This paper presents a methodology of a design optimization technique that can be useful in assessing the best configuration of a finned‐tube evaporator, using a thermoeconomic approach. The assessment has been carried out on a direct expansion finned‐tube evaporator of a vapor compression cycle for a roof‐top bus air‐conditioning (AC) system at a specified cooling capacity. The methodology has been conducted by studying the effect of some operational and geometrical design parameters for the evaporator on the entire cycle exergy destruction or irreversibility, AC system coefficient of performance (COP), and total annual cost. The heat exchangers for the bus AC system are featured by a very compact frontal area due to the stringent space limitations and structure standard for the system installation. Therefore, the current study also takes in its account the effect of the variation of the design parameters on the evaporator frontal area. The irreversibility due to heat transfer across the stream‐to‐stream temperature difference and due to frictional pressure drops is calculated as a function of the design parameters. A cost function is introduced, defined as the sum of two contributions, the investment expense of the evaporator material and the system compressor, and the operational expense of AC system that is usually driven by an auxiliary engine or coupled with the main bus engine. The optimal trade‐off between investment and operating cost is, therefore, investigated. A numerical example is discussed, in which a comparison between the commercial evaporator design and optimal design configuration has been presented in terms of the system COP and evaporator material cost. The results show that a significant improvement can be obtained for the optimal evaporator design compared with that of the commercial finned‐tube evaporator that is designed based on the conventional values of the design parameters. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

2.
A three‐effect heat pipe (heat pipe heating, heat pipe cooling and heat pipe heat recovery) adsorption refrigeration system using compound adsorbent (calcium chloride and activated carbon) was designed. The dynamic characteristics of mass and heat pipe heat recovery were studied. The results show that mass recovery and heat pipe heat recovery can improve (specific cooling power) SCP and (coefficient of performance) COP greatly. The averaged SCP of the cycle with mass recovery and the cycle without mass recovery is 502.9 W/kg and 436.7 W/kg at about 30 °C of cooling water temperature and ?15 °C of evaporating temperature. The corresponding COP is 0.27 and 0.24 respectively. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
In this study, superheating and sub‐cooling heat exchangers in vapor‐compressed refrigeration system are analyzed from thermodynamics and economical (refrigeration system operation cost, investment cost) viewpoints. Using four different refrigerants (R22, R502, R134a and R404a), the temperature of condenser at the interval of (35–55°C) and temperature of evaporator at the interval of (?10 to 10°C) have been obtained from the calculation process. The second law analysis (analysis of irreversibility) of a refrigeration system is carried out and then the whole system is optimized thermo‐economically. As a result of calculations, optimum superheating and sub‐cooling temperatures of heat exchanger (superheating, sub‐cooling) areas corresponding to these temperatures are obtained. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
《传热工程》2013,34(6):71-78
A new refrigeration system that uses a specially designed finned plate heat exchanger and works with zeolite and methanol is proposed. The integration of heat transfer and adsorption via a finned surface coated with zeolite CBV 901 and the use of a connected, twin active bed system to enable heat recuperation are novel features. The thermophysical properties of zeolite and methanol were first studied with the intention of designing a high performance heat exchanger (generator) for the adsorption refrigeration system. Here, the major problem is related to poor conductivity at the interface between the heat exchanger and the zeolite. The adsorbent must be heated (desorption phase) and then cooled (adsorption phase) back to ambient temperature in order to complete a thermodynamic cycle. To manufacture a sufficiently small system, there must be high rates of heat transfer in and out of the adsorbent. Therefore, the surface of the heat exchanger is finned in order to increase the heat transfer area (the fins are coated with 2 mm layer of specially prepared zeolite paste). The following characteristics were estimated from initial calculation: heating temperature, 120°C; outside tube temperature, 119.6°C; middle fin temperature, 117°C; and coated layer of zeolite paste temperature, 115.3°C. The mathematical code developed to calculate the effects of operating conditions and the Coefficient of Performance (COP) was presented at HPC 2001 in Paris. It is based on the Dubinin-Astakhov equation and thermodynamic analyses. The results obtained shows that 0.535 is the COP for a single bed and 0.925 for a double bed.  相似文献   

