同杆双回线非全相运行的精确计算与单相重合闸研究   总被引:2,自引:0,他引:2  
本文采用精确分布参数数学模型计算和分析了无并联电抗器的500KV同杆双回线和一侧带并联电抗器的500KV同杆双回线在永久性故障和瞬时性故障时故障线路电压与非故障线路电压之间的相位关系.提出采用故障相电压幅值大小,故障相电压与非故障线路电压之间的相位比较,以及故障相电压谐波大小的综合判据,以区分永久性故障与瞬时性故障,实现有选择的单相自动重合闸.防止重合于故障线路造成对系统和设备的冲击.  相似文献   

2.
为实现特高压输电线路单相重合前无故障判别,分析了不同情况下带并联电抗器的特高压线路单相故障时断开相的电压和并联电抗器电流的幅值及频率特征,提出了利用Prony算法提取断开相电压和并联电抗器电流的主要低频分量频率及幅值信息作为组合判据。结果表明:故障未消失时,断开相电压和电抗器电流无自振低频分量,仅有工频周期分量;而故障消失后,断开相电压和并联电抗器电流存在工频和自振低频2种周期分量。电抗器补偿度对断开相电压及电抗器电流的幅值影响较大,但自振低频分量频率由线路固有参数决定,因此利用电压量和电流量作为综合判据避免了以单一电气量幅值判别可靠性低的不足。通过大量的ATP仿真验证了该判据能够实现重合前无故障的可靠识别,且判据基本不受系统运行状态及故障条件的影响,有利于提高带并联电抗器线路单相重合闸的重合成功率。  相似文献   

3.
基于改进型相关法的单相自适应重合闸新判据   总被引:9,自引:1,他引:9  
分析了超、特高压输电线路发生单相瞬时性及永久性接地故障时断开相电压的形成机理,指出瞬时性单相接地故障时断开相计算电压与两健全相电压和沿线变化规律的相似程度远大于永久性接地故障时的相似程度,并在此基础上,提出利用改进型相关法的故障性质识别新判据。该判据综合考虑了断开相计算电压与两健全相电压和的幅值与相位的相似性,使瞬时性故障时的相关系数大于永久性故障时的相关系数。该判据实现简单,高阻接地时仍具有较高灵敏度,且受线路长度、负荷电流及故障距离的影响很小,适用 于不带并联电抗器的超、特高压输电线路。大量仿真实验验证了所得结论的正确性。  相似文献   

4.
研究了带并联电抗器的超高压输电线路发生单相接地故障时跳开相电压的自由振荡分量频率的影响因素,分析了带并联电抗器的超高压输电线路发生单相接地故障时跳开相电压的相位特征,揭示了恢复电压相位周期性波动的原因,并考虑了傅氏算法处理含非基频量信号时的误差对跳开相电压相位计算的影响。引入健全相电压相量和作为极化电压,以极化电压为基准区分发生瞬时性故障与永久性故障时的跳开相电压相位,提出了识别永久性故障的跳开相电压相位波动判据。EMTP仿真结果表明,该判据计算简单,判定准确,且不受过渡电阻影响,可有效适用于带并联电抗器的输电线路单相故障性质的识别。  相似文献   

5.
超高压输电线路单相自适应重合闸相位判据的研究   总被引:1,自引:0,他引:1  
分析了未装设并联电抗器的超高压输电线路断开相故障点电压在瞬时性与永久性故障情况下的幅值特征及其与该点健全相电压之间的相位关系,指出瞬时性故障点电压与该点两健全相电压和同相位,而永久性故障时该点电压与该点两健全相电压和的相位差随过渡电阻及线路长度的减小而接近90度,据此提出了判断故障性质的相位判据,并针对金属性故障及线路出口处的低阻故障情况提出了补充判据,该判据可准确地判断故障性质且对于测距误差与线路参数估计误差具有良好的自适应性,大量仿真实验验证了所得结论。  相似文献   

6.
针对带并联电抗器的同杆双回线线路,在复频域上对故障相端电压进行详细分析,提出利用故障相β模电压进行故障性质判断的方法,其中β模电压为不同回线故障相电压平均值之差。以IABIIBC跨线故障为例进行仿真分析,综合得出利用故障相β模电压进行判断的结论,并给出了不同故障类型下的β模电压求解通式。瞬时性跨线故障下β模电压中既存在工频分量又存在自由频率分量;而永久性跨线故障下β模电压中只存在工频分量。通过利用最小二乘法提取其中自由频率分量幅值可以准确判断出故障性质,原理简单,灵敏度高。大量ATP仿真实验表明,该方法能够识别不同跨线故障类型的故障性质,可以应用于带并联电抗器同杆双回线的自适应重合闸。  相似文献   

