首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The paper presents a comparative investigation of enhanced heat transfer and pressure loss by insertion of single twisted tape, full-length dual and regularly-spaced dual twisted tapes as swirl generators, in a round tube under axially uniform wall heat flux (UHF) conditions. The investigation encompassed the Reynolds number based on the inlet tube diameter (D) ranging from 4000 to 19,000. The experiments are performed using single twisted tapes and full-length dual twisted tapes with three different twist ratios (y/w = 3.0, 4.0 and 5.0) and also regularly-spaced dual twisted tapes with three different space ratios (s/D = 0.75, 1.5 and 2.25). The effects of major parameters on heat transfer and friction factor are discussed and the results from both single and dual twisted tape inserts are compared with those from the plain tube. The result shows that the heat transfer of the tube with dual twisted tapes is higher than that of the plain tube with/without single twisted tape insert. For both single twisted tape and full-length dual twisted tapes, Nusselt number (Nu) and friction factor (f) tend to increase with decreasing twist ratio (y/w). The average Nusselt number and friction factor in the tube fitted with the full-length dual twisted tapes at y/w = 3.0, 4.0 and 5.0, are respectively 146%, 135% and 128%; and 2.56, 2.17 and 1.95 times of those in the plain tube. For the regularly-spaced dual twisted tapes, the heat transfer rate is decreased with increasing space ratio (s/D). The average Nusselt numbers in the tube fitted with the regularly-spaced dual twisted tapes (s/D) of 0.75, 1.5 and 2.25 are respectively, 140%, 137% and 133% of that in the plain tube. With the similar trend mentioned above, all dual twisted tapes with free spacing yield lower heat transfer enhancement in comparison with the full-length dual twisted tapes (s/D = 0.0).  相似文献   

2.
Heat transfer in a solar water heater could be enhanced by means of twisted tapes, inserted inside the fluid flow tubes, which induce swirl flow and act as turbulence promoters. Experimental investigations for a solar water heater with twisted tape inserts having twist pitch to tube diameter ratio ranging from 3–12 have been carried out for varying mass flow rates. The results on heat transfer and friction data have been found to compare well with available results. Within the range of investigated parameters, the heat transfer in the twisted tape insert collectors has been found to increase by 18–70%, whereas the pressure drop increased by 87–132%, as compared to plane collectors. An expression correlating the Nusselt numbers in twisted tape and plane collectors, the twist pitch ratio has been developed in the form of Nus/Nu=1.3+2.88/y, which predicts the heat transfer within the range of the present investigation. Results conclude that such collectors would be preferable for higher grade energy collection as it is also at higher rate.Solar water heaters having twisted tape inserts inside the flow tubes perform better than the plane ones. It has been observed that heat losses are reduced (due to the lower value of the plate temperature) consequently increasing the thermal performance by about 30% over the plane solar water heaters under the same operating conditions. The effect of twisted-tape geometry, flow Reynolds number and intensity of solar radiation on the thermal performance of the solar water heater has been presented. It has been found that the twisted-tape collectors perform remarkably better in the lower range of flow Reynolds number (Re≈12,000), beyond which the increase in thermal performance is monotonous. It has also been found that such collectors might perform even better at higher values of intensity of solar radiation.  相似文献   

3.
Experiments to evaluate heat transfer coefficient and friction factor for flow in a tube and with twisted tape inserts in the transition range of flow with Al2O3 nanofluid are conducted. The results showed considerable enhancement of convective heat transfer with Al2O3 nanofluids compared to flow with water. It is observed that the equation of Gleninski applicable in transitional flow range for single-phase fluids showed considerable deviation when compared with values obtained with nanofluid. The heat transfer coefficient of nanofluid flowing in a tube with 0.1% volume concentration is 23.7% higher when compared with water at number of 9000. Heat transfer coefficient and pressure drop with nanofluid has been experimentally determined with tapes of different twist ratios and found to deviate with values obtained from equations developed for single-phase flow. A regression equation is developed to estimate the Nusselt number valid for both water and nanofluid flowing in the transition flow Reynolds number range in circular plain tube and with tape inserts. The maximum friction factor with twisted tape at 0.1% nanofluid volume concentration is 1.21 times that of water flowing in a plain tube.  相似文献   

