首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cha W  Lee Y  Oh BK  Meyerhoff ME 《Analytical chemistry》2005,77(11):3516-3524
The direct amperometric detection of S-nitrosothiol species (RSNOs) is realized by modifying a previously reported amperometric nitric oxide gas sensor with thin hydrophilic polyurethane films containing catalytic Cu(II)/(I) sites. Catalytic Cu(II)/(I)-mediated decomposition of S-nitrosothiols generates NO(g) in the thin polymeric film at the distal tip of the NO sensor. Three different species are examined to create the catalytic layer: (1) a lipophilic Cu(II)-ligand complex; (2) Cu(II)-phosphate salt; and (3) small (3-microm) metallic Cu(0) particles. All three catalytic layers yield reversible amperometric response in proportion to the concentration of S-nitrosothiols (e.g., nitrosocysteine, nitrosoglutathione, S-nitroso-N-acetylcysteine, S-nitrosoalbumin) present in the aqueous test solution. Sensitivity toward the different RSNO species is dependent on the respective catalytic rates of decomposition of the RSNO species by reactive Cu(I), accessibility of the species into the polyurethane layer containing the catalyst, the level of reducing agents (ascorbate) used in solution to help generate reactive Cu(I) species, and the concentration of metal ion complexing agents present in the test solution (e.g., EDTA). Under optimized conditions, all RSNO species can be detected at < or =1 microM levels, with sensor lifetimes of at least 10 days for the sensors based on Cu(II)-phosphate and Cu0 particles. It is further shown that the new RSNO sensors can be used to assess the "NO-generating" ability of fresh blood samples by effectively detecting the total level of reactive RSNO species present in such samples.  相似文献   

2.
The development and in vivo analytical performance of a nitric oxide (NO)-releasing amperometric oxygen sensor with greatly enhanced thromboresistivity are reported. Gas permeable coatings formulated with cross-linked silicone rubber (SR) containing NO-generating compounds (diazeniumdiolates) are shown to release NO for extended periods of time (> 20 h) while reducing platelet adhesion and activation. Oxygen-sensing catheters prepared by dip-coating the NO-releasing films over the outer SR tubes of the implantable devices display similar analytical response properties in vitro (sensitivity, selectivity, response times) when compared to analogous sensors prepared without the NO release coatings. Superior analytical accuracy (relative to blood PO2 values measured in vitro) and greatly reduced thrombus formation on the outer surface of the sensors are observed in vivo (in canine model) with the NO release PO2 sensors compared to control sensors (without NO release) implanted simultaneously within the same animals. Based on these preliminary studies, the use of NO release polymers to fabricate catheter-style chemical sensors may be a potential solution to lingering biocompatibility and concomitant performance problems encountered when attempting to employ such devices for continuous intravascular measurements of blood gases and electrolytes.  相似文献   

3.
The concentration of S-nitrosothiols (RSNOs), endogenous transporters of the signaling molecule nitric oxide (NO), fluctuate greatly in physiology often as a function of disease state. RSNOs may be measured indirectly by cleaving the S-N bond and monitoring the liberated NO. While ultraviolet photolysis and reductive-based cleavage both decompose RSNOs to NO, poor selectivity and the need for additional reagents preclude their utility clinically. Herein, we report the coupling of visible photolysis (i.e., 500-550 nm) and amperometric NO detection to quantify RSNOs with greater selectivity and sensitivity. Enhanced sensitivity (up to 1.56 nA μM(-1)) and lowered theoretical detection limits (down to 30 nM) were achieved for low molecular weight RSNOs (i.e., S-nitrosoglutathione, S-nitrosocysteine) by tuning the irradiation exposure. Detection of nitrosated proteins (i.e., S-nitrosoalbumin) was also possible, albeit at a decreased sensitivity (0.11 nA μM(-1)). This detection scheme was used to measure RSNOs in plasma and illustrate the potential of this method for future physiological studies.  相似文献   

