首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In a comprehensive two-dimensional gas chromatograph, a thermal modulator serially couples two columns containing dissimilar stationary phases. The secondary column generates a series of high-speed secondary chromatograms from the sample stream formed by the chromatogram eluting from the primary column. This series of secondary chromatograms forms a two-dimensional gas chromatogram with peaks dispersed over a retention plane rather than along a line. The method is comprehensive because the entire primary column chromatogram is transmitted through the secondary column with fidelity. One might expect that a two-dimensional separation in which both dimensions are basically the same technique, gas chromatography, would be inefficient because the two dimensions would behave similarly, generating peaks whose retentions correlate across dimensions. Applying a temperature program to the two columns, however, can tune the separation to eliminate this inefficiency. The temperature program reduces the retentive power of the secondary column as a function of progress of the primary chromatogram such that the retention mechanism of the primary column is eliminated from the second dimension. Retention of a substance in the second dimension is then determined by the difference in its interaction with the two stationary phases. Retention times in the second dimension then fall within a fixed range, and the whole retention plane is accessible. In a properly tuned comprehensive two-dimensional chromatogram, retention times in the two dimensions are independent of each other, and the two-dimensional chromatogram is orthogonal. Orthogonality is important for two reasons. First, an orthogonal separation efficiently uses the separation space and so has either greater speed or peak capacity than nonorthogonal separations. Second, retention in the two dimensions of an orthogonal chromatogram is determined by two different and independent mechanisms and so provides two independent measures of molecular properties.  相似文献   

2.
A method producing simultaneously three retention indexes for compounds has been developed for comprehensive two-dimensional gas chromatography by using a dual secondary column approach (GC x 2GC). For this purpose, the primary flow of the first dimension column was equally diverted into two secondary microbore columns of identical geometry by means of a three-way flow splitter positioned after the longitudinally modulated cryogenic system. This configuration produced a pair of comprehensive two-dimensional chromatograms and generated retention data on three different stationary phases in a single run. First dimension retention indexes were determined on a polar SolGel-Wax column under linear programmed-temperature conditions according to the van den Dool approach using primary alcohol homologues as the reference scale. Calculation of pseudoisothermal retention indexes in both second dimensions was performed on low-polarity 5% phenyl equivalent polysilphenylene/siloxane (BPX5) and 14% cyanopropylphenyl/86% dimethylpolysiloxane (BP10) columns. To construct a retention correlation map in the second dimension separation space upon which KovAts indexes can be derived, two methods exploiting "isovolatility" relationships of alkanes were developed. The first involved 15 sequential headspace samplings of selected n-alkanes by solid-phase microextraction (SPME), with each sampling followed by their injection into the GC at predetermined times during the chromatographic run. The second method extended the second dimension retention map and consisted of repetitive introduction of SPME-sampled alkane mixtures at various isothermal conditions incremented over the temperature program range. Calculated second dimension retention indexes were compared with experimental values obtained in conventional one-dimensional GC. A case study mixture including 24 suspected allergens (i.e., fragrance ingredients) was used to demonstrate the feasibility and potential of retention index information in comprehensive 2D-GC.  相似文献   