5.
A capillary tube‐based CO2 heat pump is unique because of the transcritical nature of the system. The transcritical cycle has two independent parameters, pressure and temperature, unlike the subcritical cycle. A comparative study for various operating conditions, based on system COP and exergetic efficiency, of a capillary tube and a controllable expansion valve‐based transcritical carbon dioxide heat pump systems for simultaneous heating and cooling at 73 and 4°C, respectively, is presented here. Two optimized capillary tubes having diameter of 1.5 and 1.6 mm are compared with an equivalent controllable throttle valve. Heat transfer and fluid flow effects are included in the gas cooler and evaporator model and capillary tube employs the homogeneous flow model to simulate two‐phase flow. Subcritical and supercritical thermodynamic and transport properties of CO2 are calculated employing a precision in‐house property code. Optimization of effective distribution of total heat exchanger area ratio between gas cooler and evaporator is investigated. The exergetic efficiency is better in case of the capillary tube than that of a controllable throttle valve‐based system. Capillary tube‐based system is shown to be quite flexible regarding changes in ambient temperature, almost behaving to offer an optimal pressure control just like the controllable expansion valve yielding both, maximum system COP and maximum exergetic efficiency. Relatively at a smaller diameter, the capillary tube exhibits better exergetic efficiency. Capillary tube length is the critical parameter that influences system optimum conditions. The exergy flow diagram exhibits that compressor, gas cooler and capillary tube contribute a larger share, in that order, to system irreversibility. It is fairly established in this study that a capillary tube can be a good engineering option for small capacity systems in lieu of an expansion valve, which has been thought of as the only possible solution to attain the pressure optimization, an important feature of all transcritical CO2 systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
M. Fatouh  E. Elgendy   《Energy》2011,36(5):2788-2795
The present work aims at evaluating the performance characteristics of a vapor compression heat pump (VCHP) for simultaneous space cooling (summer air conditioning) and hot water supply. In order to achieve this objective, a test facility was developed and experiments were performed over a wide range of evaporator water inlet temperature (14:26 °C) and condenser water inlet temperature (22:34 °C). R134a was used as a primary working fluid whereas water was adopted as a secondary heat transfer fluid at both heat source (evaporator) and heat sink (condenser) of the heat pump. Performance characteristics of the considered heat pump were characterized by outlet water temperatures, water side capacities and coefficient of performance (COP) for various operating modes namely: cooling, heating and simultaneous cooling and heating. Results showed that COP increases with the evaporator water inlet temperature while decreases as the condenser water inlet temperature increases. However, the evaporator water inlet temperature has more effect on the performance characteristics of the heat pump than that of condenser water inlet temperature. Actual COP of cooling mode between 1.9 to 3.1 and that of heating mode from 2.9 to 3.3 were obtained. Actual simultaneous COP between 3.7 and 4.9 was achieved.  相似文献   

7.
In this study, the effect of evaporator geometry on the loop thermosyphon's heat transfer coefficient is experimentally verified by using water as a working fluid with three filling ratios (50%, 70%, 90%), constant heat input (185 W), and condenser cooling water flow rate remaining constant at 2 Lpm. Three evaporator pipes are used (I: straight; II: helical coil evaporator with a diameter of 100‐mm coil and two turns; III: helical coil evaporator with a diameter of 50‐mm coil and four turns). From the experimental results, it can be observed that the performance of evaporator III is higher than the two other forms. A greater heat transfer coefficient value is found in case of type III evaporator and is equivalent to 2456 W/m2·°C. The maximum thermal resistance reduction occurs in the type III evaporator (37.32%), and the highest effective thermal conductivity for the same type is 6.123e + 05 W/m·°C. The experimental results demonstrate good agreement with the empirical equations.  相似文献   