7.
利用中性点电抗器实现高压输电线单相自适应重合闸   总被引:1,自引:1,他引:0  
对带并联电抗器和中性点电抗器的超高压输电线,为了避免重合于永久性故障,在单相重合闸之前合上中性点电抗器与地之间装设的接地开关S,根据断开相电压值可以有效地判别线路故障的性质和绝缘水平,防止重合于故障线路.通过设定被短接电抗的百分比或者经过阻尼电阻短接部分电抗可以控制断开相振荡电压水平,防止断开相过电压.ATP-EMTP暂态仿真结果表明:如果是瞬时性故障,只要两侧中性点电抗器开关S的动作时间差小于30 ms,或者后合一侧的中性点电抗器开关S在电压振荡幅值最低时刻附近合上,断开相电压值可以振荡到额定电压的水平,单相重合闸可以成功;反之,若断开相电压值保持在很低的水平,则必然是永久性故障.  相似文献   

8.
超高压输电线路发生瞬时性故障时,伴随着二次电弧拉伸故障相电压幅值逐渐上升;永久性故障时,故障相电压在断路器跳闸后幅值迅速下降并最终保持在一恒定值。为分析瞬时故障时电弧特性,利用ATP/EMTP建立一、二次电弧模型。根据故障相电压幅值变化趋势,计算故障相电压包络的差分在固定时间窗内的能量值,得出永久性故障与瞬时性故障时,能量值表现出明显的差异。因此提出以故障相电压包络的差分在连续时间窗内的能量值与首次时间窗内的能量比的均值作为故障性质识别的判据。大量仿真验证了该判据准确可靠,适用于带并联电抗器的超高压输电线路。  相似文献   

9.
带并联电抗器输电线路单相故障性质识别判据   总被引:2,自引:0,他引:2  
针对带并联电抗器超特高压输电线路,分析了瞬时性故障时低频分量频率基本不受系统阻抗及故障点位置变化的影响,在低频分量频率离线准确计算的前提下,提出采用最小二乘拟合方法快速检测断开相并联电抗器电流低频分量和工频分量幅值实现的单相故障性质识别新判据.瞬时性故障时,低频分量幅值接近或超过工频分量幅值;永久性故障时,低频分量幅值接近0.判别算法仅利用断开相并抗电流,原理简单可靠,且易于实现.大量ATP仿真验证表明,该判据正确有效,能快速实现单相故障性质判别,有望提高单相重合闸动作的成功率.  相似文献   

10.
针对带并联电抗器超特高压输电线路,分析了瞬时性故障时低频分量频率基本不受系统阻抗及故障点位置变化的影响,在低频分量频率离线准确计算的前提下,提出采用最小二乘拟合方法快速检测断开相并联电抗器电流低频分量和工频分量幅值实现的单相故障性质识别新判据。瞬时性故障时,低频分量幅值接近或超过工频分量幅值;永久性故障时,低频分量幅值接近0。判别算法仅利用断开相并抗电流,原理简单可靠,且易于实现。大量ATP仿真验证表明,该判据正确有效,能快速实现单相故障性质判别,有望提高单相重合闸动作的成功率。  相似文献   

11.
带并联电抗器输电线路永久性故障识别新方法   总被引:1,自引:0,他引:1  
针对带并联电抗器的超高压输电线路,提出一种单相自适应重合闸永久性故障识别的新方法。该方法以瞬时性故障为参考模型,求取并联电抗器故障相电流,采用该求取电流与并联电抗器故障相实际测量电流之差同中性点小电抗器电流幅值比来实现永久性故障的判别。发生瞬时性故障时,故障模型正确,差电流幅值比接近零;发生永久性故障时,故障模型不正确,差电流幅值比远大于零。ATP仿真结果表明,该方法能够准确区分瞬时性故障和永久性故障,判别原理有效,能够可靠地实现超高压输电线路的单相自适应重合闸。  相似文献   

12.
Single-phase adaptive reclosure (SPAR) schemes applied to transmission lines have been an effective method to improve the stability of power system. Attractive techniques have been proposed for SPAR schemes based on the tripped fault-phase voltage. But for transmission lines with shunt reactors, the voltage is so minor that the error of voltage transformer limits the applications of voltage-based SPAR schemes. To overcome this disadvantage, a new scheme using differential current between the calculated current based on transient fault model and the actual measured current from the fault phase of shunt reactor is proposed in this paper. The calculated current is obtained by using the transient fault model whether there is a transient or permanent fault. In the case of transient fault, the calculated current is close to the measured current due to the actual fault model being close to the calculated model. As for the permanent fault, the calculated current is quite different from the measured current. Therefore, the differential current of the fault phase can be employed to distinguish permanent fault from transient fault. At last, the Alternative Transients Program simulation results show that the developed algorithm can identify the permanent fault correctly and reliably, and is promised to be applied to SPAR for transmission lines with shunt reactors.   相似文献   