3.
A comprehensive two-dimensional HPLC system has been developed. It is based on the use of a microbore silica column operated in normal-phase (adsorption) mode (NP) in the first dimension and a monolithic type C18 column operated in reversed-phase (RP) mode in the second dimension. The interface was a 10-port, 2-position valve equipped with two storage loops. The first column was operated at a flow rate of 20 microL/min in isocratic mode, while the monolithic column flow rate was 4 mL/min and was operated in gradient mode. The sample loops had a volume of 20 microL each, and the analysis time in the second dimension was 1 min. In this way, every fraction from the first dimension was transferred on-line to the second dimension switching the automated valve every minute. A photodiode array detector has been used after the secondary column. The use of normal- and reversed-phase mode in the two dimensions can be helpful in the separation of complex mixtures of a natural origin that contain uncharged molecules of comparable dimension, different in polarity and hydrophobicity. The use of a microbore column in the first dimension permits the injection of a small volume in the secondary column, making the transfer of incompatible solvents from the first to the second dimension possible. Since the mobile phase in the NP separation is always stronger than the mobile phase at the head of the secondary column operated in RP mode, the initial eluent strength is important in order to obtain an effective focusing of the sample. The use of a monolithic type column in the second dimension permits the performance of very fast analysis operating at higher flow rates without loss of resolution, due to a higher permeability and increased mass-transfer properties in comparison to conventional particulate columns. Due to the brief reconditioning time necessary for monolithic columns, repetitive gradients can be carried out, extending the field of application to mixtures that contain components with different polarities. The utility of the system has been demonstrated in the analysis of the oxygen heterocyclic fraction of cold-pressed lemon oil, made up of coumarins and psoralens. These components may contain hydroxyl, methoxyl, isopentenyl, isopentenyloxyl, and geranyloxyl groups and oxygen-containing modification of the terpenoid side-chain groups, such as epoxides or vicinal diol groups. The relative location of the components in the 2D plane varied in relation to their chemical structure and allowed positive peak identification. The UV spectra recorded with the photodiode array detector supplied additional information that was used for the characterization of the studied sample.  相似文献   

4.
Mao Y  Carr PW 《Analytical chemistry》2001,73(18):4478-4485
The separation of basic pharmaceuticals is usually performed on C8 or C18 bonded silica supports. Silanolphilic interactions between basic analytes and surface silanol groups often lead to tailed peaks, poor efficiency, and irreproducible retention times. To solve these problems, many new types of silica-, zirconia-, and polymer-based columns, which provide unique selectivities, improved stability at high pH, or both, have been developed for the analysis of basic compounds. The essence of method development for the chromatographic analysis of basic compounds is to choose a system in which the band spacing can be varied dramatically, quickly, and conveniently while minimizing the tailing due to silanolphilic interactions. The thermally tuned tandem column (T3C) approach has been shown to provide an effective way to adjust stationary-phase selectivity for nonionic compounds. In this study, a tandem combination of an octadecylsilane (ODS) and a polybutadiene-coated zirconia (PBD-ZrO2) phase was used to separate nine antihistamines. Selectivity is tuned by independently adjusting the isothermal temperatures of the two columns. We found dramatic differences in the retention factors, elution sequences, and band spacing for the above set of basic drugs on the two types of columns. The T3C model has been used successfully to locate the optimal temperatures based on only four exploratory runs. The nine antihistamines were baseline separated on the tandem column combination even though they could not be separated on the individual phases. The effect of the buffer concentration on retention of the basic antihistamines was also studied. We conclude that cation-exchange interactions predominate on the PBD-ZrO2 phase, while reversed-phase interactions are more important on the ODS phase. Interestingly, an increase in column temperature causes a significant increase in the retention on the ODS column and a decrease of retention on the PBD-ZrO2 column. This can be explained by the change in the analyte's degree of ionization with temperature. The T3C combination of silica- and zirconia-based RPLC columns is demonstrated to be a powerful approach for the separation of this mixture of basic analytes.  相似文献   

5.
A novel fritless capillary column for capillary electrochromatography (CEC) has been developed. The ODS microspheres were packed into a capillary and were then immobilized within an organic polymer prepared in situ through a photopolymerization process. The entrapment conditions were investigated to minimize the effect of the polymer matrix on the chromatographic properties of the packing material. The organic polymer matrix in the microsphere-packed column functions to link microspheres at specific sphere-sphere and sphere-capillary contact points. CEC separations of a PAH test mixture using entrapped columns with different UV illumination times were compared in terms of retention factor and separation efficiency. The optimized entrapped column demonstrated better chromatographic performance than similarly packed columns with conventional inlet and outlet frits. The electrochromatographic separations of hormones and peptides were also demonstrated on entrapped ODS columns.  相似文献   

