共查询到20条相似文献,搜索用时 15 毫秒
1.
Large quantities of a number of man-made chemicals with the potential to disrupt the developing endocrine and nervous systems in wildlife and humans have been released into the environment. These chemicals are particularly damaging during the embryonic, fetal, and early postnatal periods because they resemble or interfere with the hormones, neurotransmitters, growth factors, and other signaling substances that normally control development. The effects are in many cases irreversible and often are expressed as changes in function rather than as obvious birth defects or clinical diseases. Functional changes pose challenges in documenting the extent of the lesion, especially in the case of neuroendocrinological damage. In the past decade, researchers have added new dimensions to their research strategies in order to compensate for these difficulties. The new approaches reveal more about the extent of the distribution of and exposure to chemicals that interfere with the endocrine and nervous systems and strengthen the links between exposure and damage in developing wildlife and humans. Based on this new knowledge, opportunities abound for extensive multi-disciplinary research involving developmental neurotoxicity. 相似文献
2.
P de Bruijn J Verweij WJ Loos HJ Kolker AS Planting K Nooter G Stoter A Sparreboom 《Canadian Metallurgical Quarterly》1999,266(2):216-221
A high-performance liquid chromatographic assay with fluorescence detection has been developed for the determination of doxorubicin and its metabolite doxorubicinol in plasma of cancer patients. Quantitative extraction was achieved by a single protein-precipitation step of 1-ml samples with 500 microl of acetone in the presence of 100 microl of zinc sulfate [70% (w/v) in water]. Doxorubicin and doxorubicinol were separated isocratically on a column packed with Inertsil ODS-80A material and a mobile phase composed of water:acetonitrile:tetrahydrofuran (76:24:0.5, v/v/v). The related compound daunorubicin was used as internal standard. The column effluent was monitored fluorimetrically at an excitation wavelength of 480 nm and an emission wavelength of 560 nm, with a band width of 40 nm. The calibration graphs of doxorubicin and doxorubicinol were linear over a range of 1.0 to 100 and 0.50 to 50. 0 ng/mL, respectively, with lower limits of quantitation of 1.0 and 0.50 ng/ml. Results obtained from a 4-day validation study demonstrated excellent accuracy (91.0-106%) and precision (0.90-10. 2%) across the calibration ranges for both compounds. The developed method has been applied extensively to a clinical study to examine the pharmacokinetics and metabolism of doxorubicin in patients cotreated with a potent inhibitor of MDR1 P-glycoprotein activity, GF120918. 相似文献
3.
R Ricciarello S Pichini R Pacifici I Altieri M Pellegrini A Fattorossi P Zuccaro 《Canadian Metallurgical Quarterly》1998,707(1-2):219-225
A method is described which permits the trace analysis of 10 chlorobenzenes in aqueous samples. Chlorobenzenes were extracted from water samples by solid-phase extraction with a C18 cartridge and analysis was carried out by gas chromatography-mass spectrometry in the selected-ion monitoring mode. The recovery and precision of the method were evaluated by extraction of spiked reagent-grade water at concentration levels of 0.1, 1.0 and 10.0 micrograms/l. This method was applied to the determination of chlorobenzenes in tap, ground and river water. By preparing 200 ml of environmental water samples, the detection limits of the compounds studied were in the range of 0.010-0.042 microgram/l. 相似文献
4.
I Abraham JP Fawcett J Kennedy A Kumar R Ledger 《Canadian Metallurgical Quarterly》1997,703(1-2):203-208
A sensitive analytical procedure is described for the simultaneous determination of lignocaine and the enantiomers of bupivacaine in biological fluids using diazepam as an internal standard. After solvent extraction into hexane, the local anaesthetics were separated using an alpha1-acid glycoprotein (AGP) column and detected at 214 nm. Calibration curves were linear (r2>0.99) in the concentration range of 5 to 500 ng/ml for the enantiomers of bupivacaine and 12.5 to 1000 ng/ml for lignocaine. The corresponding limits of detection were 4 ng/ml and 10 ng/ml, respectively. The method was applied to the analysis of plasma from a healthy woman undergoing tubal ligation. 相似文献
5.
