首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hyperforin is one of the essential active ingredients of St. John's wort extract, which is used as an antidepressant for mild to moderately severe depressions. In vitro and in vivo data as well as several clinical studies and meta analyses have confirmed the pharmacological effect of treatment with hyperforin-containing preparations. However, little is known about the brain availability of hyperforin until now. Accordingly, a highly sensitive and selective LC/MS method for this purpose was developed and validated. This method proved suitable for the determination of hyperforin in mouse brain, after oral administration of hyperforin sodium salt and St. John's wort extract. This method involves liquid-liquid extraction of hyperforin with ethyl acetate followed by separation with rapid reversed-phase high-performance liquid chromatography and tandem mass spectrometry detection using electrospray ionization. Excellent linearity was obtained for the entire calibration range from 0.25 to 10 ng/mL (corresponding to 2.5-100 ng/g brain tissue concentration, calculated with the factor derived from sample processing) with an average coefficient of correlation of 0.9992. The recovery of hyperforin from mouse brain homogenates was between 71.4 and 75.3% with a relative standard deviation of less than 3%. Validation assays for the lower limit of quantitation yielded an accuracy of 5.8%. Intraday accuracy and precision for the developed method were between 4.6 and 10.6% and 4.3-8.4%, respectively, while the interday parameters varied between 6.7 and 12.2% for accuracy and 2.0-5.0% for precision. After the method validation, hyperforin brain levels in mice, treated with 15 mg/kg hyperforin (either as the sodium salt or as 5% St. John's wort extract), were investigated. The average concentration of hyperforin found for the sodium salt group was 28.8+/-10.1 ng/g of brain (n = 8), which was somewhat higher than the hyperforin concentration of 15.8+/-10.9 ng/g of brain (n = 8), determined in the extract-treated group. This method is robust, selective, and highly sensitive and represents an appropriate tool to further prove the occurrence and distribution of hyperforin in mouse brain.  相似文献   

2.
A method has been developed for the trace analysis of 27 compounds from a diverse group of pharmaceuticals, steroids, pesticides, and personal care products. The method employs solid-phase extraction (SPE) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), using electrospray ionization (ESI) in both positive and negative modes and atmospheric pressure chemical ionization in positive mode. Unlike many previous methods, a single SPE procedure using 1 L of water coupled to a simple LC method is used for all ionization modes. Instrument detection limits for most compounds were below 1.0 pg on column with reporting limits of 1.0 ng/L in water. Recoveries for most compounds in deionized water were greater than 80%. Sulfuric acid was found to be the preferred sample preservative, and structures of all MS/MS product ions are proposed. Matrix effects from waters with a high content of treated municipal effluent were observed in both ESI modes and are discussed in the paper.  相似文献   

3.
A new method was developed for the analysis of natural and synthetic androgenic steroids and their selected metabolites in aquatic environmental matrixes using direct large-volume injection (LVI) high-performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Method accuracy ranged from 87.6 to 108% for analytes with well-matched internal standards. Precision, quantified by relative standard deviation (RSD), was less than 12%. Detection limits for the method ranged from 1.2 to 360 ng/L. The method was demonstrated on a series of 1 h composite wastewater influent samples collected over a day with the purpose of assessing temporal profiles of androgen loads in wastewater. Testosterone, androstenedione, boldenone, and nandrolone were detected in the sample series at concentrations up to 290 ng/L and loads up to 535 mg/h. Boldenone, a synthetic androgen, had a temporal profile that was strongly correlated to testosterone, a natural human androgen, suggesting its source may be endogenous. An analysis of the sample particulate fraction revealed detectable amounts of sorbed testosterone and androstenedione. Androstenedione sorbed to the particulate fraction accounted for an estimated 5 to 7% of the total androstenedione mass.  相似文献   