6.
A series-coupled (tandem) ensemble of two capillary GC columns using different stationary phases and a pneumatically actuated low-volume valve connecting the column junction point to an atmospheric-pressure vent line is used to adjust the ensemble separation of selected pairs of target compounds. The valve is normally closed, and the pressure at the column junction point assumes the value that would occur in the absence of any other connections. The valve can be opened for brief periods of time, thus producing pulses of atmospheric pressure at the column junction point. If a component pair is separated by the first column but coelutes from the column ensemble, the ensemble separation can be increased if a pulse occurs when one of the components has migrated across the column junction but the second component is still on the first column. All of the mixture components that are on the same column during the time that the valve is open (pulse duration) will be shifted to either larger or smaller retention times, but the pattern of peaks (elution order) for these components from the column ensemble will be relatively unaffected by the pressure pulse. Multiple pulses can be used to enhance the separation of different component pairs, which sequentially reach the column junction point. Performance of the valve-operated system is described. Time-of-flight mass spectrometry with time-array detection is used to examine the effects of pulse duration on the separation achieved for different component pairs.  相似文献   

7.
A novel approach to comprehensive two-dimensional gas chromatography (GCxGC) separations is presented, which operates in a new region of the "GCxGC optimization pyramid". The technique relies on the use of short primary columns to decrease elution temperatures (Te) of analytes from the primary column, with a Te reduction of up to 50 degrees C illustrated. This in turn has implications that will expand the areas where GCxGC can be used, as decreased elution temperatures will allow GCxGC to be applied to mixtures of less volatile compounds or permit the use of less thermally stable stationary phases in the column ensemble. As well, it will allow GCxGC to be applied to thermally labile compounds through a reduction in elution temperature. With short primary columns, resolution and efficiency in the first dimension is sacrificed, but speed is gained; however, the second column in GCxGC provides additional resolution and separation of compounds of differing chemical properties. Thus, it is possible to recover some of the analytical separation power of the system to provide resolution of target analytes from sample impurities. As an example, a case study using short primary columns for the separation of natural pyrethrins, which degrade above 200 degrees C, is described. Even with the sacrifices of overall separation power that are made, there is still sufficient resolution available to separate the six natural pyrethrins from each other and the complex chrysanthemum extract matrix. The use of cold-on-column injection, a short primary column, and a high carrier gas flow rate allow the pyrethrins to be eluted below 200 degrees C, with separation in 17 min and complete resolution from sample matrix.  相似文献   

8.
A comprehensive two-dimensional (2-D) liquid chromatographic separation system is presented. The system uses a microbore cation exchange column, operated under gradient conditions, as the first dimension separation. Effluent from this first column alternately fills one of two loops on a computer-controlled eight-port valve. A second pump then forces loop material onto a second column, a size exclusion column. UV detection is used, and the system is applied to the separation of protein standards and serum proteins. The 2-D system has a higher resolving power and peak capacity than either of the two columns used alone. The entire first column effluent is analyzed on the second column in virtually the same time it takes to complete the first column separation, without the use of stopped flow methods. The entire system is automated and operated under computer control. Three-dimensional (3-D) data representation provides a means of viewing peak profiles in either separation dimension and contour mapping of the 3-D data provides a more reliable means of peak identification from run to run than that provided by single-column elution times.  相似文献   

9.
Mao Y  Carr PW 《Analytical chemistry》2001,73(8):1821-1830
There are many more choices of column type than of eluent type for method development in reversed-phase liquid chromatography. It is common to switch between different column types or between the same type from different suppliers to achieve the desired separations. The key difficulty in modulating band spacing by adjusting the column type is that it is a discontinuous, "hit or miss" proposition. The thermally tuned tandem column (T3C) concept effectively solves this problem by connecting two columns in series and independently controlling the two column temperatures. The columns are chosen to have distinctively different chromatographic selectivities (band spacing), so that the unresolved peaks on one column are separated by the other. The optimized separation in the T3C is achieved by simultaneously tuning the two column temperatures. In this study, we used the T3C combination of a carbon and a conventional bonded phase for the separation of barbiturates and phenylthiohydantoin amino acids (PTH-amino acids). Good peak shapes and comparable retention times were observed on the two phases at room temperature. The selectivities on the two phases are quite different. Baseline separations were easily achieved with the T3C set although neither column could individually resolve all the peaks. We further compared the separation of barbiturates optimized by the T3C approach with that optimized by adjusting the mobile phase. We found that T3C gave a better separation. We believe that the T3C combination of a carbon phase and a bonded conventional reversed-phase material provides a powerful and general method to optimize the separation of various mixtures.  相似文献   

