1.
Seven hundred thirty-seven clinical samples from 460 patients were processed for direct detection of Mycobacterium tuberculosis complex by a semiautomated ligase chain reaction commercial assay, the LCx Mycobacterium tuberculosis Assay (LCx assay) from Abbott Laboratories. Results were compared to those of direct microscopy and standard microbiological culture. Of 26 patients (5.7%) with a culture positive for M. tuberculosis, 22 (84.6%) were found positive by the LCx assay. The sensitivity of the LCx assay was 98% for smear-positive samples and 27% for smear-negative samples. With an overall culture positivity rate for M. tuberculosis of 8.3% (61 of 737 samples) and after resolution of discrepant results according to clinical data, the sensitivity, specificity, and positive and negative predictive values of the LCx assay were 78, 100, 95, and 98%, respectively, compared to 85, 100, 100, and 98%, respectively, for culture and 67, 99, 87, and 97%, respectively, for acid-fast staining. In conclusion, the LCx assay proved satisfactory and appears to be an easy-to-use 1-day test which must be used with standard culture methods but can considerably reduce diagnosis time versus culture. However, its clinical interest appears to be limited in our population with low mycobacterial prevalence because of its cost considering the small gain in sensitivity versus direct microscopy.  相似文献   

2.
The aim of this study was to compare the results of a commercial assay based on the ligase chain reaction [(LCR) LCx Probe System MTB; Abbott, USA] with those of culture in liquid medium (Septi-Chek AFB; Becton-Dickinson, USA) and culture on the egg-based L?wenstein-Jensen solid medium for the direct detection of Mycobacterium tuberculosis complex in nonrespiratory specimens. The results were analyzed according to the standard definition of a true-positive result. Two hundred thirty-five nonrespiratory samples routinely submitted to rule out tuberculosis were analyzed. All samples were smear-negative. Mycobacterial growth in either culture medium was detected in 18 (7.6%) specimens: Mycobacterium tuberculosis was recovered from seven (38.9%) specimens cultured on L?wenstein-Jensen medium and from 18 (100%) specimens cultured in Septi-Chek AFB. The LCR protocol was positive in 22 specimens. None of the LCR-negative controls showed positive results. All samples positive by culture on L?wenstein-Jensen medium were positive by culture in liquid medium and by the LCR assay. However, Mycobacterium tuberculosis was detected by culture in liquid medium in two specimens that were negative by the LCR assay, whereas six specimens negative by culture in liquid medium were positive by the LCR protocol; three of these were identified as true-positive results of the LCR assay. The sensitivity, specificity, and positive and negative predictive values were 33.3%, 100%, 100%, and 93.8%, respectively, for L?wenstein-Jensen medium; 85.7%, 100%, 100%, and 98.6% for the liquid medium; and 90.4%, 98.5%, 86.3%, and 99% for the LCR assay. These findings indicate that the LCR assay may be a valid method of high diagnostic yield for direct detection of Mycobacterium tuberculosis complex in nonrespiratory specimens.  相似文献   

3.
This study aims to evaluate the performance of a new diagnostic method (LCx Tuberculosis Assay, Abbott Laboratories) based on Ligase Chain Reaction (LCR) technology, for the detection of Mycobacterium tuberculosis in respiratory and non-respiratory specimens and compare it with standard microbiological data and the clinical diagnosis of tuberculosis. Nine hundred specimens were collected from patients with a high suspicion of tuberculosis (740 respiratory samples and 160 non-respiratory specimens). The study was divided into two separate groups: samples washed and distilled water (207 samples) and unwashed samples that were directly resuspended in phosphate buffer (693 samples). The overall sensitivity, specificity, positive and negative predictive values of samples washed with distilled water after decontamination with SDS-NaOH were: 54%, 100%, 100%, and 94%, respectively. If these results were divided according to origin of specimens, the sensitivity, specificity, positive and negative predictive values in respiratory and non-respiratory samples were 54.5%, 100%, 100%, 94% and 50 100%, 100%, 93%, respectively. In contrast, for the non-washed samples, values were 85%, 95%, 80% and 98%, respectively. Respiratory and non-respiratory samples gave values of 84%, 96%, 77%, and 97.5% versus 89%, 99%, 94%, and 98%. The LCx M. tuberculosis assay is a novel, semi-automated assay and a rapid and highly specific technique for screening all forms of tuberculosis, including non-respiratory forms.  相似文献   