4.
Nitric oxide generation from porcine kidney slices is assessed using a new planar NO-selective amperometric sensor. The planar shape of the sensor allows for direct NO measurements near the surface (10 microm) of renal tissue slices in real time. Renal NO production may be modulated by the addition of L-arginine, arginine homopolymers (R2, R6, R10), and protamine, all of which can potentially transport across cellular membranes and provide a substrate for nitric oxide synthase within kidney parenchyma. Real-time amperometric measurements demonstrate that most L-arginine species can translocate across the cell membrane and rapidly increase NO production. However, no increase in NO generation is observed when the dimer of L-arginine (R2) is added to the solution bathing the tissue, suggesting that this species cannot permeate cell membranes. The degree of enhancement in NO generation observed for L-arginine and the larger peptides depends on the structure and follows the following sequence: R10 (decamer) > protamine > R6 (hexamer) > L-arginine. Protamine and the R10 decamer, especially, induce the largest increases in NO generation owing to their apparent rapid translocation into cells and subsequent cleavage by proteases to create high intracellular levels of L-arginine. The effect of sensor size (for sensor dimensions of 0.15- and 1-mm outer diameters) on the measured surface NO levels is also examined. The larger sensor traps more NO but hinders access of the L-arginine species to the tissue area between the flat distal plane of the sensor and the surface of the kidney slice. The use of such NO-generating peptides may be important in numerous biological systems that depend on NO production, such as ischemia-reperfusion injury and thrombogenesis.  相似文献   

5.
Oxygen sensors: Materials, methods, designs and applications   总被引:5,自引:0,他引:5  
Advancement of gas sensor technology over the past few decades has led to significant progress in pollution control and thereby, to environmental protection. An excellent example is the control of automobile exhaust emissions, made possible by the use of oxygen gas sensors. Since early 1970's there have been sustained studies on oxygen sensors and has led to development of sensors for various applications with varying performance characteristics. Solid electrolyte based potentiometric, amperometric and metal oxide based semiconducting resistive type sensors are used for high temperature applications. For solution-based pollution monitoring, dissolved oxygen sensors based on Clark electrodes have played a major role. More recently, for biological and medical applications, optical oxygen sensors are beginning to have an impact. In this review, we focus on both high temperature as well as dissolved oxygen sensors and compare the different methods of oxygen sensing, discuss underlying principles, and outline the designs and specific applications.  相似文献   

6.
Nitric oxide-selective sensors have been prepared with the heme domain of soluble guanylate cyclase (sGC), the only known receptor for signal transduction involving nitric oxide. Expressed in and purified from E. coli, the heme domain contains a stoichiometric amount of heme that has electronic and resonance Raman spectra almost identical to those of heterodimeric (native) sGC purified from bovine lung. The small size of the heme domain, its inability to bind oxygen, and its high affinity for nitric oxide make it well-suited for sensor applications. The heme domain has been labeled with a fluorescent reporter dye and changes in this dye's intensity are observed based on the sGC heme domain's characteristic binding of nitric oxide. The current sensors are prepared with 100-microns optical fiber but could also be prepared using submicrometer fiber tips. These sensors have fast, linear, and reversible responses to nitric oxide and are unaffected by numerous common interferents, such as oxygen, nitrite and nitrate. The sensor limit of detection is 1 microM nitric oxide. Glutathione has been shown to decrease the sensitivity of the sensor; however, the sensor response remains linear and can be calibrated on the basis of the glutathione concentration present in the biological environment of interest. The sensors have been used to measure extracellular nitric oxide production by BALB/c mouse macrophages. Minimal nitric oxide was produced by untreated cells, while high levels of nitric oxide were released from activated cells, e.g., 111 +/- 2 microM in a given cell culture.  相似文献   

7.
The in vivo biocompatibility and analytical performance of amperometric oxygen-sensing catheters prepared with a new type of nitric oxide (NO)-releasing silicone rubber polymer (DACA/N2O2 SR) is reported. The NO-release silicone rubber coating contains diazeniumdiolated secondary amine sites covalently anchored to a dimethylsiloxane matrix. Narrow diameter (0.9 mm, o.d.) silicone rubber tubing coated with this polymer can be employed to construct functional oxygen-sensing catheters that release NO continuously at levels > 1 x 10(-10) mol/cm2-min for more than 20 h. In vivo evaluation of such sensors within the carotid and femoral arteries of swine over a 16-h time period demonstrates that sensors prepared with the new NO-release coating exhibit no significant platelet adhesion or thrombus formation, but control sensors (non-NO release) implanted within the same animals do show a high propensity for cell adhesion and bulk clot formation. Furthermore, the in vivo analytical data provided by sensors fabricated with NO-release coatings (N = 9) are shown to be statistically equivalent to PO2 levels measured in vitro on discrete samples of blood. Control sensors (N = 9) placed within the same animals yield average PO2 values that are statistically different (p < or = 0.05) (lower) from both the levels measured on discrete samples and those provided by the NO-release sensors over a 16-h in vivo monitoring period.  相似文献   