10.
Mao Y  Carr PW 《Analytical chemistry》2000,72(13):2788-2796
Separations of several families of environmental toxicants were optimized by means of the thermally tuned tandem column (T3C) concept. We use a tandem combination of an octadecylsilane (ODS) and a carbon-coated zirconia (C-ZrO2) column; and tune the selectivity by independently adjusting the isothermal temperatures of the two columns. This results in the change in the contribution that each column makes to the overall retention and selectivity. The separation was optimized by locating the optimum pair of column temperatures which give the best separation of the critical solute pair. For both triazine herbicides and carbamate pesticides samples, dramatically different selectivities and different critical pairs were observed for the two types of phases. Although neither individual phase gave adequate separation, the T3C approach provided baseline separations using only four preliminary trial separations. We also showed that, for the triazine samples, the T3C approach gave a better separation than did conventional mobile phase optimization with an ODS column. The combination of superior selectivity of T3C and high flow rate allows the baseline separation of complex mixtures in just a few minutes.  相似文献   

11.
A new instrumental approach for collection of retention index data in the first (1D) and second (2D) dimensions of a comprehensive two-dimensional (2D) gas chromatography (GCxGC) experiment has been developed. First-dimension indexes were determined under conventional linear programmed temperature conditions (Van den Dool indexes). To remove the effect that the short secondary column imposes on derived 1D indexes, as well as to avoid handling of pulsed GCxGC peaks, the proposed approach uses a flow splitter to divert part of the primary column flow to a supplementary detector to simultaneously generate a conventional 1D chromatogram, along with the GCxGC chromatogram. The critical 2D indexes (KovAts indexes) are based upon isovolatility curves of normal alkanes in 2D space, providing a reference scale against which to correlate each individual target peak throughout the entire GCxGC run. This requires the alkanes to bracket the analytes in order to allow retention interpolation. Exponential curves produced in the 2D separation space require a novel approach for delivery of alkane standards into the 2D column by using careful solvent-free solid-phase microextraction (SPME) sampling. Sequential introduction of alkane mixtures during GCxGC runs was performed by thermal desorption in a second injector which was directly coupled through a short transfer line to the entrance of the secondary column, just prior to the modulator so that they do not have to travel through the 1D column. Thus, each alkane mixture injection was quantitatively focused by the cryogenic trap, then launched at predetermined times onto the 2D column. The system permitted construction of an alkane retention map upon which bidimensional indexes of a 25-perfume ingredient mixture could be derived. Comparison of results with indexes determined in temperature-variable one-dimensional (1D) GC showed good correlation. Plotting of the separation power in the second dimension was possible by mapping Trennzahl values throughout the 2D space. The methodology was applied to the separation of a standard mixture composed of 25 analytes (very diverse in polarity and structure) suspected to be allergens in perfume samples. The method will allow straightforward determination of temperature-variable retention indexes of target analytes.  相似文献   

12.
A new software package, Virtual Column 2, is described for the simulation and optimization of the separation of inorganic anions by ion chromatography (IC). The software uses a limited amount of experimental retention data acquired according to a correct experimental design to predict retention times for analytes over a designated search area of eluent compositions. The experimental retention data are used to solve a new retention model, called the linear solvent strength model, empirical approach (LSSM-EA), which then enables prediction of retention times for all eluent compositions in the search area. The theoretical development of LSSM-EA and the processes used for solving the equations are discussed. Virtual Column 2 can be used for eluents containing one or two competing ions, and the software contains retention databases for up to 33 analytes on the Dionex AS9A-HC, AS4A-SC, and AS14A analytical columns with carbonate-bicarbonate eluents and the Dionex AS10, AS15, and AS16 analytical columns with hydroxide eluents (results for the AS10 and AS15 columns are not discussed in the present study). Virtual Column 2 has been evaluated extensively and is shown to give predicted retention times that in most cases agree with experimentally determined data to within 5%. The software has uses in practical IC method development, education and training in IC, and refinement of existing IC methodology. A free version of this program is available by download at www.virtualcolumn.com.  相似文献   