13.
针对一端和两端带并联电抗器的超高压同杆双回输电线路,分析故障相并联电抗器电压的测量值与实际计算值以及中性点小电抗电压特性,提出一种基于故障相并联电抗器电压的计算值与实际测量值之差同中性点小电抗器电压的幅值比来实现区分失压可恢复绝缘故障与失压不可恢复绝缘故障的判别原理。利用该方法可以区分失压可恢复绝缘故障与失压不可恢复绝缘故障,具有较高的灵敏度。利用EMTP对瞬时性故障与永久性故障时故障相并联电抗器的电压特性进行了大量的仿真,结果表明该方法能够有效地判别故障的性质,可靠地实现同杆双回输电线路自适应重合闸。  相似文献   

14.
带并联电抗器的线路单相自适应重合闸故障判别原理   总被引:3,自引:1,他引:2  
针对带并联电抗器的超高压输电线路,研究了故障后线路断开相并联电抗器与中性点小电抗上的电压特性,发现在永久性故障时,无论是金属性接地还是经过渡电阻接地,断开相并联电抗器上电压与中性点小电抗上电压的比值总是大于瞬时性故障时两者的电压比值。基于上述结论,提出了超高压带并联电抗器输电线路单相自适应重合闸故障的电压判别方法。理论分析和EMTP仿真表明,该判别方法简单、有效,能可靠实现超高压输电线路上的单相自适应重合闸。  相似文献   

15.
同杆双回线发生接地故障采用传统跳闸策略时可能会产生负序分量,传统自动重合闸方案在合闸前不判定故障性质,重合失败时将影响系统稳定性。针对该问题,提出了一种适用于带并抗的同杆双回线接地故障改进跳闸与分相自适应重合闸策略。首先,通过建立带并抗的同杆双回线各相之间的耦合模型并对其进行分析,提出了一种能够避免负序分量注入系统的改进跳闸策略。其次,分别对瞬时性故障和永久性故障情况下的故障相并联电抗器电流特征分析,提出了基于故障相并联电抗器微分栅电流的故障性质判据。最后,结合改进跳闸策略和故障性质判据,形成了适用于带并抗的同杆双回线接地故障分相自适应重合闸策略。PSCAD/EMTDC仿真验证了所提改进跳闸与分相自适应重合闸策略能够避免负序分量注入系统,以及在不同接地故障类型、故障位置和过渡电阻情况下都能保证输电线路重合成功率。  相似文献   

16.
在带并联电抗器超高压输电线路中,当发生单相接地故障,瞬时性故障时断开恢复电压中存在由于储能元件初始储能引起的自由分量,该自由分量幅值接近或高于其稳态基波分量的幅值,频率低于且接近于工频,因此断开相恢复电压呈拍频性质;而永久性故障时故障点始终存在,线路上各储能元件所储存的能量快速衰减,断开相电压中没有低频振荡分量而仅含有基波量。提出一种判别其两种波形的不同以区别故障性质的方法。该方法原理较简单,具有一定的工程应用前景。  相似文献   

17.
提出了一种基于超高压输电线路并联电抗器故障相电流特性的单相自动重合闸永久故障识别方法。输电线路发生单相故障两端跳闸后,并联电抗器故障相电流流经的回路在瞬时性故障和永久性故障下明显不同,因此利用流过并联电抗器故障相的电流与中性点小电抗器的电流的幅值比就能判别瞬时性和永久性故障,有效地解决了现有自适应重合闸判据在带并联电抗器超高压输电线路上应用难的问题。EMTP 仿真结果和试验系统录波数据都证明该识别方法能准确地区分永久和瞬时故障,有很高的可靠性,可直接应用于目前微机保护装置。  相似文献   

18.
针对带并联电抗器的超高压电缆-架空混合线路,分析了两相或三相不同性质故障时故障相的残余电压特性,提出了基于差模电压频率测量的相间故障性质识别新判据。混合线路发生故障且两侧断路器跳开后,利用扩展Prony算法快速获取差模电压频率。发生瞬时性故障时,差模电压频率略低于工频;发生永久性故障时,差模电压频率接近于0。基于上述特征可进行瞬时性故障与永久性故障的有效识别,该方法原理简单,且易于实现。大量的EMTDC仿真验证表明,该方法能够有效可靠地实现超高压电缆-架空混合线路的永久性故障与瞬时性故障的识别,且不受过渡电阻、故障位置及电力电缆所占线路全长比例的影响。  相似文献   

19.
带并联电抗器的超高压输电线路单相自适应重合闸新算法   总被引:4,自引:1,他引:3  
带有并联电抗器的超高压输电线路发生单相故障两端跳闸后,断开相恢复电压的组成成分在瞬时性故障时比永久性故障时多了一项自由分量,因此通过对断开相恢复电压在一个工频周期内进行积分就可以区分两种不同性质的故障.该判据原理简单,灵敏度高,实际操作方便,判断时间快,有效地解决了现有判据判断时间长的问题.大量的仿真实验验证了所得结论的正确性.  相似文献   