4.
This work deals with the experimental investigation on Nusselt number, friction factor and thermal performance factor in a circular tube equipped with perforated twisted tape inserts with four different porosities of Rp = 1.6, 4.5, 8.9 and 14.7%. The experiments were conducted in a turbulent flow regime with Reynolds number ranging from 7200 to 49,800 using air as the working fluid under uniform wall heat flux boundary condition. The experimental results revealed that both heat transfer rate and friction factor of the tube fitted with perforated twisted tapes were significantly higher than those of the plain tube. Over the range investigated, Nusselt number, friction factor and thermal performance factor in the tube with perforated twisted tape inserts was found to be 110 –340, 110 –360 and 28–59% higher than those of the plain tube values, respectively. In addition, the empirical correlations of Nusselt number, friction factor and thermal performance factor were formulated from the experimental results of tape inserts.  相似文献   

5.
Heat exchangers have a wider scope in numerous applications, such as space heating, chemical industries, power stations, and so on. Due to heat loss and the thermal properties of the materials involved, the overall performance of a heat exchanger is questionable. Therefore, studies related to heat transfer techniques are appreciated in the research community. Thus, the present study numerically investigates the heat transfer performance of a horizontal heat pipe equipped with hexagonal perforated twisted tape inserts. Further, the numerical solutions of Nusselt number (Nu), friction factor (f), and thermal performance factor (TPF) are optimized with the help of response surface methodology (RSM). The parameters investigated in this study are Reynolds number (Re), which varies between 500 and 1500, input heat supply (Q) between 100 and 1000 W, and pitch ratio (3.2, 4, and 5.2). ANSYS fluid flow fluent was used to perform flow simulations for three different twisted tape inserts: horizontal, vertical, and alternate hexagon perforations. Optimum solutions are obtained at 1000 W heat supply, 1500 Re, and p/di = 4 from alternatively perforated twisted tape inserts. The optimum Nu, f, and TPF achieved are 119.545, 0.437, and 1.82, respectively. Also, the proposed RSM optimization method is evidenced with a maximum of 2.673% error during the confirmatory test.  相似文献   

6.
It is novel and better method that microencapsulated phase change material (MPCM) slurry and the tube with twisted tape inserts are adopted together to enhance convective heat transfer. In this paper, numerical analyses were carried out to study laminar heat transfer and friction characteristics of MPCM slurry in a circular tube with twisted tape inserts. It is found that the MPCM slurry in the tube with twisted tape insert leads to the best performance of convective heat transfer for the bigger apparent specific heat and the intensive swirl flow. Furthermore, the modified average Nusselt number increases with decreasing bulk Stefan number, twisted ratio and increasing Re, while the friction factor increases with increasing Re and decreasing twisted ratio. It is also found that the heat transfer enhanced efficiency increases with increasing Re and decreasing Steb, and the heat transfer enhancement effects of twisted tape for low Steb slurry are better than that for high Steb slurry. Moreover, the thermal-hydraulic performance ratios increase to a peak, then decrease gradually with increasing Re for different twist ratio. The performance ratio increases with decreasing the twist ratio only in a definite Re range, and the Re range decreases with decreasing twist ratio.  相似文献   

7.
通过模拟和实验的方法研究在湍流工况下(3 000Re10 000)换热器管内插入不同扭带模型后的传热特性和阻力特性。区别于传统螺旋扭带,提出一种顺时针与逆时针交替扭转的正反扭带。对不同扭率的传统扭带以及扭率为3的无缺口和半圆缺口正反转扭带进行模拟计算,并将模拟结果与实验结果进行对比验证。结果表明:在湍流流态下,雷诺数越小,扭带的强化换热效果表现越好;对不同扭率的扭带,其努塞尔数、摩擦系数和综合性能指标随扭率的减小而增大;扭率为3时,两种正反扭带的强化换热效果均优于传统扭带,无缺口正反扭带的换热效果最好;模拟计算的结果数据与实验结果数据比较,最大误差不超过8%。  相似文献   

8.
This article presents the computational fluid dynamic simulation of the heat transfer characteristics induced by a swap swirl air‐jet generator on the impingement surface. The study was carried out for conventional and swap twist tape inserts of twisted ratio y = 2.93 with various swap angles (α = 30°, 60°, 90°) at a constant distance of nozzle diameter impingement plate (L = 2D). The results show that the Nusselt number of the swirl impingement air‐jet depends on the twisted tape swap angles and airflow rate. The results also showed that the swap angle of 90° gave notable uniform local heat transfer distribution compared with the typical twist tape and other swap twist tapes (α = 30°, 60°). In addition, the predicted results of the local heat transfer coefficient help explain the local turbulence intensity and generation to assist the industrial applications of swirl impingement air‐cooling jet.  相似文献   