13.
With comprehensive two-dimensional supercritical fluid and fast, independent temperature-programmed gas chromatography (SFCxGC), a polar column was used in the first dimension to achieve group-type analysis. The eluent of this separation was repetitively sampled and transferred to a fast, resistively heated gas chromatograph to obtain the boiling point distribution over the entire polarity separation. The SFC was operated isothermally with stopped flow to provide a sufficient time span for the GC analysis. The GC analysis had a typical cycle time of 1 min for the system demonstrated here. During this time, the GC column was independently heated at a rate of 450 degrees C/min to 250 degrees C and actively cooled again to -50 degrees C before the next GC injection took place. The analysis of petrochemical samples is presented to illustrate the technique.  相似文献   

14.
The study presents the efficiency of sewage sludge sample clean-up with the application of SPE columns with various types of adsorbents. Six columns were tested: C8-octyl, C18 PolarPlus, C18-octadecyl, silicagel (SG), phenyl, cyano. The highest efficiency of recovery was observed for C18-octadecyl. Then, using C18, the method was optimised by changing the following parameters: eluent type and volume, column drying and effect of washing of cartridge.  相似文献   

15.
Two-dimensional HPLC was applied for the first time to the analysis of complex surfactant mixtures. In the first dimension, ion chromatographic-type separations were performed on a diol column eluted by an acetonitrile-water (0.1% trifluoroacetic acid) gradient. Using this new technique, cationic and amphoteric surfactants were not retained at all, nonionic surfactants exhibited a weak and essentially unspecific retention, and anionic surfactants were retained mainly according to their functional group. Rather than detecting the analytes immediately after this first separation, successive fractions were automatically and quantitatively transferred to parallel C2 (dimethyl) and C4 (butyl) reversed-phase columns using an innovative setup. The second dimension of the separation then took place, by which the analytes were separated according to their hydrophobicity. Surfactants from all four classes, cationic, amphoteric, nonionic, and anionic, were separated simultaneously in single 54-min two-dimensional HPLC runs. The suitability of the method for quantitative measurements was demonstrated.  相似文献   

16.
In this paper, we compare a narrow-bore column (2.1-mm i.d.) to a conventional-bore column (4.6 mm i.d.) at elevated temperatures under conditions where thermal mismatch broadening is serious and show that narrow-bore columns offer significant advantages in terms of efficiency and peak shape at higher linear velocities. We conclude that the so-called thermal mismatch broadening effect is largely due to a radial retention factor gradient and not a radial viscosity gradient. The lower volumetric flow rates inherent with the use of narrower columns lead to lower linear velocity in the heater tubing and longer eluent residence times in the heater. Thus, with the same heater tubing at the same column linear velocity, narrow-bore columns give better thermal equilibration between the eluent and the column compared to wider bore columns. This means that high-temperature, ultrafast liquid chromatography no longer requires excessively long preheater tubing to thermally equilibrate the eluent to the column temperature. Consequently, the use of narrow-bore columns at high-temperature improves analysis speed and efficiency over wider bore columns. We also discuss the advantages of using liquid heat-transfer media as compared to air as the heat-transfer media. We show that an air bath ought not be used to heat the mobile phase because at high temperature (>80 degrees C) and high column linear velocity (> 1.5 cm/s) the length of tubing needed to heat the mobile phase to column temperature is prohibitively long. Using accurate, empirical heat-transfer correlations, we estimated the length of tubing needed to heat the eluent as a function of the column linear velocity for both air and liquid heat-transfer media.  相似文献   