4.
The native reference peptide (NRP) method has been adapted to the measure of the degree of protein nitration at a specific tyrosine residue. In these experiments, human serum albumin was modified in a myeloperoxidase-mediated reaction in the presence of nitrite, with nitration detected predominantly at one site, Y162. The time-dependent increase in nitration at this site was measured based on the increasing abundance of the peptide 162YnLYEIAR168 and the corresponding decrease in the 162YLYEIAR168 peptide in in-gel trypsin digests. The peptide 66LVNEVTEFAK75, also formed in the tryptic digest, was used as the native reference peptide. Quantitation was achieved by determining the chromatographic peak area of the two analyte peptides relative to the native reference peptide by LC/tandem mass spectrometric analyses with selected reaction monitoring. The NRP results were validated by correlation to the time-dependent increase in total protein-nitrotyrosine content determined by Western blot analysis. The precision and limit of detection of the assay were also evaluated and were found to be approximately 10% (relative standard deviation) and 5 fmol on-column, respectively. These results demonstrate the utility of the NRP method for quantitative analyses of posttranslation modifications, in terms of broad applicability, ease of experimental design, sensitivity, and precision.  相似文献   

5.
Peritumoral edema, one of the major causes for neurological disorders in brain tumor patients, is mainly treated with steroids, which unfortunately have significant side effects and interfere with the efficacy of chemotherapy. Boswellic acids, the main active ingredients of Boswellia serrata, are antiinflammatory agents, inhibiting 5-lipoxygenase, the key enzyme of leukotriene biosynthesis and one of the pathophysiological mechanisms of peritumoral edema. Based on positive results in clinical trials and animal studies, B. serrata resin dry extract was designated an orphan drug by the European Commission for the treatment of peritumoral edema resulting from brain tumors. Thus boswellic acids may be alternative drugs to corticosteroids. However, the question of the availability of boswellic acids in brain has not been addressed until now. Accordingly, a highly sensitive LC/MS method has been developed for the simultaneous determination of KBA and AKBA, the most potent boswellic acids, in plasma and brain. This method involves matrix-assisted liquid-liquid extraction on Extrelut NT followed by separation on reversed-phase high-performance liquid chromatography and tandem mass spectrometry detection using atmospheric pressure chemical ionization. Excellent linearity was obtained for the entire calibration range from 5 to 1500 ng/mL KBA and AKBA in plasma and 5 to 1000 ng/mL KBA and AKBA in brain. Validation assays of the lower limit of quantification as well as for the intra- and interday precision and accuracy met the international acceptance criteria for bioanalytical method validation. Moreover, the interchangeability of calibration curves generated in pork and rat brain homogenates could be demonstrated. Using the developed analytical method, KBA and AKBA could be detected for the first time in brain up to a concentration of 99 and 95 ng/g of brain, respectively, 3 h after the single oral administration of 240 mg/kg of dry B. serrata resin extract to Wistar rats. The developed method represents an appropriate tool to further study the time-dependent distribution of KBA and AKBA in plasma and brain as well as the absolute brain concentration after multiple doses and contributes thus to the optimization of the dosage regimen and to a better understanding of the therapeutic effects of B. serrata.  相似文献   

6.
Chu S  Metcalfe CD 《Analytical chemistry》2007,79(13):5093-5096
Acrylamide is a probable human carcinogen, and the drinking water quality guideline for this compound is 0.5 mg/L. However, analysis of this compound in water is difficult because of its very high water solubility, which limits the efficiency of sample preconcentration prior to analysis. We developed a robust and sensitive analytical method for the determination of trace quantities of acrylamide in samples of water using a novel preparative technique and isotope dilution liquid chromatography tandem mass spectrometry with atmospheric pressure chemical ionization as the ion source (LC-APCI-MS/MS). The preparative method involves coevaporation of acrylamide with water at pH 10 using a rotary evaporator, followed by acidification to pH 3.0 and concentration of the sample prior to analysis by LC-APCI-MS/MS. To compensate for the loss of the analyte during sample preparation and signal suppression due to interference from the sample matrix, isotope dilution with acrylamide-d3 was used for quantitation. Using this method, analyte recoveries ranged from 74 to 103% for acrylamide spiked into water at a concentration of 0.4 ng/mL. The limit of detection and limit of quantification (LOQ) for acrylamide in water were 0.02 and 0.06 ng/mL, respectively. This method was successfully applied to determine trace levels of acrylamide in samples of river water and in runoff from an agricultural field to which municipal biosolids (i.e., sludge) had been applied. Concentrations of acrylamide in these samples ranged from 相似文献   