8.
An amperometric fluorinated xerogel-derived nitric oxide (NO) microelectrode is described. A range of fluorine-modified xerogel polymers were synthesized via the cohydrolysis and condensation of alkylalkoxy- and fluoroalkoxysilanes. Such polymers were evaluated as NO sensor membranes to identify the optimum composition for maximizing NO permeability while providing sufficient selectivity for NO in the presence of common interfering species. By taking advantage of both the versatility of sol-gel chemistry and the "poly(tetrafluoroethylene)-like" high NO permselective properties of the xerogels, the performance of the fluorinated xerogel-derived sensors was excellent, surpassing all miniaturized NO sensors reported to date. In contrast to previous electrochemical NO sensor designs, xerogel-based NO microsensors were fabricated using a simple, reliable dip-coating procedure. An optimal permselective membrane was achieved by synthesizing xerogels of methyltrimethoxysilane (MTMOS) and 20% (heptadecafluoro-1,1,2,2-tetrahydrodecyl)trimethoxysilane (17FTMS, balance MTMOS) under acid-catalyzed conditions. The resulting NO microelectrode had a conical tip of approximately 20 microm in diameter and approximately 55 microm in length and exhibited sensitivities of 7.91 pA x nM (-1) from 0.2 to 3.0 nM (R (2) = 0.9947) and 7.60 nA x microM (-1) from 0.5 to 4.0 microM ( R (2) = 0.9999), detection limit of 83 pM (S/ N = 3), response time ( t 95%) of <3 s, and selectivity (log K NO, j (amp)) of -5.74, <-6, <-6, <-6, <-6, -5.84, and -1.33 for j = nitrite, ascorbic acid, uric acid, acetaminophen, dopamine, ammonia/ammonium, and carbon monoxide. In addition, the sensor proved functional up to 20 d, maintaining >or=90% of the sensor's initial sensitivity without serious deterioration in selectivity.  相似文献   

9.
Ratiometric and lifetime-based sensors have been designed for cellular detection of nitric oxide. These sensors incorporate cytochrome c', a hemoprotein known to bind nitric oxide selectively. The cytochrome c' is labeled with a fluorescent reporter dye, and changes in this dye's intensity or fluorescence lifetime are observed as the protein binds nitric oxide. The ratiometric sensors are composed of dye-labeled cytochrome c' attached to the optical fiber via colloidal gold, along with fluorescent microspheres as intensity standards. These ratiometric sensors exhibit linear response, have fast response times (< or = 0.25 s), and are completely reversible. The sensors are selective over numerous common interferents such as nitrite, nitrate, and oxygen species, and the limit of detection is 8 microM nitric oxide. The lifetime-based measurements are made using free, dye-labeled cytochrome c' in solution and have a limit of detection of 30 microM nitric oxide. The use of these two techniques has allowed measurement of intra- and extracellular macrophage nitric oxide. Employing the ratiometric fiber sensors gave a multicell culture average extracellular nitric oxide concentration of 210 +/- 90 microM for activated macrophages, while an average intracellular concentration of 160 +/- 10 microM was determined from the lifetime-based measurements of dye-labeled cytochrome c' in the macrophage cytosol. Microscopic adaptation of the lifetime-based methods described here would allow direct correlation of intracellular nitric oxide levels with specific cellular activities, such as phagocytosis.  相似文献   

10.
The valence and oxygen defect properties of cerium oxide nanoparticles (nanoceria) suggest that they may act as auto‐regenerative free radical scavengers. Overproduction of the free radical nitric oxide (NO) by the enzyme inducible nitric oxide synthase (iNOS) has been implicated as a critical mediator of inflammation. NO is correlated with disease activity and contributes to tissue destruction. The ability of nanoceria to scavenge free radicals, or reactive oxygen species (ROS), and inhibit inflammatory mediator production in J774A.1 murine macrophages is investigated. Cells internalize nanoceria, the treatment is nontoxic, and oxidative stress and pro‐inflammatory iNOS protein expression are abated with stimulation. In vivo studies show nanoceria deposition in mouse tissues with no pathogenicity. Taken together, it is suggested that cerium oxide nanoparticles are well tolerated in mice and are incorporated into cellular tissues. Furthermore, nanoceria may have the potential to reduce ROS production in states of inflammation and therefore serve as a novel therapy for chronic inflammation.  相似文献   