9.
The use of nanofluids and surface enhancers today are among the new technologies used to increase heat transfer. In this study, heat transfer phenomena in heat exchanger were investigated using Al2O3 nanoparticles and modified spiral band as flow turbulator. Results are verified with well‐known correlations. The results show that the tube with cross‐hollow twisted tape inserts has the best exergetic performance for different hollow widths of the tape. Clearance, which is defined as the width between the tube and twisted tape, also affects the heat transfer performance. The smaller the clearance, the better is the exergetic performance. The tube can achieve the best exergetic performance when the number of unilateral twisted tapes is four. The results showed that increasing nanofluid concentration improves exergetic performance.  相似文献   

10.
Turbulent convective heat transfer characteristics in a helical-ribbed tube fitted with twin twisted tapes have been investigated experimentally. The experiment was carried out in a double tube heat exchanger using the helical-ribbed tube having a single rib-height to tube-diameter ratio, e/DH = 0.06 and rib-pitch to diameter ratio, P/DH = 0.27 as the tested section. The insertion of the double twisted tapes with twist ratio, Y, in the range of 2.17 to 9.39 is to create vortex flows inside the tube. The inserted ribbed tube is arranged in similar directions of the helical swirl of the twisted tape and the helical rib motion of the tube (called co-swirl). Effects of the co-swirl motion of the ribbed tube and the double twisted tapes with various twist ratios on heat transfer and friction characteristics are examined. The results obtained from the ribbed tube and the twin twisted tape insert are compared with those from the smooth tube and the ribbed tube acting alone. The experimental results reveal that the co-swirling inserted tube performs much better than the ribbed/smooth tube alone at a similar operating condition. The co-swirl tube at Y ≈ 8 yields the highest thermal performance at lower Reynolds number (Re). In addition, the correlations of Nusselt number and friction factor as functions of Re, Pr and Y are also proposed.  相似文献   

11.
Introducing passive devices in the form of inserts helps to increase the heat transfer characteristics in a circular pipe. In the present work, the feasibility of using two twisted tapes has been numerically studied under laminar flow conditions. Two twisted tapes with configurations of co‐swirl and counter‐swirl conditions were simulated for Re ranging from 1000 to 2500. Heat transfer characteristics like Nusselt number, friction factor, and thermohydraulic performance index (THPI) were investigated. Even the effect of spacing of the tubes inside the pipe was numerically studied. Results indicated that the insertion of two tapes will improve the performance of the circular tube compared with a single tape in terms of a higher Nu and higher THPI. It is observed that for the co‐swirl condition for a Reynolds number of 1000, Nu and THPI is 38% and 29% higher than using a single tape, whereas, for the counter‐swirl condition, they are 43% and 34% higher than that of the single tape condition. Also, it is revealed that counter swirl positioning of the tape with an L/D ratio 0.56 outperformed all other configurations with the highest THPI.  相似文献   

12.
This work presents an experimental study on the mean Nusselt number, friction factor and enhancement efficiency characteristics in a round tube with short-length twisted tape insert under uniform wall heat flux boundary conditions. In the experiments, measured data are taken at Reynolds numbers in a turbulent region with air as the test fluid. The full-length twisted tape is inserted into the tested tube at a single twist ratio of y/w = 4.0 while the short-length tapes mounted at the entry test section are used at several tape length ratios (LR = ls/lf) of 0.29, 0.43, 0.57 and 1.0 (full-length tape). The short-length tape is introduced as a swirling flow device for generating a strong swirl flow at the tube entry before decaying along the tube. On the other hand, the full-length tape (LR = 1.0) is expected to produce a strongly swirling flow over the whole tube. The variation of heat transfer and pressure loss in the form of Nusselt number (Nu) and friction factor (f) respectively is determined and depicted graphically. The experimental result indicates that the short-length tapes of LR = 0.29, 0.43 and 0.57 perform lower heat transfer and friction factor values than the full-length tape around 14%, 9.5% and 6.7%; and 21%, 15.3% and 10.5%, respectively. In addition, it is apparent that the enhancement efficiency of the tube with the short-length tape insert is found to be lower than that with the full-length one. The mean deviation between measured and correlated values of the Nusselt number is in the order of ± 7% in the range of Reynolds numbers from 4000 to 20,000.  相似文献   

