首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
The importance of the intake positioning height above the floor level on the performance of “ductless” personalized ventilation (“ductless” PV) in conjunction with displacement ventilation (DV) was examined with regard to the quality of inhaled air and of the thermal comfort provided. A typical office room with two workstations positioned one behind the other was arranged in a full-scale room. Each workstation consisted of a table with an installed “ductless” PV system, PC, desk lamp and seated breathing thermal manikin. The “ductless” PV system sucked the clean and cool displacement air supplied over the floor at four different heights, i.e. 2, 5, 10 and 20 cm and transported it direct to the breathing level. Moreover, two displacement airflow rates were used with a supply temperature adjusted in order to maintain an exhaust air temperature of 26 °C. Two pollution sources, namely air exhaled by one of the manikins and passive pollution on the table in front of the same manikin were simulated by constant dosing of tracer gases. The results show that the positioning of a “ductless” PV intake height up to 0.2 m above the floor will not significantly influence the quality of inhaled air and thermal comfort.  相似文献   

2.
X. Li  J. Niu  N. Gao 《Indoor air》2013,23(2):162-171
Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of PV systems with upward supplied fresh air, namely a chair‐based PV and one kind of desk‐mounted PV systems, when combined with mixing ventilation (MV) and displacement ventilation (DV) systems, are investigated using simulation method with regard to their impacts on co‐occupant's exposure to the exhaled droplet nuclei generated by the infected PV user. Simulation results of tracer gas and particles with aerodynamic diameter of 1, 5, and 10 μm from exhaled air show that, when only the infected person uses a PV, the different PV air supplying directions present very different impacts on the co‐occupant's intake under DV, while no apparent differences can be observed under MV. The findings demonstrate that better inhaled air quality can always be achieved under DV when the adopted PV system can deliver conditioned fresh air in the same direction with the mainly upward airflow patterns of DV.  相似文献   

3.
This study investigates the performance of two systems: personalized ventilation (PV) and ductless personalized ventilation (DPV). Even though the literature indicates a compelling performance of PV, it is not often used in practice due to its impracticality. Therefore, the present study assesses the possibility of replacing the inflexible PV with DPV in office rooms equipped with displacement ventilation (DV) in the summer season. Numerical simulations were utilized to evaluate the inhaled concentration of pollutants when PV and DPV are used. The systems were compared in a simulated office with two occupants: a susceptible occupant and a source occupant. Three types of pollution were simulated: exhaled infectious air, dermally emitted contamination, and room contamination from a passive source. Results indicated that PV improved the inhaled air quality regardless of the location of the pollution source; a higher PV supply flow rate positively impacted the inhaled air quality. Contrarily, the performance of DPV was highly sensitive to the source location and the personalized flow rate. A higher DPV flow rate tends to decrease the inhaled air quality due to increased mixing of pollutants in the room. Moreover, both systems achieved better results when the personalized system of the source occupant was switched off.  相似文献   

4.
This paper investigated the transmission of respiratory droplets between two seated occupants equipped with one type of personalized ventilation (PV) device using round movable panel (RMP) in an office room. The office was ventilated by three different total volume (TV) ventilation strategies, i.e. mixing ventilation (MV), displacement ventilation (DV), and under-floor air distribution (UFAD) system respectively as background ventilation methods. Concentrations of particles with aerodynamic diameters of 0.8 μm, 5 μm, and 16 μm as well as tracer gas were numerically studied in the Eulerian frame. Two indexes, i.e. intake fraction (IF) and concentration uniformity index RC were introduced to evaluate the performance of ventilation systems. It was found that without PV, DV performed best concern protecting the exposed manikin from the pollutants exhaled by the polluting manikin. In MV when the exposed manikin opened RMP the inhaled air quality could always be improved. In DV and UFAD application of RMP might sometimes, depending on the personalized airflow rate, increase the exposure of the others to the exhaled droplets of tracer gas, 0.8 μm particles, and 5 μm particles from the infected occupants. Application of PV could reduce RC for all the three TV systems of 0.8 μm and 5 μm particles. PV enhanced mixing degree of particles under DV and UFAD based conditions much stronger than under MV based ones. PV could increase the average concentration in the occupied zone of the exposed manikin as well as provide clean personalized airflow. Whether inhaled air quality could be improved depended on the balance of pros and cons of PV.  相似文献   