11.
An improved miniature amperometric nitric oxide sensor design with a planar sensing tip (ranging from 150 microm to 2 mm in diameter) is reported. The sensor is fabricated using a platinized platinum anode and a Ag/AgCl cathode housed behind a microporous poly(tetrafluoroethylene) (PTFE; Gore-tex) gas-permeable membrane. Platinization of the working platinum electrode surface dramatically improves the analytical performance of the sensor by providing approximately 10-fold higher sensitivity (0.8-1.3 pA/nM), approximately 10-fold lower detection limit (< or =1 nM), and extended (at least 3-fold) stability (>3 d) compared to sensors prepared with bare Pt electrodes. These improvements in performance arise from increasing the kinetics and lowering the required potential for the 3-electron oxidation of NO to nitrate, relative to that observed using a nonplatinized working electrode. The outer porous PTFE membrane provides complete selectivity for NO over nitrite ions (up to 10 mM nitrite). The new sensor is applied for surface measurements of NO released from diazeniumdiolate-loaded silicone rubber films (SR-DACA-6/N(2)O(2)). The effects of sensor size (for sensor dimensions of 0.15-, 1-, and 2-mm o.d.) and the distance of the sensor from the surface of the NO-emitting polymer film are investigated via experiments as well as theoretical calculations. A significant analyte trapping effect is demonstrated, the degree of which depends on the sensor size and its distance from the surface. It is further demonstrated that surface NO concentrations for fresh SR-DACA-6/N(2)O(2) loaded films are also influenced by the polymer film thickness, with thicker films generating higher surface concentrations of NO.  相似文献   

12.
Catalytic generation of nitric oxide (NO) from NO donors by nanomaterials has enabled prolonged NO delivery for various biomedical applications, but this approach requires laborious synthesis routes. In this study, a new class of materials, that is, polymeric amines including polyethyleneimine (PEI), poly-L-lysine, and poly(allylamine hydrochloride), is discovered to induce NO generation from S-nitrosothiols (RSNOs) at physiological conditions. Controlled NO generation can be readily achieved by tuning the concentration of the NO donors (RSNOs) and polymers, and the type and molecular weight of the polymers. Importantly, the mechanism of NO generation by these polymers is deciphered to be attributed to the nucleophilic reaction between primary amines on polymers and the SNO groups of RSNOs. The NO-releasing feature of the polymers can be integrated into a suite of materials, for example, simply by embedding PEI into poly(vinyl alcohol) (PVA) hydrogels. The functionality of the PVA/PEI hydrogels is demonstrated for Pseudomonas aeruginosa biofilm prevention with a ≈ 4 log reduction within 6 h. As NO has potential therapeutic implications in various diseases, the identification of polymeric amines to induce NO release will open new opportunities in NO-generating biomaterials for antibacterial, antiviral, anticancer, antithrombotic, and wound healing applications.  相似文献   

13.
Wang Z  Lin P  Baker GA  Stetter J  Zeng X 《Analytical chemistry》2011,83(18):7066-7073
A simple Clark-type online electrochemical cell design, consisting of a platinum gauze working electrode and incorporating ionic liquids (IL) as electrolytes, has been successfully applied for the amperometric sensing of oxygen. Studying ILs comprising the bis(trifluoromethylsulfonyl)imide anion, the obtained analytical parameters were found to be strongly dependent on the choice of cation. Compared with a conventional Clark cell design based on an aqueous supporting electrolyte, the modified oxygen sensor achieves substantial improvements in performance and stability. A limit of detection for oxygen as low as 0.05 vol?%, linearity over an oxygen partial pressure between 0% and 20%, and a steady-state response time of 2 min was demonstrated, with a stable analytical response shown over the examined period of 90 days with no obvious fouling of the electrode surface. Based on the attractive physical attributes of ionic liquids (e.g., thermal stability beyond 150 °C), one can envision intriguing utility in nonstandard conditions and long-term online applications, as well as extension to the determination of other gases, such as methane and nitric oxide.  相似文献   