8.
《Applied Thermal Engineering》2003,23(12):1453-1462
In this paper, the experiments are performed on an adsorption ice maker driven by waste heat, which uses up to two beds. Each bed uses methanol as refrigerant and solidified activated carbon (120 kg adsorbent totally, 60 kg adsorbent per bed) as adsorbent. This system is designed to be driven by the waste heat of a 100 kW diesel engine. The experiments show that the cooling power could be enhanced by the mass recovery process up to 11%, and the heating power could be lowered by the heat recovery process up to 30%. The optimal cooling power of this prototype is about 2.0 kW and corresponds to a specific cooling power (SCP) is about 17 W/kg with both heat and mass recoveries between two beds. Considering the optimal adsorption time is much longer than optimal desorption time at the condition of ice making, the experiments are operated on a single bed (60 kg adsorbent per bed) and the adsorption time used in experiments is two times of desorption time, then the performance of a three-bed adsorption ice maker (120 kg adsorbent totally, 40 kg adsorbent per bed) is predicted by the results of experiments on this single bed. The results of prediction show that both COP and cooling power of three-bed operation could be enhanced greatly compared to the two-bed operation; optimal SCP and COP are respectively 22 W/kg and 0.239 when mass and heat recoveries proceed between three beds. Optimal ice productivity of this three-bed system is 21 kg/h when the water temperature is 25 °C and ice temperature is −7 °C.  相似文献   

9.
Absorption refrigeration cycles are alternatives to conventional vapor‐compression cycles in which the energy required for refrigeration is provided by heat instead of mechanical work. In this paper, a novel refrigeration cycle utilizing the immiscible liquid‐phase separation behavior is simulated and analyzed using Aspen simulator. The two conjugate liquids adopted in this work are triethylamine (solute) and water (solvent). This binary system has a low critical solution temperature of 18 °C. The thermophysical properties of the binary mixture are generated using the universal functional activity coefficient (UNIFAC) and the nonrandom two‐liquid (NRTL) models. The phase splitting phenomenon at the generator temperature is predicted by both models. However, in comparison with the available experimental data for the same binary mixture, NRTL model gives better predictions for the flow rates and compositions of the material streams. Heat duties of the evaporator, absorber, and generator and the power consumption of the solution pump have been calculated using UNIFAC and NRTL models. The cycle COP that plays a major role in determining the cycle economical viability has been predicted for different operating conditions using the two models. Simulation results show that, for a waste heat reservoir at 60 °C and using NRTL model, the COP is about 2.0. Second law analysis conducted for all cycle components of the cycle shows that about 42% of the total exergy destructed occurs in the generator. Finally, the liquid‐phase separation refrigeration cycle is predicted to be a promising cycle in the near future because of hardware and energy savings. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
In this paper, the performance of the solar‐driven ejector air conditioning with several environment‐friendly working fluids is studied. The effect of the fluid nature and operating conditions on the ejector performance is examined. This performance is calculated using an empirical correlation. Thermodynamic properties of functioning fluids are obtained with a package REFPROP7. It appears that the refrigerant R717 offers the highest coefficient of performance (COP). For generator temperature TB = 90°C, condenser temperature TC = 35°C and evaporator temperature TE = 15°C and with R717, the COP of ejector air‐conditioning system is 0.408. Using a meteorological data for the city of Tunis, the system performance is computed for three collector types. The air‐conditioning season and period were taken for six months from April to September. The daily period is between 8 and 17 h. For the solar air‐conditioning application, the COP of the overall system varied from 0.21 to 0.28 and the exergy efficiency varied from 0.14 to 0.19 with the same working conditions and total solar radiation (351–875 Wm?2) in July. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

11.
This paper describes an experimental study of an ejector refrigeration cycle using R11 as the working fluid. The system was tested with boiler temperature from 100 to 110°C, the condenser temperature from 35 to 41°C, and the evaporator temperature up to 12°C. Two different mixing chambers with throat diameter of 8 mm were used. Choking of the fluid was always found in the first mixing chamber, but not in the second one. The system was more flexible to operate when there was no choking in the mixing chamber. A cooling temperature as low as ?5°C could be obtained with COP between 0.1 and 0.25 and cooling capacity between 500 and 1700 W. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

