共查询到20条相似文献,搜索用时 140 毫秒
1.
2.
3.
4.
5.
分别采用短时傅里叶变换和小波变换对雨刮直流电机的轴承异响和蜗轮蜗杆异响故障的振动和噪声信号进行了分析,得出了这两类故障的时频特性,为特征参数提取和实现故障诊断提供了直接依据。通过对比,初步验证了短时傅里叶分析和小波分析的正确性与适用性,发现小波分析更具有优势。 相似文献
6.
基于有限元分析和模态试验方法进行了智能四驱车辆分动器设计分析。首先将模态试验和有限元分析相结合,进行了分动器的模态
试验,并验证了模型的准确性;接着基于建立的分动器模型,利用Romax软件进行了不同工况下分动器壳体的轴承受力分析,加载更为精确的边界条件,进行了准确的分动器壳体的静力学和疲劳分析。实例分析结果表明,该款分动器在极限工况时的最大主应力达到196.8MPa,超出了材料的许用应力。对分动器结构进行了改进,通过改进前后的对照分析,发现改进后模型的应力和位移量明显减小,符合设计要求。 相似文献
7.
8.
9.
10.
11.
电感耦合等离子体质谱法(ICP-MS)测定运动员食品中铅、砷、镉、铜 总被引:9,自引:0,他引:9
以Sc、Ge、In、Bi作内标,采用电感耦合等离子体质谱法(ICP-MS)测定运动员食品中铅、砷、镉、铜。实验表明,方法的线性范围宽,线性相关系数均大于0.999。样品的加标回收率均在88.5%~107.5%,相对标准偏差均在5.0%之内。测定了GBW08503b、NBS1568、GBW08571标准参考物质中上述元素,测定值均在标准值范围内。该方法简单、快速、灵敏、准确,适用于运动员食品中铅、砷、镉、铜含量的分析。 相似文献
12.
To determine 17 elements in lung carcinomatous and pericarcinomatous tissues by inductively coupled plasma mass sepctrometry (ICP-MS), samples were digested using HNO3 and HClO4. Rhodium was used as an internal standard element. Reference materials of GBW(E)080193 Bovine Hepar and GBW09101 Human Hair were analyzed by the described method. The analytic values of two reference materials are accorded with the reference values. The recovery rates are 90%-110%. The precisions of the method are most below 10%. The concentrations of seventeen elements in lung carcinomatous and pericarcinomatous tissues are remarkable different. Seventeen elements in human lung tissue can be determined rapidly, simply, accurately by ICP-MS. 相似文献
13.
建立了电感耦合等离子体质谱法(ICP-MS)测定圆白菜标准物质中铅、镉、砷含量的分析方法。采用湿法消化和微波消解两种前处理方法,消解样品后对其进行了ICP-MS分析,在线内标溶液校正仪器的信号漂移,通过比较两种前处理方法对元素铅、镉、砷的测定结果分析显示,两种前处理方式测定值均在参考值范围内,无显著性差异,且相对标准偏差在0.41%~4.0%之间,测定结果准确可靠。湿法消化和微波消解两种前处理方式均可做为ICP-MS的前处理方法。 相似文献
14.
Techniques for semiquantitative analysis of solid materials by laser ablation (LA) sample introduction - inductively coupled plasma mass spectrometry (ICP-MS) are investigated. A 213nm laser efficiently ablates copper alloys. Ablated particulate material is transported by gas flow into an Agilent 7500ce ICP-MS. Quantitative analysis is obtained by internal standardization on either a known analyte or the sample matrix signal. The copper alloy samples are prepared for solution analysis subsequently. The analysis results by LA introduction mode and solution introduction mode are discussed. 相似文献
15.
16.
A new method for the analysis of trace kalium, calcium, iron and silicon in high purity tungsten with reaction cell ICP-MS was studied. The four elements such as K, Ca, Fe and Si can all suffer the polyatomic ions interference and have the high background concentration in general ICP-MS determination. Thus, the four elements cannot be determined directly with ICP-MS, if the interferences were not eliminated. The new technology (reaction cell ICP-MS) can clear the interferences and decrease the background concentration obviously. The trace K, Ca, Fe and Si in high tungsten were analyzed with this new technology, and the satisfied results were obtained. 相似文献
17.
2005~2016这十几年中,电感耦合等离子体质谱(ICP-MS)仪器的性能得到了大幅改善,其灵敏度最高可达106 cps/(1 μg/L, In),稳定性为1%~2%。多接收ICP-MS精密度的提高尤其显著,同位素测量精密度优于0.01%。各类ICP-MS普遍采用高速数据采集技术与数据库技术,使数据处理能力进一步加强。以三重四极杆和高分辨为代表的ICP-MS对基体干扰和多原子离子干扰消除能力进一步加强,绿色节能环保型和智能型ICP-MS也得到了关注。一些电离能较高的贵金属、类金属和非金属元素分析技术得到重视。以激光烧蚀(LA)、高效液相色谱(HPLC)、气相色谱(GC)、离子色谱(IC)、毛细管电泳(CE)、电热蒸发(ETV)和化学气体发生(CVG)为代表的联用技术及形态分析发展快速。单颗粒(SP)和单细胞(SC)等技术与ICP-MS的联用产生了以功能定义的专用ICP-MS,大大扩展了ICP-MS的应用领域。ICP-MS分析技术从传统的无机元素分析发展到有机生物及形态分析,从传统的样品消解后溶液进样分析发展到固体样品在线进样分析,从传统的元素含量分析发展到2D-3D成像分析和高精度同位素分析。ICP-MS在能源、地质、材料、环保、生物医学、食品、国土安全等诸多领域的应用进一步扩展,成熟的ICP-MS分析方法实现了标准化并得到推广和普及。本工作从6个方面总结回顾了2005~2016年间ICP-MS的重要进展,并对其发展前景进行了展望。 相似文献
18.
Simultaneously determination of 42 trace elements in varies plant reference materials by different digestion techniques ICP-MS was evaluated. The digestion techniques was compared with that using different reagents. Using of HF will improve recovery of the rare earth element and Be, Ti, Sb, U etc and the disadvantage is As, B, Hg will volatilize due to drive HF using HNO3. But it can be avoided with using nebulizer and spray chamber of resistant HF in ICP-MS. 相似文献
19.
ICP-MS相关联用技术在食品元素形态分析中的应用及进展 总被引:3,自引:0,他引:3
电感耦合等离子体质谱(ICP-MS)技术凭借其低检出限、多元素同时分析等优点,广泛应用于食品中的元素分析。随着分析技术的发展,以及元素的不同形态在物理、化学、营养、毒理等方面的显著差异,元素形态分析已经引起分析工作者的广泛关注。本工作对近年来ICP-MS技术与各种分离手段联用,在食品中砷、硒及锡等元素形态分析中的应用进行了综述,指出了ICP-MS 相关联用技术应用于食品元素形态分析时存在的问题,并对其未来的发展趋势进行了展望。 相似文献