14.
The in vitro analytical performance of fluorescence-based oxygen sensing polymeric films prepared with silicone rubbers that spontaneously release nitric oxide (NO) is examined. The use of NO-release polymers for fabricating functional optical sensors is proposed as a potential solution to fingering biocompatibility and concomitant performance problems encountered with prototype intravascular optical oxygen sensors. Plasticized silicone rubber films formulated with two distinct types of diazeniumdiolate NO donors release NO for more than 24 h. The optical oxygen sensing films prepared by doping these NO release polymeric materials with oxygen indicators (pyrene/perylene donor/acceptor pair) display different analytical responses, as compared to controls without NO release capability. Nonlinear Stern-Volmer behavior is observed for single-layer NO release oxygen sensors owing to heterogeneous environments for the pyrene/perylene pair and a concomitant quenching of the fluorescence by excess amine sites in such films. In contrast, a dual-layer configuration using an underlying NO-release silicone rubber layer covered with a second polymeric layer containing the fluorescent indicators is shown to yield identical sensitivity and linearity toward oxygen as conventional non-NO-releasing oxygen sensing films, while still providing surface NO fluxes necessary to yield more thromboresistive devices.  相似文献   

15.
Chen Z  Li Q  Sun Q  Chen H  Wang X  Li N  Yin M  Xie Y  Li H  Tang B 《Analytical chemistry》2012,84(11):4687-4694
Determination of intracellular bioactive species will afford beneficial information related to cell metabolism, signal transduction, cell function, and disease treatment. In this study, the first application of a microchip electrophoresis-laser-induced fluorescence (MCE-LIF) method for concurrent determination of reactive oxygen species (ROS) and reactive nitrogen species (RNS), i.e., superoxide (O(2)(-?)) and nitric oxide (NO) in mitochondria, was developed using fluorescent probes 2-chloro-1,3-dibenzothiazolinecyclohexene (DBZTC) and 3-amino,4-aminomethyl-2',7'-difluorescein (DAF-FM), respectively. Potential interference of intracellular dehydroascorbic acid (DHA) and ascorbic acid (AA) for NO detection with DAF-FM was eliminated through oxidation of AA with the addition of ascorbate oxidase, followed by subsequent MCE separation. Fluorescent products of O(2)(-?) and NO, DBZTC oxide (DBO), and DAF-FM triazole (DAF-FMT) showed excellent baseline separation within 1 min with a running buffer of 40 mM Tris solution (pH 7.4) and a separating electric field of 500 V/cm. The levels of DBO and DAF-FMT in mitochondria isolated from normal HepG2 cells and PC12 cells were evaluated using this method. Furthermore, the changes of DBO and DAF-FMT levels in mitochondria isolated from apoptotic HepG2 cells and PC12 cells could also be detected. The current approach was proved to be simple, fast, reproducible, and efficient. Measurement of the two species with the method will be beneficial to understand ROS/RNS distinctive functions. In addition, it will provide new insights into the role that both species play in biological systems.  相似文献   

16.
A xerogel-based optical pH sensor capable of releasing low levels of nitric oxide (NO) and measuring changes in solution pH is reported. Through simple dip-coating procedures, aminoalkoxysilane-based xerogel films modified with N-diazeniumdiolate NO donor precursors and the fluorescent pH indicator seminaphthorhodamine-1 carboxylate (SNARF-1) were sequentially deposited onto optical fibers. The resulting sensors were characterized by fast and linear response to pH throughout the physiological range (pH 7.0-7.8). Real-time chemiluminescence measurements confirmed that the presence of the overlying SNARF-1-containing TMOS layer did not have an inhibitory effect on N-diazeniumdiolate formation or NO release, and the NO-releasing coatings were capable of maintaining NO fluxes >0.4 pmol/cm(2) s up to 16 h. In vitro blood compatibility studies using porcine platelets confirmed the expected thromboresistivity of the NO-releasing xerogel coatings.  相似文献   

17.
An amperometric sol-gel derived nitric oxide microsensor is described. Several silicon-based xerogel membranes are evaluated to identify the optimum composition for maximizing NO permeability while providing sufficient selectivity for NO in the presence of common interfering species. Xerogel permeability and selectivity are further manipulated as a function of reaction/processing conditions. In addition, the effects of incorporating Nafion into the xerogel matrix on sensor performance and the stability of the ensuing xerogel/Nafion hybrid film are evaluated. The optimal permselective membrane is achieved by catalyzing polycondensation of the xerogel composed of methyltrimethoxysilane and (aminoethylaminomethyl)phenethyltrimethoxysilane and Nafion with NO gas. The resulting NO microsensor exhibits a sensitivity of 0.17 +/-0.02 pA/nM (from 25 to 800 nM, r = 0.9991), detection limit of 25 nM (S/N = 3), response time of 9 s (t(95%), a NO concentration change from 400 to 500 nM), selectivity (log K(NOj) amp) of -5.8, <-6, <-6, and <-6 for j = nitrite, ascorbic acid, uric acid, and acetaminophen, and a lifetime of 8 d (82% of initial sensitivity without serious deterioration in selectivity).  相似文献   