7.
建立液相色谱串联质谱法测定烟草中20种游离氨基酸的方法。烟草样品经0.1%的盐酸溶液超声萃取并离心后,直接进样测定。色谱柱采用XTerra MS C18(50mm×2.1mm×2.5μm),0.1%甲酸溶液和乙腈为流动相。结果表明:20种氨基酸的检出限为0.001~0.011μg/mL,标准曲线的拟合度均大于0.999,回收率在86.4%~105.9%之间。该方法操作简单,灵敏度高,适用于烟草中游离氨基酸的检测。  相似文献   

8.
建立了芹菜中氟虫腈及其代谢物(氟甲腈、氟虫腈硫醚和氟虫腈砜)残留的液相色谱/串联质谱检测方法。样品以乙腈提取,采用电喷雾离子源负离子检测模式(ESI-)和多重反应监测(MRM)模式测定,基质匹配标准曲线定量。结果表明:芹菜基质中,氟虫腈、氟甲腈、氟虫腈硫醚和氟虫腈砜在0.01~0.1mg/L范围内线性关系均较好(r0.995),方法检出限和定量限分别为0.45~1.20μg/kg和1.5~4.0μg/kg;5、50和100μg/kg三个添加水平下,方法回收率在72.3%~110.2%,相对标准偏差为5.0%~9.8%。该法简单、准确、快速、灵敏,符合法规残留限量监测要求。  相似文献   

9.
A method to determine five postharvest fungicides (dichloran, flutriafol, o-phenylphenol, prochloraz, tolclofos methyl) in fruits (cherries, lemons, oranges, peaches) has been developed using solid-phase microextraction (SPME) coupled to liquid chromatography (LC) with photodiode array (DAD), mass spectrometry (MS), or tandem mass spectrometry (MS/MS) with ion trap detection. Extraction involved sample homogenization with an acetone/water solution (5:1), filtration, and acetone evaporation prior to fiber extraction. The pesticides were isolated with a fused-silica fiber coated with 50-microm Carbowax/template resin. The effects of pH, ion strength, sample volume, and extraction time were investigated, and their impact on the SPME-LC/MS was studied. Dynamic and static modes of desorption were compared and the variables affecting desorption processes in SPME-LC optimized. Static desorption provided the best recoveries and peak shapes. Recoveries at the limit of quantification (LOQ) levels were between 10% for prochloraz and 60% for o-phenylphenol, with relative standard deviations from 13.6% for prochloraz to 3.1% for o-phenylphenol. The versatility of the method was also exhibited by its excellent linearity in the concentration intervals between 0.0005 and 5 mg kg(-1) for dichloran and 0.01-10 mg kg(-1) for tolclofos methyl and prochloraz. LOQs ranged from 0.25 to 1 microg g(-1) using DAD, from 0.002 to 0.01 microg g(-1) using LC/MS, and from 0.0005 to 0.01 to microg g(-1) using LC/MS/MS. LOQs obtained in the present study using LC/MS and LC/MS/MS are lower than maximum residue limits established for all the fungicides in any matrix studied. The method enables to determine polar pesticides at low-microgram per gram levels in fruits.  相似文献   

10.
Davis WE  Li Y 《Analytical chemistry》2008,80(14):5449-5453
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.  相似文献   

11.
Successful application of the Hadamard transform (HT) technique to gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) is described. Novel sample injection devices were developed to achieve multiple sample injections in both GC and LC instruments. Air pressure was controlled by an electromagnetic valve in GC, while a syringe pump and Tee connector were employed for the injection device in LC. Two well-known, abused drugs, 3,4-methylenedioxy-N-methylamphetamine (MDMA) and N, N-dimethyltryptamine (DMT), were employed as model samples. Both of the injection devices permitted precise successive injections, resulting in clearly modulated chromatograms encoded by Hadamard matrices. After inverse Hadamard transformation of the encoded chromatogram, the signal-to-noise (S/N) ratios of the signals were substantially improved compared with those expected from theoretical values. The S/N ratios were enhanced approximately 10-fold in HT-GC/MS and 6.8 in HT-LC/MS, using the matrices of 1023 and 511, respectively. The HT-GC/MS was successfully applied to the determination of MDMA in the urine sample of a suspect.  相似文献   