5.
Y. Cheng  Z. Lin 《Indoor air》2015,25(6):662-671
The motivation of this study is stimulated by a lack of knowledge about the difference of airflow characteristics between a novel air distribution method [i.e., stratum ventilation (SV)] and conventional air distribution methods [i.e., mixing ventilation (MV) and displacement ventilation (DV)]. Detailed air velocity and temperature measurements were conducted in the occupied zone of a classroom with dimensions of 8.8 m (L) × 6.1 m (W) × 2.4 m (H). Turbulence intensity and power spectrum of velocity fluctuation were calculated using the measured data. Thermal comfort and cooling efficiency were also compared. The results show that in the occupied zone, the airflow characteristics among MV, DV, and SV are different. The turbulent airflow fluctuation is enhanced in this classroom with multiple thermal manikins due to thermal buoyancy and airflow mixing effect. Thermal comfort evaluations indicate that in comparison with MV and DV, a higher supply air temperature should be adopted for SV to achieve general thermal comfort with low draft risk. Comparison of the mean air temperatures in the occupied zone reveals that SV is of highest cooling efficiency, followed by DV and then MV.  相似文献   

6.
Personalized ventilation (PV) is an individually controlled air distribution system aimed at improving the quality of inhaled air and the thermal comfort of each occupant. Numerous studies have shown that PV in comparison with traditional mechanical ventilation systems may improve occupants’ health, inhaled air quality, thermal comfort, and self-estimated productivity. Little is known about its energy performance.In this study, the energy consumption of a personalized ventilation system introduced in an office building located in a hot and humid climate (Singapore) has been investigated by means of simulations with the empirically tested IDA-ICE software. The results reveal that the use of PV may reduce the energy consumption substantially (up to 51%) compared to mixing ventilation when the following control strategies are applied: (a) reducing the airflow rate due to the higher ventilation effectiveness of PV; (b) increasing the maximum allowed room air temperature due to PV capacity to control the microclimate; (c) supplying the outdoor air only when the occupant is at the desk. The strategy to control the supply air temperature does not affect the energy consumption in a hot and humid climate.  相似文献   

7.
The main objective of this study was to examine the performance of protected zone ventilation (PZV) and hybrid protected zone ventilation (HPZV) to reduce the direct exposure to exhaled air from others' breathing. Experimental measurements are carried out to test the performance of PZV in a full‐scale office room with two breathing thermal manikins. The measurements were performed under three configurations, including two standing manikins at different distances: 0.35, 0.5, and 1.1 m. When the supply air velocity is increased to 4 m/s in the downward plane jet, the dimensionless concentration is 40% lower than for fully mixed ventilation, which can be considered as a measure of protection from the zoning condition. The measurement results showed that in both the PZV and the HPZV system it is possible to decrease the transmission of tracer gas from one manikin to the opposite manikin; therefore, it probably would reduce the risk of air borne cross‐infection between two people at the same relative positions. The results suggest that PZV and HPZV may be used to reduce the exposure of people in a protected zone from indoor pollutants emitted in a source zone.  相似文献   

8.
In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)–personalized exhaust (PE) system has been developed, which aims to exhaust the exhaled air as much as possible from around the infected person (IP). The PV–PE system was studied experimentally for a particular healthcare setting based on a typical consultation room geometry and four different medical consultation positions of an IP and a healthy person (HP). Experiments using two types of tracer gases were conducted to evaluate two types of PE: Top‐PE and Shoulder‐PE under two different background ventilation systems: Mixing Ventilation and Displacement Ventilation. Personalized exposure effectiveness, intake fraction (iF) and exposure reduction (ε) were used as indices to evaluate the PV–PE system. The results show that the combined PV‐PE system for the HP achieves the lowest intake fraction; and the use of PE system for the IP alone shows much better performance than using PV system for the HP alone.  相似文献   