18.
Wet ammonia desulphurization process can be retrofitted for combined removal of SO2 and NO from the flue gas by adding soluble cobalt(II) salts into the aqueous ammonia solutions. The Co(NH3)6(2+) formed by ammonia binding with Co2+ is the active constituent of scrubbing NO from the flue gas streams. A stirred vessel with a plane gas-liquid interface was used to measure the chemical absorption rates of nitric oxide into the Co(NH3)6(2+) solution under anaerobic and aerobic conditions separately. The experiments manifest that the nitric oxide absorption reaction can be regarded as instantaneous when nitric oxide concentration levels are parts per million ranges. The gas-liquid reaction becomes gas film controlling as Co(NH3)6(2+) concentration exceeds 0.02 mol/l. The NO absorption rate is proportional to the nitric oxide inlet concentration. Oxygen in the gas phase is favorable to the absorption of nitric oxide. But it is of little significance to increase the oxygen concentration above 5.2%. The NO absorption rate decreases with temperature. The kinetic equation of NO absorption into the Co(NH3)6(2+) solution under aerobic condition can be written as.  相似文献   

19.
Various innovative chemical sensors have been developed in recent years to sense dangerous substances in air and trace biomarkers in breath. However, in order to solve real world problems, the sensors must be equipped with efficient sample conditioning that can, e.g., control the humidity, which is discussed much less in the literature. To meet the demand, a miniaturized mouthpiece was developed for personal breath analyzers. A key function of the mouthpiece is to condition the humidity in real breath samples without changing the analyte concentrations and introducing substantial backpressure, which is achieved with optimized packing of desiccant particles. Numerical simulations were carried out to determine the performance of the mouthpiece in terms of various controllable parameters, such as the size, density, and geometry of the packing. Mouthpieces with different configurations were built and tested, and the experimental data validated the simulation findings. A mouthpiece with optimized performance reducing relative humidity from 95% (27?000 ppmV) to 29% (8000 ppmV) whereas retaining 92% nitric oxide (50 ppbV to 46 ppbV) was built and integrated into a hand-held exhaled nitric oxide sensor, and the performance of exhaled nitric oxide measurement was in good agreement with the gold standard chemiluminescence technique. Acetone, carbon dioxide, oxygen, and ammonia samples were also measured after passing through the desiccant mouthpiece using commercial sensors to examine wide applicability of this breath conditioning approach.  相似文献   

20.
Lee Y  Kim J 《Analytical chemistry》2007,79(20):7669-7675
A planar-type amperometric dual microsensor for simultaneous detection of nitric oxide and carbon monoxide is presented. The sensor consists of a dual platinum microdisk-based working electrode (WE) and a Ag/AgCl counter/reference electrode covered with an expanded poly(tetrafluoroethylene) (Tetra-tex) gas-permeable membrane. The dual WE possesses two different platinized platinum disks (WE1 and WE2, 250 and 25 microm in diameter, respectively). The larger WE1 is further modified with electrochemical deposition of tin. Use of two sensing disks different in their size as well as in their surface modification produces apparently different sensitivity ratios of NO to CO at WE1 and at WE2 (approximately 2 and approximately 10, respectively) that are induced by favorable CO oxidation on the surface of tin versus platinum. Anodic currents independently measured at WE1 and at WE2 are successfully converted to the concentrations of NO and CO in the co-presence of these gases using the differentiated sensitivities at each electrode. The sensor is evaluated in terms of its analytical performance: respectable linear dynamic range (sub nM to microM); low detection limit (approximately 1 nM for NO and <5 nM for CO); selectivity (over nitrite up to approximately 1 mM); and sensitivity (sufficient for analyzing physiological levels of NO and CO). Using the NO/CO dual microsensor, real-time, simultaneous, direct, and quantitative measurements of NO and CO generated from living biological tissue (mouse, c57, kidney) surfaces, for the first time, are reported.  相似文献   