4.
Several nucleic acid amplification techniques (NAAT) have been developed for rapid and direct detection of Mycobacterium tuberculosis (MTB) from clinical specimens. This study compared the performances of the Gen-Probe Amplified MTB Direct Test (AMDT), Roche Amplicor MTB PCR test, and an IS6110-PCR assay with acid-fast smear and culture in the detection of MTB from 428 respiratory specimens from 259 patients. Patients' charts were reviewed for clinical correlation. Of 98 specimens that were clinically positive for MTB, acid-fast smear was positive in 50% of cases, culture in 93%, IS6110-PCR in 83%, AMDT in 84%, and Amplicor MTB PCR in 80%. Of 337 specimens that were negative for MTB, 117 (35%) were positive for nontuberculous mycobacteria. Specificities were as follows: smear, 89%; culture, 100%; IS6110-PCR, 99%; AMDT, 98%; and Amplicor MTB PCR, 96%. The accuracies of the tests were 80%, 98%, 96%, and 92%, respectively. MTB culture-positive specimens that were smear-negative were detected by AMDT and IS6110-PCR in 77% of cases and by Amplicor MTB PCR in 70%. NAAT was less sensitive than was culture for detection of MTB, but all these techniques had acceptable accuracy and were completed within hours. NAAT may be useful for rapid screening of respiratory specimens to distinguish MTB from nontuberculous mycobacteria infection in order to isolate patients.  相似文献   

5.
We evaluated the performance of an automatic polymerase chain reaction (PCR) detection system for identification of Mycobacterium tuberculosis in respiratory specimens. Six hundred and two respiratory specimens, including 557 sputa and 45 bronchial washing samples, were analyzed using the COBAS AMPLICOR Mycobacterium tuberculosis (MTB) test. The results were compared with those obtained from acid-fast microscopy, conventional culture, and clinical history. In cases of discrepancy between the results of the COBAS AMPLICOR MTB test and culture, the medical history of the patient was reviewed, the COBAS AMPLICOR MTB test was repeated, and the gene encoding M. tuberculosis superoxide dismutase was screened using PCR (SOD-PCR). Fourteen samples were excluded because the internal control test result was negative. Of 57 specimens that were culture positive for Mycobacterium species, 40 appeared to have growth of M. tuberculosis and 21 were smear positive for acid-fast bacteria. The sensitivity, specificity, and positive and negative predictive values for the COBAS AMPLICOR MTB test evaluated at our laboratory were 85.0% (34/40), 99.3% (544/548), 89.5% (34/38), and 98.9% (544/550), respectively. Three specimens that were culture positive for M. tuberculosis but negative by COBAS AMPLICOR MTB test were positive when rechecked by both COBAS AMPLICOR MTB test and SOD-PCR. Among the four specimens with positive reactions on both COBAS AMPLICOR MTB test and SOD-PCR that were culture negative, two were from patients who had been receiving antituberculosis treatment, one was from a patient who had been treated for tuberculosis for 1 year, and the other was from a patient who died of sepsis with adult respiratory distress syndrome. In more than 70% of smear-negative and culture-positive specimens and 86.4% of smear-positive specimens, M. tuberculosis was identified by the COBAS AMPLICOR MTB test within 10 hours after receipt of the specimens. Our data show that the COBAS AMPLICOR MTB test provides rapid and accurate detection of M. tuberculosis in respiratory specimens.  相似文献   