12.
A continuous heat recovery adsorption refrigerator using activated carbon-methanol has been developed. In this system, the heat source to drive the adsorption system can be controlled at a temperature from 60 °C to 110 °C, and the evaporating temperature can also be controlled at any requested value from 0 °C to 15 °C. To realize the operation performance of the system, many sensors of temperature, pressure and flow rate are installed in the adsorbers, the condenser and the evaporator. A lot of experiments have been completed in different operation conditions. Thus, by means of the experimental data, influences of the operating parameters, such as heat source temperature, evaporating temperature, cooling water temperature, cycle time and flow rate of throttling valve and so on, on p-t-x diagram of the cycle, specific cooling power (SCP) and coefficient of performance (COP) have been asserted. And causes of the influence are also analyzed. A series of conclusions are obtained.  相似文献   

13.
In this paper, an experimental performance evaluation of a direct expansion ground‐coupled heat pump (DX‐GCHP) system in heating mode is presented. The DX‐GCHP uses R134a as the refrigerant, and consists of three single U‐tube copper ground heat exchangers (GHEs) placed in three 30 m vertical boreholes. During the on–off operations from December 25, 2007, to February 6, 2008, the heat pump supplied hot water to fan‐coil at around 50.4°C, and its heating capacity was about 6.43 kW. The energy‐based heating coefficient of performance (COP) values of the heat pump and the whole system were found to be on average 3.55 and 3.28 at an evaporating temperature of 3.14°C and a condensing temperature of 53.4°C, respectively. The second law efficiency on the DX‐GCHP unit basis was around 0.36. The exergetic COP values of the heat pump and the whole system were obtained to be 0.599 and 0.553 (the reference state temperature was set equal to the average outdoor temperature of ?1.66°C during the tests), respectively. The authors also discussed some practical points such as the heat extraction rate from the ground, refrigerant charge and two possible new configurations to simultaneously deal with maldistribution and instability of parallel GHE evaporators. This paper may reveal insights that will aid more efficient design and improvement for potential investigators, designers and operators of such DX‐GCHP systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
In this study, a thermally driven adsorption cooling unit using natural zeolite–water as the adsorbent–refrigerant pair has been built and its performance investigated experimentally at various evaporator temperatures. The primary components of the cooling unit are a shell and tube adsorbent bed, an evaporator, a condenser, heating and cooling baths, measurement instruments and supplementary system components. The adsorbent bed is considered to enhance the bed’s heat and mass transfer characteristics; the bed consists of an inner vacuum tube filled with zeolite (zeolite tube) inserted into a larger tubular shell. Under the experimental conditions of 45 °C adsorption, 150 °C desorption, 30 °C condenser and 22.5 °C, 15 °C and 10 °C evaporator temperatures, the COP of the adsorption cooling unit is approximately 0.25 and the maximum average volumetric cooling power density (SCPv) and mass specific cooling power density per kg adsorbent (SCP) of the cooling unit are 5.2 kW/m3 and 7 W/kg, respectively.  相似文献   

15.
16.
The main objective of the present study is to investigate the performance characteristics of a solar‐assisted ground‐source heat pump system (SAGSHPS) for greenhouse heating with a 50 m vertical 1¼ in nominal diameter U‐bend ground heat exchanger. This system was designed and installed in the Solar Energy Institute, Ege University, Izmir (568 degree days cooling, base: 22°C, 1226 degree days heating, base: 18°C), Turkey. Based upon the measurements made in the heating mode, the heat extraction rate from the soil is found to be, on average, 54.08 Wm?1 of bore depth, while the required borehole length in meter per kW of heating capacity is obtained as 12.57. The entering water temperature to the unit ranges from 8.2 to 16.2°C, with an average value of 9.1°C. The greenhouse air is at a maximum day temperature of 25°C and night temperature of 14°C with a relative humidity of 40%. The heating coefficient of performance of the heat pump (COPHP) is about 2.13 at the end of a cloudy day, while it is about 2.84 at the end of sunny day and fluctuates between these values in other times. The COP values for the whole system are also obtained to be 5–15% lower than COPHP. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