In a double blind study of 58 episodes of fever and profound neutropenia, children with cancer received either recombinant human granulocyte-macrophage colony-stimulating factor (rhGM-CSF) or placebo, combined with identical antimicrobial therapy, i.e. imipenem, on admission. The criteria for discontinuation of therapy were identical. A difference was demonstrated both in the number of hospital days, totaling 252 days in the rhGM-CSF group and 354 in the placebo group, days receiving antibiotics (220 vs. 322), and in the resolution of neutropenia (4.5 days vs. 6.0 days; P < 0.05). The number of episodes requiring antimicrobial therapy for longer than 10 days was 5 of 28 (12%) in the rhGM-CSF group as opposed to 15 of 30 (50%) in the placebo group (P = 0.01). rhGM-CSF was well-tolerated. We conclude that rhGM-CSF was efficacious in accelerating myeloid recovery and reducing the length of hospitalization in febrile neutropenia. 相似文献
6.
A sensitive and selective reversed-phase high-performance liquid chromatographic method for the quantification of doxorubicin and its metabolites doxorubicinol, 7-deoxydoxorubicinone and 7-deoxydoxorubicinolone was developed and validated for a variety of murine specimens. Daunorubicin was used as internal standard. Sample pretreatment involved liquid-liquid extraction of 200 microl sample with 1 ml of chloroform-1-propanol (4:1, v/v). Chromatographic separation was achieved isocratically on a LiChrosorb RP-8 analytical column at ambient temperature. The mobile phase consisted of acidified water (pH 2.05)-acetonitrile-tetrahydrofuran (80:30:1, v/v/v). The column effluent was monitored fluorimetrically at an excitation wavelength of 460 nm and an emission wavelength of 550 nm. The lower limits of quantitation were in the range 1.8-2.4 nM. Spiked murine specimens and samples from treated mice were subjected to stability studies. The results demonstrated the importance of validation in all relevant specimens, since the accuracy and precision were highly matrix-dependent. Accuracies and precisions of measured drug concentrations in liver, spleen, muscle, gastrointestinal tissues, diluted bile, feces and urine were lower than in the other matrices. Doxorubicin was unstable in diluted bile, but not in the other specimens. The method is suitable for studying the pharmacokinetics of doxorubicin and its metabolites in mice. 相似文献
7.
EC Van Os JA McKinney BJ Zins DC Mays ZH Schriver WJ Sandborn JJ Lipsky 《Canadian Metallurgical Quarterly》1996,679(1-2):147-154
We investigated whether linear whole-body acceleration along the interaural y-axis influenced the concurrent perception of visual motion direction as has been shown for angular accelerations. A sled running on air bearings along a 7.5-m track was used to accelerate 18 subjects at two different linear accelerations. These young, healthy volunteers, aged 25.50 +/- 7.38 years, used a joystick to indicate whether or not they perceived visual motion to the left within a random-dot kinematogram continuously presented on a monitor moving with them. The percentage of coherently leftward moving pixels presented for a 640-ms period during acceleration was adjusted according to a Modified Binary Search (MOBS) procedure. Six conditions were tested, two acceleration levels of 1 and 2 m/s2 to both left and right with, at the higher acceleration, two different times of visual motion presentation. Conditions were sequenced by means of a 6 x 6 Latin square balanced for order and carry over. A MANOVA did not show any statistically significant effects either for the independent variables acceleration, velocity, and direction of motion of the sled or for their interactions. The results obtained are in clear contrast to those obtained under rotatory stimulation. We conclude that the otolithic contribution to vestibular-visual motion processing is negligible. 相似文献
8.
