首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new sensitive assay has been developed for the quantitative measurement of BN50727 at the picomole level in human plasma and urine. The drug and the internal standard (BN50788) were measured by combined liquid chromatography/negative ion chemical ionization mass spectrometry with methane as the reagent gas. A simple solid-liquid extraction procedure was used to isolate BN50727 from the complex biological matrices. The mass spectrometer was tuned to monitor the intense and stable ion at m/z 333 which was generated in the ion source by a dissociative capture process. This assay was performed with 1 ml of plasma or 0.1 ml of urine and the quantification limit of the method was statistically calculated as 1 ng ml-1. The very low relative standard deviations and mean percentages of error calculated during the different within-day or between-day repeatability assays have clearly demonstrated the ruggedness of the technique for the routine determination of BN50727 in biological fluids. Some preliminary results on the pharmacokinetics of the drug are presented to illustrate the applicability of this powerful liquid chromatographic/mass spectrometric method.  相似文献   

2.
A high-performance liquid chromatographic method was developed for the determination of a new proton pump inhibitor, YH1885 (I), in human plasma and urine, and rat blood and tissue homogenate using fenticonazole as an internal standard. The sample preparation was simple: a 2.5 volume of acetonitrile was added to the biological sample to deproteinize it. A 50-microliter aliquot of the supernatant was injected onto a C8 reversed-phase column. The mobile phase employed was methanol-0.005 M tetrabutylammonium dihydrogenphosphate (77:23, v/v), and it was run at a flow-rate of 1.0 ml/min. The column effluent was monitored using an ultraviolet detector at 270 nm. The retention times for I and the internal standard were 9.0 and 10.3 min, respectively. The detection limits for I in human plasma and urine, and in rat tissue homogenate (including blood) were 50, 100 and 100 ng/ml, respectively. The coefficients of variation of the assay (within- day and between-day) were generally low (below 8.84%) for human plasma and urine, and for rat tissue homogenate. No interferences from endogenous substances were found.  相似文献   

3.
This paper describes a high-performance liquid chromatographic method with ultraviolet absorbance detection at 304 nm for the determination of 6-chloro-5-(1-naphthyloxy)-2-methylthio benzimidazole (alphaBIOF10) -- a new fasciolicide agent -- and its sulphoxide (SOalphaBIOF10), in plasma and urine. It requires 2 ml of biological fluid, an extraction using Sep-Pak cartridges, and methanol for drug elution. Analysis is performed on a microBondapak C18 (10 microm) column, using methanol-acetonitrile-water (40:30:30, v/v) as the mobile phase. Results showed that the assay is sensitive: 7.2 ng/ml for alphaBIOF10 and SOalphaBIOF10 in plasma and 3.6 ng/ml for both compounds in urine. The response was linear between 0.195 and 12.5 microg/ml. Maximum intra-day coefficient of variation was 5.3%. Recovery obtained was 97.8% for both alphaBIOF10 and SOalphaBIOF10. In urine, recovery was 99.6% and 93.1% for alphaBIOF10 and SOalphaBIOF10 respectively. The method was used to perform a preliminary pharmacokinetic study in two sheep and was found to be satisfactory.  相似文献   

4.
A sensitive assay for the determination of N,N',N"-triethylenthiophosphoramide (thioTEPA) in microvolumes of human plasma and urine has been developed. ThioTEPA was analysed using gas chromatography with selective nitrogen-phosphorus detection, after extraction with ethyl acetate from the biological matrix. Diphenylamine is the internal standard. The limit of quantitation was 0.1 ng/ml, using only 100 microl of sample; recoveries ranged between 85 and 100% and both accuracy and precision were less than 10%. Using a flame ionisation nitrogen-phosphorus detector, the assay was not linear over the concentration range of 2-1000 ng/ml for plasma and 10-1000 ng/ml for urine. Linearity was accomplished in the range of 1-1000 ng/ml for plasma and urine when a thermionic nitrogen/phosphorous detector was used. The stability of thioTEPA in plasma proved to be satisfactory over a period of 3 months, when kept at -20 degrees C, whereas it was stable in urine for at least 1 month at -80 degrees C. ThioTEPA plasma concentrations of two patients treated with thioTEPA are presented demonstrating the applicability of the assay.  相似文献   