6.
The diagnostic performance of a PCR test (Roche Cobas Amplicor CT/NG Test) and that of a ligase chain reaction (LCR) test (Abbott LCx Chlamydia trachomatis assay) were compared by using endocervical and urethral swab specimen culture as a reference test. First-void urine (FVU) and endocervical and urethral swab specimens were collected from 1,015 unselected patients attending a sexually transmitted disease clinic and a clinic for adolescents in Helsinki, Finland. Chlamydia trachomatis was cultured from samples from the endocervix or urethra. PCR was performed with fresh and frozen urine and the culture transport medium. LCR was performed with fresh and frozen urine and LCx swab transport medium. Diagnostic consistency and diagnostic accuracy were statistically tested. The test results were identical for 984 patients (97%). Discrepant results were observed for 31 patients. Overall, LCR and PCR showed excellent kappa coefficients of consistency for both swab and FVU specimens (0.93 and 0.95, respectively). Sixty-one patients (6%) were culture positive. Testing of FVU by LCR or PCR increased the overall positivity rates to 7.0 and 7.7%, respectively. While PCR of FVU detected the greatest number of C. trachomatis infections (sensitivity, 96.1%), for some PCR-positive FVU specimens the results could not be confirmed (specificity, 99.6%). PCR and LCR were more sensitive than culture (sensitivities, 92 and 93% versus 79% for culture) in the diagnosis of genital C. trachomatis infection. In conclusion, both tests can be recommended for use in the clinical laboratory and for the screening of asymptomatic C. trachomatis infections.  相似文献   

7.
We evaluated the clinical efficacy of LCR MTB, a reagent developed by Abbott in the USA, in the full automatic ligase chain reaction (LCR) for detection of DNA of M. tuberculosis complex using a thermostable ligase. Using 458 samples isolated from patients with tuberculosis, LCR was compared with a smear method and with a culture method, and was also compared with two other methods of gene amplification, MTD and Amplicor, using 340 and 200 of the 458 samples, respectively. The LCR method detected M. tuberculosis in 49.8% (228/458) of the samples, and was superior to the smear method (31.9%, 146/458) and the culture method (39.1%, 179/458) in sensitivity. The LCR method was also superior to the MTD and Amplicor methods; sensitivity were 37.9% (129/340) for MTD vs. 47.6% (162/340) for LCR, and 56.5% (113/200) for Amplicor vs. 59.5% (119/200) for LCR. These favorable results and the convenience of the LCR method, which enables rapid detection of target genes with a high degree of sensitivity, strongly suggest that LCR MTB is useful as a reagent for detection of M. tuberculosis using nucleic acid amplification.  相似文献   

8.
The LCx Mycobacterium tuberculosis ligase chain reaction system (Abbott Diagnostic Division, Abbott Park, Ill.) was used to detect M. tuberculosis in 150 consecutive BACTEC vials on the day on which a positive growth index (GI) was recorded. By LCx, M. tuberculosis DNA was detected in BACTEC vials on average 2.6 days before the presence of acid-fast bacilli could be confirmed by microscopic examination. A total of 106 of 108 M. tuberculosis isolates were detected without centrifugation from bottles presenting very low GIs (average, 70; median, 33). No false-positive result was obtained from nontuberculous mycobacteria or from isolates with contaminants.  相似文献   

9.
We evaluated the COBAS AMPLICOR PCR system (Roche Diagnostics) for the routine detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. Diagnostic culture, considered as the reference method, was performed with BACTEC, L?wenstein-Jensen, Stonebrink, and Kirchner media. Occasionally MB-Redox, ESP, or MGIT medium was also used. A total of 643 respiratory and 506 nonrespiratory specimens collected from 807 patients were investigated. Of the 95 culture-positive specimens, 80 were COBAS AMPLICOR MTB positive, and of the 1,054 culture-negative specimens, 1,044 were COBAS AMPLICOR MTB negative. After resolving discrepancies by review of the medical history, the overall sensitivity, specificity, and positive and negative predictive values for the COBAS AMPLICOR MTB assay, respectively, were 83.5, 98.8, 86.7, and 98.6% compared to those of diagnostic culture. In smear-positive specimens, the sensitivity of the COBAS AMPLICOR MTB assay was 96%, versus 48% for smear-negative specimens. No significant differences in the test performance between respiratory and nonrespiratory specimens were observed. The overall inhibition rate was less than 2%, excluding stool specimens. The clear advantages of the COBAS AMPLICOR PCR system are standardized procedures and reagents for specimen processing as well as an internal control for reliable monitoring of PCR inhibitors. By simplifying the work flow through a completely automated amplification and amplicon detection procedure, the COBAS AMPLICOR PCR system proved itself as a very useful component for routine diagnostic procedures.  相似文献   