A sensitive, specific high-performance liquid chromatographic procedure for the determination of prednisolone in plasma is described. The organic solvent extract from plasma is chromatographed on a silica gel column using a mobile phase of 0.2% glacial acetic acid, 6% ethanol, 30% methylene chloride in n-hexane on a high-performance liquid chromatograph fitted with an ultraviolet dector (254 nm). Quantitation of plasma samples containing 25 ng/ml prednisolone is reported. Metabolites and endogenous hydrocortisone do not interfere with prednisolone. The determination of prednisolone concentration in plasma following administration of a 10-mg single oral dose to a human subject is described. 相似文献
9.
H Tsuchiya M Sato H Kato T Okubo LR Juneja M Kim 《Canadian Metallurgical Quarterly》1997,703(1-2):253-258
Green tea extracts have been suggested to possess a preventive effect against dental caries. A quantitative method for their anticariogenic substances, catechins, was developed to evaluate their concentrations in human saliva after mouthrinsing with green tea extract. Salivary catechins were extracted to the organic phase after forming a complex with diphenylborate and an ion-pair with tetra-n-butylammonium, and then back-extracted to the acidic aqueous phase. The extract was analyzed by high-performance liquid chromatography using diode array detection at absorption wavelengths ranging from 269 to 278 nm. In reversed-phase chromatography by a gradient elution, eight catechins originating from green tea and an internal standard were separated in 15 min without interfering peaks. All the catechins were simultaneously and selectively determined in the concentration range 0.05-25.0 microg/ml. In replicate spiking experiments with standards, the mean recovery ranged between 86 and 99%, and both intra- and inter-assay C.V.s were within 2.3%. When mouthrinsing with an aqueous solution of green tea extract (5.0 mg/ml) containing eight catechins, the quantitative results revealed that each catechin was retained at microg/ml levels in saliva for up to 60 min. 相似文献
10.
A 62-year-old woman with pulmonary hypertension underwent mitral valve re-replacement through right thoracotomy. Severe adhesion occurred to the right lung. During pleural dissection the lung collapsed under single-lung ventilation, rapidly elevated pulmonary vascular resistance caused hemodynamic instability. When pulmonary hypertension is preoperatively present, this approach under single-lung ventilation is not recommended. 相似文献
11.
Determination of ivermectin in human plasma by high-performance liquid chromatography 总被引:1,自引:0,他引:1
A specific reversed-phase HPLC-assay with sensitive fluorometric detection has been developed to measure the potent new antiparasitic agent ivermectin (CAS 70288-86-7) in human plasma (and urine). The lower limit of the method was 1 ng/ml and the intra-/interassay variability averaged 4.5/6.9%, respectively. The assay was applied for measuring plasma (urine) concentrations of ivermectin upto 56 (72 h) following a single oral dose of 6 and 12 mg. No unchanged or conjugated ivermectin could be detected in urine. Plasma concentrations increased linearly with dose but elimination half-life (12.6/13.4 h) was independent of the administered dose. Thus, the method is applicable for monitoring plasma levels during clinical and pharmacokinetic trials with ivermectin to evaluate its most efficacious dosage regimen. 相似文献
12.
C Tharasse-Bloch P Brasseur L Favennec J Marchand 《Canadian Metallurgical Quarterly》1995,674(2):247-252
This is the 31st article in a continuing series of objectives to direct emergency medicine resident experiences on off-service rotations. Neck and torso trauma accounts for a large portion of injuries, and its management is an essential part of training in emergency medicine. Due to the often life-threatening presentations of trauma victims, resident instruction may be conducted at the bedside in difficult and demanding situations. Therefore, it is essential for residents to have specific goals and objectives to guide their acquisition of knowledge required to make critical decisions for patients with major trauma. 相似文献
13.