17.
《Applied Thermal Engineering》2007,27(13):2195-2199
In this paper, a solid adsorption cooling system with silica gel as the adsorbent and water as the adsorbate was experimentally studied. To reduce the manufacturing costs and simplify the construction of the adsorption chiller, a vacuum tank was designed to contain the adsorption bed and evaporator/condenser. Flat-tube type heat exchangers were used for adsorption beds in order to increase the heat transfer area and improve the heat transfer ability between the adsorbent and heat exchanger fins. Under the standard test conditions of 80 °C hot water, 30 °C cooling water, and 14 °C chilled water inlet temperatures, a cooling power of 4.3 kW and a coefficient of performance (COP) for cooling of 0.45 can be achieved. It has provided a specific cooling power (SCP) of about 176 W/(kg adsorbent). With lower hot water flow rates, a higher COP of 0.53 can be achieved.  相似文献   

18.
This paper focuses on the novelty pumpless organic Rankine cycle (ORC) and its choice of working fluids. Based on the selection criteria, the refrigerant of R1233zd(E) is firstly chosen and investigated in the pumpless ORC system. In the system, the feed pump is removed, and the refrigerant flows back and forth between two heat exchangers, which act as the evaporator or condenser, respectively. The impacts of the heating water temperature and loads on the system performance are studied to find out the best operating conditions. The low‐grade heat source is simulated by an electric boiler. The temperature of the heat resource ranges from 80°C to 100°C with the interval of 5°C. The temperature of the cooling water inlet is 10°C and is kept constant. The largest average power output is 127 W under the condition of 100°C heating water with nine loads. Because the cycle efficiency with heating steam temperature of 100°C cannot be determined, the highest energy and exergy efficiencies are 3.5% and 17.1%, respectively, for heating water of 95°C with seven loads. The experimental results show that the energy and exergy efficiencies increase with the increase of the heating temperature. The power and current outputs increase when the loads increase under the condition of the constant heating water temperature, whereas the voltage output decreases meanwhile. The generating time increases when the loads increase. This phenomenon is mainly caused by the increasing evaporating pressure and decreasing condensing pressure when the loads increases.  相似文献   

19.
An ejector-compression heat pump can use low-grade thermal energy in the neighbourhood of 93.3°C (200°F) to provide space cooling and heating. This paper applies the existing ejector theory to estimate the performance of an ejector heat pump system at various operating conditions. The study includes parametric, sensitivity and off-design analyses of the heat pump performance. The performance enhancement options and desired ejector geometry are also examined. Refrigerants 11, 113 and 114 are three of the halocarbons most suitable for the ejector heat pump system. The estimated coefficients of performance for a simple ejector heat pump are 0.3 for the cooling mode and 1.3 for the heating mode at a sample operating condition in which the refrigerant (R-11) boiling temperature is 93.3°C (200°F), condensing temperature 43.3°C (110°F) and evaporating temperature 10°C (50°F). A 24 per cent performance improvement is predicted for a heat pump with two-stage ejectors and regenerative heat exchangers. The off-design performance is relatively insensitive to the evaporator temperature variations.  相似文献   

20.
In this paper, a multi‐purpose hybrid desiccant integrated vapor‐compression air‐conditioning system of a small capacity is experimentally investigated. The system, referred as hybrid desiccant‐assisted air conditioner (HDAC), is designed to meet the cooling load of spaces having large latent heat portions and at the same time to extract water from atmospheric air. The system is mainly consisted of a liquid‐desiccant dehumidification unit integrated with a vapor‐compression system (VCS). The dehumidification unit uses lithium chloride (LiCl) solution as the working material. The effect of different parameters, such as desiccant solution flow rate, process airflow rate, evaporator and condenser temperatures, strong solution concentration and regeneration temperature on the performance of the system, is studied. This system has a water recovery rate of 6.7 l/h TR (1.91 l/h kW) of pure water at typical north Egyptian climate (20–30°C dry bulb and 35–45% relative humidity). The HDAC system has a COP as high as 3.8 (an improvement of about 68% over the conventional VCS). The system offers a total cooling capacity of about 1.75 TR (6.15 kW) using a 0.75 TR (2.6 kW) VCS unit. Finally, the proposed system is found to have a payback time of about 10 months without any considerable extra capital cost compared with the known split air‐conditioning system. The results emphasize the potential benefits of the HDAC system. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   