10.
The reliability of the BDProbeTec MTB Test (Becton Dickinson, Sparks, Md.) for direct detection of Mycobacterium tuberculosis in respiratory specimens was evaluated by comparing results to those of conventional mycobacterial culture, with the BACTEC TB 460 and Middlebrook 7H11 biplates. Patients known to have tuberculosis were excluded from analysis. Of 523 specimens from 277 patients, 53 grew a mycobacterium: 24 specimens of M. tuberculosis and 29 specimens of nontuberculous mycobacteria. After initial testing, 42 specimens were positive by the BDProbeTec, for overall sensitivity, specificity, and positive and negative predictive values of 95.8, 96. 2, 54.8, and 99.8%, respectively. After resolution of discrepancies, 28 specimens were positive by the BDProbeTec, for overall sensitivity, specificity, and positive and negative predictive values of 100, 99.2, 85.7, and 100%, respectively. These same values were 100, 80.8, 93.4, and 100%, respectively, for smear-positive samples and 100, 99.4, 75.0, and 100%, respectively, for smear-negative specimens.  相似文献   

11.
We evaluated the sensitivity and specificity of a new semiautomated direct amplification test (DAT), the LCx-MTB, for the diagnosis of pulmonary tuberculosis (TB) and assessed its positive predictive value by focusing on patients with high clinical and radiologic suspicion of pulmonary TB. Respiratory tract specimens from 32 consecutive patients with high suspicion of active pulmonary TB (case patients) and from 204 control patients were cultured for Mycobacterium tuberculosis and tested by LCx-MTB. Sensitivity and specificity of LCx-MTB when compared with culture was, respectively, 80 and 98%. Pulmonary TB was confirmed in the 32 case patients without knowledge of the LCx results: 18 patients were smear- and culture-positive for M. tuberculosis, and all gave at least one specimen that was LCx-positive. Eight patients were smear-negative culture-positive, and seven gave at least one LCx-positive specimen. LCx-MTB was negative in all the specimens obtained from six patients with smear- and culture-negative TB. A positive LCx-MTB result in a smear negative specimen was 100% predictive that at least one of the case patients' specimens would yield M. tuberculosis. As a consequence, knowledge of the LCx-MTB results at the time of specimen collection could have hastened the start of the antituberculosis therapy in three (21%) smear-negative case patients and could have avoided unnecessary invasive diagnostic procedures in four (29%). We conclude that the sensitivity of LCx-MTB in detecting M. tuberculosis DNA in respiratory tract specimens is similar to other DATs, that LCx-MTB is a reliable test for confirmation of TB in smear-positive patients and that LCx-MTB could be beneficial as a diagnostic step in smear-negative patients with a high suspicion of pulmonary TB.  相似文献   

12.
Two commercially available nucleic acid-based tests, ligase chain reaction (LCR; Abbott Laboratories) and PCR (Roche Diagnostics), for the detection of Chlamydia trachomatis in male and female urine samples were compared with culture and enzyme immunoassay (EIA) (Microtrak; Syva) for C. trachomatis detection in genital samples. The samples were collected from 1,005 patients who attended a sexually transmitted disease clinic. In this study population, the prevalence of the infection was 4%. Specimens which were reactive in any of the tests were retested with a different PCR test using primers directed against the major outer membrane protein gene. With a "gold standard" of a positive culture, or any other positive test result if it was confirmed by an independent test, the Roche PCR (95% sensitive, 99.9% specific) was more sensitive than the LCR (75% sensitive, 100% specific) (chi2, P < 0.0001) while both tests were more sensitive than culture (58% sensitive, 100% specific) or EIA (45% sensitive, 100% specific) (chi2, P < 0.001). The Roche PCR and Abbott LCR tests of urine identified 65% and 30% more positive patients, respectively, than did testing by culture of urethral or cervical specimens. Nucleic acid testing of urine specimens for C. trachomatis is a more sensitive and convenient method for the detection of genital infection.  相似文献   