5.
A highly sensitive and specific assay has been developed for the determination of MDL 73745 [2,2,2-trifluoro-1-(3-trimethylsilyl-phenyl) ethanone] (I) and the internal standard (MDL 74398) at the nanomolar level in dog plasma and urine by gas chromatography/mass spectrometry. After a single-step extraction process, an aliquot was directly injected onto the gas chromatograph column. The mass spectrometer was run in the negative ion chemical ionization mode with ammonia as reagent gas, and was set to monitor the abundant M-. ion at m/z 246 of both compounds. The method yielded a linear response over the concentration range 0.1-10 pmol 100 microliters -1 plasma or urine. Within-day reproducibility at a concentration of 0.25, 1 and 5 pmol 100 microliters -1 plasma was 8.6%, 1.0% and 1.0%, respectively. The method was applied to the determination of I in plasma and urine after administration of 1 mg kg-1 i.v. and 10 mg kg-1 p.o. to dogs.  相似文献   

6.
A high-performance liquid chromatographic method was developed for the determination of a new antiulcer agent, YJA-20379-2, in human plasma and urine. The sample preparation was simple: 2.5-volume of acetonitrile was added to the biological sample to deproteinize. A 50-microliter aliquot of the supernatant was injected onto a C18 reversed-phase column. The mobile phase employed was methanol-0.1M S?rensen phosphate buffer of pH 7.0-H2O (75:2:25, v/v/v), and was run at a flow-rate of 1.0 ml/min. The column effluent was monitored by ultraviolet detector at 295 nm. The retention time for YJA-20379-2 was approximately 7.0 min. The detection limits for YJA-20379-2 in human plasma and urine were both 100 ng/ml. The coefficients of variation of the assay (within-day and between-day) were generally low (below 9.16%) for both the human plasma and urine. No interference from endogenous substances was found.  相似文献   

7.
The gadobenate ion is an intravascular paramagnetic contrast agent for magnetic resonance imaging. An HPLC method for assaying gadobenate ion in plasma, urine, faeces, bile and tissue samples is described. The analysis is based on the reversed-phase chromatographic separation of gadobenate ion from the endogenous components of biological matrices and detection by UV absorption at 210 nm. The selectivity of the method was satisfactory. The mean absolute recovery was greater than 95%. The precision and accuracy of the analytical methods were in the range 0.1-6.5% and -12 to +9.3%, respectively. The detection limits in plasma (0.1 ml), urine (0.05 ml), dried faeces (200 mg suspended in 4 ml water), bile (0.5 ml), and dried liver tissue (100 mg suspended in 1 ml water) were, respectively, 0.24, 0.47, 2.6, 0.63 and 2.8 nmol ml(-1) (corresponding to 0.16, 0.31, 1.7, 0.42 and 1.9 microg ml(-1)).  相似文献   

8.
A simple, specific, and sensitive radioimmunoassay was developed for the determination of the diuretic bumetanide in plasma and urine. Antiserum to bumetanide was obtained from rabbits immunized with an immunogen prepared by covalently coupling the glycine conjugate of bumetanide to bovine serum albumin. Following extraction of the sample at pH 5.5 with ether, radioimmunoassay of the residue from the ether extract allows for the determination of bumetanide with a limit of sensitivity of about 1 ng/ml using 0.1 ml of plasma or urine. The specificity of the radioimmunoassay was established by comparison with specific radiometric and spectrofluorometric techniques. The pharmacokinetic profile of bumetanide in eight human subjects receiving single 2-mg oral doses of the drug was elucidated using the radioimmunoassay. The peak plasma levels ranged from 39 to 50 ng/ml at 1-4 hr after administration and declined with a mean apparent half-life of 1.17 hr. The mean plasma clearance rate was calculated to be 255 ml/min. During the first 24 hr, a mean of 43% of the bumetanide dose was excreted in the urine as intact drug.  相似文献   

9.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and -10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and +/-2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at -80 degrees C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

10.
A high-performance liquid chromatographic (HPLC) method using fluorescence detection has been developed for the simultaneous analysis of low nanogram concentrations of an anti-inflammatory drug, 5-Bromo-2-(4-fluorophenyl)-3-[4-(methylsulfonyl)phenyl]thiophene (DuP 697), and a potential metabolite (X6882) in human plasma and of DuP 697 in human urine. This assay method used an EM Separations Lichrospher C18 endcapped column. The mobile phase was acetonitrile-water (75:25, v/v). The detection of DuP 697 and X6882 was by fluorescence at excitation and emission wavelengths of 256 and 419 nm, respectively. The chromatographic system could separate DuP 697 from X6882, the external standard (anthracene), and other endogenous substances present in human plasma. In human plasma the limits of quantification for DuP 697 and X6882 were 3 and 20 ng/ml, respectively; the limit of quantification for DuP 697 in human urine was 5 ng/ml. These compounds were shown to be stable in frozen (-20 degrees C) human plasma and urine for at least 9 weeks. The assay described has been used to characterize DuP 697 pharmacokinetics after oral administration in humans.  相似文献   

