Kinetic equations for ozone absorption rate present in the model were derived from the application of film theory to an irreversible gas-liquid reaction. Parameters involved in the model, reaction rate and mass transfer coefficients, Henry's law constant, etc., were estimated from bench-scale experiments. The model was applied to ozonation in bubble contactors of height/diameter ratio equal to that of the bench scale contactor and to a pilot plant bubble column of a height/diameter ratio about 3.6 times higher. 相似文献
The effect of ozonation on membrane flux was found to be largely dependent on raw water quality as well as ozone dose. In case of upstream water (A), preozonation achieved significant flux enhancement regardless of ozone dose. Whereas, for the downstream water (B), the steady state flux was increased or decreased depending on ozone dose.
The analysis based on the resistance-in-series model provided the mechanistic interpretation on the membrane flux variation. Ozonation in an ozone-ultrafiltration system always brought about a decrease in cake resistance (Rc) and an increase in fouling resistance (Rf). Based on the measurement of particle size distribution and zeta potential, the reduction in cake resistance through ozonation was attributed to an increase in particle size due to “ozone-induced particle destabilization”. However, the increase in the fouling resistance seems to be caused partly by the microbial characteristics of raw water.
Although there was little effect on TOC, ozone-UF treatment could get much higher removal of UV 254, THMFP (lday) and THMPF/TOC ratio than UF treatment alone. 相似文献
It has been indicated that the removal of the five species of aromatic nitro compounds by ozonation can well be expressed mathematically by first order reaction equations. Besides, the reaction constants and half-life periods for various species of the tested nitro compounds were calculated at different temperatures and pH.
An ozonation effect index (OI) was developed in the study to express the degree of degradation of substrates by ozonation, by means of which the five aromatic nitro hydrocarbons were compared with each other and finally ranked in the following order from greatest to smallest degrees of degradation:
p-nitroaniline > nitrobenzene > p-dinitrobenzene > p-nitrotoluene > m-dinitrobenzene
It has also found that the CODm/M ratio increases with ozone doses. This means that some easily degradable intermediates are produced, and increase in concentration with increase of ozone dose in the ozonation process.
The mechanisms of removing the five aromatic nitro hydrocarbons are discussed from the viewpoint of orienting effects of substituent groups on the aromatic rings. 相似文献
The direct reaction between substrates and ozone predominated at lower pH, which resulted in the efficient oxidation of the olefin, DCPE. At higher pH, ozonation resulted in more efficient oxidation of the chlorinated alkanes, with a corresponding decrease in the efficiency of DCPE oxidation. Consistent results were observed for ozone/H2O2 and ozone/UV treatment. Due to slow UV-induced decomposition of H2O2, the process using H2O2/UV (254 nm) resulted in very slow oxidation of all four compounds.
The total ozone requirement to achieve a given degree of elimination (to 37% of the original concentration), δ0.37, was used to assess the combined effects of the direct and indirect reactions for different types of waters. 相似文献
A study of ozone efficiency and yield concerning the reduction of TOC and COD levels is presented. The biological degradability.of treated water is discussed. A design and rating calculation procedure for countercurrent contactors is presented. Various waste treatment strategies using separation processes and ozone are discussed briefly. A cost estimate to treat a typical dye effluent in two stages on industrial scale is included. 相似文献
The study of the interactions between those reactants has been made according to the following main topics :
As for THM formation, experiments conducted on simple organic compounds or on natural fulvic acids show important decreases in THM or TCAA formation after ozonation. It may be noticed, however, that the ozonation of surface waters may induce the formation of haloform precursors, usually with a low level of reactivity.
In water supplies containing bromide ions, oxidation of the latter through hypobromous acid may take place during the ozonation stage. Failing preozonation treatment, hypobromous acid is generated very rapidly during chlorination, thus inducing the formation of chloro- brominated organic compounds.
During the ozonation of fulvic acid solutions, the presence of small amounts of bicarbonate was found to improve precursor removal significantly.
It can be concluded that the partial analogy of the action of ozone or chlorine on aromatic structures, whether simple or complex (such as humic and fulvic acids), seems to indicate that the consequence of preozonation is the destruction, at least in part, of the most reactive sites for THM production, thus leading to a decrease of the volatile organochlorinated compounds formed during the post-chlorination. However, some ozonation products of natural waters are THM precursors, though of low reactivity. Then, in the presence of bromide ions, the formation of volatile organobrominated compounds may be observed during ozonation. 相似文献
Abbreviations: Recirculating Aquaculture Systems (RAS); Advanced Oxidation Processes (AOPs) 相似文献
The batch reactor designed for the studies consisted of a cylindrical section for holding effluent, and a top spherical section for ozone/oxygen mixture. The reactor proved to be effective for controlling ozone dose. The variation in the applied ozone dose was less than 5 mg/L.
Bleach and primary effluents were treated with 50 and 100 mg/L ozone doses. Duplicate experiments were conducted for these effluents. Secondary effluent was studied for 50,100,150 and 200 mg/L ozone doses. Six replicate experiments were conducted for 50 and 100 mg/L ozone doses, whereas two experiments were carried out for 150 mg/L and one experiment for 200 mg/L ozone dose.