17.
Cai H  Stearns SD 《Analytical chemistry》2004,76(20):6064-6076
A partial modulation method by using a pulsed-flow modulator for comprehensive two-dimensional gas chromatography is proposed. The method is based on the fact that when a pulsed flow of inert gas is introduced into the conjunction between a primary and a secondary column, the concentration of analyte is disturbed, and a plug of higher or lower concentration is created. The plug, which forms a spike signal coupled to the primary GC signal, is then separated in a secondary column, creating a new dimension of GC information. The modulation is partial because only a fraction of the primary signal is modulated and converted into the secondary signal; the remaining primary signal stays unchanged. Therefore, this method yields a comprehensive two-dimensional chromatogram and a primary one-dimensional chromatogram in a single GC run. In this study, the modulation mode, modulation index, and modulation percentage are discussed and the reproducibility of peak areas and retention time are investigated. With a 5.8% modulation percentage and a primary peak half-width 1.7 times wider than the modulation time, the standard deviation for the peak areas are 0.15% for the primary and 0.78% for the secondary chromatograms. Chromatograms of laboratory-mixed hydrocarbons and of high-temperature fuel oil no. 6 standard are demonstrated.  相似文献   

18.
A computer-driven pressure controller is used to deliver pressure pulses to the junction point of two series-coupled columns using different stationary-phase chemistries. The column ensemble consists of a trifluoropropylmethyl polysiloxane column followed by a dimethyl polysiloxane column. Each pressure pulse causes a differential change in the carrier gas velocities in the two columns, which lasts for the duration of the pulse. A pressure pulse is used to selectively increase the separation of a component pair that is separated by the first column but coelutes from the series-coupled ensemble. If both components are on the same column when the pulse is applied, a small change in the ensemble separation occurs. If one component of the pair is on the first column and the other component is on the second column, a pressure pulse can result in a much larger change in the ensemble separation for the component pair. A model with a spreadsheet algorithm is used to predict the effects of a pressure pulse on the trajectories of component bands on the column ensemble. The effect of the initiation time of a pressure pulse is investigated for a two-component mixture that coelutes from the column ensemble. For the case where the entire pressure pulse occurs when one of the components is on the first column and the other component is on the second column, the peak separation from the ensemble increases nearly linearly with the product of the pressure pulse amplitude and the pulse duration. Peak shape artifacts are observed if the pressure pulse occurs when a solute band is migrating across the column junction point.  相似文献   

19.
A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fractionation step was followed by anion or cation exchange chromatography as the first dimension. The separation mechanism in the subsequent second dimension employed hydrophobic interactions using short reversed-phase (RP) columns. A new column-switching technique, including four parallel reversed-phase columns, was employed in the second dimension for on-line fractionation and separation. Gradient elution and UV detection of two columns were performed simultaneously while loading the third and regenerating the fourth column. The total integrated workstation was operated in an unattended mode. Selected peaks were collected and analyzed off-line by MALDI-TOF mass spectrometry. The system was applied to protein mapping of biological samples of human hemofiltrate as well as of cell lysates originating from a human fetal fibroblast cell line, demonstrating it to be a viable alternative to 2D gel electrophoresis for mapping peptides and small proteins.  相似文献   

20.
A new method is described that allows fast target analysis in multidimensional gas chromatography by using a microswitching valve between two GC columns, with cryogenic trapping and rapid re-injection of trapped solutes in the second dimension. The essence of the procedure is that heart-cut fractions from the first column (1D) can be selectively transferred to column 2 (2D), where a moveable cryogenic trap first focuses the transferred solute(s) at the head of the second column and then permits their facile rapid analysis on 2D. Since 2D is a short narrow-bore column, which exhibits very fast analysis (on the order of a few seconds elution), peak responses (heights) are significantly enhanced (by up to 40-fold). Additionally, by using a 2D phase of a selectivity different from that used for 1D, it is possible to also separate components that are not resolved on the first column and to increase the resolution for other compounds. The heart-cut valve isolates the section(s) of solutes of interest from the first column separation, and this provides a considerable simplification to the chromatogram-in addition to the separation and sensitivity advantages. By using this method, multidimensional gas chromatography with multiple heart-cuts can be completed within the same time as the primary column separation. Since the described method permits non-heart-cut fractions to be transferred to a monitor detector, normal detection of these fractions is still permitted. By modulation of the cryotrap, it is also possible to achieve comprehensive two-dimensional gas chromatography for the heart-cut fractions; however, only those compounds passed to the second, separation column, which passes through the cryotrap, will be subjected to GC x GC analysis. The technique and the various modes of operation are described in this paper.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号