9.
Personalized ventilation is expected to improve the quality of inhaled air and accommodate individual thermal preferences. In this paper, a chair-based personalized ventilation system is proposed that can potentially be applied in theatres, cinemas, lecture halls, aircrafts, and even offices. Air quality, thermal comfort, and the human response to this ventilation method were investigated by experiments. By comparing eight different air terminal devices (ATDs) it was found that up to 80% of the inhaled air could be composed of fresh personalized air with a supply flow rate of less than 3.0 l/s. Perceived air quality improved greatly by serving cool air directly to the breathing zone. Feelings of irritation and local drafts could be eliminated by proper designs. Personalized air with a temperature below that of room air was able to bring “a cool head” and increased thermal comfort in comparison with mixing ventilation. Massive applications of this chair-based personalized ventilation system can be envisaged in the future.  相似文献   

10.
The level of exposure to human exhaled contaminants in a room depends not only on the air distribution system but also on people's different positions, the distance between them, people's activity level and height, direction of exhalation, and the surrounding temperature and temperature gradient. Human exhalation is studied in detail for different distribution systems: displacement and mixing ventilation as well as a system without mechanical ventilation. Two thermal manikins breathing through the mouth are used to simulate the exposure to human exhaled contaminants. The position and distance between the manikins are changed to study the influence on the level of exposure. The results show that the air exhaled by a manikin flows a longer distance with a higher concentration in case of displacement ventilation than in the other two cases, indicating a significant exposure to the contaminants for one person positioned in front of another. However, in all three cases, the exhalation flow of the source penetrates the thermal plume, causing an increase in the concentration of contaminants in front of the target person. The results are significantly dependent on the distance and position between the two manikins in all three cases. PRACTICAL IMPLICATIONS: Indoor environments are susceptible to contaminant exposure, as contaminants can easily spread in the air. Human breathing is one of the most important biological contaminant sources, as the exhaled air can contain different pathogens such as viruses and bacteria. This paper addresses the human exhalation flow and its behavior in connection with different ventilation strategies, as well as the interaction between two people in a room. This is a key factor for studying the airborne infection risk when the room is occupied by several persons. The paper only takes into account the airborne part of the infection risk.  相似文献   

11.
Solar air-conditioning can have higher application potential for buildings through the strategy of high temperature cooling. In recent years, displacement ventilation (DV), which makes use of the indoor rising plumes from the internal heat gains, provides a more effective supply air option than the traditional mixing ventilation (MV) in terms of both thermal comfort and indoor air quality. As it is possible to raise the supply air temperature to 19 °C for DV, it would enhance the competitive edge of the solar air-conditioning against the conventional vapour compression refrigeration. Through dynamic simulation, a solar-desiccant-cooling displacement ventilation system (SDC_DV) was developed for full-fresh-air provision, while a solar-hybrid-desiccant-cooling displacement ventilation system (SHDC_DV) for return air arrangement. The latter was further hybridized with absorption chiller (AB) to become SHDCAB_DV, or adsorption chiller (AD) to be SHDCAD_DV, in order to be wholly energized by the solar thermal gain. Benchmarked with the conventional system using MV, the SDC_DV had 43.3% saving in year-round primary energy consumption for a typical office in the subtropical climate; the SHDCAB_DV had 49.5% saving, and the SHDCAD_DV had 18.3% saving. Compared with their MV counterparts, the SDC_DV, the SHDCAB_DV and the SHDCAD_DV could have 42.4%, 21.9% and 30.3% saving respectively.  相似文献   

12.
Design guidelines envisage that floor heating can be used together with displacement ventilation (DV), provided that the supply air is not overly heated before it can reach heat and contaminant sources. If this is not controlled a mixing flow pattern could occur in the room. The use of floor cooling with DV is also considered possible, although draught risk at ankle level and vertical air temperature differences must be controlled carefully, because they could increase.Few studies on these topics were found in the literature.An indoor environmental chamber was set up to obtain measurements aimed at analysing the possibilities and limitations of combining floor heating/cooling with DV. Air temperature profiles, air velocity profiles, surface temperatures and ventilation effectiveness were measured under different environmental conditions that may occur in practice. These values were compared to equivalent temperature measurements obtained using a thermal manikin.The measurements show that floor heating can be used with DV, obtaining high ventilation effectiveness values. A correlation between the floor heating capacity and the air temperature profile in the room was found. Measurements showed that floor cooling does not increase draught risk at ankle level, although it does increase vertical air temperature differences.  相似文献   