A sensitive and specific high-performance liquid chromatographic procedure for the determination of chlorpropamide or tolbutamide in plasma in the presence of their metabolites is described. The ether extract of acidified plasma is redissolved in the mobile phase, 17% acetonitrile in 0.05 M aqueous ammonium formate, and chromatographed on a reverse-phase column on a high-performance liquid chromatograph fitted with a UV absorbance detector. Quantitation of plasma samples containing less than 0.5 mug/ml of chlorpropamide and 5 mug/ml of tolbutamide is reported, using these drugs as mutual internal standards. The retention times of the metabolites are such that they do not interfere in the procedure. The assay method was tested in a human volunteer with both drugs and found suitable for single-dose pharmacokinetic studies. 相似文献
14.
I Rondelli F Mariotti D Acerbi E Redenti G Amari P Ventura 《Canadian Metallurgical Quarterly》1993,612(1):95-103
A high-performance liquid chromatographic method is described for the quantitation in plasma of the four stereoisomers of a new aminotetralin, (SRR, RSS)(SRS, RSR)-5,6-dimethoxy-2-[3'-(p-hydroxyphenyl)-3'-hydroxy-2'- propyl]aminotetralin (CHF 1255, internal code). After liquid-liquid extraction of the drug, separation was obtained after chiral derivatization with R-(+)-alpha-methylbenzyl isocyanate. The selective derivatization of the amino group was obtained by controlling the pH of the reaction medium at 7.5. The reaction was quantitative after a period of 16 h. The structures of the urea derivatives were confirmed by proton nuclear magnetic resonance spectroscopy and high-performance liquid chromatography with mass spectrometric detection. The use of an electrochemical detector, operating in the oxidative mode, allows the quantitation in plasma of all four urea derivatives at the nanogram level. The method was demonstrated to be precise, reproducible and applicable to pharmacokinetics studies after administration of the two epimeric racemates. 相似文献
15.
It has been suggested that GTS-21 can improve the learning deficits and inhibit the neuro-degeneration in patients with Alzheimer's disease. This paper describes a reversed-phase high-performance liquid chromatographic assay with visible detection at 405 nm for determination of GTS-21 and its metabolite, 4-hydroxy-GTS-21 in rat plasma. The method uses solid-phase extraction with a Bond Elut C18 column. A quantitation limit of 1.0 ng/ml was achieved using 0.5 ml of rat plasma. In the validation study, the coefficients of variation and the relative errors of each compound were less than 10%. Also freeze-thaw and storage stability were confirmed. This method has proved to be applicable to the pharmacokinetic study of GTS-21 in rats. 相似文献
16.
A sensitive and specific high-performance liquid chromatographic assay was developed for the simultaneous determination of p-aminohippuric acid (PAH), acetyl-p-aminohippuric acid (aPAH), and iothalamate in human plasma and urine. Plasma samples were prepared by protein precipitation with acetonitrile followed by evaporation, reconstitution in mobile phase, and injection onto a C18 reversed-phase column. Urine samples were diluted with 3 volumes of mobile phase prior to injection. Column effluent was monitored by UV detection at 254 nm. The lower limits of quantification in plasma were 0.5 mg/l for PAH and aPAH, and 1.0 mg/l for iothalamate. The within-day and between-day coefficients of variation in plasma and urine were < or =7.8% for all analytes. This method is well suited for renal function studies using iothalamate and PAH, whether administered as a bolus dose or by continuous infusion, to measure glomerular filtration rate and effective renal plasma flow, respectively. 相似文献
17.
Simultaneous determination of five macrolide antibiotics in meat by high-performance liquid chromatography 总被引:1,自引:0,他引:1
M Horie K Saito R Ishii T Yoshida Y Haramaki H Nakazawa 《Canadian Metallurgical Quarterly》1998,812(1-2):295-302
A simple and rapid method using high-performance liquid chromatography (HPLC) for the simultaneous determination of five macrolides (josamycin, kitasamycin, mirosamicin, spiramycin and tylosin) in meat has been developed. The drugs were extracted with 0.3% metaphosphoric acid-methanol (7:3, v/v), and the extracts were cleaned up on a Bond Elut SCX (500 mg) cartridge. The HPLC separation was performed on a Puresil 5C18 column (150 x 4.6 mm I.D.) with a gradient system of 0.025 M phosphate buffer (pH 2.5)-acetonitrile as the mobile phase at a flow-rate of 1.0 ml/min. The drugs were detected at 232 mn for josamycin, kitasamycin, mirosamicin and spiramycin, and 287 mn for tylosin. The calibration graphs were rectilinear from 2.5 to 100 ng for each drug. The recoveries at the level of 1.0 microgram/g were 70.8-90.4%, and detection limits were 0.05 microgram/g for each drug. 相似文献
18.