13.
In this paper, experimentally determined pressure drop and heat transfer characteristics of flow of water in a 75-start spirally grooved tube with twisted tape insert are presented. Laminar to fully turbulent ranges of Reynolds numbers have been considered. The grooves are clockwise with respect to the direction of flow. Compared to smooth tube, the heat transfer enhancement due to spiral grooves is further augmented by inserting twisted tapes having twist ratios Y ? 10.15, 7.95 and 3.4. It is found that the direction of twist (clockwise and anticlockwise) influences the thermo-hydraulic characteristics. Constant pumping power comparisons with smooth tube characteristics show that in spirally grooved tube with and without twisted tape, heat transfer increases considerably in laminar and moderately in turbulent range of Reynolds numbers. However, for the bare spiral tube and for spiral tube with anticlockwise twisted tape (Y = 10.15), reduction in heat transfer is noticed over a transition range of Reynolds numbers.  相似文献   

14.
The thermophysical properties like thermal conductivity and viscosity of Al2O3 nanofluid is determined through experiments at different volume concentrations and temperatures and validated. Convective heat transfer coefficient and friction factor data at various volume concentrations for flow in a plain tube and with twisted tape insert is determined experimentally for Al2O3 nanofluid. Experiments are conducted in the Reynolds number range of 10,000–22,000 with tapes of different twist ratios in the range of 0 < H/D < 83. The heat transfer coefficient and friction factor of 0.5% volume concentration of Al2O3 nanofluid with twist ratio of five is 33.51% and 1.096 times respectively higher compared to flow of water in a tube. A generalized regression equation is developed for the estimation of Nusselt number and friction factor valid for both water and nanofluid in plain tube and with inserts under turbulent flow conditions.  相似文献   

15.
The article presents the application of a mathematical model for simulation of the swirling flow in a tube induced by loose-fit twisted tape insertion. Effects of the clearance ratio defined as ratio of clearance between the edge of tape and tube wall to tube diameter (CR = c/D = 0.0 (tight-fit), 0.1, 0.2 and 0.3) on heat transfer enhancement (Nu), friction factor (f) and thermal performance factor (η) are numerically investigated for twisted tapes at two different twist ratios (y/w = 2.5 and 5.0). The simulation is conducted in order to gain an understanding of physical behavior of the thermal and fluid flow in the tube fitted with loose-fit twisted tape under constant wall temperature conditions in the turbulent flow regime for the Reynolds number ranging from 3000 to 10,000. The Navier–Stokes equation in common with a energy equation is solved using the SIMPLE technique with the standard kε turbulence model, the Renormalized Group (RNG) kε turbulence model, the standard kω turbulence model, and Shear Stress Transport (SST) kω turbulence model. The numerical results show that the predictions of heat transfer (Nu) and friction factor (f) based on the SST kω turbulence models are in better agreement with Manglik and Bergles [R.M. Manglik, A.E. Bergles, Heat transfer and pressure drop correlations for twisted-tape inserts in isothermal tubes, part II: Transition and turbulent flows, Transaction ASME, Journal of Heat Transfer, 115 (1993) 890–896.] than other turbulence models. The mean flow patterns in a tube with loose-fit twisted tapes in terms of contour plots of velocity, pathline, pressure, temperature and turbulent kinetics energy (TKE) are presented and compared with those in a tube fitted with tight-fit twisted tapes. It is visible that the twisted tape inserts for y/w = 2.5 with CR = 0.0 (tight-fit), 0.1, 0.2 and 0.3 can enhance heat transfer rates up to 73.6%, 46.6%, 17.5% and 20%, respectively and increase friction factors up to 330%, 262%, 189%, and 160%, respectively, in comparison with those of the plain tube. The tube with loose-fit twisted tape inserts with CR = 0.1, 0.2 and 0.3 provide heat transfer enhancement around 15.6%, 33.3% and 31.6% lower than those with CR = 0.0 (the tight-fit twisted tape). The heat transfer augmentation is expected to involve the swirl flow formation between the tape and a tube wall. In addition, the simulation for thermal performance factor (η) of a tube with the loose-fit twisted tape and the tight-fit twisted tape under the same pumping power is also conducted, for comparison.  相似文献   