11.
12.
A sensitive and selective high-performance liquid chromatographic method with native detection of fluorescence was developed and validated for the quantitation of ivabradine and its N-demethylated metabolite in plasma (rat, dog, human) and human urine. The procedure involves the use of an analogue as internal standard, solid-phase extraction on cyano cartridges, separation on a Nova-Pak C8 column and fluorescence detection. Calibration curves are linear in the concentration ranges from 0.5 to 100 ng/ml in plasma and 2.0 to 500 ng/ml in urine with a limit of quantitation set at 0.5 and 2.0 ng/ml in plasma and urine, respectively. The analysis of plasma and urine samples (spiked with the analytes at low, medium and high concentrations of the calibration range) demonstrates that both analytes can be measured with precision and accuracy within acceptable limits. Quality controls spiked with analyte concentrations up to 10000 ng/ml can also be analysed with excellent precision and accuracy after dilution of the samples. The parent drug and its metabolite are stable in plasma and urine after short-term storage (24 h at room temperature and after three freeze-thaw cycles) as well as after long-term storage at -20 degrees C (at least 6 months in animal plasma and 12 months in human plasma and urine). The method has been used to quantify both compounds in plasma and urine samples from clinical and non-clinical studies with ivabradine.  相似文献   

13.
1 A gas chromatographic-mass spectrometric method was developed for determining 5-fluorouracil in plasma, using methylated thymine as an internal standard. 2 5-fluorouracil was extracted from plasma by a novel procedure which removed plasma components interferring with the sensitivity of the assay. The method included heating the plasma, washing with ether and extracting the drug under optimum conditions. 3 The sensitivity of the assay was 10 ng/ml plasma, sufficient to determine the low concentrations of 5-fluorouracil found in plasma during continuous infusion of the drug in patients receiving chemotherapy for cancer.  相似文献   

14.
Indinavir is a member of a class of protease inhibitors that actively prevent the acquired immunodeficiency syndrome virion from maturing. A high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of indinavir in human plasma. Indinavir and the internal standard were isolated from the plasma by ether extraction. The residue after evaporation of ether was reconstituted with buffer and injected onto a C4 reversed-phase column eluted isocratically with a mobile phase consisting of 35:65 (v/v) of acetonitrile and buffer. A wavelength of 210 nm was found to be optimum for detection. The calibration range of this assay was from 10 to 5000 ng/ml and coefficients of variation for the assay ranged from 4.6% to 11.0% for three different drug concentrations and the limit of quantitation was 10 ng/ml. During the validation, short-term stability of the drug in plasma, stability during heat deactivation and on repeated freezing and thawing of plasma was evaluated. The overall recovery of indinavir by the ether extraction method was 91.4%. This HPLC assay was found to be a simple and reproducible method for monitoring indinavir levels in human plasma obtained during clinical trials of the drug.  相似文献   

15.
A reversed phase HPLC method is described for the simultaneous estimation of rifampicin and its major metabolite desacetyl rifampicin, in the presence of isoniazid and pyrazinamide, in human plasma and urine. The assay involves simple liquid extraction of drug, metabolite and internal standard (rifapentine) from biological specimens and their subsequent separation on a C18 reversed phase column and single wavelength UV detection. In plasma as well as in urine samples, all the three compounds of interest eluted within 17 min. Using methanol-sodium phosphate buffer (pH 5.2; 0.01 M) (65:35, v/v) as mobile phase under isocratic conditions, it was established that isoniazid, pyrazinamide and ascorbic acid (added to prevent oxidative degradation of analytes) did not interfere with the analyte peaks. Recoveries (extraction efficiency) for drug were greater than 90% in both plasma and urine, whereas for metabolite the values were found to be 79 and 86% in plasma and urine, respectively. The plasma and urine methods were precise (total coefficient of variation ranged from 5 to 23%) and accurate (-7 to 5% of the nominal values) for both the analytes. Individual variance components, their estimates and their contribution to the total variance were also determined. Using the same method, unknown samples supplied by WHO were assayed and good correlations were obtained between the found and intended values. The method developed proved to be suitable for simultaneous estimation of rifampicin and desacetyl rifampicin in plasma and urine samples.  相似文献   