The results were analyzed using 't' test for paired experiments and ANOVA table for statistical confirmation. Residuals were plotted to check the assumptions of constant variance and normal distribution. The results indicated that 50 and 100 mg O3/L effectively removed color from bleach effluent and primary effluent, but did not significantly change the BOD. Ozone was found to be effective for secondary effluent, as BOD5 was increased by 65% for 50 and 100% for 100 mg O3/L doses. The corresponding reduction in color was 62% and 82%, respectively. Ke and Lo values for the BOD equation were calculated by using the non-linear least square method for the BOD equation, giving joint confidence regions for the calculated parameters. It was concluded that ozone is most effective for the removal of color and the increase of BOD in secondary effluent. 相似文献
The experiments were conducted both on a synthetic water, with or without addition of humic substances, and on raw water from the Moulin-Papon dam. While iron was easily removed by simply increasing the pH measurement from 8.2 to 8.5 without intermediate oxidation, ozonation applied to water with a pH of nearly 8.4 did not enable the manganese to be removed with a low ozone dose (about 1 mg/L) unless a significant amount of bicarbonates (120 to 130 mg/L as CaCO3) were injected prior to the ozonation-filtration stage.
As it removes the manganese from the water, intermediate ozonation also removes the abatement of organics on the filters, and lowers the THM buildup potential. 相似文献
The aim of this paper is to present the data obtained and to try to model for some waterworks the bromate formation by means of some important parameters (Br, O3/DOC, T° and pH) of water to ozonate.
The main conclusion is that the bromate presence in distributed drinking waters is a reality for waterworks using ozonation steps, especially in warm period of the year. In the case of some waterworks, disinfection by sodium hypochlorite increased bromate levels in distributed water.
As shown by others on a laboratory-scale level, a multi-linear regression allows us the prediction of the bromate formation from some determining parameters, for some waterworks. However, the poor values of the linear regression lead us to have some doubts about its universal application in the real situation of an operating waterworks. A better evaluation of “C.t” will be required in the future in order to get a better prediction by the use of multi linear regression. 相似文献
First of all, an obvious fact must be remembered. Each installation is a special case. It is therefore out of the question to present general results with direct across-the-board applications. On the other hand, it is possible to engineer a general methodology for price calculation and apply it to a few specific examples. As operator of a large number of these facilities, Compagnie Générale des Eaux can present economic results in many, widely different technological economic conditions.
Generally speaking, it can be said that the cost of ozonation is increasingly optimized. This technique, considered a few years ago as a luxury, is now technically and economically ready for incorporation on an equal footing in most treatment trains. 相似文献
Further developments are expected in the field of lamp construction and also improvement of reactor geometry. A better knowledge of the aging of the lamps is required, as well as of the photochemical reactions of oxygen in the technologies applied.
Systems presently available are most promising for application on small scale or in areas of public water distribution which have no developed structure.
Ozonation was found able to oxidize some organic nitrogen into ammonia, and nitrite ion into nitrate ion. It was also found out, with interest, that the O3-BAC process can carry the nitrification process to the end under sufficient DO content, as well as more hydrocarbon substrates through ozonation that are more easily assimilated by some strains of nitrobacter that can multiply heterotrophically in its carbon beds. In the BAC process, both the DO and easily assimilated substrate contents were too low in its carbon beds due to no ozonation to sustain nitrobacter growth; but the nitrite conversion bacteria, like nitrosornas, can survive under such conditions. As a result, nitrite or nitrate ion content increased multiply in the effluents from BAC or O3-BAC processes over their influents. respectively.
The removal mechanisms of various processes for the three forms of nitrogen were studied and discussed, and the optimum design parameters were determined as well. 相似文献
The operation of these water treatment systems has shown that safe and high quality pool water is obtained reliably and economically. One pool (Main Pool) is of Olympic size, the other (Learner pool) is designed especially for use by children. Both pools utilize a full corona discharge ozone water treatment system. They were the first ozone systems in the U.S. to be built for public pools using the process of ozonation, flocculation, filtration, ozone removal and residual chlorination.
An extensive testing program was initiated in cooperation with the Wisconsin Department of Health. The bacteriological water quality from these swimming pools was in compliance with Wisconsin State Health Regulations and the German DIN Standard 19,643.
The first year of operation of the Peck Aquatic Center has shown that the corona discharge ozone pool water treatment process can:
1) Operate reliably in a public swimming pool environment without the need for highly or special operator qualifications.
2) Produce continuously bacteria- and virus-free pool water without the harmful and unpleasant effects of chlorine.
3) Creates a user constituency group praising and promoting the use of “minimal chlorine swimming” in the community. 相似文献
It was shown that the efficiency of biosorption process after preliminary ozonation was 2–3 times lower than without preliminary treatment that correlated with changes of the free energy of adsorption. 相似文献
A specific conductimetric method with anion suppression which enhances analyte detection by lowering the eluent conductivity is described in this paper for low bromate level analysis. Three eluents have been tested in order to have the best signal to noise ratio. Some other parameters likely to interfere in bromate ion detection (nitrate and sulfate in particular) are also investigated. Taking into account the results of three interlaboratory trials between six European laboratories, a 2 μg/L detection level for bromate can be established. 相似文献
Oxidation experiments have also been extended to pyrazine, and its sensitivity to only radical ozonation is shown. 相似文献
All the methods studied were able to degrade a part of the organic compounds and convert them into a more biodegradable form. Also the BOD/COD -ratio increased significantly. The removal of organic compounds by ozonation was 30 - 50 %. Hydrogen peroxide addition did not improve the degradation. The combination of pre-ozonation and biological post-treatment gave a total TOC removal between 50 - 95 %. 相似文献
This comparison was undertaken on three models of natural organic compounds : an aquatic fulvic acid, a protein and a disaccharide. The first results showed the following order of relative efficiency: O3/TiO2 > O3/H2O2 > O3 as far as Total Organic Carbon (TOC) removal was concerned. 相似文献
In optimum Ou/UV system application conditions, the abatement of COD in water from the Seine river is never above 30%. On the other hand, TOC removal is increased in weakly carbonated pond water loaded with humic matter. The O3/UV system also ensures oxidation of saturated volatile organic halogens, with the exception of carbon tetrachloride. 相似文献