16.
Turbulent convective heat transfer and friction factor characteristics of magnetic Fe3O4 nanofluid flowing through a uniformly heated horizontal circular tube with and without twisted tape inserts are estimated experimentally. Experiments are conducted in the particle volume concentration range of 0 < φ < 0.6%,twisted tape inserts of twist ratio in the range of 0 < H/D < 15and Reynolds number range of 3000 < Re < 22000. Heat transfer and friction factor enhancement of 0.6% volume concentration of Fe3O4 nanofluid in a plain tube with twisted tape insert of twist ratio H/D = 5 is 51.88% and 1.231 times compared to water flowing in a plain tube under same Reynolds number. Generalized regression equation is presented for the estimation of Nusselt number and friction factor for both water and Fe3O4 nanofluid in a plain tube and with twisted tape inserts under turbulent flow condition.  相似文献   

17.
Friction and compound heat transfer behaviors in a dimpled tube fitted with a twisted tape swirl generator are investigated experimentally using air as working fluid. The effects of the pitch and twist ratio on the average heat transfer coefficient and the pressure loss are determined in a circular tube with the fully developed flow for the Reynolds number in the range of 12,000 to 44,000. The experiments are performed using two dimpled tubes with different pitch ratios of dimpled surfaces (PR = 0.7 and 1.0) and three twisted tapes with three different twist ratios (y/w = 3, 5, and 7). Experiments using plain tube and dimpled tube acting alone are also carried out for comparison. The experimental results reveal that both heat transfer coefficient and friction factor in the dimpled tube fitted with the twisted tape, are higher than those in the dimple tube acting alone and plain tube. It is also found that the heat transfer coefficient and friction factor in the combined devices increase as the pitch ratio (PR) and twist ratio (y/w) decrease. In addition, an empirical correlation based on the experimental results of the present study is sufficiently accurate for prediction the heat transfer (Nu) and friction factor (f) behaviors.  相似文献   

18.
圆形流道内置扭带强化传热机理分析   总被引:1,自引:0,他引:1  
朱登亮  吴金星  张丽娜  魏新利 《节能技术》2006,24(5):402-404,418
为了分析圆形管道内置扭带的强化传热机理,用Fluent软件建立了其三维模型,模拟得到了管内流场和温度场,运用场协同原理证实了扭带强化传热的主要机理是扭带引起的螺旋流动使流体产生二次流,促进了主体流体和边界层流体的混合,提高了流场和温度场的协同性。分析了传热系数、压降与雷诺数及湍流动能的关系,提出应使换热器的湍流动能限制在一定的范围内,以获得较好的综合性能。  相似文献   

19.
Experimental investigation on heat transfer and friction factor characteristics of micro-finned tube fitted with full-length twisted tape and left–right twisted tape inserts of twist ratio 7.44, 8.27 and 11.17 has been presented. The experimental data obtained were compared with those obtained from plain tube published data. The heat transfer coefficient enhancement for left–right twisted inserts is higher than that for full-length twisted tape inserts for a given twist ratio. The empirical correlation for Nusselt number, friction relating Reynolds number and twist ratio was formed for both twisted tape inserts and left–right inserts and found to fit the experimental data within ±3.6% and ±2.5% for Nusselt number and ±7% and ±8.5% friction factor, respectively. Performance evaluation analysis was made and the maximum performance ratio was obtained for left–right twisted tape inserts.  相似文献   

20.
In this study, a numerical investigation for the fluid flow field analysis using different configuration dimple parameters in conjunction with an internal type insert in pipe is carried out. The effects of the dimple diameters with a center twisted tape on the flow pattern, pressure drop, friction factor, and heat transfer characteristics are investigated. The influence of the latter device on heat performance and thermal-hydraulic performance evaluation factor (PEF) were carried out in a pipe for fully developed flow with range for fully developed flow with range of Reynolds number (Re) of 1573 and 23 592. Experiments with numerical models are performed using different dimpled dimeters by inserting twisted tapes. The outcomes observe that the qualitative analysis for flow fields such as static pressure, dynamic pressure, velocity magnitude, wall shear stress, and turbulent kinetic energy as well as the quantities analysis for pressure drop, heat transfer coefficient friction factor, and Nu number in dimpled pipe fitted with twisted tape are greater than plain pipe. This is because using these devices cause more secondary flow, swirl flow, and flow mixing that lead to higher turbulence, which, in turn, enhance the overall heat transfer. The results indicated that the lower and higher values of thermal PEF are about 0.78 and 1.6, respectively, at the dimple dimmers of 1 mm.  相似文献   