduced to less than 10 CFU/ml (detected only by enrichment for 48 h) after 10-s treatment. The diluted chlorine water (25 mg/l residual chlorine) was less effective than the diluted EO water for inactivation of C. jejuni. EO water was further evaluated for its effectiveness in reducing C. jejuni on chicken during washing. EO water treatment was equally effective as chlorinated water and both achieved reduction of C. jejuni by about 3 log10 CFU/g on chicken, whereas deionized water (control) treatment resulted in only 1 log10 CFU/g reduction. No viable cells of C. jejuni were recovered in EO and chlorinated water after washing treatment, whereas high populations of C. jejuni (4 log10 CFU/ml) were recovered in the wash solution after the control treatment. Our study demonstrated that EO water was very effective not only in reducing the populations of C. jejuni on chicken, but also could prevent cross-contamination of processing environments.  相似文献   

20.
酸性电解水对鸡白痢沙门氏菌杀灭效果的研究   总被引:1,自引:0,他引:1  
家禽和禽产品中的沙门氏菌是引起人类沙门氏菌感染和食物中毒的主要潜在来源,沙门氏菌通常被认为是生产者和消费者所面临的最严重的致病菌之一.研究不同电解质种类和电解时间等参数条件下制得的酸性电解水对鸡白痢沙门氏菌的杀灭效果,确定了酸性电解水 pH 值和有效氯浓度对杀菌效果的影响.结果表明,酸性电解水对鸡白痢沙门氏菌具有较强的杀灭效果,当酸性电解水pH值小于3或有效氯浓度超过1 mg/kg 时可以100%杀灭鸡白痢沙门氏菌,且 NaCl、KCl 溶液制得的酸性电解水的杀菌效果优于 CaCl2、MgCl2溶液制得的酸性电解水.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号