13.
The Roche Amplicor Mycobacterium tuberculosis PCR test was compared with mycobacterial culture for direct detection of M. tuberculosis in extrapulmonary specimens. From January 1995 to October 1996, 124 clinical specimens from 112 patients were assessed, including 47 body fluids, 61 tissue specimens and 16 abscesses. The sensitivity and specificity of Amplicor PCR compared to culture were 63.6% and 93.1% respectively. Analysis of 7 PCR-positive, culture-negative specimens confirmed that all were from patients with recently diagnosed tuberculosis under treatment. Eight specimens were PCR negative-culture positive, including a pleural fluid containing inhibitory substances. On acid-fast bacilli (AFB) smear-negative specimens, sensitivity and specificity were 53 and 100% respectively. The best results for Amplicor PCR were obtained with abscesses and biopsies. It is concluded that this test, highly specific for the diagnosis of tuberculosis, is at least as sensitive on extrapulmonary specimens as on smear-negative respiratory specimens.  相似文献   

14.
We evaluated the use of the leukocyte esterase test (LET) on first-catch urine specimens from women as a screening test to predict infection with Chlamydia trachomatis. For diagnosis, we used Abbott's ligase chain reaction (LCR) on urine specimens and isolation by tissue culture (TC) on cervical brushes. Of 4,053 women attending sexually transmitted disease and family planning clinics, 4.3% (n = 174) were positive by TC and 5.9% (n = 239) were positive by LCR. When LET was compared to TC, the sensitivity, specificity, positive predictive value, and negative predictive value were 54.0, 67.0, 6.8, and 97.0%, respectively. The corresponding performance of LET versus LCR was 53.1, 67.3, 10.1, and 95.8%. Almost half of the laboratory-confirmed chlamydial infections were negative by LET. The low specificity probably reflects multiple causes of pyuria in women and results in a low positive predictive value. LET is neither sensitive nor specific as a predictor of chlamydial infection and cannot be recommended for use as a screening test for C. trachomatis with first-catch urine samples from females from low- or moderate-prevalence populations.  相似文献   

15.
The ligase chain reaction (LCR) is an in vitro nucleic acid amplification technique that exponentially amplifies targeted DNA sequences. In a multicenter study, we evaluated the use of a 4-h LCR-based assay for the diagnosis of Neisseria gonorrhoeae infection of the cervix and male urethra. The LCR results were compared with those of culture for N. gonorrhoeae by using selective media. This assay amplifies target sequences within the N. gonorrhoeae opacity gene. Discordant LCR-positive and culture-negative specimens were further evaluated by testing by another LCR assay which used N. gonorrhoeae-specific pilin probe sets. A total of 1,539 female endocervical specimens and 808 male urethral swab specimens were evaluated in the study. An expanded "gold standard" was defined to include all culture-positive as well as culture-negative, confirmed LCR-positive specimens. After resolution of discrepant samples, the sensitivities of the N. gonorrhoeae LCR assays for the female and male specimens were 97.3 and 98.5%, respectively, with specificities of 99.6 and 99.8%, respectively. Resolved culture sensitivities were 83.9 and 96.5% for the female and male specimens, respectively. The LCR assay for gonorrhea is a rapid, highly sensitive nonculture method for detecting gonococcal infection of the cervix and male urethra.  相似文献   