12.
Song Y  Feng Y  LeBlanc MH  Zhao S  Liu YM 《Analytical chemistry》2006,78(23):8121-8128
A sensitive chiral capillary HPLC-MS/MS method well suited for the determination of amino acid enantiomers in biological samples was developed. The method involved precolumn derivatization of the sample with 7-fluoro-4-nitrobenzoxadiazole (NBD-F). After derivatization, NBD-amino acids were stacked on a C18 reversed-phase extraction microcolumn, thus enriching and cleaning up the analytes. Various chiral stationary phases (CSPs) including cyclodextrin-bonded silica, Pirkle-type, vancomycin, and teicoplanin-bonded silica particles were evaluated for resolving NBD-F tagged amino acid enantiomers with mobile phases compatible with MS detection. It was found that only teicoplanin aglycon CSP provided sufficient resolution of NBD-Asp and NBD-Ser enantiomers to quantify trace levels of D-Asp and D-Ser in tissue samples. MS/MS detection of NBD-amino acid derivatives was very sensitive and selective. The high selectivity allowed the use of a stable isotope-labeled analyte analogue (i.e., L-aspartic acid-2,3,3-d3) as internal standard for the quantitation to improve assay reproducibility and reliability. Neural tissue samples dissected from rat brain and the central nervous system (CNS) of Aplysia californica, a widely used neuronal model, were analyzed to determine the chirality of glutamic acid (Glu), aspartic acid (Asp), and serine (Ser). The former two are major excitatory amino acids in the brain, and the last one has been recently identified as a neuromodulator. Both D-Ser and D-Asp were detected in rat brain. While the D-Asp level decreased rapidly through the developmental stages of the rat, the D-Ser level increased steadily from 82.3 microg/g of wet tissue in 3-day prenatal rats to 241.3 microg/g of wet tissue in 90-day-old rats. Interestingly, no D-Ser was detected in the CNS of Aplysia, a "primitive" invertebrate. However, the D-Asp level in this animal was found to be high. In a particular connective nerve sample, D-Asp was at 323.2 microg/g of wet tissue and constituted 60.2% of total Asp. D-Glu was not detected either in rat brain or in Aplysia's CNS.  相似文献   

13.
14.
Alkylbenzenesulfonates together with soap are the most widely used anionic surfactants. Linear alkylbenzenesulfonates (LAS) were introduced in the mid-1960s as substitutes for the poorly biodegradable tetrapropylenebenzenesulfonates (TPS). A method is presented for the selective and quantitative determination of LAS and TPS in recent sediments. Alkylbenzenesulfonates were extracted from sediments using methanol. The methanolic extract was passed through a strong anionic exchange column. The alkylbenzenesulfonates contained in the acidic eluate were then derivatized to their corresponding trifluoroethyl esters and quantitatively determined by gas chromatography/mass spectrometry using positive chemical ionization. Limits of quantitation for 10 g sediment samples varied between 1.5 and 21 μg/kg of dry sediment for single LAS isomers and between 71 and 220 μg/kg for total LAS. Limits of quantitation for the total of TPS were at ~200 μg/kg. Relative standard deviations of replicate analyses typically ranged from 5 to 10%. Recovery rates of LAS in spiked sediment samples ranged from 79 to 113%. The presented method was applied to surface and subsurface sediments also containing long-chain (C(14)-C(16))-LAS and mixtures of LAS and TPS.  相似文献   

15.
As part of a strategy for profiling diverse mixtures of sulfated mucin-derived oligosaccharides, liquid chromatography coupled to electrospray ionization tandem mass spectrometry (ESI-MS/MS) in the negative ion mode has been explored. Two mixtures of sulfated oligosaccharide alditols from porcine stomach and large intestine were analyzed by straight phase chromatography using an amino-bonded column connected to a Q-TOF instrument. Nine sulfated mucin-derived oligosaccharide alditols from porcine stomach underwent extensive fragmentation allowing determination of their sequence. The fragmentation generated primary, secondary, and tertiary fragment ions informative for the elucidation of the saccharide sequence and localization of the sulfate group. From a single chromatographic analysis, the sequences of 28 different sulfated mucin oligosaccharide alditols purified from porcine large intestine were elucidated, revealing information concerning prominent core sequences and terminal blood group-type epitopes. Analysis of these two sulfated oligosaccharide mixtures demonstrated the usefulness of HPLC-ESI-MS/MS: the on-line separation of multiple isomeric suffated oligosaccharides as present in biological samples, informative fragmentation allowing the identification of the sequence of nonderivatized oligosaccharides, and a sensitivity sufficient for the analysis of quantities as obtained from natural sources.  相似文献   