13.
Auxiliary ventilation is performed by carrying intake or return air in ducts. The complete elimination of air leakage from or into the ducting system is impossible due to duct quality and numerous joints in ducting system. The auxiliary ventilation systems for long drivages often require the use of multiple fans. Fans are installed in series and separated from each other in fixed or variable lengths. There are many methods proposed for the analysis air flow problems in leaky ducts. Due to the lengthy calculations, computers are often needed to conduct the analyses. In this study, a method known as “series–parallel combination of the duct and leakage path” has been introduced and a computer program has been developed based on this method.In order to design the conditions of an auxiliary ventilated drivage, in situ measurement have been made in Western Lignite Enterprises (GLI) OMERLER underground coal mine (Turkey) and the related data necessary for this study was collected. The presently developed program was tested using these data, and it was found that the measured and calculated values are quite close.The effective operational parameters governing auxiliary ventilation have been investigated and the effects of these variables on the volume rate of air flow reaching long drivage face have been examined by using linear regression analysis. Finally, it was concluded that the increase of duct diameter has prime importance in achieving the adequate air flow to the face and that for the auxiliary fans considered in this study the selection of fan does not greatly affect the volume rate reaching the face in a long duct line.  相似文献   

14.
《Energy and Buildings》2002,34(8):829-836
Personalized ventilation (PV) aims to provide clean air to the breathing zone of occupants. Its performance depends to a large extent on the supply air terminal device (ATD). Five different ATDs were developed, tested and compared. A typical office workplace consisting of a desk with mounted ATDs was simulated in a climate chamber. A breathing thermal manikin was used to simulate a human being. Experiments at room air temperatures of 26 and 20 °C and personalized air temperatures of 20 °C supplied from the ATDs were performed. The flow rate of personalized air was changed from less than 5 up to 23 l/s. Tracer gas was used to identify the amount of personalized air inhaled by the manikin as well as the amount of exhaled air re-inhaled. The heat loss from the body segments of the thermal manikin was measured and used to calculate the equivalent temperature for the whole body as well as segments of the body. An index, personal exposure effectiveness, was used to assess the performance of ATDs in regard to quality of the air inhaled by the manikin. The personal exposure effectiveness increased with the increase of the airflow rate from the ATD to a constant maximum value. A further increase of the airflow rate had no impact on the personal exposure effectiveness. Under both isothermal and non-isothermal conditions the highest personal exposure effectiveness of 0.6 was achieved by a vertical desk grill followed by an ATD designed as a movable panel. The ATDs tested performed differently in regard to the inhaled air temperature used as another air quality indicator, as well as in regard to the equivalent temperature. The results suggest that PV may decrease significantly the number of occupants dissatisfied with the air quality. However, an ATD that will ensure more efficient distribution and less mixing of the personalized air with the polluted room air needs to be developed.  相似文献   

15.
Experimental investigation of heat transfer during night-time ventilation   总被引:2,自引:0,他引:2  
Night-time ventilation is seen as a promising approach for energy efficient cooling of buildings. However, uncertainties in the prediction of thermal comfort restrain architects and engineers from applying this technique. One parameter essentially affecting the performance of night-time ventilation is the heat transfer at the internal room surfaces. Increased convection is expected due to high air flow rates and the possibility of a cold air jet flowing along the ceiling, but the magnitude of these effects is hard to predict. In order to improve the predictability, heat transfer during night-time ventilation in case of mixing and displacement ventilation has been investigated in a full scale test room. The results show that for low air flow rates displacement ventilation is more efficient than mixing ventilation. For higher air flow rates the air jet flowing along the ceiling has a significant effect, and mixing ventilation becomes more efficient. A design chart to estimate the performance of night-time cooling during an early stage of building design is proposed.  相似文献   

16.
The gaseous contaminant diffusion under stratum ventilation is investigated by numerical method which is validated by experiments carried out. The concentration of gaseous contaminants along the supply air jet is found to be lower than the other parts of the room. Compared with displacement ventilation, the formaldehyde concentration in breathing zone is lower when a contaminant source locates close to the occupant. The concentration is at the same level when the contaminant source locates up-steam to the occupant. The concentration in the occupied zone (<1.9 m from the floor) is also lower when the contaminant source locates on the floor. At supply air temperature optimized for displacement ventilation, the toluene concentration in breathing zone for stratum ventilation is higher than that for displacement ventilation when the area source locates on the four surrounding walls of the room.  相似文献   