16.
The accuracy of detection of genital Neisseria gonorrhoeae infection in pooled urine samples by ligase chain reaction (LCR) was examined in three populations. Firstly, urine specimens from 300 female military recruits (FMR) were tested by LCR individually and in pools of four and six. Secondly, 300 urine specimens from middle-school students (MSS) were tested individually by LCR, and then the processed specimens were stored frozen for subsequent testing in pools of 4 and 10. Thirdly, 600 frozen urine specimens from high-school students (HSS) were tested by using the LCR pooling algorithm, i.e., testing processed specimens in pools of four in one test unit dose, and retesting individual specimens from positive pools. Finally, the pooling algorithm results were compared to culture results for a subset of 344 students from the original 600 HSS from whom cervical or urethral samples were taken at the discretion of the school nurse practitioners. Compared to individual testing of specimens by LCR in the FMR population, the pooling-by-four algorithm was 100% sensitive (5 of 5) and 100% pool specific (70 of 70), and the pool-by-six algorithm was 100% sensitive (5 of 5) and 100% pool specific (45 of 45). In the MSS population, the pool-by-4 algorithm was 95.8% sensitive (23 of 24) and 100% (52 of 52) pool specific, and the pool-by-10 algorithm was 95.8% sensitive (23 of 24) and 100% (17 of 17) pool specific. In the subset of 344 HSS from whom endocervical or urethral specimens were collected for culture, 31 were positive by LCR in urine and 26 were positive by culture. After results discrepant between culture and LCR were adjudicated by a confirmatory LCR test, the pooling algorithm was 93.8% (30 of 32) sensitive and 99.7% (311 of 312) specific. Culture from these 344 HSS was 81.3% (26 of 32) sensitive. The pooling algorithm reduced the cost of the N. gonorrhoeae LCR assay by 60% compared to individual testing of the HSS specimens and was both sensitive and specific.  相似文献   

17.
AIMS: To assess the performance of 2-sucrose-phosphate based transport medium (2-SP) for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae by an automated commercial polymerase chain reaction (PCR) and ligase chain reaction (LCR) compared to centrifugation culture on McCoy cells for C trachomatis. Second, to compare both amplification systems for initial diagnostic testing of a low prevalence population for sexually transmitted diseases. METHODS: Four hundred and eighty one consecutive urogenital and conjunctival specimens were examined. All tests were performed on the same specimen collected with a dacron swab and transported in 2-SP medium. Samples that were positive by culture or by both PCR and LCR were considered to be true positives. RESULTS: The prevalences of C trachomatis and of N gonorrhoeae were 2.7% and 0.4%, respectively. PCR had a resolved sensitivity and specificity of 100% and 99.8%, respectively, for C trachomatis, and 100% and 98.9%, respectively, for N gonorrhoeae. LCR was 100% sensitive and specific for both pathogens. The resolved sensitivity of the shell vial assay was 85%. No culture positive sample would have been missed by PCR or LCR. The inhibition rate for PCR was 4.8%. CONCLUSIONS: 2-SP medium proved to be suitable for both PCR and LCR. It is not limited to any one test manufacturer and allows the performance of amplification techniques and viral and chlamydia culture from the same specimen. The LCR was more reliable than PCR on initial testing. However, hands on time is longer, and no amplification control is available for LCR.  相似文献   

18.
19.
The aim of the study was to evaluate the applicability to urine samples of the Amplified Mycobacterium tuberculosis Direct Detection Test (AMTD), which is currently used to identify this organism in respiratory specimens within a few hours. The study was performed on 95 patients, comprising 35 subjects with a high index of suspicion for active tuberculosis of the urinary tract and 60 subjects with evidence of non-mycobacterial disease. One urine specimen from each subject was examined by microscopy, culture and AMTD. AMTD was positive in 38 specimens and negative in 57. Assuming culture as the reference standard, the sensitivity, specificity, positive predictive value and negative predictive value of AMTD were 100%, 91.93%, 86.84% and 100%, respectively. Reassessing the discrepancies between AMTD and culture by review of patients' charts, the sensitivity, specificity, positive predictive value and negative predictive value of AMTD were 100%, 93.44%, 89.47% and 100%. The results of the study as well as the characteristics of AMTD encourage its use for the rapid recognition of urinary tract tuberculosis, although its findings should be interpreted cautiously when the clinical picture is not consistent with an active tuberculosis.  相似文献   

20.
Serpentine cord formation in BACTEC 12B medium was evaluated as a rapid method for the presumptive identification of M. tuberculosis complex. Kinyoun acid-fast stained smears were prepared from 666 positive BACTEC 12B bottles and examined for the presence or absence of serpentine cording. Cord formation had a sensitivity, specificity, positive predictive value, and negative predictive value of 89.2, 99.2, 98.5, and 94.2%, respectively. The evaluation of the presence of cord formation in BACTEC 12B medium is reliable and permits the rapid presumptive reporting of M. tuberculosis.  相似文献   