16.
An existing gas chromatograph/mass spectrometer (GC/MS) can be used to analyze gas and liquid fractions from the same system within a few minutes. The technique was applied to (a) separate and identify the gaseous components of the products of cracking an alkane, (b) measure trace levels of acetone in ethyl acetate, (c) determine the relative partial pressures over a binary mixture, and (d) identify nine unknown compounds for the purpose of disposal.  相似文献   

17.
Tai SS  Welch MJ 《Analytical chemistry》2004,76(4):1008-1014
Cortisol is an important diagnostic marker for the production of steroid hormones, and accurate measurements of serum cortisol are necessary for proper diagnosis of adrenal function. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(3), was added to serum, followed by equilibration and solid-phase and ethyl acetate extractions to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) and liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analyses. (M + H)(+) ions at m/z 363 and 366 for cortisol and its labeled internal standard were monitored for LC/MS. The transitions of (M + H)(+) --> [(M + H)(+) - 2H(2)O] at m/z 363 --> 327 and 366 --> 330 were monitored for LC/MS/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for cortisol [Certified Reference Materials 192 and 193] with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added cortisol. The results of this method for total cortisol agreed with the certified values within 1.1%. The recovery of the added cortisol ranged from 99.8% to 101.0%. This method was applied to the determination of cortisol in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.3%-1.5% and between-set CVs of 0.04%-0.4% for both LC/MS and LC/MS/MS analyses. The correlation coefficients of all linear regression lines ranged from 0.998 to 1.000. The detection limits (at a signal-to-noise ratio of approximately 3-5) were 10 and 15 pg for LC/MS and LC/MS/MS, respectively. This method, which demonstrates good accuracy and precision, and is free from interferences from structural analogues, qualifies as a candidate reference method and can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared.  相似文献   

18.
19.
Perfluorinated surfactants are an important class of specialty chemicals that have received recent attention as a result of their persistence in the environment. Two analytical methods for the determination of perfluorinated surfactants in aqueous samples were developed in order to investigate a spill of 22000 L of fire retardant foam containing perfluorinated surfactants into Etobicoke Creek (Toronto, Ontario). With the first method, aliquots of surface water (0.2-200 mL) were preconcentrated using solid-phase extraction. Liquid chromatography/tandem mass spectrometry was employed for identification and quantification of each perfluorinated surfactant. Total perfluorinated surfactant concentrations in surface water samples ranged from 0.011 to 2270 microg/L, and perfluorooctanesulfonate was the predominant surfactant observed. Interestingly, perfluorooctanoate was detected in surface water sampled upstream of the spill. A second method employing 19F NMR was developed for the determination of total perfluorinated surfactant concentrations in aqueous samples (2-100 mL). By 19F NMR, the surface water concentrations ranged from nondetect (method detection limit, 10 microg/L for a 100-mL sample) to 17000 microg/L. These methods permit comprehensive evaluation of aqueous samples for the presence of perfluorinated surfactants and have applicability to other sample matrixes.  相似文献   

20.
硝基呋喃类药物及其代谢产物可使实验动物发生癌变、基因突变,同时具有生殖毒性,可能对人体产生危害。因此,硝基呋喃含量的检测在食品安全中是至关重要的,本文采用液相色谱串联质谱技术检测四种硝基呋喃类代谢物。硝基呋喃类代谢物在酸性条件下经过2-硝基苯甲醛衍生化,用乙酸乙酯提取纯化,电喷雾离子化,液相色谱-串联质谱检测。结果表明,四种硝基呋喃类药物的色谱峰面积与浓度在0.1~10.0 ng/mL范围内均呈现很好的线性关系,该方法具有操作简便、灵敏、准确等优点。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号