16.
A specific assay for the quantitative determination of the new antibiotic azithromycin in a low volume of human serum is described. The assay uses on-line high-performance liquid chromatography (HPLC) and atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI). Deuterium-labeled azithromycin was synthesized and used as the internal standard of the assay. The drug and the internal standard are extracted from 50 microliters of serum, and aliquots are injected onto a standard reverse-phase HPLC column. The effluent from the HPLC column at 1 ml/min is introduced into the atmospheric pressure source of a SCIEX API III mass spectrometer. Azithromycin concentrations in serum are determined by the selected monitoring of the protonated molecular ions of the drug and the internal standard. Our assay yields accurate and precise results over the range 10 ng/ml to 250 ng/ml. The correlation between the assay and a standard HPLC-electrochemical method, requiring a larger volume of serum, has been determined. The two methods showed excellent agreement. Because of its low volume requirement, our HPLC-APCI assay can be substituted for the standard assay for the investigation of azithromycin pharmacokinetics in children.  相似文献   

17.
A simple and rapid assay method for three stimulant drugs (amphetamine, methamphetamine, and dimethamphetamine) in human urine using solid-phase microextraction was developed. In solid-phase microextraction, the drugs were equilibrated between the adsorbent coated-fiber and aqueous sample matrix. After adsorption of the analytes, the fiber was directly transferred to the injector of a gas chromatograph, where the analytes were thermally desorbed and subsequently separated by the gas chromatograph and detected by mass spectrometer. The solid-phase microextraction method, which did not require solvents, was found to be a fast and simple analytical method. We optimized the solid-phase microextraction technique, for factors such as the NaCl salt effect (30%), pH effect (pH=12.4), equilibration time (30 min), desorption time (1 min) and coated-fiber type (100 microm poly(dimethylsiloxane)) and detected the stimulants in human urine, obtained from human subjects. The detection limits of each drug were below 1-10 ng/ml. The developed method can be applied to the abused drug test.  相似文献   

18.
Our studies on drug disposition in chronically instrumented pregnant sheep involve simultaneous administration of the antihistamine diphenhydramine (DPHM), its deuterated analogue ([2H10]DPHM) and their metabolites to the mother or the fetus via various routes. Such studies require sensitive and selective mass spectrometric methods for quantitation of these labeled and unlabeled compounds in order to assess comparative maternal and fetal drug metabolism. The objective of this study was to develop and validate a liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method for the simultaneous quantitation of DPHM, its N-oxide metabolite and their deuterium-labeled analogues in ovine plasma and urine. Samples spiked with the analytes and the internal standard, orphenadrine, were processed using liquid-liquid extraction. The extract was chromatographed on a propylamino LC column and MS/MS detection was performed in the positive ion electrospray mode using multiple reaction monitoring. The linear concentration ranges of the calibration curves for the N-oxides and the parent amines were 0.4-100.0 and 0.2-250.0 ng ml-1, respectively. In validation tests, the assay exhibited acceptable variability (< or = 15% at analyte concentrations below 2.0 ng ml-1 and < 10% at all other concentrations) and bias (< 15% at all concentrations), and the analytes were stable under a variety of sample handling conditions. Using this method, the labeled and unlabeled N-oxide metabolite was identified in fetal plasma after DPHM and [2H10]DPHM administration. This method will be used further to examine the comparative metabolism of diphenhydramine to its N-oxide metabolite in the mother and the fetus.  相似文献   

19.
An analytical method based on radioimmunoassay (RIA) has been developed for the determination of the antiarrhythmic agent, MK-0499, in plasma and urine. Owing to the potency of the drug, the specificity of this assay in human plasma could not be adequately determined using conventional RIA procedures. A highly specific procedure, based on LC/MS-MS, was developed to cross-validate the RIA. The lower quantifiable limits of the RIA and LC/MS-MS-based methods were 0.05 and 0.013 ng ml-1, respectively. Cross-validation data, compared using paired student's t-test regression analysis, showed excellent correlation between methods. The mass spectrometric assay was also used to simultaneously measure plasma concentrations of unlabeled and 14C-labeled MK-0499 following administration of the drug at high specific activity to volunteers.  相似文献   

20.
A sensitive and specific method is described for the quantitative analysis of 6,11-dihydro-11-oxo-dibenz[b,e]oxepin-3-acetic acid (oxepinac) in human plasma, urine and saliva. Oxepinac and internal standard are extracted from acidified plasma, urine or saliva, converted to the corresponding n-propyl esters and analysed by gas chromatography--mass fragmentography using selected ion monitoring. The method is accurate and precise over the range 100 microgram/ml to 1.0 ng/ml. The method has been applied to the analysis of plasma, urine and saliva from healthy volunteers receiving therapeutic doses of oxepinac.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号