A simple qualitative and quantitative determination for pyridonecarboxylic acids including nalidixic acid (NA), oxolinic acid (OA) and pipemidic acid (PPA) in chicken plasma was carried out by microbiological, spectrophotometric, thin-layer chromatographic (TLC) and reverse-phase high-performance liquid chromatographic (HPLC) methods. As a test organism for bacteriological bioassay, Bacillus subtilis ATCC-6633 was the most sensitive of seven organisms investigated. Using the cup and the disc methods, a standard curve was obtained by determining the relationship between various drug concentrations and the diameter of the inhibition zone. The three drugs had two strong UV absorbance wavelengths (257 and 330 nm) on spectrophotometry. TLC analysis using a silica gel 60 F254 plate was investigated, and a solution of methanol:chloroform:acetic acid (3:1:1, v/v/v) was found to be the most suitable solvent for separation. The minimum concentration of drug detectable by this method was 0.5 microgram/ml for NA, 0.075 microgram/ml for OA and 0.39 microgram/ml for PPA. For HPLC analysis, a solution of acetonitrile:0.2 M phosphoric acid (1:1, v/v) was superior, and simultaneous determination of all three drugs was possible under the HPLC conditions used. The lowest measurable amount of drug in chicken plasma was 0.01 microgram/g. Recovery from extracts spiked with each drug at a known concentration was close to 100% for NA and OA, but only about 50% for PPA. 相似文献
19.
C Vandenbosch S van Belle M de Smet G Taton V Bruynseels G Vandenhoven DL Massart 《Canadian Metallurgical Quarterly》1993,612(1):77-85
A method was developed for the determination of (6R)- and (6S)-leucovorin and 5-fluorouracil in plasma. As leucovorin diastereoisomers cannot be separated on a classical reversed-phase column, it was necessary to use a chiral stationary phase. The method presented is based on the same principle as the method described by Wainer and Stiffin [J. Chromatogr., 424 (1988) 158], i.e., coupling of a bovine serum albumin phase to an achiral stationary phase. Before the chromatography, the drug was isolated from the plasma matrix by solid-phase extraction. For 5-fluorouracil, chromatography was performed on a classical RP-18 column after extraction from the plasma by liquid-liquid extraction. Both methods were validated and applied to the analysis of patients' samples. 相似文献
20.
T Yamamoto Y Moriwaki S Takahashi Z Tsutsumi J Yamakita Y Nasako K Hiroishi K Higashino 《Canadian Metallurgical Quarterly》1996,681(2):395-400
An assay for human plasma xanthine oxidase activity was developed with pterin as the substrate and the separation of product (isoxanthopterin) by high-performance liquid chromatography with a fluorescence detector. The reaction mixture consists of 60 microliters of plasma and 240 microliters of 0.2 M Tris-HCl buffer (pH 9.0) containing 113 microM pterin. With this assay, the activity of plasma xanthine oxidase could be easily determined despite its low activity. As a result, it could be demonstrated that the intravenous administration of heparin or the oral administration of ethanol did not increase plasma xanthine oxidase activity in normal subjects, and also that plasma xanthine oxidase activity was higher in patients with hepatitis C virus infection than in healthy subjects or patients with gout. In addition, a single patient with von Gierke's disease showed a marked increase in the plasma activity of this enzyme, relative to that apparent in normal subjects. 相似文献