17.
The aim of this paper is to develop an optimized online supervisory control predictive tool for the chilled ceiling displacement ventilation (CC/DV) system to minimize energy consumption while creating the best indoor air quality (IAQ) and thermal comfort. The online controller is designed to operate under an optimized control strategy with five control set points. A dynamic multi-variable objective cost function is formulated for the supervisory control of the CC/DV system performance indices and constraints, and is solved using genetic algorithm. The design of the optimized controller takes into consideration the response time of three-way valves, reheat, and supply fan to employ signaled changes in set points.The developed online controller response to load changes and its ability to change system set points to optimally meet unknown load and constrains are tested and evaluated under the simulated ‘real life’ environment for a case study. It is shown that the implemented online optimized controller is robust, and its development contributes to improved CC/DV system energy efficiency.  相似文献   

18.
A model for displacement ventilation system based on plume rise of single point heat source was developed. The errors for temperature gradient ratio were less than 6% in most cases. Errors for temperature gradient and displacement zone height were relatively higher (up to 28.1%) which might be due to the derivation of the parameters from experimental data. Still, the errors were lower than those from design model/method of some other workers (68.5% for the temperature gradient ratio and 15.7% for the temperature difference between the supply air and at 0.1 m above floor level). With a room height of 2.4 m (common for office in Hong Kong) and design room temperature 25.5 °C defined at 1.1 m above floor level under the normal load to air flow ratio of 12,000 W/m3/s (typical values for sub-tropical region) and minimum supply temperature of 18 °C, there existed a zone capacity range from 1000 to 5000 W that stand alone operation displacement ventilation system was feasible and that the displacement zone height (minimum 2.2 m) was above normal breathing level. The feasible zone capacity range diminished with decrease in design room temperature and/or room height. In this case, the load to air flow ratio had to be reduced, resulting in a higher flow rate when compared to a mixing ventilation system, or an auxiliary cooling facility such as a chilled ceiling had to be used.  相似文献   

19.
A field survey of occupants' response to the indoor environment in 10 office buildings with displacement ventilation was performed. The response of 227 occupants was analyzed. About 24% of the occupants in the survey complained that they were daily bothered by draught, mainly at the lower leg. Vertical air temperature difference measured between head and feet levels was less than 3 degrees C at all workplaces visited. Combined local discomfort because of draught and vertical temperature difference does not seem to be a serious problem in rooms with displacement ventilation. Almost one half (49%) of the occupants reported that they were daily bothered by an uncomfortable room temperature. Forty-eight per cent of the occupants were not satisfied with the air quality. PRACTICAL IMPLICATIONS: The PMV and the Draught Rating indices as well as the specifications for local discomfort because of the separate impact of draught and vertical temperature difference, as defined in the present standards, are relevant for the design of a thermal environment in rooms with displacement ventilation and for its assessment in practice. Increasing the supply air temperature in order to counteract draught discomfort is a measure that should be considered carefully; even if the desired stratification of pollution in the occupied zone is preserved, an increase of the inhaled air temperature may have a negative effect on perceived air quality.  相似文献   

20.
《Building and Environment》2005,40(8):1051-1067
The purpose of this paper is to investigate using a numerical simulation (computational fluid dynamics or CFD) the effect of the air supply location on the design and performance of the displacement ventilation (DV) system. The results are reported in terms of thermal comfort and indoor air quality. The study focuses on the typical Hong Kong office under local thermal and boundary conditions. This includes the high cooling load used in Hong Kong. Several pollutants typically found in the office such as carbon dioxide and volatile organic compounds (VOCs) were investigated. The results indicate that the supply should be located near the center of the room rather than to one side of the room. This will provide a more uniform thermal condition in the office. The DV system was found to be effective in dispersing VOCs within an office environment for all cases studied. The exhaust was found to have minimal effect on the thermal comfort. For a DV system in Hong Kong, it is possible to use 100% fresh air without extra energy consumption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号